Dimensions (unit: mm) Timing Diagram Operation Mounting and Adjustment


●Reflector(MS-2) Stable Received When using photoelectric sensors closely over two units, it may result in malfunction due to mutual
Photoelectric Sensor
58
40.6 8.5 light area interference.
21 18 7
34
When installing the product, tighten the screw with a tightening torque of 1.2N.m.

5.6
BEN SERIES ø6

Light receiving
6.4

22
Unstable operating ◎Through-beam type

60.4
INSTRUCTION MANUAL

52

40

21
area 1. Supply the power to the photoelectric sensor, after setting the
BEN300-DFR
Operating Adjust Receiver

STAB.
emitter and the receiver in face to face.
AC24-240V
BN DC24-240V
BU OV
BK N.O

level Right/Left
MIN MAX L.ON D.ON WH COM

OUT
2. Set the receiver in center of position where indicator turns on,
SENS. MODE GY N.C

PHOTOELECTRIC SENSOR KOREA 3B111B

Stable Interrupted as adjusting the receiver and the emitter right and left. Emitter cal
2-ø3.8 50 Opti
light area 3. Adjust up and down direction as the same. axis
●Through-beam type ●Retroreflective/Diffuse reflective 4. After adjustment, check the stability of operation putting the
Power indicator(Red) Stable indicator(Green) Operation indicator(Red) object at the optical axis.
18
Optical axis ON
5 Stability indicator
Receiver Able to install Adjust Up/Down
(Green LED) ※If the sensing target is translucent body or smaller than ø16mm,

5
bracket in this part OFF
it might not detect the target cause light passed.
Optical axis
Operation indicator ON
Emitter
(Red LED) OFF

Note1 Note2
Light ON

50
operation

60

60
Thank you for choosing our Autonics product. Transistor output ON ◎Retroreflective type

25
25
Please read the following safety considerations before use. (Relay contact) OFF 1. Supply the power to the photoelectric sensor, after setting the
Adjust
(Control output according to amount of receiving light) photoelectric sensor and the reflector(MS-2) in face to face.
Right/Left Reflector
Safety Considerations 2. Set the photoelectric sensor in the position which indicator turns on,

2
(MS-2)
Cable: as adjusting the mirror or the sensor right and left.
※Please observe all safety considerations for safe and proper product operation to avoid hazards. Emitter Receiver
M4 Bolt ø5, 2m 3. Adjust up and down direction as the same. cal
The waveform of Transistor output and operation indicator are the state of operation for Light ON, Opti
※ symbol represents caution due to special circumstances in which hazards may occur. ※Note1)Retroreflective: 21.25mm, Diffuse reflective: 20.25mm 4. After adjustment, check the stability of operation putting the object axis
※Note2)Retroreflective: 7.5mm, Diffuse reflective: 9.5mm but in case of Dark ON, it is opposite operation against Light ON. at the optical axis. Adjust Up/Down
Warning Failure to follow these instructions may result in serious injury or death.
Caution Failure to follow these instructions may result in personal injury or product damage. Specifications ※If use more than 2 photoelectric sensors in parallel, the space
between them should be more than 30cm.
Free power, Relay contact output DC power, Solid state output ※If reflectance of target is higher than non-glossy white paper, it 30° to 45°
Warning Type
Through-beam Retroreflective※1 Retroreflective※1
Diffuse reflective Through-beam Retroreflective※1 Retroreflective※1
Diffuse reflective might cause malfunction by reflection from the target when the
(with polarizing filter) (with polarizing filter)
1. Fail-safe device must be installed when using the unit with machinery that may cause target is near to photoelectric sensor. Therefore put enough space
serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, Model BEN10M-TFR BEN5M-MFR BEN3M-PFR BEN300-DFR BEN10M-TDT BEN5M-MDT BEN3M-PDT BEN300-DDT
between the target and photoelectric sensor or the surface of target L
ships, vehicles, railways, aircraft, combustion apparatus, safety 300mm(100 x 100mm 300mm(100 x 100mm Reflector
Sensing distance 10m 0.1 to 5m 0.1 to 3m 10m 0.1 to 5m 0.1 to 3m should be installed at an angle of 30 to 45° against optical axis.
equipment, crime/disaster prevention devices, etc.) non-glossy white paper) non-glossy white paper)
Sensing (MS-2)
Failure to follow this instruction may result in fire, personal injury, or economic loss. Sensing target Opaque materials of min. ø16mm Opaque materials of min. ø60mm Translucent, opaque materials Opaque materials of min. ø16mm Opaque materials of min. ø60mm Translucent, Opaque materials (When sensing target with high reflectance near by, photoelectric target
2. Do not disassemble or modify the unit. Hysteresis - Max. 20% at sensing distance - Max. 20% at sensing distance sensing with the polarizing filter should be used.)
Failure to follow this instruction may result in electric shock or fire. Response time Max. 20ms Max. 1ms ※Sensitivity adjustment: Please see the diffuse reflective type.
3. Do not connect, repair, or inspect the unit while connected to a power source. Power supply 24-240VACᜠ ±10% 50/60Hz, 24-240VDCᜡ ±10% (ripple P-P: max. 10%) 12-24VDCᜡ ±10% (ripple P-P: max. 10%)
Failure to follow this instruction may result in electric shock or fire. Power consumption Max. 4VA -
4. Check ‘Connections’ before wiring.
Current consumption - Max. 50mA
Failure to follow this instruction may result in fire. ◎Diffuse reflective type
Light source Infrared LED (850nm) Red LED (660nm) Infrared LED (940nm) Infrared LED (850nm) Red LED (660nm) Infrared LED (940nm)
Caution 1. Even though the diffuse reflective type is set at max. sensitive
Photoelectric
1. Use the unit within the rated specifications. Sensitivity adjustment - Sensitivity adjuster - Sensitivity adjuster position, sensitivity of the sensor must be adjusted the according sensor
Failure to follow this instruction may result in fire or product damage. Operation mode Selectable Light ON or Dark ON by switch to the existence of the reflective material in background.
2. Use dry cloth to clean the unit, and do not use water or organic solvent. Relay contact output NPN open collector/PNP open collector simultaneous output 2. Set the target at a position to be detected by the beam, then
Failure to follow this instruction may result in electric shock or fire. Control output ●Relay contact capacity: 30VDCᜡ 3A of resistive load, 250VACᜠ 3A of resistive load ●Load voltage: max. 30VDCᜡ ●Load current: max. 200mA turn the adjuster until point ⓐ where the indicator turn on from Sensing
3. Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct ●Relay contact composition: 1c ●Residual voltage - NPN: max. 1VDCᜡ, PNP: max. 2.5VDC target
min. position of the adjuster.
sunlight, radiant heat, vibration, impact, or salinity may be present. Relay lifetime Mechanically: Min. 50,000,000 operation, Electrically: Min. 100,000 operation - 3. Take the target out of the photoelectric sensor, then turn the
Failure to follow this instruction may result in fire or explosion. Protection circuit - Reverse polarity protection circuit, output short overcurrent protection circuit adjuster until point ⓑ which the indicator turns on, if the indicator
4. Do not use a load over the range of rated relay specification. Light receiving element Photo IC Optimal
Failure to follow this instruction may result in insulation failure, contact melt, contact failure, relay broken, does not turn on, max. sensitive position will be point ⓑ. ⓐ
Indication Operation indicator: red, stable indicator: green (the red lamp on Emitter of through-beam type is for power indication) position
or fire. 4. Set the adjuster at the middle of two switching point ⓐ, ⓑ.
Insulation resistance Over 20MΩ (at 500VDC megger) ⓑ
Ordering Information Insulation type Double or strong insulation (mark: , Dielectric voltage between the measured input and the power: 1kV) - ※The sensing distance indicated on specification chart is against
Min Max
Noise immunity ±1000V the square wave noise (pulse width: 1㎲) by the noise simulator ±240V the square wave noise (pulse width: 1㎲) by the noise simulator 100 x100mm of non-glossy white paper. Be sure that it can be
BEN 10M T D T Dielectric strength 1000VAC 50/60Hz for 1minute different by size, surface and gloss of target.
SENS.
Mechanical 1.5mm amplitude at frequency of 10 to 55Hz in each of X, Y, Z directions for 2 hours
Output R Contact output (Relay) Vibration
Malfunction 1.5mm amplitude at frequency of 10 to 55Hz in each of X, Y, Z directions for 10 minutes -
T Solid-state outputt (Transistor) 500m/s2(50G) in X, Y, Z directions for 3 times
Power supply
Shock
Mechanical
Malfunction 100m/s2(10G) in X, Y, Z directions for 3 times - Cautions during Use
D DC power
Ambient illumination Sunlight: max. 11,000㏓, incandescent lamp: max. 3,000㏓ (receiver illumination) 1. F ollow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
F Free power Environ
Ambient temperature -20 to 65℃, storage : -25 to 70℃ 2. W hen connecting a DC relay or other inductive load to the output, remove surge by using diodes or
ment
Ambient humidity 35 to 85%RH, storage: 35 to 85%RH varistors.
T Through-beam
Protection structure IP50 (IEC standard) 3. U se the product, 0.5 sec after supplying power.
Sensing type M Retroreflective
Material ●Case, case cover: heat resistant ABS ●Sensing part: PC (with polarizing filter: PMMA) When using separate power supply for the sensor and load, supply power to sensor first.
P Retroreflective with polarizing filter ø5.0mm, 5-wire, length: 2m (emitter of through-beam type: ø5.0mm, 2-wire, length: 2m) ø5.0mm, 4-wire, length: 2m (emitter of through-beam type: ø5.0mm, 2-wire, length: 2m) 4. 1 2-24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power
Cable supply device.
D Diffuse reflective (AWG22, core diameter: 0.08mm, number of cores: 60, insulator diameter: ø1.25mm) (AWG22, core diameter: 0.08mm, number of cores: 60, insulator diameter: ø1.25mm)
Individual - Reflector (MS-2) - - Reflector (MS-2) - 5. W ire as short as possible and keep away from high voltage lines or power lines, to prevent inductive
Sensing distance M Unit: m Acces noise.
Adjustment screwdriver, Adjustment screwdriver,
Unit: mm sory Common mounting bracket, Adjustment screwdriver, mounting bracket, M4 bolt: 2, M4 nut: 2 mounting bracket, Adjustment screwdriver, mounting bracket, M4 bolt: 2, M4 nut: 2 6. W hen using switching mode power supply to supply the power, ground F.G. terminal and connect a
M4 bolt: 4, M4 nut: 4 M4 bolt: 4, M4 nut: 4 condenser between 0V and F.G. terminal to remove noise.
Item
BEN Photoelectric sensor series Approval - 7. W hen using sensor with the equipment which generates noise (switching regulator, inverter, servo
Unit weight Approx. 354g Approx. 208g Approx. 195g Approx. 342g Approx. 200g Approx. 187g motor, etc.), ground F.G. terminal of the equipment.
Control Output Circuit Diagram ※1: The sensing range and the sensing object of the retroreflective sensor are specified with using the MS-2 reflector. The sensing ranges of the retroreflective sensor in the above table are indentified as the possible 8. This unit may be used in the following environments.
setting ranges of the MS-2 reflector. The sensor can detect on object under 0.1m apart. ①Indoors (in the environment condition rated in 'Specifications')
Item Photoelectric sensor circuit Connection
※The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment. ②Altitude max. 2,000m
(brown)+V ③Pollution degree 2
Output short
overcurrent
Max. 200mA Connection ④Installation category II

protection circuit Load Through-beam Retroreflective Diffuse reflective


Main circuit

(white)PNP output
NPN/PNP
●BEN10M-TFR1 ●BEN10M-TFR2 ●BEN5M-MFR/BEN3M-PFR(with polarizing filter) ●BEN300-DFR
Major Products
2 output (black)NPN output + Photoelectric Sensors Temperature Controllers
(DC power) 12-24VDC 24-240VAC
- Emitter Receiver 24-240VDC 24-240VAC MS-2 24-240VAC Fiber Optic Sensors Temperature/Humidity Transducers
Output short
overcurrent Load Max. 200mA (brown)(blue) 24-240VDC (reflector) 24-240VDC Door Sensors SSRs/Power Controllers
protection circuit + - (brown)(blue) (brown)(blue)
(blue)0V Door Side Sensors Counters
Sensing + - + - Sensing
target target Area Sensors Timers
※If short-circuit the control output terminal or supply current over the rated specification,
+ - Sensing Proximity Sensors Panel Meters
normal control signal is not output due to the output short over current protection circuit.
(brown)(blue) target Pressure Sensors Tachometers/Pulse (Rate) Meters
Item Photoelectric sensor circuit Connection 24-240VAC (white) (black) (gray) (white) (black) (gray) (white) (black) (gray)
24-240VDC Tc Ta Tb Tc Ta Tb Tc Ta Tb Rotary Encoders Display Units
(gray)Tb
Relay (black)Ta
}
Contact output(1c) ●BEN10M-TDT1 ●BEN10M-TDT2 ●BEN5M-MDT/BEN3M-PDT(with polarizing filter) ●BEN300-DDT Connector/Sockets Sensor Controllers
Main circuit

Relay (white)Tc Switching Mode Power Supplies


contact 12-24VDC 12-24VDC
(brown) + Emitter Receiver 12-24VDC + - Control Switches/Lamps/Buzzers
(Free power) + - + - MS-2
Free power I/O Terminal Blocks & Cables
Power 24-240VAC (reflector)
(brown)(blue)
circuit (blue) 24-240VDC (brown)(blue) Stepper Motors/Drivers/Motion Controllers
- (brown)(blue) Sensing http://www.autonics.com
Sensing target Graphic/Logic Panels HEADQUARTERS:
※The product is not equipped with the output short over current protection circuit. If short-circuit the target
Sensing Field Network Devices 18, Bansong-ro 513beon-gil, Haeundae-gu, Busan,
control output terminal or supply current over the rated specification, it may result in product damage.
(brown)(blue) target South Korea, 48002
※The above specifications are subject to change and some models may be discontinued + - Laser Marking System (Fiber, Co₂, Nd:yag)
(white) (black) (white) (black) (white) (black) TEL: 82-51-519-3232
without notice. (PNP) (NPN) (PNP) (NPN) Laser Welding/Cutting System
12-24VDC (PNP) (NPN) E-mail: sales@autonics.com
※Be sure to follow cautions written in the instruction manual and the technical descriptions
(catalog, homepage). ※Non-using wires must be insulated. DRW171448AA

You might also like