Keypad Definitions

Error Codes Error Codes Error Codes


2
Cabinet Hardmount Washer-Extractor Display Description Cause/Correction Display Description Cause/Correction Display Description Cause/Correction
3
Pocket Programming Guide
EI01 Transmission Failure Comm. failure. Re-aim E do Door Open Error Control detects open door. Ed02 DC Bus Error DC bus is too high. Power down and
1 4 external device and retry. Power down machine and retry. (Design 2 and 3) retry.
5 EI02 Time-out Error Comm.failure. Re-aim E Ub Unbalance Error Unable to balance load. Ed03 Tachometer Error Tachometer input is damaged during
external device and retry. Redistribute load and retry. (Design 2 and 3) power up or no tachometer signal is
detected. Power down and retry.
EI03 Invalid Command Code Comm failure. Command was door Door Open Indicator Door is not closed or door
not valid or machine could not switch is damaged. Ed04 Locked Rotor Error Motor does not reach speed at startup.
perform command. (Design 2 and 3) Power down and retry.
E dr Drain Alarm Error Machine did not drain. Power
6
CHM1311R
EI04 Expecting Upload Comm. failure. Re-aim down machine. Ed05 IGBT Overcurrent Drive detects an overcurrent shunt
8 7 Request external device and retry. Error (Design 2 condition. Power down and retry.
CHM1311R E Ht Heat Alarm Error Heat alarm time is exceeded. and 3)
1 SELECT CYCLE pads EI05 Invalid/Out-of-Range Programming option values Turns off heater output for
2 Display Data are out of range. cycle. Ed06 Thermal Error Control detects a high IPM temperature.
(Design 2 and 3) Power down and retry.
3 Four 7-Segment Digits EI09 CRC-16 Error Comm. failure. Re-aim E oP Open Termperature Control senses temp. less than
4 STOP pad external device and retry. Sensor Error 0°F (-18°C). Heater and Ed07 No Setup Error Drive receives movement commands
5 START pad thermistor operations are (Design 2 and 3) without receiving a setup packet. Power
EI0A Framing Error Comm. failure. Re-aim
6 LED Light CHM1311R
CHM1311R disabled for cycle. down and retry.
external device and retry.
7 Cycle Indicator Lights E SH Shorted Temperature Control senses temp. greater Ed08 Max Over Current Drive detects motor output overcurrent
8 LED Status Lights OPL Models with an “H” in the 7th Position EI0C Time-out Exceeded Comm. failure. Re-aim Sensor Error than 220°F (104°C). Heater and Error (Design 2 condition. Power down and retry.
external device and retry. thermistor operations are and 3)
Entering the Manual Programming Mode EI0E Encryption Error Check security code and retry. disabled for cycle.
1. If the washer is in an active cycle, rapid advance through the Ed09 Current Sensor Drive detects a current sensor is not
Keypad Definitions EI0F Infra-red Disabled Comm. failure or infra-red is E db Drive Balance Switch VFD balance switch closed at Error (Design 2 operating properly. Power down and
cycle. disabled. Enable infra-red and Error start of drain step. Power down and 3) retry.
2. Open the washer’s top cover. Entering the Manual Programming Mode retry. machine.
3. While pressing and holding the #4 keypad, press the #1 Exiting the Manual Programming Mode E FL Fill Error Water level not reached. E Ld Water Leak Detection Water leak during test or cycle.
keypad. The display will show “rAPD.” Error Codes Power down machine. Error (Design 1) Error logged.
4. Press the #3 ( ) or #6 ( ) keypad until “Prog” is displayed. E SP SPI Communications Control cannot communicate E Ld Drain Valve Leak Drain valve leak during test or
>

Programmable Options
<

5. Press the START keypad. The first manual programming Error with output board. Power Detection Error cycle.
option, “dCYC,” is displayed. down machine and retry. (Design 2 and 3) Error logged
E dL Door Lock Error Door does not lock or unlock. E LF Water Leak Detection Fill valve leak during test or
Exiting the Manual Programming Mode Press any key to repeat the Error (Design 2 and 3) cycle. Error logged.
1. Press the #5 (<) keypad until the control returns to Start lock or unlock sequence. E Sd Slow Drain Error Slow drain. Error logged.
Mode.
If the door is open, verify the Ed01 SPI Communication Control cannot communicate
solenoid is not extended. Error (Design 2 and 3) with motor drive. Power down
Attempt closing the door. and retry.

If the control doesn't respond,


Part No. 8-09-151GR4 power down machine and
April 2019 retry.

© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT


Programmable Options
Option Option
Description Default Range
Number Display
1 dCYC Default Cycle 5 1-9
2 AUd Audio Signal 29* 0-31
3 Err- Errors — —
a. E FL Fill Errors on on/oFF
b. E dr Drain Errors on on/oFF
c. E Ub Unbalance Error Display on on/oFF
d. E oP Open Thermistor Error Display on on/oFF
e. E SH Shorted Thermistor Error Display on on/oFF
f. E Ht Heat Error Display (Heater only) on on/oFF
g. LEr- Water Leak Detection Error — —
1. LEr1 Water Leak Detection oFF on/oFF
During a Machine Cycle (On/Off)
2. LEr3 Number of Cycles between Leak 0* 1-127*
Detection Test
h. E Sd Slow Drain Detection oFF on/oFF
4 CyC- Cycle Programming ** —
a. AgIt Cycle Agitate — —
1. tyPE Agitate Type ** 1-2
2. ASPd Agitate Speed (VFD only) ** Lo/rEg
b. Seg- Cycle Segment Programming — —
1. SgEn Segment Enable/Disable ** on/oFF
2. FILL Fill Step — —
a. FLEn Fill Step Enable/Disable ** on/oFF
b. FLEU Fill Level ** HI/nEd/Lo
c. tEnP Fill Temperature ** Cold/Uarn/Hot
3. SUPL Supply Step — —
a. SUEn Supply Step Enable/Disable ** on/oFF
b. dISP Dispenser Options ** Cx or Sx
(1) C2 or S1 Comp. #2/Supply #1 (Design 1) ** on/oFF
(2) C3 or S2 Comp. #3/Supply #2 (Design 1) ** on/oFF
(3) C4 or S3 Comp. #4/Supply #3 (Design 1) ** on/oFF
(4) S4 Supply #4 (Design 1) ** on/oFF
(1) C2 Compartment #2 (Design 2 and 3) ** on/oFF
(2) C3 Compartment #3 (Design 2 and 3) ** on/oFF
(3) C4 Compartment #4 (Design 2 and 3) ** on/oFF
(4) S1 Supply #1 (Design 2 and 3) ** on/oFF
(5) S2 Supply #2 (Design 2 and 3) ** on/oFF
(6) S3 Supply #3 (Design 2 and 3) ** on/oFF
(7) S4 Supply #4 (Design 2 and 3) ** on/oFF
c. SdUr Supply Duration ** —
(1) SEC Seconds ** 0-59
(2) nln Minutes ** 0-9
4. AgSt Agitate Step — —
a. AgEn Agitate Step Enable/Disable ** on/oFF
b. AdUr Agitate Duration (in minutes) ** 1-30
c. HEAt Heat in Agitate (if present) ** oFF/1/2**
5. drAn Drain Step — —
6. SPEn Extract Step Enable/Disable ** on/oFF
a. SSEC Extract Seconds ** 0-59
b. SnIn Extract Minutes ** Int. Extract:
Min. = :30, Max. = 3:59
Final Extract
Min. = :30, Max. = 9:59
c. SSPd Extract Speed (VFD only) ** 1 - 3* (Design 1)
1 - 6* (Design 2 and 3)
c. Cnin Cycle Time 0* 0-255 minutes
5 SUPC Supply/Comp. Disp. Prog. (Design 1) C C (Comp.)/S (Supply)
6 bALr Number of Balance Retries 3 (Design 1) 1-7
(VFD only) 1 (Design 2
and 3)
7 IrA IR Access on on/oFF
8 t FC Fahrenheit/Celsius FAHr FAHr/CEL
9 FH Hot Water Temperature 140°F (60°C) 35°F-194°F / 2°C-90°C
10 FHC Warm Water Temperature 100°F (38°C) 35°F-194°F / 2°C-90°C
11 FC Cold Water Temperature 35°F (2°C) 35°F-194°F / 2°C-90°C
12 Codn Cooldown Enable/Temperature oFF oFF or 50°F-160°F / 10°C-71°C
13 PtEn Production Test Cycle on on/oFF
14 rAEn Manual Rapid Advance on on/oFF
15 nCtd No Cycle Time Display oFF on/oFF
16 PCtd Programmable Cycle Time Display oFF on/oFF
17 SdAd Slow Drain Detection Adjust 0 0-255 seconds
*Refer to the programming manual supplied with the machine for value definition.
**Refer to the cycle chart supplied with the machine for cycle information.