You are on page 1of 1

Points for improvement

 After each rod 9 times dust collector filter need to be flash for better efficiency (if we start
operating lever before completing 9 flash means dust collector efficiency will come down)
 Back hammer to be used only for approx. 9 sec. after that we need to give gap then we can use
again
 Dust collector suction point (near hole collar area) may get struck with small stone that to be
removed after completing every hole
 Engine should not switch off suddenly when engine temperature is high
 While filling Grease pump necessary precaution to be taken to avoid foreign material (small
stone) going inside
 Master to be kept horizontal and visual inspection to be done during pre-start inspection
 Daily Bit need to be checked