After each rod 9 times dust collector filter need to be flash for better efficiency (if we start
operating lever before completing 9 flash means dust collector efficiency will come down)
Back hammer to be used only for approx. 9 sec. after that we need to give gap then we can use
again
Dust collector suction point (near hole collar area) may get struck with small stone that to be
removed after completing every hole
Engine should not switch off suddenly when engine temperature is high
While filling Grease pump necessary precaution to be taken to avoid foreign material (small
stone) going inside
Master to be kept horizontal and visual inspection to be done during pre-start inspection
Daily Bit need to be checked