Power Distribution Electrics

SASSIN INTERNATIONAL ELECTRIC SHANGHAI CO.,LTD.


No.2588 JINHAI RO A D, PUDONG, SHANGHAI, CHINA 201209
TEL: +86-21-50210890 50219970
FAX: +86-21-50217333
E-mail: sassin@sassin.com
Http: //www.sassin.com

R
Better Ele c tric
Better Life
Copyright reserved 3S.13.01 Printed in Oct. 2013
Catalog Classification

3S.13.01 Power Distribution Electrics


Air Circuit Breakers Moulded Case Circuit Breakers
Automatic Transfer Switches Load Break Switches 1
Fuse Combination Switches Low Voltage Fuses
Fuse Disconnector Switches

3S. 13.02 Modular Devices


Miniature Circuit Breakers RCCBs RCD Blocks
RCBOs Main Switches Additional Components
Time Switches Push Buttons and Indicator Lamps
2
Surge Protective Devices Distribution Boxes
Mini Contactors Fuse Holders Accessories

3S. 13.03 Industry Control Electrics


Contactors & Thermal Relays
DC Operated AC Contactors Soft Starters 3
Capacitor Switching Contactors DOL Starters
Motor Protection Circuit Breakers Inverters

3S. 13.04 Switches and Time Relays


Pushbutton Switches Indicators Control Stations
Pushbutton Switch Boxes Micro Switches 4
Rotary Change-over Cam Switches Limit Switches
Toggle Switches Time Relays

3S. 13.05 Power Sources


Company Profile Corporate Culture - Value System Automatic Voltage Stabilizers Voltage Regulators
5
Compensated Voltage Stabilizers
Pure Sine Wave Inverters Back Up UPS
As a leading supplier in the low voltage electrics field, Sassin Better Vision Switching Power Supplies Control Transformers

International Electric Shanghai Co., Ltd is committed to designing Exceeding customers' expectation with remarkable products
and services. Being an enterprise that society respects and staff
and manufacturing advanced circuit protection and intelligent 3S. 13.06 Meters & Electrical Accessories
take pride in.
management products for residential, commercial and industrial Electronic Kilowatt Hour Meters Power Capacitors
Analogue Panel Meters Digital Panel Meters 6
applications. SASSIN company was certified with ISO9001, ISO14000, Sacred Mission Current Transformers Metal Boxes Terminal Blocks
Growing together with top electric enterprise in the world. PC Plug Socket Couplings Electric Bell & Buzzers
and its products were certified with KEMA, CB, VDE, SEMKO, TUV,
Offering integrated electric solutions and services to top clients.
INME TRO ETC. .

The growing and dynamic company SASSIN is on its way to offer


Core Value
Catalog CD
integrated solutions to help individuals and organizations utilize Confidence, Faith, Credit All products in these catalogs listed above are
available in CD.
their energy more safely, reliably, efficiently and sustainably. The
Slogan
innovation culture, which has already been absorbed into the blood
Better Electric, Better Life
of every SASSIN staff, inspires us to continuously bring this world

better electrical product. . Catalog PDF www.sassin.com


Dedicating to the core value " Confidence, Faith, Credit", All catalogs can be downloaded as PDF files from
SASSIN is willing to join hands with every partner to create a better SASSIN website.

world of tomorrow. SASSIN company exports its products to more

than 120 countries and regions around the world. .


Air Circuit Breakers
Series 3SW68

1 Overview

Terminal block

Contents Front drawer base

Busbar

Power Distribution Electrics


3SW68 Air Circuit Breakers P 01-54
Back drawer base
3SW8 Air Circuit Breakers P 55-85

3SM29 Moulded Case Circuit Breakers P 86-113

3SM8N Moulded Case Circuit Breakers P 114-127

3SM8L Moulded Case Circuit Breakers P 128-131

with Earth Leakage Protection

Power Distribution Electrics


Automatic Transfer Switches P 132 Arc chute
3SAQ1 Automatic Transfer Switches P 133-135

3SAQ2 Automatic Transfer Switches P 136-149 Body 1 Body 2

3S.13.01 Power Distribution Electrics 3SAQ3 Automatic Transfer Switches P 150-165


Air Circuit Breakers Moulded Case Circuit Breakers 3SGL Load Break Switches P 166-167 Auxiliary switch
Automatic Transfer Switches Load Break Switches
Fuse Combination Switches Low Voltage Fuses 3SGLR Fuse Combination Switches P 168-189
Fuse Disconnector Switches 3SHR17 Fuse Disconnector Switches P 170-171

RT16 Low Voltage Fuses P 172-174

Intelligent
Instruction of Applications auxiliary switch

Building
Motor
Apartments
Hotels
Hospitals
Offices Shell Current
Transformer
Data Centers and Networks

Industry
Contact system
Mining and Minerals
Automation Industry
Food and Beverage Release
Chemical Industry

Energy and Infrastructures


Operating
Airports mechanism
Oil and Gas
Water
Energy

www.sassin.com 1
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Applications and functions Features and benefits Strength of new material

Incoming-feeder and outgoing-feeder function in Low space requirements

distribution systems Impact strength(Mpa)


Switching and protecting large powers, motors, capacitors, 3SW68 devices are very compact thus require very little
160
generators, transformers, busbars and cables space for installation. Frame A devices (up to 1600 A) fit
140 55%
Overload protection into a 400 mm wide switchgear panel.
120
Short-circuit protection with short delay Frame B,C,D devices (up to 6300 A) are the smallest of their
100
Instantaneous short-circuit protection kind and with their smallest construction width fits into a 80
Used in building, industry, energy and infrastructure 800 mm wide switchgear panel. 60
40
20
Example of comparation with 3SW8 in measurement
Instruction of external structure 0

100% Former materials New materials

80%
Instruction of type code 60% Strength of former insulation materials.
1
60%
Power Distribution Electrics

Strength increased after adopting new insulation materials

Power Distribution Electrics


2 100%
W68 A F 3 L H 200 N using nanotechnology.
3 40%
13 4
20% 40%
Breaking capacity: N; H ; S
12 5
11 0%
10 6
Rated current (A) 3SW68-1600/1600 3SW8-2000/1600
Bending strength(KI/m²)
200, 400, 630, 800, 1000, 1250, 1600 (Frame A)
Four-pole circuit breaker with a drawer as an example 60
1250, 1600, 2000, 2500 (Frame B)
58
2000, 2500, 3200, 4000 (Frame C) Actual body size Reduction of body size
56 20%
4000, 5000, 6300 (Frame D)
54

98 7 Connection type Modular design 52


50
H: Horizontal terminal connection
Components like auxiliary releases, motorized operating 48
1. Terminal of secondary circuit V: Vertical terminal connection
mechanisms,electronic releases, current sensors, auxiliary 46
2. Drawer shelf
Intelligent controller model circuit signaling switches, automatic reset devices, 44
3. Data label L: L type interlocks and engagement operating mechanisms can all
Former materials New materials
4. Manual energy-storage and energy-release M: M type be exchanged or retrofitted in the back ground, thus allowing

5. Switching-ON button H: H type the circuit breaker to be adapted to new, changing Strength of former insulation materials.
required.
6. Indicator of energy-storage and energy-release Strength increased after adopting new insulation materials
Poles: 3: 3P; 4: 4P
using nanotechnology.
7. “Unlocking button” of the three positions (“separated”,
Communication
“test” and “connected”) Installation type
F: Fix type
8. Safety padlock position
The use of modern communication-capable circuit
D: Drawer type
9. Cranking bar breakers opens up completely new possibilities in terms
10. Indicator of switching-on(I) and switching-off(O) Frame of start-up, parameterization, diagnostics, maintenance

11. Intelligent controller A: 3SW68-1600 and operation. This allows varieties of ways of reducing

B: 3SW68-2500 costs and improving productivity in industrial plants,


12. Switching-OFF button
C: 3SW68-4000 buildings and infrastructure projects.
13. Release indicator and resetting button
D: 3SW68-6300

Series code

2 www.sassin.com www.sassin.com 3
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Complete current range and high-breaking capacity Technical specifications:

3SW68-1600 Rated current In(A) 3SW68-1600 Breaking capacity Type 3SW68-1600 3SW68-2500 3SW68-4000 3SW68-6300
Standard IEC60947-2 IEC60947-2 IEC60947-2 IEC60947-2
Icu (kA) Approval CE CE CE CE
Ics (kA) Frame type A B C D
200 Rated frame current In (A)
Icw(kA/1s) 1600 2500 4000 6300
70
400 Number of poles 3,4 3,4 3,4 3,4
60
Class of breaking capacity N H N H N H S N H S
630 50 Rated current In(A) 200 400 630 800 1250 1600 2000 2500 2000 2500 3200 4000 4000 5000 6300
800 40
65 1000 1250 1600
65
30 Rated frequency (Hz) 50/60 50/60 50/60 50/60
42 55 35
1000 30 Rated voltage, Ue (V)
20
400,690 400,690 400,690 400,690
42 50 35
30 Rated insulating voltage Ui (V) 1000 1000 1000 1000
1250 10 35
30 Rated impulsed withstand voltage, Uimp(kV) 12 12 12 12
1600 0
N-pole rated current 100%In 100%In 100%In 100%In
AC400V-N AC400V-H AC690V-N AC690V-H
Rated ultimate short-circuit breaking capacity, Icu
3SW68-2500 Rated current In(A) 3SW68-2500 Breaking capacity (AC) 50-60 Hz 400V O-CO (kA) 65 65 65 85 85 100 120 100 120 150
(AC) 50-60 Hz 690V O-CO (kA) 30 35 50 65 65 85 85 85 100 100
Icu (kA)
Rated operating short-circuit breaking capacity,Ics
Power Distribution Electrics

Power Distribution Electrics


Ics (kA)
(AC) 50-60 Hz 400V O-CO-CO (kA) 42 55 65 85 85 100 100 100 120 150
1000 90
Icw(kA/1s) (AC) 50-60 Hz 690V O-CO-CO (kA) 30 35 50 65 65 85 85 85 100 100
80
70
Rated short-circuit making capacity (peak),Icm
1250
60 (AC) 50-60 Hz 400V (kA) 143 143 143 187 187 220 264 220 264 330
85 (AC) 50-60 Hz 690V (kA)
50 63 73 105 143 143 1 65 165 187 220 220
1600 65 85 65
40 Rated short-time withstand current for 1s Icw (kA)
50
65 85 65 (AC) 50-60 Hz 400V (kA/s) 135
30 42 50 65 85 85 100 100 100 120
2000 50
20 65 65 (AC) 50-60 Hz 690V (kA/s) - - - - 65 85 85 85 100 100
50
10 Making time ms 25-30 25-30 25-30 25-30
2500 0 Max breaking time ms 70 70 70 70
AC400V - N AC400V - H AC690V-N AC690V-H Electrical life (times) in 400V 6500 5000 2000 1000
3SW68-4000 Rated current In(A) 3SW68-4000 Breaking capacity in 690V 3000 2500 1500 800
Mechanical life (times) without maintenance 15000 12500 10000 5000
Icu (kA)
with maintenance 30000 25000 20000 10000
Ics (kA) Mounting position
120 30° 30° 30° 30° 30° 30° 30° 30°
2000 Icw(kA/1s)
100

80
2500
100 120
60 85 85 Installation type Fixed /Drawer Fixed /Drawer Fixed /Drawer Fixed /Drawer
100 100
85 65 85 Dismension (mm) WxHxD WxHxD WxHxD WxHxD
3200 40
100 100
85 65 85 Drawer,horizontal, 3P 248x351x297 347x450x390 440x450x390 769x487x390
20 65 Drawer,horizontal, 4P 318x351x597 442x450x390 556x450x390 995x487x390
4000 Drawer,Vertical, 3P 248x351x297 347x450x390 440x450x390 769x487x390
0
AC400V-N AC400V-H AC400V-S AC690V-N AC690V-H Drawer,Vertical, 4P 318x351x297 442x450x390 556x450x390 995x487x390
Fixed,horizontal, 3P 254x320x194 367x403x308.5 460x403x308.5 785x407x290
3SW68-6300 Rated current In(A) 3SW68-6300 Breaking capacity
Fixed,horizontal, 4P 324x320x194 462x403x308.5 586x403x308.5 1010x407x290
Icu (kA) Fixed,Vertical, 3P 254x320x194 367x403x308.5 460x403x308.5 785x407x290
Fixed,Vertical, 4P 324x320x194 462x403x308.5 586x403x308.5 1010x407x290
Ics (kA)
160 Ambient temperature -5 to +40℃, max. 95 % humidity
140 Icw(kA/1s)
4000 Storage temperature -40 to +75℃
120 Altitude( Max) 2000
100 150
80 100 150
5000 100 100
60 100 85
100 135 100
40 100 85
100 100
20 85
6300
0

AC400V-N AC400V-H AC400V-S AC690V-N AC690V-H

4 www.sassin.com www.sassin.com 5
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Installation and grounding Operation of Draw-out circuit breaker


Insert operation
Installation of draw-out type circuit breaker 1) Pull out the DIN rail by holding on two sides.
Take out the breaker from the drawer-base, then install the drawer-base into the cabinet and fix the drawer-base with four bolts 2) Put the breaker on the din rail according to picture
and washers of corresponding specifications, finally put the breaker into the drawer-base. instruction. Note: the two convex bracket bases of the
Installation of fixed type circuit breaker breaker should be plugged into concave parts. (See right-
Install the circuit breaker into the switchgear cabinet and fix it with four bolts and washers. hand picture XX).
Grounding 3) Draw out the breaker inside to the end (See right-hand
Before grounding of draw-out circuit breaker and fixed circuit breaker, the junction should be wiped clean. picture XX).
Grounding of draw-out type circuit breaker 4) Draw out the handle from the rocker hole and insert the
Use PE conducting wire to connect the grounding bolt on left side plate of drawer-base with the grounding bar of switchgear cabinet. handle hexagon head completely into the drawer-base
Grounding of fixed type circuit breaker rocker hole.
Use PE conducting wire to connect the grounding bolt on left side plate of fixed breaker with the grounding bar of switchgear cabinet. 5) Clockwise rotates the rocker, the three-position button
points at “Test” position, then “Test” position is locked, so
that rocker can not be rotated and no relative movement
Operation
between the breaker and drawer-base.
6) Counterclockwise rotates the three position unlock
Power Distribution Electrics

Power Distribution Electrics


Energy storage operation
button, and then clockwise rotate the handle, the three-
Manual energy storage
position button points at “Connection” position, then the
1) Move the energy storage rocker upward and downward
“Connection” position is locked, so that the handle can not
6-7 times, the storage process is finished when there is no
be rotated and no relative movement between the breaker
counter force.
and drawer-base. Draw out the handle and put it into the
2) When energy storage is finished, the “energy storage-release”
rocker hole (See right-hand picture XXX).
indicator points at the “energy storage” position (ready for
Draw out operation
switching on).
1) Draw out the handle from the rocker hole and insert
Electric energy storage
the handle hexagon head completely into the drawer-base
When control loop is power on, the electro-control mechanism
rocker hole.
will automatically store energy (Control circuit is connected
2) Counterclockwise rotates the three-position button,
to automatic pre-storage form).
and then clockwise rotate the handle. Firstly, move breaker
from “Connection” position to “Test” position, then the “Test”
Switch on and switch off operation
position is locked, so that the handle can not be rotated and
Manual switch on and switch off
no relative movement between the breaker and drawer-base
1) Switch on
(See right-hand picture XXXX).
When the circuit breaker is switched off and storing energy,
3) Counterclockwise rotates three position unlock button,
and the under-voltage release is closed (If equipped with
and then counterclockwise rotates the handle, the three
under-voltage release), push the black I button, the breaker
position button points at “Separation” position
is switched on. The switch indicator shifts O to I, “energy
4) Draw out the handle and draw out the breaker according
storage-release” indicator turns storage into release condition.
to picture instruction.
2) Switch off
Note: Because the center of gravity moves forward, the
When the circuit breaker is switched on, push the red O button,
circuit should be protected against tilting and falling.
the breaker will switch off. The switch indicator turns I to O.
5) Draw out the breaker according to the picture XXX, and
Automatic switch on and switch off
then put the DIN rail back to the original place.
1) Switch on
When the circuit breaker is switched off and storing energy,
Note: when the breaker is rocked to “Separation”, “Test”
the under-voltage release is switched on (If equipped with
and “Connection” positions, the corresponding position is
under-voltage release), the breaker will be switched on after
automatically locked (the rocker can not be moved), it can
rated voltage is applied on the closing coil.
be unlocked by means of counterclockwise rotating the
2) Switch off
three-position unlock button.
When the switch is closed, the breaker will be switched off
after rated voltage is applied on the shunt release.

6 www.sassin.com www.sassin.com 7
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

A2S Curve Note: The ACB is to calibrated at 40℃ , special application please refer to the table above and the curve below

6
l³t(A³s×10 )
1200 5000
741
4800
1100
4600
1000 In=1000A 4400
4200
900
4000
In=4000A

Rated current ( A )
341
800 In=800A 3800

Rated current ( A )
3600
700
In=630A 3400
200 600 3200
190 In=3200A
180 3000
500
170 2800
160
400 In=400A
150 2600
140 In=2500A
130 2400
300
120 2200
110 In=200A
In=2000A
100 200 2000
Power Distribution Electrics

Power Distribution Electrics


90
80 1800
100
70
60 40 45 50 55 60 65 70
50 0
40 40 45 50 55 60 65 70
30
20 Ambient temperature(℃)
10 Ambient temperature(℃)
20 40 60 80 100 120 ls(kA) 3SW68-3200, 3SW68-4100
3SW68-1000
ls: prospective symmetrical current (of an a.c circuit)

Temperature compensation correction


2000 7000
In=2000A
1900 6800
Ambient 3SW68-3200 1800 6600
Standard 3SW68-1000 3SW68-2000
temperature 3SW68-4000 1700 6400
In=1600A
40℃ 200 400 630 800 1000 630 800 1000 1250 1600 2000 2000 2500 3200 4000 1600 6200
45℃ 195 395 623 790 985 630 800 1000 1250 1600 1900 2000 2400 3000 3800 1500 6000 In=6300A

Rated current ( A )
50℃ 192 384 605 768 960 630 800 1000 1250 1500 1900 2000 2300 3000 3600 1400 5800
IEC/EN60947-2 In=1250A

Rated current ( A )
55℃ 182 328 584 725 924 630 800 1000 1200 1500 1800 2000 2200 2800 3400 1300 5600
60℃ 174 248 548 696 870 610 800 1000 1150 1300 1700 2000 2200 2800 3200 1200 5400
65℃ 163 192 500 620 810 610 800 1000 1150 1300 1650 2000 2200 2800 3200 1100 5200
In=1000A In=5000A
1000 5000
900 4800
In=800A
800 4600
700 In=630A 4400
600 4200
In=4000A
500 4000
400 3800

40 45 50 55 60 65 70 40 45 50 55 60 65 70

Ambient temperature(℃) Ambient temperature(℃)


3SW68-2000 3SW68-6300

8 www.sassin.com www.sassin.com 9
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Installation and grounding

Selective protection between 3SM8N and 3SW68

Circuit breaker 3SW68-2000 3SW68-2000 3SW68-3200 3SW68-4000 3SW68-6300

Rated
400 630 800 1000 1250 1600 2000 2000 2500 3200 3200 4000 4000 5000 6300
current(A)
Default setting ratings
3.2 5.04 6.4 8 10 16 16 20 25.6 25.6 32 32 40 50.4
of short time-delay 8In(kA)
Downstream Upstream Setting
0.4~6 0.63~9.45 0.8~12 1~15 1.25~18.75 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
range(kA)
Delayed tripping 0.1, 0.2, 0.3, 0.4 0.1, 0.2, 0.3, 0.4
time(s)
Returnable time 0.06, 0.14, 0.23, 0.35 0.06, 0.14, 0.23, 0.35
Frame size Rated Instantaneous
rated current current(A) serring ratings(kA)
0.16 0.4~6 0.63~9.45 0.8~12 1~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
16
0.19(motor) 0.4~6 0.63~9.45 0.8~12 1~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
0.2 0.4~6 0.63~9.45 0.8~12 1~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
Power Distribution Electrics

Power Distribution Electrics


20
0.24(motor) 0.4~6 0.63~9.45 0.8~12 1~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
0.25 0.4~6 0.63~9.45 0.8~12 1~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
25
0.30(motor) 0.414~6 0.63~9.45 0.8~12 1~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
0.32 0.4416~6 0.63~9.45 0.8~12 1~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
32
0.38(motor) 0.5224~6 0.63~9.45 0.8~12 1~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
0.40 0.552~6 0.63~9.45 0.8~12 1~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
40
0.48(motor) 0.6624~6 0.6624~9.45 0.8~12 1~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
3SM8N-125
0.50 0.69~6 0.69~9.45 0.8~12 1~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
50
0.60(motor) 0.828~6 0.828~9.45 0.828~12 1~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
0.63 0.8694~6 0.8694~9.45 0.8694~12 1~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
63
0.75(motor) 1.035~6 1.035~9.45 1.035~12 1.035~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
0.80 1.104~6 1.104~9.45 1.104~12 1.104~15 1.25~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
80
0.96(motor) 1.325~6 1.325~9.45 1.325~12 1.325~15 1.325~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
1.0 1.38~6 1.38~9.45 1.38~12 1.38~15 1.38~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
100
1.2(motor) 1.656~6 1.656~9.45 1.656~12 1.656~15 1.656~18.75 1.656~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
1.25 1.725~6 1.725~9.45 1.725~12 1.725~15 1.725~18.75 1.725~24 1.725~30 1.725~30 1.725~37.7 1.725~48 1.725~48 1.725~60 1.725~60 1.725~75 1.725~94.5
125
1.5(motor) 2.07~6 2.07~9.45 2.07~12 2.07~15 2.07~18.72 2.07~24 2.07~30 2.07~30 2.07~37.7 2.07~48 2.07~48 2.07~60 2.07~60 2.07~75 2.07~94.5
1.0 1.38~6 1.38~9.45 1.38~12 1.38~15 1.38~18.75 1.6~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
100
1.2(motor) 1.656~6 1.656~9.45 1.656~12 1.656~15 1.656~18.75 1.656~24 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
1.6 2.208~6 2.208~9.45 2.208~12 2.208~15 2.208~18.75 2.208~24 2.208~30 2.208~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
160
1.92(motor) 2.65~6 2.65~9.45 2.65~12 2.65~15 2.65~18.75 2.65~24 2.65~30 2.65~30 2.65~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
3SM8N-250
2.0 2.76~6 2.76~9.45 2.76~12 2.76~15 2.76~18.75 2.76~24 2.76~30 2.76~30 2.76~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
200
2.4(motor) 3.312~6 3.312~9.45 3.312~12 3.312~15 3.312~18.75 3.312~24 3.312~30 3.312~30 3.312~37.7 3.312~48 3.312~48 4~60 4~60 5~75 6.3~94.5
2.5 3.45~6 3.45~9.45 3.45~12 3.45~15 3.45~18.75 3.45~24 3.45~30 3.45~30 3.45~37.7 3.45~48 3.45~48 4~60 4~60 5~75 6.3~94.5
250
3.0(motor) 4.14~6 4.14~9.45 4.14~12 4.14~15 4.14~18.75 4.14~24 4.14~30 4.14~30 4.14~37.7 4.14~48 4.14~48 4.14~60 4.14~60 5~75 6.3~94.5
2.5 3.45~6 3.45~9.45 3.45~12 3.45~15 3.45~18.75 3.45~24 3.45~30 3.45~30 3.45~37.7 3.45~48 3.45~48 4~60 4~60 5~75 6.3~94.5
250
3.0(motor) 3.45~6 3.45~9.45 3.45~12 3.45~15 3.45~18.75 4.14~24 4.14~30 4.14~30 4.14~37.7 4.14~48 4.14~48 4.14~60 4.14~60 5~75 6.3~94.5
3.15 4.347~6 4.347~9.45 4.347~12 4.347~15 4.347~18.75 4.347~24 4.347~30 4.347~30 4.347~37.7 4.347~48 4.347~48 4.347~60 4.347~60 5~75 6.3~94.5
315
3.78(motor) 5.216~6 5.216~9.45 5.216~12 5.216~15 5.216~18.75 5.216~24 5.216~30 5.216~30 5.216~37.7 5.216~48 5.216~48 5.216~60 5.216~60 5.216~75 6.3~94.5
3.5 4.83~6 4.83~9.45 4.83~12 4.83~15 4.83~18.75 4.83~24 4.83~30 4.83~30 4.83~37.7 4.83~48 4.83~48 4.83~60 4.83~60 5~75 6.3~94.5
350
4.2(motor) 5.796~6 5.796~9.45 5.796~12 5.796~15 5.796~18.75 5.796~24 5.796~30 5.796~30 5.796~37.7 5.796~48 5.796~48 5.796~60 5.796~60 5.796~75 6.3~94.5
3SM8N-630
4.0 5.52~6 5.52~9.45 5.52~12 5.52~15 5.52~18.75 5.52~24 5.52~30 5.52~30 5.52~37.7 5.52~48 5.52~48 5.52~60 5.52~60 5.52~75 6.3~94.5
400
4.8(motor) 6.24~9.45 6.24~12 6.24~15 6.24~18.75 6.624~24 6.624~30 6.624~30 6.624~37.7 6.624~48 6.624~48 6.624~60 6.624~60 6.24~75 6.624~94.5
5.0 6.9~9.45 6.9~12 6.9~15 6.9~18.75 6.9~24 6.9~30 6.9~30 6.9~37.7 6.9~48 6.9~48 6.9~60 6.9~60 6.9~75 6.9~94.5
500
6.0(motor) 8.28~9.45 8.28~12 8.28~15 8.28~18.75 8.28~24 8.28~30 8.28~30 8.28~37.7 8.28~48 8.28~48 8.28~60 8.28~60 8.28~75 8.28~94.5
6.3 8.694~9.45 8.694~12 8.694~15 8.694~18.75 8.694~24 8.694~30 8.694~30 8.694~37.7 8.694~48 8.694~48 8.694~60 8.694~60 8.694~75 8.694~94.5
630
7.56(motor) 8.694~9.45 10.44~12 10.44~15 10.44~18.75 10.44~24 10.44~30 10.44~30 10.44~37.7 10.44~48 10.44~48 10.44~60 10.44~60 10.44~75 10.44~94.5

10 www.sassin.com www.sassin.com 11
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Selective protection between 3SM8N and 3SW68

Circuit breaker 3SW68-2000 3SW68-2000 3SW68-3200 3SW68-4000 3SW68-6300

Rated
400 630 800 1000 1250 1600 2000 2000 2500 3200 3200 4000 4000 5000 6300
current(A)
Default setting ratings
3.2 5.04 6.4 8 10 16 16 20 25.6 25.6 32 32 40 50.4
of short time-delay 8In(kA)
Downstream Upstream Setting
0.4~6 0.63~9.45 0.8~12 1~15 1.25~18.75 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
range(kA)
Delayed tripping 0.1, 0.2, 0.3, 0.4 0.1, 0.2, 0.3, 0.4
time(s)
Returnable time 0.06, 0.14, 0.23, 0.35 0.06, 0.14, 0.23, 0.35
Frame size Rated Instantaneous
rated current current(A) setting ratings(kA)
6.3 6.348~9.45 8.694~12 8.694~15 8.694~18.75 8.694~24 8.694~30 8.694~30 8.694~37.7 8.694~48 8.694~48 8.694~60 8.694~60 8.694~75 8.694~94.5
630
7.56(motor) 10.44~12 10.44~15 10.44~18.75 10.44~24 10.44~30 10.44~30 10.44~37.7 10.44~48 10.44~48 10.44~60 10.44~60 10.44~75 10.44~94.5
7.0 9.66~12 9.66~15 9.66~18.75 9.66~24 9.66~30 9.66~30 9.66~37.7 9.66~48 9.66~48 9.66~60 9.66~60 9.66~75 9.66~94.5
3SM8N-800 700
8.4(motor) 11.59~12 11.59~15 11.59~18.75 11.59~24 11.59~30 11.59~30 11.59~37.7 11.59~48 11.59~48 11.59~60 11.59~60 11.59~75 11.59~94.5
Power Distribution Electrics

8.0 11.04~12 11.04~15 1.38~18.75 11.04~24 11.04~30 11.04~30 11.04~37.7 11.04~48 11.04~48 11.04~60 11.04~60 11.04~75 11.04~94.5

Power Distribution Electrics


800
9.6(motor) 6.348~12 13.25~15 1.656~18.75 13.25~24 13.25~30 13.25~30 13.25~37.7 13.25~48 13.25~48 13.25~60 13.25~60 13.25~75 13.25~94.5

Selective protection in 3SW68

Circuit breaker 3SW68-2000 3SW68-2000 3SW68-3200 3SW68-4000 3SW68-6300

Rated
400 630 800 1000 1250 1600 2000 2000 2500 3200 3200 4000 4000 5000 6300
current(A)
Default setting ratings
3.2 5.04 6.4 8 10 16 16 20 25.6 25.6 32 32 40 50.4
of short time-delay 8In(kA)
Downstream Upstream Setting
0.4~6 0.63~9.45 0.8~12 1~15 1.25~18.75 2~30 2~30 2.5~37.7 3.2~48 3.2~48 4~60 4~60 5~75 6.3~94.5
range(kA)
Delayed tripping 0.1, 0.2, 0.3, 0.4 0.1, 0.2, 0.3, 0.4
time(s)
Returnable time 0.06, 0.14, 0.23, 0.35 0.06, 0.14, 0.23, 0.35
Frame size Rated Default instantaneous
rated current current(A) setting ratings 12In(kA)
400 4.8 9.998~12 6.348~15 6.348~18.75 6.348~24 6.348~30 6.348~30 6.348~37.7 6.348~48 6.348~48 6.348~60 6.348~60 6.348~75 6.348~94.5
630 7.56 9.998~15 9.998~18.75 9.998~24 9.998~30 9.998~30 9.998~37.7 9.998~48 9.998~48 9.998~60 9.998~60 9.998~75 9.998~94.5
800 9.6 12.696~15 12.696~18.75 12.696~24 12.696~30 12.696~30 12.696~37.7 12.696~48 12.696~48 12.696~60 12.696~60 12.696~75 12.696~94.5
1000 12 15.87~18.75 15.87~24 15.87~30 15.87~30 15.87~37.7 15.87~48 15.87~48 15.87~60 15.87~60 15.87~75 15.87~94.5
3SW68-2000 1250 15 19.837~24 19.837~30 19.837~30 19.837~37.7 19.837~48 19.837~48 19.837~60 19.837~60 19.837~75 19.837~94.5
3SW68-3200 1600 19.2 25.392~30 25.392~30 25.392~37.7 25.392~48 25.392~48 25.392~60 25.392~60 25.392~75 25.392~94.5
3SW68-4000 2000 24 31.74~37.7 31.74~48 31.74~48 31.74~60 31.74~60 31.74~75 31.74~94.5
3SW68-6300 2000 24 31.74~37.7 31.74~48 31.74~48 31.74~60 31.74~60 31.74~75 31.74~94.5
2500 30 39.675~48 39.675~48 39.675~60 39.675~60 39.675~75 39.675~94.5
3200 38.4 50.784~60 50.784~60 50.784~75 50.784~94.5
3200 38.4 50.784~60 50.784~60 50.784~75 50.784~94.5
4000 48 63.48~75 63.48~94.5
4000 48 63.48~75 63.48~94.5
5000 60 79.35~94.5
6300 75

Note:It can satisfy the selective protection if only the short time-delay setting value of the superior breaker 1.32 times more than the
subordinate breaker, when the instantaneous setting value is adjustive.

12 www.sassin.com www.sassin.com 13
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Intelligent controller characteristics Selection and ordering data

Function Intelligent controller model Frame A L type controller

3SW68-1600 N type Horizontal terminal connection


3SW68-L 3SW68-M 3SW68-H
Rated current Number of Fixed type Drawer type
Basic protection 65kA
In(A) poles Type code Order code Type code Order code
Overload protection L 200 3P W68AF 3LH200N 28057 W68AD 3LH200N 28099
Short-circuit protection with short delay S 4P W68AF 4LH200N 28058 W68AD 4LH200N 28100
400 3P W68AF 3LH400N 28059 W68AD 3LH400N 28101
Instantaneous short-circuit protection I
4P W68AF 4LH400N 28060 W68AD 4LH400N 28102
Ground fault protection G
630 3P W68AF 3LH630N 28061 W68AD 3LH630N 28103
Neutral pole protection N 4P W68AF 4LH630N 28062 W68AD 4LH630N 28104
Additional functions 800 3P W68AF 3LH800N 28063 W68AD 3LH800N 28105

MCR Function 4P W68AF 4LH800N 28064 W68AD 4LH800N 28106


1000 3P W68AF 3LH1000N 28065 W68AD 3LH1000N 28107
Thermal memory
4P W68AF 4LH1000N 28066 W68AD 4LH1000N 28108
Contact loss indicator 1250 3P 28067 28109
W68AF 3LH1250N W68AD 3LH1250N
Self-diagnostic function 4P W68AF 4LH1250N 28068 W68AD 4LH1250N 28110
Fault memory 1600 3P W68AF 3LH1600N 28069 W68AD 3LH1600N 28111
4P W68AF 4LH1600N 28070 W68AD 4LH1600N 28112
Power Distribution Electrics

Power Distribution Electrics


Test function
Vertical terminal connection
Zone Selective Interlocking
200 3P 3W68AF 3LV200N 28071 W68AD 3LV200N 28113
Closing counting 4P 4W68AF 4LV200N 28072 W68AD 4LV200N 28114
Parameter display 400 3P 3W68AF 3LV400N 28073 W68AD 3LV400N 28115
4P 4W68AF 4LV400N 28074 W68AD 4LV400N 28116
Fault trip display
630 3P 3W68AF 3LV630N 28075 W68AD 3LV630N 28117
Load monitoring display
4P 4W68AF 4LV630N 28076 W68AD 4LV630N 28118
Current display 800 3P 3W68AF 3LV800N 28077 W68AD 3LV800N 28119
Time display 4P 4W68AF 4LV800N 28078 W68AD 4LV800N 28120
1000 3P 3W68AF 3LV1000N 28079 W68AD 3LV1000N 28121
Measurement
4P 4W68AF 4LV1000N 28080 W68AD 4LV1000N 28122
Current measurement
1250 3P 3W68AF 3LV1250N 28081 W68AD 3LV1250N 28123
Voltage measurement 4P 4W68AF 4LV1250N 28082 W68AD 4LV1250N 28124
Frequency measurement 1600 3P 3W68AF 3LV1600N 28083 W68AD 3LV1600N 28125
Power measurements 4P 4W68AF 4LV1600N 28084 W68AD 4LV1600N 28126
H type Horizontal terminal connection
Power factor measurement
65kA 200 3P W68AF 3LH200H 28141 W68AD 3LH200H 28183
Phase sequence detection 4P W68AF 4LH200H 28142 W68AD 4LH200H 28184
Imbalance function 400 3P W68AF 3LH400H 28143 W68AD 3LH400H 28185
Energy measurement 4P W68AF 4LH400H 28144 W68AD 4LH400H 28186
630 3P W68AF 3LH630H 28145 W68AD 3LH630H 28187
Harmonic measurement
4P W68AF 4LH630H 28146 W68AD 4LH630H 28188
Protection 800 3P W68AF 3LH800H 28147 W68AD 3LH800H 28189
Overvoltage protection 4P W68AF 4LH800H 28148 W68AD 4LH800H 28190
Undervoltage protection 1000 3P W68AF 3LH1000H 28149 W68AD 3LH1000H 28191
4P W68AF 4LH1000H 28150 W68AD 4LH1000H 28192
Imbalance protection
1250 3P W68AF 3LH1250H 28151 W68AD 3LH1250H 28193
Over frequency protection
4P W68AF 4LH1250H 28152 W68AD 4LH1250H 28194
Under-frequency protection 1600 3P W68AF 3LH1600H 28153 W68AD 3LH1600H 28195
Phase sequence protection 4P W68AF 4LH1600H 28154 W68AD 4LH1600H 28196

Inverse power protection


Communication
Communication Interface
Achieve communication through MODBUS
Achieve communication through PROFIBUS

Achieve communication through device net

Note: “ ” available “ ” selectable ” ” unavailable

14 www.sassin.com www.sassin.com 15
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Frame A L type controller Frame A M type controller


H type Vertical terminal connection H type Horizontal terminal connection
3SW68-1600 3SW68-1600
65kA Rated current Number of Fixed type Drawer type 65kA Rated current Number of Fixed type Drawer type
In(A) poles Type code Order code Type code Order code In(A) poles Type code Order code Type code Order code
200 3P W68AF 3LV200H 28155 W68AD 3LV200H 28197 200 3P W68AF 3MH200H 28309 W68AD 3MH200H 28351
4P W68AF 4LV200H 28156 W68AD 4LV200H 28198 4P W68AF 4MH200H 28310 W68AD 4MH200H 28352
400 3P W68AF 3LV400H 28157 W68AD 3LV400H 28199 400 3P W68AF 3MH400H 28311 W68AD 3MH400H 28353
4P W68AF 4LV400H 28158 W68AD 4LV400H 28200 4P W68AF 4MH400H 28312 W68AD 4MH400H 28354
630 3P W68AF 3LV630H 28159 W68AD 3LV630H 28201 630 3P W68AF 3MH630H 28313 W68AD 3MH630H 28355
4P W68AF 4LV630H 28160 W68AD 4LV630H 28202 4P W68AF 4MH630H 28314 W68AD 4MH630H 28356
800 3P W68AF 3LV800H 28161 W68AD 3LV800H 28203 800 3P W68AF 3MH800H 28315 W68AD 3MH800H 28357
4P W68AF 4LV800H 28162 W68AD 4LV800H 28204 4P W68AF 4MH800H 28316 W68AD 4MH800H 28358
1000 3P W68AF 3LV1000H 28163 W68AD 3LV1000H 28205 1000 3P W68AF 3MH1000H 28317 W68AD 3MH1000H 28359
4P W68AF 4LV1000H 28164 W68AD 4LV1000H 28206 4P W68AF 4MH1000H 28318 W68AD 4MH1000H 28360
1250 3P W68AF 3LV1250H 28165 W68AD 3LV1250H 28207 1250 3P W68AF 3MH1250H 28319 W68AD 3MH1250H 28361
4P W68AF 4LV1250H 28166 W68AD 4LV1250H 28208 4P W68AF 4MH1250H 28320 W68AD 4MH1250H 28362
1600 3P W68AF 3LV1600H 28167 W68AD 3LV1600H 28209 1600 3P W68AF 3MH1600H 28321 W68AD 3MH1600H 28363
4P W68AF 4LV1600H 28168 W68AD 4LV1600H 28210 4P W68AF 4MH1600H 28322 W68AD 4MH1600H 28364
Vertical terminal connection
M type controller 200 3P W68AF 3MV200H 28323 W68AD 3MV200H 28365
Power Distribution Electrics

Power Distribution Electrics


N type Horizontal terminal connection 4P W68AF 4MV200H 28324 W68AD 4MV200H 28366
65kA 200 3P W68AF 3MH200N 28225 W68AD 3MH200N 28267 400 3P W68AF 3MV400H 28325 W68AD 3MV400H 28367
4P W68AF 4MH200N 28226 W68AD 4MH200N 28268 4P W68AF 4MV400H 28326 W68AD 4MV400H 28368
400 3P W68AF 3MH400N 28227 W68AD 3MH400N 28269 630 3P W68AF 3MV630H 28327 W68AD 3MV630H 28369
4P W68AF 4MH400N 28228 W68AD 4MH400N 28270 4P W68AF 4MV630H 28328 W68AD 4MV630H 28370
630 3P W68AF 3MH630N 28229 W68AD 3MH630N 28271 800 3P W68AF 3MV800H 28329 W68AD 3MV800H 28371
4P W68AF 4MH630N 28230 W68AD 4MH630N 28272 4P W68AF 4MV800H 28330 W68AD 4MV800H 28372
800 3P W68AF 3MH800N 28231 W68AD 3MH800N 28273 1000 3P W68AF 3MV1000H 28331 W68AD 3MV1000H 28373
4P W68AF 4MH800N 28232 W68AD 4MH800N 28274 4P W68AF 4MV1000H 28332 W68AD 4MV1000H 28374
1000 3P W68AF 3MH1000N 28233 W68AD 3MH1000N 28275 1250 3P W68AF 3MV1250H 28333 W68AD 3MV1250H 28375
4P W68AF 4MH1000N 28234 W68AD 4MH1000N 28276 4P W68AF 4MV1250H 28334 W68AD 4MV1250H 28376
1250 3P W68AF 3MH1250N 28235 W68AD 3MH1250N 28277 1600 3P W68AF 3MV1600H 28335 W68AD 3MV1600H 28377
4P W68AF 4MH1250N 28236 W68AD 4MH1250N 28278 4P W68AF 4MV1600H 28336 W68AD 4MV1600H 28378
1600 3P W68AF 3MH1600N 28237 W68AD 3MH1600N 28279
4P W68AF 4MH1600N 28238 W68AD 4MH1600N 28280 H type controller
Vertical terminal connection N type Horizontal terminal connection
200 3P W68AF 3MV200N 28239 W68AD 3MV200N 28281 65kA 200 3P W68AF 3HH200N 28393 W68AD 3HH200N 28435
4P W68AF 4MV200N 28240 W68AD 4MV200N 28282 4P W68AF 4HH200N 28394 W68AD 4HH200N 28436
400 3P W68AF 3MV400N 28241 W68AD 3MV400N 28283 400 3P W68AF 3HH400N 28395 W68AD 3HH400N 28437
4P W68AF 4MV400N 28242 W68AD 4MV400N 28284 4P W68AF 4HH400N 28396 W68AD 4HH400N 28438
630 3P W68AF 3MV630N 28243 W68AD 3MV630N 28285 630 3P W68AF 3HH630N 28397 W68AD 3HH630N 28439
4P W68AF 4MV630N 28244 W68AD 4MV630N 28286 4P W68AF 4HH630N 28398 W68AD 4HH630N 28440
800 3P W68AF 3MV800N 28245 W68AD 3MV800N 28287 800 3P W68AF 3HH800N 28399 W68AD 3HH800N 28441
4P W68AF 4MV800N 28246 W68AD 4MV800N 28288 4P W68AF 4HH800N 28400 W68AD 4HH800N 28442
1000 3P W68AF 3MV1000N 28247 W68AD 3MV1000N 28289 1000 3P W68AF 3HH1000N 28401 W68AD 3HH1000N 28443
4P W68AF 4MV1000N 28248 W68AD 4MV1000N 28290 4P W68AF 4HH1000N 28402 W68AD 4HH1000N 28444
1250 3P W68AF 3MV1250N 28249 W68AD 3MV1250N 28291 1250 3P W68AF 3HH1250N 28403 W68AD 3HH1250N 28445
4P W68AF 4MV1250N 28250 W68AD 4MV1250N 28292 4P W68AF 4HH1250N 28404 W68AD 4HH1250N 28446
1600 3P W68AF 3MV1600N 28251 W68AD 3MV1600N 28293 1600 3P W68AF 3HH1600N 28405 W68AD 3HH1600N 28447
4P W68AF 4MV1600N 28252 W68AD 4MV1600N 28294 4P W68AF 4HH1600N 28406 W68AD 4HH1600N 28448

16 www.sassin.com www.sassin.com 17
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Frame A H type controller Frame B L type controller

3SW68-1600 Vertical terminal connection 3SW68-2500 N type Horizontal terminal connection


Rated current Number of Fixed type Drawer type 65kA Rated current Number of Fixed type Drawer type
In(A) poles Type code Order code Type code Order code In(A) poles Type code Order code Type code Order Code
200 3P W68AF 3HV200N 28407 W68AD 3HV200N 28449 1250 3P W68BF 3LH1250N 28561 W68BD 3LH1250N 28577
4P W68AF 4HV200N 28408 W68AD 4HV200N 28450 4P W68BF 4LH1250N 28562 W68BD 4LH1250N 28578
400 3P W68AF 3HV400N 28409 W68AD 3HV400N 28451 1600 3P W68BF 3LH1600N 28563 W68BD 3LH1600N 28579
4P W68AF 4HV400N 28410 W68AD 4HV400N 28452 4P W68BF 4LH1600N 28564 W68BD 4LH1600N 28580
630 3P W68AF 3HV630N 28411 W68AD 3HV630N 28453 2000 3P W68BF 3LH2000N 28565 W68BD 3LH2000N 28581
4P W68AF 4HV630N 28412 W68AD 4HV630N 28454 4P W68BF 4LH2000N 28566 W68BD 4LH2000N 28582
800 3P W68AF 3HV800N 28413 W68AD 3HV800N 28455 2500 3P W68BF 3LH2500N 28567 W68BD 3LH2500N 28583
4P W68AF 4HV800N 28414 W68AD 4HV800N 28456 4P W68BF 4LH2500N 28568 W68BD 4LH2500N 28584
1000 3P W68AF 3HV1000N 28415 W68AD 3HV1000N 28457 Vertical terminal connection
4P W68AF 4HV1000N 28416 W68AD 4HV1000N 28458 1250 3P W68BF 3LV1250N 28569 W68BD 3LV1250N 28585
1250 3P W68AF 3HV1250N 28417 W68AD 3HV1250N 28459 4P W68BF 4LV1250N 28570 W68BD 4LV1250N 28586
4P W68AF 4HV1250N 28418 W68AD 4HV1250N 28460 1600 3P W68BF 3LV1600N 28571 W68BD 3LV1600N 28587
1600 3P W68AF 3HV1600N 28419 W68AD 3HV1600N 28461 4P W68BF 4LV1600N 28572 W68BD 4LV1600N 28588
4P W68AF 4HV1600N 28420 W68AD 4HV1600N 28462 2000 3P W68BF 3LV2000N 28573 W68BD 3LV2000N 28589
H type Horizontal terminal connection 4P W68BF 4LV2000N 28574 W68BD 4LV2000N 28590

65kA 200 3P W68AF 3HH200H 28477 W68AD 3HH200H 28519 2500 3P W68BF 3LV2500N 28575 W68BD 3LV2500N 28591
Power Distribution Electrics

Power Distribution Electrics


4P W68AF 4HH200H 28478 W68AD 4HH200H 28520 4P W68BF 4LV2500N 28576 W68BD 4LV2500N 28592
400 3P W68AF 3HH400H 28479 W68AD 3HH400H 28521 H type Horizontal terminal connection
4P W68AF 4HH400H 28480 W68AD 4HH400H 28522 85kA 1250 3P W68BF 3LH1250H 28593 W68BD 3LH1250H 28609
630 3P W68AF 3HH630H 28481 W68AD 3HH630H 28523 4P W68BF 4LH1250H 28594 W68BD 4LH1250H 28610
4P W68AF 4HH630H 28482 W68AD 4HH630H 28524 1600 3P W68BF 3LH1600H 28595 W68BD 3LH1600H 28611
800 3P W68AF 3HH800H 28483 W68AD 3HH800H 28525 4P W68BF 4LH1600H 28596 W68BD 4LH1600H 28612
4P W68AF 4HH800H 28484 W68AD 4HH800H 28526 2000 3P W68BF 3LH2000H 28597 W68BD 3LH2000H 28613
1000 3P W68AF 3HH1000H 28485 W68AD 3HH1000H 28527 4P W68BF 4LH2000H 28598 W68BD 4LH2000H 28614
4P W68AF 4HH1000H 28486 W68AD 4HH1000H 28528 2500 3P W68BF 3LH2500H 28599 W68BD 3LH2500H 28615
1250 3P W68AF 3HH1250H 28487 W68AD 3HH1250H 28529 4P W68BF 4LH2500H 28600 W68BD 4LH2500H 28616
4P W68AF 4HH1250H 28488 W68AD 4HH1250H 28530 Vertical terminal connection
1600 3P W68AF 3HH1600H 28489 W68AD 3HH1600H 28531 1250 3P W68BF 3LV1250H 28601 W68BD 3LV1250H 18214
4P W68AF 4HH1600H 28490 W68AD 4HH1600H 28532 4P W68BF 4LV1250H 28602 W68BD 4LV1250H 18215
Vertical terminal connection 1600 3P W68BF 3LV1600H 28603 W68BD 3LV1600H 18216
200 3P W68AF 3HV200H 28491 W68AD 3HV200H 28533 4P W68BF 4LV1600H 28604 W68BD 4LV1600H 18217
4P W68AF 4HV200H 28492 W68AD 4HV200H 28534 2000 3P W68BF 3LV2000H 28605 W68BD 3LV2000H 18218
400 3P W68AF 3HV400H 28493 W68AD 3HV400H 28535 4P W68BF 4LV2000H 28606 W68BD 4LV2000H 18219
4P W68AF 4HV400H 28494 W68AD 4HV400H 28536 2500 3P W68BF 3LV2500H 28607 W68BD 3LV2500H 18220
630 3P W68AF 3HV630H 28495 W68AD 3HV630H 28537 4P W68BF 4LV2500H 28608 W68BD 4LV2500H 18221
4P W68AF 4HV630H 28496 W68AD 4HV630H 28538
800 3P W68AF 3HV800H 28497 W68AD 3HV800H 28539 M type controller
4P W68AF 4HV800H 28498 W68AD 4HV800H 28540 N type Horizontal terminal connection
1000 3P W68AF 3HV1000H 28499 W68AD 3HV1000H 28541 65kA 1250 3P W68BF 3MH1250N 18222 W68BD 3MH1250N 18238
4P W68AF 4HV1000H 28500 W68AD 4HV1000H 28542 4P W68BF 4MH1250N 18223 W68BD 4MH1250N 18239
1250 3P W68AF 3HV1250H 28501 W68AD 3HV1250H 28543 1600 3P W68BF 3MH1600N 18224 W68BD 3MH1600N 18240
4P W68AF 4HV1250H 28502 W68AD 4HV1250H 28544 4P W68BF 4MH1600N 18225 W68BD 4MH1600N 18241
1600 3P W68AF 3HV1600H 28503 W68AD 3HV1600H 28545 2000 3P W68BF 3MH2000N 18226 W68BD 3MH2000N 18242
4P W68AF 4HV1600H 28504 W68AD 4HV1600H 28546 4P W68BF 4MH2000N 18227 W68BD 4MH2000N 18243
2500 3P W68BF 3MH2500N 18228 W68BD 3MH2500N 18244
4P W68BF 4MH2500N 18229 W68BD 4MH2500N 18245

18 www.sassin.com www.sassin.com 19
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Frame B Mtype controller Frame B H type controller


N type Vertical terminal connection H type Horizontal terminal connection
3SW68-2500 3SW68-2500
65kA Rated current Number of Fixed type Drawer type 85kA Rated current Number of Fixed type Drawer type
In(A) poles Type code Order code Type Code Order Code In(A) poles Type code Order code Type code Order code
1250 3P W68BF 3MV1250N 18230 W68BD 3MV1250N 18246 1250 3P W68BF 3HH1250H 18318 W68BD 3HH1250H 18334
4P W68BF 4MV1250N 18231 W68BD 4MV1250N 18247 4P W68BF 4HH1250H 18319 W68BD 4HH1250H 18335
1600 3P W68BF 3MV1600N 18232 W68BD 3MV1600N 18248 1600 3P W68BF 3HH1600H 18320 W68BD 3HH1600H 18336
4P W68BF 4MV1600N 18233 W68BD 4MV1600N 18249 4P W68BF 4HH1600H 18321 W68BD 4HH1600H 18337
2000 3P W68BF 3MV2000N 18234 W68BD 3MV2000N 18250 2000 3P W68BF 3HH2000H 18322 W68BD 3HH2000H 18338
4P W68BF 4MV2000N 18235 W68BD 4MV2000N 18251 4P W68BF 4HH2000H 18323 W68BD 4HH2000H 18339
2500 3P W68BF 3MV2500N 18236 W68BD 3MV2500N 18252 2500 3P W68BF 3HH2500H 18324 W68BD 3HH2500H 18340
4P W68BF 4MV2500N 18237 W68BD 4MV2500N 18253 4P W68BF 4HH2500H 18325 W68BD 4HH2500H 18341
H type Horizontal terminal connection Vertical terminal connection
85kA 1250 3P W68BF 3MH1250H 18254 W68BD 3MH1250H 18270 1250 3P W68BF 3HV1250H 18326 W68BD 3HV1250H 18342
4P W68BF 4MH1250H 18255 W68BD 4MH1250H 18271 4P W68BF 4HV1250H 18327 W68BD 4HV1250H 18343
1600 3P W68BF 3MH1600H 18256 W68BD 3MH1600H 18272 1600 3P W68BF 3HV1600H 18328 W68BD 3HV1600H 18344
4P W68BF 4MH1600H 18257 W68BD 4MH1600H 18273 4P W68BF 4HV1600H 18329 W68BD 4HV1600H 18345
2000 3P W68BF 3MH2000H 18258 W68BD 3MH2000H 18274 2000 3P W68BF 3HV2000H 18330 W68BD 3HV2000H 18346
4P W68BF 4MH2000H 18259 W68BD 4MH2000H 18275 4P W68BF 4HV2000H 18331 W68BD 4HV2000H 18347
2500 3P W68BF 3MH2500H 18260 W68BD 3MH2500H 18276 2500 3P W68BF 3HV2500H 18332 W68BD 3HV2500H 18348
Power Distribution Electrics

Power Distribution Electrics


4P W68BF 4MH2500H 18261 W68BD 4MH2500H 18277 4P W68BF 4HV2500H 18333 W68BD 4HV2500H 18349
Vertical terminal connection
1250 3P W68BF 3MV1250H 18262 W68BD 3MV1250H 18278 Frame C L type controller
4P W68BF 4MV1250H 18263 W68BD 4MV1250H 18279 3SW68-4000 N type Horizontal terminal connection
1600 3P W68BF 3MV1600H 18264 W68BD 3MV1600H 18280 85kA 2000 3P W68CF 3LH2000N 18350 W68CD 3LH2000N 18366
4P W68BF 4MV1600H 18265 W68BD 4MV1600H 18281 4P W68CF 4LH2000N 18351 W68CD 4LH2000N 18367
2000 3P W68BF 3MV2000H 18266 W68BD 3MV2000H 18282 2500 3P W68CF 3LH2500N 18352 W68CD 3LH2500N 18368
4P W68BF 4MV2000H 18267 W68BD 4MV2000H 18283 4P W68CF 4LH2500N 18353 W68CD 4LH2500N 18369
2500 3P W68BF 3MV2500H 18268 W68BD 3MV2500H 18284 3200 3P W68CF 3LH3200N 18354 W68CD 3LH3200N 18370
4P W68BF 4MV2500H 18269 W68BD 4MV2500H 18285 4P W68CF 4LH3200N 18355 W68CD 4LH3200N 18371
4000 3P W68CF 3LH4000N 18356 W68CD 3LH4000N 18372
H type controller 4P W68CF 4LH4000N 18357 W68CD 4LH4000N 18373
N type Horizontal terminal connection Vertical terminal connection
65kA 1250 3P W68BF 3HH1250N 18286 W68BD 3HH1250N 18302 2000 3P W68CF 3LV2000N 18358 W68CD 3LV2000N 18374
4P W68BF 4HH1250N 18287 W68BD 4HH1250N 18303 4P W68CF 4LV2000N 18359 W68CD 4LV2000N 18375
1600 3P W68BF 3HH1600N 18288 W68BD 3HH1600N 18304 2500 3P W68CF 3LV2500N 18360 W68CD 3LV2500N 18376
4P W68BF 4HH1600N 18289 W68BD 4HH1600N 18305 4P W68CF 4LV2500N 18361 W68CD 4LV2500N 18377
2000 3P W68BF 3HH2000N 18290 W68BD 3HH2000N 18306 3200 3P W68CF 3LV3200N 18362 W68CD 3LV3200N 18378
4P W68BF 4HH2000N 18291 W68BD 4HH2000N 18307 4P W68CF 4LV3200N 18363 W68CD 4LV3200N 18379
2500 3P W68BF 3HH2500N 18292 W68BD 3HH2500N 18308 4000 3P W68CF 3LV4000N 18364 W68CD 3LV4000N 18380
4P W68BF 4HH2500N 18293 W68BD 4HH2500N 18309 4P W68CF 4LV4000N 18365 W68CD 4LV4000N 18381
Vertical terminal connection H type Horizontal terminal connection
1250 3P W68BF 3HV1250N 18294 W68BD 3HV1250N 18310 100kA 2000 3P W68CF 3LH2000H 18382 W68CD 3LH2000H 18398
4P W68BF 4HV1250N 18295 W68BD 4HV1250N 18311 4P W68CF 4LH2000H 18383 W68CD 4LH2000H 18399
1600 3P W68BF 3HV1600N 18296 W68BD 3HV1600N 18312 2500 3P W68CF 3LH2500H 18384 W68CD 3LH2500H 18400
4P W68BF 4HV1600N 18297 W68BD 4HV1600N 18313 4P W68CF 4LH2500H 18385 W68CD 4LH2500H 18401
2000 3P W68BF 3HV2000N 18298 W68BD 3HV2000N 18314 3200 3P W68CF 3LH3200H 18386 W68CD 3LH3200H 18402
4P W68BF 4HV2000N 18299 W68BD 4HV2000N 18315 4P W68CF 4LH3200H 18387 W68CD 4LH3200H 18403
2500 3P W68BF 3HV2500N 18300 W68BD 3HV2500N 18316 4000 3P W68CF 3LH4000H 18388 W68CD 3LH4000H 18404
4P W68BF 4HV2500N 18301 W68BD 4HV2500N 18317 4P W68CF 4LH4000H 18389 W68CD 4LH4000H 18405
Vertical terminal connection
2000 3P W68CF 3LV2000H 18390 W68CD 3LV2000H 18406
4P W68CF 4LV2000H 18391 W68CD 4LV2000H 18407
2500 3P W68CF 3LV2500H 18392 W68CD 3LV2500H 18408
4P W68CF 4LV2500H 18393 W68CD 4LV2500H 18409
3200 3P W68CF 3LV3200H 18394 W68CD 3LV3200H 18410
4P W68CF 4LV3200H 18395 W68CD 4LV3200H 18411
4000 3P W68CF 3LV4000H 18396 W68CD 3LV4000H 18412
4P W68CF 4LV4000H 18397 W68CD 4LV4000H 18413

20 www.sassin.com www.sassin.com 21
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Frame C L type controller Frame C M type controller

3SW68-4000 S type Horizontal terminal connection 3SW68-4000 S type Horizontal terminal connection
120kA Rated current Number of Fixed type Drawer type 120kA Rated current Number of Fixed type Drawer type
In(A) poles Type code Order code Type code Order code In(A) poles Type code Order code Type code Order code
2000 3P W68CF 3LH2000S 18414 W68CD 3LH2000S 18430 2000 3P W68CF 3MH2000S 32077 W68CD 3MH2000S 32093
4P W68CF 4LH2000S 18415 W68CD 4LH2000S 18431 4P W68CF 4MH2000S 32078 W68CD 4MH2000S 32094
2500 3P W68CF 3LH2500S 18416 W68CD 3LH2500S 18432 2500 3P W68CF 3MH2500S 32079 W68CD 3MH2500S 32095
4P W68CF 4LH2500S 18417 W68CD 4LH2500S 18433 4P W68CF 4MH2500S 32080 W68CD 4MH2500S 32096
3200 3P W68CF 3LH3200S 18418 W68CD 3LH3200S 18434 3200 3P W68CF 3MH3200S 32081 W68CD 3MH3200S 32097
4P W68CF 4LH3200S 18419 W68CD 4LH3200S 18435 4P W68CF 4MH3200S 32082 W68CD 4MH3200S 32098
4000 3P W68CF 3LH4000S 18420 W68CD 3LH4000S 18436 4000 3P W68CF 3MH4000S 32083 W68CD 3MH4000S 32099
4P W68CF 4LH4000S 18421 W68CD 4LH4000S 18437 4P W68CF 4MH4000S 32084 W68CD 4MH4000S 32100
Vertical terminal connection Vertical terminal connection
2000 3P W68CF 3LV2000S 18422 W68CD 3LV2000S 18438 2000 3P W68CF 3MV2000S 32085 W68CD 3MV2000S 32101
4P W68CF 4LV2000S 18423 W68CD 4LV2000S 18439 4P W68CF 4MV2000S 32086 W68CD 4MV2000S 32102
2500 3P W68CF 3LV2500S 18424 W68CD 3LV2500S 18440 2500 3P W68CF 3MV2500S 32087 W68CD 3MV2500S 32103
4P W68CF 4LV2500S 18425 W68CD 4LV2500S 18441 4P W68CF 4MV2500S 32088 W68CD 4MV2500S 32104
3200 3P W68CF 3LV3200S 18426 W68CD 3LV3200S 18442 3200 3P W68CF 3MV3200S 32089 W68CD 3MV3200S 32105
4P W68CF 4LV3200S 18427 W68CD 4LV3200S 18443 4P W68CF 4MV3200S 32090 W68CD 4MV3200S 32106
4000 3P W68CF 3LV4000S 18428 W68CD 3LV4000S 18444 4000 3P W68CF 3MV4000S 32091 W68CD 3MV4000S 32107
Power Distribution Electrics

Power Distribution Electrics


4P W68CF 4LV4000S 18429 W68CD 4LV4000S 18445 4P W68CF 4MV4000S 32092 W68CD 4MV4000S 32108

M type controller H type controller


N type Horizontal terminal connection N type Horizontal terminal connection
85kA 2000 3P W68CF 3MH2000N 18446 W68CD 3MH2000N 18462 85kA 2000 3P W68CF 3HH2000N 32109 W68CD 3HH2000N 32125
4P W68CF 4MH2000N 18447 W68CD 4MH2000N 18463 4P W68CF 4HH2000N 32110 W68CD 4HH2000N 32126
2500 3P W68CF 3MH2500N 18448 W68CD 3MH2500N 18464 2500 3P W68CF 3HH2500N 32111 W68CD 3HH2500N 32127
4P W68CF 4MH2500N 18449 W68CD 4MH2500N 18465 4P W68CF 4HH2500N 32112 W68CD 4HH2500N 32128
3200 3P W68CF 3MH3200N 18450 W68CD 3MH3200N 18466 3200 3P W68CF 3HH3200N 32113 W68CD 3HH3200N 32129
4P W68CF 4MH3200N 18451 W68CD 4MH3200N 18467 4P W68CF 4HH3200N 32114 W68CD 4HH3200N 32130
4000 3P W68CF 3MH4000N 18452 W68CD 3MH4000N 18468 4000 3P W68CF 3HH4000N 32115 W68CD 3HH4000N 32131
4P W68CF 4MH4000N 18453 W68CD 4MH4000N 18469 4P W68CF 4HH4000N 32116 W68CD 4HH4000N 32132
Vertical terminal connection Vertical terminal connection
2000 3P W68CF 3MV2000N 18454 W68CD 3MV2000N 18470 2000 3P W68CF 3HV2000N 32117 W68CD 3HV2000N 32133
4P W68CF 4MV2000N 18455 W68CD 4MV2000N 18471 4P W68CF 4HV2000N 32118 W68CD 4HV2000N 32134
2500 3P W68CF 3MV2500N 18456 W68CD 3MV2500N 18472 2500 3P W68CF 3HV2500N 32119 W68CD 3HV2500N 32135
4P W68CF 4MV2500N 18457 W68CD 4MV2500N 18473 4P W68CF 4HV2500N 32120 W68CD 4HV2500N 32136
3200 3P W68CF 3MV3200N 18458 W68CD 3MV3200N 18474 3200 3P W68CF 3HV3200N 32121 W68CD 3HV3200N 32137
4P W68CF 4MV3200N 18459 W68CD 4MV3200N 18475 4P W68CF 4HV3200N 32122 W68CD 4HV3200N 32138
4000 3P W68CF 3MV4000N 18460 W68CD 3MV4000N 18476 4000 3P W68CF 3HV4000N 32123 W68CD 3HV4000N 32139
4P W68CF 4MV4000N 18461 W68CD 4MV4000N 18477 4P W68CF 4HV4000N 32124 W68CD 4HV4000N 32140
H type Horizontal terminal connection H type Horizontal terminal connection
100kA 2000 3P W68CD 3MH2000H 18478 W68CF 3MH2000H 18494 100kA 2000 3P W68CF 3HH2000H 32141 W68CD 3HH2000H 32157
4P W68CD 4MH2000H 18479 W68CF 4MH2000H 18495 4P W68CF 4HH2000H 32142 W68CD 4HH2000H 32158
2500 3P W68CD 3MH2500H 18480 W68CF 3MH2500H 18496 2500 3P W68CF 3HH2500H 32143 W68CD 3HH2500H 32159
4P W68CD 4MH2500H 18481 W68CF 4MH2500H 18497 4P W68CF 4HH2500H 32144 W68CD 4HH2500H 32160
3200 3P W68CD 3MH3200H 18482 W68CF 3MH3200H 18498 3200 3P W68CF 3HH3200H 32145 W68CD 3HH3200H 32161
4P W68CD 4MH3200H 18483 W68CF 4MH3200H 18499 4P W68CF 4HH3200H 32146 W68CD 4HH3200H 32162
4000 3P W68CD 3MH4000H 18484 W68CF 3MH4000H 18500 4000 3P W68CF 3HH4000H 32147 W68CD 3HH4000H 32163
4P W68CD 4MH4000H 18485 W68CF 4MH4000H 18501 4P W68CF 4HH4000H 32148 W68CD 4HH4000H 32164
Vertical terminal connection Vertical terminal connection
2000 3P W68CF 3MV2000H 18486 W68CD 3MV2000H 32069 2000 3P W68CF 3HV2000H 32149 W68CD 3HV2000H 32165
4P W68CF 4MV2000H 18487 W68CD 4MV2000H 32070 4P W68CF 4HV2000H 32150 W68CD 4HV2000H 32166
2500 3P W68CF 3MV2500H 18488 W68CD 3MV2500H 32071 2500 3P W68CF 3HV2500H 32151 W68CD 3HV2500H 32167
4P W68CF 4MV2500H 18489 W68CD 4MV2500H 32072 4P W68CF 4HV2500H 32152 W68CD 4HV2500H 32168
3200 3P W68CF 3MV3200H 18490 W68CD 3MV3200H 32073 3200 3P W68CF 3HV3200H 32153 W68CD 3HV3200H 32169
4P W68CF 4MV3200H 18491 W68CD 4MV3200H 32074 4P W68CF 4HV3200H 32154 W68CD 4HV3200H 32170
4000 3P W68CF 3MV4000H 18492 W68CD 3MV4000H 32075 4000 3P W68CF 3HV4000H 32155 W68CD 3HV4000H 32171
4P W68CF 4MV4000H 18493 W68CD 4MV4000H 32076 4P W68CF 4HV4000H 32156 W68CD 4HV4000H 32172

22 www.sassin.com www.sassin.com 23
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Frame C H type controller Frame D L type Controller


S type Horizontal terminal connection S type Vertical terminal connection
3SW68-4000 3SW68-6300
120kA Rated current Number of Fixed type Drawer type 150kA Rated current Number of Fixed type Drawer type
In(A) poles Type code Order code Type code Order code In(A) poles Type code Order code Type code Order code
2000 3P W68CF 3HH2000S 32173 W68CD 3HH2000S 32189 4000 3P W68DF 3LV4000S 32259 W68DD 3LV4000S 32271
4P W68CF 4HH2000S 32174 W68CD 4HH2000S 32190 4P W68DF 4LV4000S 32260 W68DD 4LV4000S 32272
2500 3P W68CF 3HH2500S 32175 W68CD 3HH2500S 32191 5000 3P W68DF 3LV5000S 32261 W68DD 3LV5000S 32273
4P W68CF 4HH2500S 32176 W68CD 4HH2500S 32192 4P W68DF 4LV5000S 32262 W68DD 4LV5000S 32274
3200 3P W68CF 3HH3200S 32177 W68CD 3HH3200S 32193 6300 3P W68DF 3LV6300S 32263 W68DD 3LV6300S 32275
4P W68CF 4HH3200S 32178 W68CD 4HH3200S 32194 4P W68DF 4LV6300S 32264 W68DD 4LV6300S 32276
4000 3P W68CF 3HH4000S 32179 W68CD 3HH4000S 32195
4P W68CF 4HH4000S 32180 W68CD 4HH4000S 32196 M type Controller
Vertical terminal connection N type Horizontal terminal connection
2000 3P W68CF 3HV2000S 32181 W68CD 3HV2000S 32197 100kA 4000 3P W68DF 3MH4000N 32277 W68DD 3MH4000N 32289
4P W68CF 4HV2000S 32182 W68CD 4HV2000S 32198 4P W68DF 4MH4000N 32278 W68DD 4MH4000N 32290
2500 3P W68CF 3HV2500S 32183 W68CD 3HV2500S 32199 5000 3P W68DF 3MH5000N 32279 W68DD 3MH5000N 32291
4P W68CF 4HV2500S 32184 W68CD 4HV2500S 32200 4P W68DF 4MH5000N 32280 W68DD 4MH5000N 32292
3200 3P W68CF 3HV3200S 32185 W68CD 3HV3200S 32201 6300 3P W68DF 3MH6300N 32281 W68DD 3MH6300N 32293
4P W68CF 4HV3200S 32186 W68CD 4HV3200S 32202 4P W68DF 4MH6300N 32282 W68DD 4MH6300N 32294
4000 3P W68CF 3HV4000S 32187 W68CD 3HV4000S 32203 Vertical terminal connection
Power Distribution Electrics

Power Distribution Electrics


4P W68CF 4HV4000S 32188 W68CD 4HV4000S 32204 4000 3P W68DF 3MV4000N 32283 W68DD 3MV4000N 32295
4P W68DF 4MV4000N 32284 W68DD 4MV4000N 32296
Frame D L type Controller 5000 3P W68DF 3MV5000N 32285 W68DD 3MV5000N 32297
N type Horizontal terminal connection 4P W68DF 4MV5000N 32286 W68DD 4MV5000N 32298
3SW68-6300
100kA 4000 3P W68DF 3LH4000N 32205 W68DD 3LH4000N 32217 6300 3P W68DF 3MV6300N 32287 W68DD 3MV6300N 32299
4P W68DF 4LH4000N 32206 W68DD 4LH4000N 32218 4P W68DF 4MV6300N 32288 W68DD 4MV6300N 32300
5000 3P W68DF 3LH5000N 32207 W68DD 3LH5000N 32219 H type Horizontal terminal connection
4P W68DF 4LH5000N 32208 W68DD 4LH5000N 32220 120kA 4000 3P W68DF 3MH4000H 32301 W68DD 3MH4000H 32313
6300 3P W68DF 3LH6300N 32209 W68DD 3LH6300N 32221 4P W68DF 4MH4000H 32302 W68DD 4MH4000H 32314
4P W68DF 4LH6300N 32210 W68DD 4LH6300N 32222 5000 3P W68DF 3MH5000H 32303 W68DD 3MH5000H 32315
Vertical terminal connection 4P W68DF 4MH5000H 32304 W68DD 4MH5000H 32316
4000 3P W68DF 3LV4000N 32211 W68DD 3LV4000N 32223 6300 3P W68DF 3MH6300H 32305 W68DD 3MH6300H 32317
4P W68DF 4LV4000N 32212 W68DD 4LV4000N 32224 4P W68DF 4MH6300H 32306 W68DD 4MH6300H 32318
5000 3P W68DF 3LV5000N 32213 W68DD 3LV5000N 32225 Vertical terminal connection
4P W68DF 4LV5000N 32214 W68DD 4LV5000N 32226 4000 3P W68DF 3LV4000H 32307 W68DD 3LV4000H 32319
6300 3P W68DF 3LV6300N 32215 W68DD 3LV6300N 32227 4P W68DF 4LV4000H 32308 W68DD 4LV4000H 32320
4P W68DF 4LV6300N 32216 W68DD 4LV6300N 32228 5000 3P W68DF 3LV5000H 32309 W68DD 3LV5000H 32321
H type Horizontal terminal connection 4P W68DF 4LV5000H 32310 W68DD 4LV5000H 32322
120kA 4000 3P W68DF 3LH4000H 32229 W68DD 3LH4000H 32241 6300 3P W68DF 3LV6300H 32311 W68DD 3LV6300H 32323
4P W68DF 4LH4000H 32230 W68DD 4LH4000H 32242 4P W68DF 4LV6300H 32312 W68DD 4LV6300H 32324
5000 3P W68DF 3LH5000H 32231 W68DD 3LH5000H 32243 S type Horizontal terminal connection
4P W68DF 4LH5000H 32232 W68DD 4LH5000H 32244 150kA 4000 3P W68DF 3MH4000S 32325 W68DD 3MH4000S 32337
6300 3P W68DF 3LH6300H 32233 W68DD 3LH6300H 32245 4P W68DF 4MH4000S 32326 W68DD 4MH4000S 32338
4P W68DF 4LH6300H 32234 W68DD 4LH6300H 32246 5000 3P W68DF 3MH5000S 32327 W68DD 3MH5000S 32339
Vertical terminal connection 4P W68DF 4MH5000S 32328 W68DD 4MH5000S 32340
4000 3P W68DF 3LV4000H 32235 W68DD 3LV4000H 32247 6300 3P W68DF 3MH6300S 32329 W68DD 3MH6300S 32341
4P W68DF 4LV4000H 32236 W68DD 4LV4000H 32248 4P W68DF 4MH6300S 32330 W68DD 4MH6300S 32342
5000 3P W68DF 3LV5000H 32237 W68DD 3LV5000H 32249 Vertical terminal connection
4P W68DF 4LV5000H 32238 W68DD 4LV5000H 32250 4000 3P W68DF 3MV4000S 32331 W68DD 3MV4000S 32343
6300 3P W68DF 3LV6300H 32239 W68DD 3LV6300H 32251 4P W68DF 4MV4000S 32332 W68DD 4MV4000S 32344
4P W68DF 4LV6300H 32240 W68DD 4LV6300H 32252 5000 3P W68DF 3MV5000S 32333 W68DD 3MV5000S 32345
S type Horizontal terminal connection 4P W68DF 4MV5000S 32334 W68DD 4MV5000S 32346
150kA 4000 3P W68DF 3LH4000S 32253 W68DD 3LH4000S 32265 6300 3P W68DF 3MV6300S 32335 W68DD 3MV6300S 32347
4P W68DF 4LH4000S 32254 W68DD 4LH4000S 32266 4P W68DF 4MV6300S 32336 W68DD 4MV6300S 32348
5000 3P W68DF 3LH5000S 32255 W68DD 3LH5000S 32267
4P W68DF 4LH5000S 32256 W68DD 4LH5000S 32268
6300 3P W68DF 3LH6300S 32257 W68DD 3LH6300S 32269
4P W68DF 4LH6300S 32258 W68DD 4LH6300S 32270

24 www.sassin.com www.sassin.com 25
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Frame D H type controller Intelligent controller model and panel description


3SW68-6300 N type Horizontal terminal connection
100kA Rated current Number of Fixed type Drawer type
Intelligent controller model type
In(A) poles Type code Order code Type code Order code
4000 3P W68DF 3HH4000N 32349 W68DD 3HH4000N 32361
4P W68DF 4HH4000N 32350 W68DD 4HH4000N 32362 3SW68-L Basic
5000 3P W68DF 3HH5000N 32351 W68DD 3HH5000N 32363 3SW68-M Standard
4P W68DF 4HH5000N 32352 W68DD 4HH5000N 32364 3SW68-H Communication
6300 3P W68DF 3HH6300N 32353 W68DD 3HH6300N 32365
4P W68DF 4HH6300N 32354 W68DD 4HH6300N 32366
Vertical terminal connection Introduction of intelligent controller panel
4000 3P W68DF 3HV4000N 32355 W68DD 3HV4000N 32367
4P W68DF 4HV4000N 32356 W68DD 4HV4000N 32368 L type Intelligent controller panel(3SW68-1600)
5000 3P W68DF 3HV5000N 32357 W68DD 3HV5000N 32369
4P W68DF 4HV5000N 32358 W68DD 4HV5000N 32370
6300 3P W68DF 3HV6300N 32359 W68DD 3HV6300N 32371
4P W68DF 4HV6300N 32360 W68DD 4HV6300N 32372 1 1. RESET Button
H type Horizontal terminal connection It pops up when fault tripping or test tripping. The circuit
120kA 4000 3P W68DF 3HH4000H 32373 W68DD 3HH4000H 32385
breaker can be switched on only when the button is
4P W68DF 4HH4000H 32374 W68DD 4HH4000H 32386
Power Distribution Electrics

pressed down. Meanwhile, the fault indicator resets.

Power Distribution Electrics


5000 3P W68DF 3HH5000H 32375 W68DD 3HH5000H 32387 2 3
4P W68DF 4HH5000H 32376 W68DD 4HH5000H 32388 2. Indication of rated current (In)
6300 3P W68DF 3HH6300H 32377 W68DD 3HH6300H 32389 5 4 3. MCU indicator
4P W68DF 4HH6300H 32378 W68DD 4HH6300H 32390
It remains lit when the controller is under normal working.
Vertical terminal connection 6
4. Over-voltage indicator
4000 3P W68DF 3HV4000H 32379 W68DD 3HV4000H 32391
4P W68DF 4HV4000H 32380 W68DD 4HV4000H 32392 It lights up when current reaches 1.15IR.
5000 3P W68DF 3HV5000H 32381 W68DD 3HV5000H 32393 5. Current bar indicator
4P W68DF 4HV5000H 32382 W68DD 4HV5000H 32394
To display the real time current as the percentage of IR; 10%
6300 3P W68DF 3HV6300H 32383 W68DD 3HV6300H 32395
each step.
4P W68DF 4HV6300H 32384 W68DD 4HV6300H 32396
S type Horizontal terminal connection 6. Fault reason indicator
150kA 4000 3P W68DF 3HH4000S 32397 W68DD 3HH4000S 32409 To show the fault reason after tripping occurs.
4P W68DF 4HH4000S 32398 W68DD 4HH4000S 32410 If power supply works normally, it will indicate the fault
5000 3P W68DF 3HH5000S 32399 W68DD 3HH5000S 32411
reason after fault tripping. Press RESET to quit.
4P W68DF 4HH5000S 32400 W68DD 4HH5000S 32412
6300 3P
If power supply is lost, press FAULT CHECK key to show the
W68DF 3HH6300S 32401 W68DD 3HH6300S 32413
4P W68DF 4HH6300S 32402 W68DD 4HH6300S 32414 reason of last tripping when power recovers.
Vertical terminal connection 7. Current settings adjustor
4000 3P W68DF 3HV4000S 32403 W68DD 3HV4000S 32415
8. Time settings adjustor
4P W68DF 4HV4000S 32404 W68DD 4HV4000S 32416
9. FAULT CHECK key
5000 3P W68DF 3HV5000S 32405 W68DD 3HV5000S 32417
4P W68DF 4HV5000S 32406 W68DD 4HV5000S 32418 Press the key to enter fault check status when the controller
6300 3P W68DF 3HV6300S 32407 W68DD 3HV6300S 32419 8 is under normal working.
4P W68DF 4HV6300S 32408 W68DD 4HV6300S 32420
7 9
10. TEST key

10 Press TEST key, the breaker trips immediately, but no fault


recorded. Press RESET and CLEAR after test.
11 11. CLEAR key

Note: Parameter setting IR <Isd <II

26 www.sassin.com www.sassin.com 27
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

M type and H type Intelligent controller panel for (3SW68-1600) L type Intelligent controller panel
(3SW68-2500、4000、6300)
Indication 1. Mechanical RESET button
1 1. RESET button It pops up after tripping. Manual reset is required.
1
3SW68 It pops up when fault tripping or test tripping. The circuit 2. Indication of intelligent controller model
Intelligent controller breaker can be switched on only when the button is pressed 3. Operation indicator
down. Meanwhile, the fault indicator resets. It remains flashing when the controller is under normal
2. LCD display 3SW68 - L 2 working.
3. Fault and alarm RESET key 4. IR%
4. FAULT/ALARM LED indicator Electronic Controller 40%~100% indicator: To display the real time current as
The indicator is out when normal working; it flashes quickly the percentage of IR.
2 when maintenance; it turns on in red when alarm. 3 Operation 5. Indication of rated current (In)
5. NORMAL LED indicator 6. Simulation test area
运行 通信 遥控 故障
It flashes in green always when the controller is power on 6.1.Query key: check the last fault record (Record is shown
and under normal working. I R% Load current as: one of the four fault indicators, IR, Isd, Ii, and Ig,
6. LED curve 4 becomes lighting. Press Clear button to clear indication).
Red LED indicators are equipped in the curve. 40 60 80 100 6.2.Test key: When press Test Key under normal working
Power Distribution Electrics

Power Distribution Electrics


Reset 3
IR

Fault/Alarm
The corresponding indicator flashes to indicate the fault status of controller, the breaker, commanded by the
4
Normal
reason when fault tripping. controller, trips instantaneously. Meanwhile, Ii fault
5
Is The corresponding indicator remains lit to indicate the indicator lights up, but no fault recorded.
current setting when protection settings. 6.3.Check key: self-diagnosis of inner working, each
7. Test port light will automatically scan, and will show a menu in
Ig Isd A 16-pin test port is available on the bottom of front panel one minute.
Ii for plug-in portable power supply or inspection unit.
5 In= 4000 A 6.4.Clear button: clear the fault indicator
6 7. Protect characteristic parameter setting area
Keyboard 7.1. IR (time-lapse protection) original setting is
8. Function key 1 – Measurement: For measuring 6 IR = 1.0 I n, t R = 480s.
Quary Test Check Clear
(In password input interface, the LEFT key) 7.2. I sd (short delay protection) original setting is
Press to enter the measurement default menu to measure I sd = 8 IR t sd = 0.4s (NO, OFF means inverse switch
current “I”, voltage “U’, frequency “F”, power “P”, energy “E”, IR 0.7
0.6
0.8 0.85
0.9
90 120 180
tR S status default setting is OFF).
60 240
0.5 0.95 45 360
and harmonic “H”. 0.4 1.0 30 480
7.3. I i (instantaneous protection) original setting Ii =10In.
In OFF 15 @1.5 IR

7 9. Function key 2 – Settings: For system parameter settings 7.4. I g (ground fault protection) original setting
(In password input interface, the RIGHT key) 4 6 8 0.4 0.4 I g = 0.8 I ntg = 0.4s.
Isd tsd s
3 10 0.3 0.3
Press to enter the setting default menu to set “Clock settings”, 2 12 0.2 0.2 8. Fault indicator: Lighting when fault occurs.
1.5 15 0.1 0.1
IR @8 IR
“Meter settings”, “Test & Lock”, “Communication settings”, OFF ON I2 t OFF
8
7
“I/O settings”.
4 6 8
Ii
3 10
10. Function key 3 – Protections: For protection parameter 2 12
1 15
settings Press to set the parameters of “Current protection”, In OFF

8 9 10 11 “Load monitor”, “Voltage protection”, and “Other protections”.


Ig 0.5 0.6 0.65 0.5 0.6 0.7 tg s
11. Function key 4 – Information: For history record and 0.4 0.7 0.4 0.8
0.3 0.75 0.3 0.9
maintenance Press to check “Current alarm”, In
0.2
OFF
0.8 0.2
1.0
1.0

“Operation times”, “Contact wear”, “Product information”,


“Tripping record”, “Alarm record”, “Transposition record”.
ESC 12. UP – To move up or change the parameters upwards
13. DOWN – To move down or change the parameters
downwards.
12 13 14 15 14. Esc – To exit and return to previous menu or cancel the
current setting selection.
15. ENTER – To enter the next menu, select the current
parameter, or save the updates.

28 www.sassin.com www.sassin.com 29
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

M type Intelligent controller panel H type Intelligent controller panel


(3SW68-2500、4000、6300) (3SW68-2500、4000、6300)

1. Mechanical RESET button 1 . Mechanical RESET button


1 It pops up after tripping. Manual reset is required. 1 It pops up after tripping. Manual reset is required.
2. Indication of intelligent controller model 2. Indication of intelligent controller model
3. Power indicator: 3. LCD display
It keeps flashing when power on. 4. Indication of rated current (In)
3SW68-M 2 4. LCD display 3SW68 - H 2
5. Software RESET button
5. Indication of rated current (In) 6. Status indicator area
Electronic Controller 6. Simulation test area Electronic Controller
7. Characteristic curve and protection reason indicator
8. Function key area
3 Operation 6.1. ENTER key: To enter or confirm menu.

6.2. ESC ESC key: To return to previous menu or exit menu

4 6.3. UP DOWN key: To scroll up or down the menu 3


Power Distribution Electrics

Power Distribution Electrics


7. Protection characteristic parameter setting area
7.1. IR ( long-time delay protection) default setting IR=1.0In,
t R = 480s
7.2. I sd (short delay protection) default setting Isd=8IR ,
tsd = 0.4s (NO, OFF means inverse switch, original
setting is OFF)
5 In= 4000 A 7.3. I i (instantaneous protection) default setting
I i = 10 I n
7.4. I g (ground fault protection) default setting
4 In= 4000 A
I g = 0.8 I n, tg = 0.4s
IR RESET 5
6
ESC 8. Fault indicator: Warn/Alarm

Lighting when fault occurs. 6


Healthy
0.7 0.8 0.85 90 120 180 Is
I RR tRR S
0.6 0.9 60 240 7
0.5 0.95 45 360 BUS
0.4 1.0 30 480
In OFF 15 @1.5 IR

4 6 8 0.4 0.4
Isd
Isd tsd S
3 10 0.3 0.3 Ig I sd
2 12 0.2 0.2
1.5 15 0.1 0.1
IR @8 IR
OFF ON I2 t OFF
8 Ii
7
4 6 8
Ii
3 10
2 12
1 15
In OFF
8

Ig 0.5 0.6 0.65 0.5 0.6 0.7 tg(S)


tg
0.4 0.7 0.4 0.8
0.3 0.75 0.3 0.9

In
0.2
OFF
0.8 0.2
1.0
1.0 ESC

30 www.sassin.com www.sassin.com 31
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Intelligent controller protection characteristics 3SW68-H

3SW68-L and 3SW68-M Overload long-time delay settings ON/OFF selectable


Setting current adjustment range IR(A) (0.4~1.0)xIn (Inm≤2500A step length 1A ;Inm>2500A,step length 2A)
Inverse time characteristics Set by the user as needed, tR(s)when 1.5IR as a benchmark,10% accuracy)
Overload long-time delay settings (accuracy ±10% based on tR(s) at 1.5IR) 1.05IR 2h no action
1.30R(Generator protection 1.25IR) ≤2h action
Setting current adjustment range IR(A) OFF (Set by user)
tR(S) at 1.5IR 15 30 60 120 240 480
0.4xIn 0.45 xIn 0.5 xIn 0.55 xIn 0.6 xIn 0.7 xIn 0.8 xIn 0.9 xIn 1.0 xIn tR(S) at 2IR 8.4 16.9 33.8 67.5 135 270
Inverse time characteristics tR(S) at 6.0IR 0.94 1.88 3.75 7.50 15 30
tR(S) at 7.2IR 0.65 1.3 2.6 5.2 10.4 20.8
1.05IR 2h no action Thermal memory time setting Instantaneous 10 20 30 45 60 120 180
1.3 IR( 1.25 IR for generator protection)) ≤2h action
Short-circuit short-time delay settings ON/OFF selectable
tR(S) at 1.5IR 15 30 60 120 240 480 Note: 30,60,120,240 for 3SW68-L(1600) Setting current adjustment range Isd (A) ±10% accuracy (1.5~15)xIR (Inm≤2500A step length 1A ;Inm>2500A,step length 2A)
tR(S) at 2IR 8.4 16.9 33.7 67.5 135 270 Delay time 1/10tR (tR(s)when 1.5IR as a benchmark)

tR(S) at 7.2IR 0.65 1.3 2.6 5.2 10.4 20.8


Short circuit short definite time Isd(A) ON/OFF selectable
Thermal memory time setting(min) 60 Note: 30 min for 3SW68-L(1600) Setting current adjustment range Isd ±10% accuracy (1.5~15)xIR (Inm≤2500A step length 1A ;Inm>2500A,step length 2A)
Setting delay time tsd(s)±15% accuracy 0.1 0.2 0.3 0.4
Returnable time (s) 0.06 0.14 0.23 0.35
Short-circuit short-time delay settings (accuracy ±10% based on tR(s) at 1.5IR when I<8IR)
Power Distribution Electrics

Power Distribution Electrics


Setting current adjustment range Isd(A) OFF 1.5xIR 2xIR 2.5xIR 3xIR 4xIR 5xIR 6xIR 8xIR 10xIR 12xIR 20xIR Note:(3~10)IR for 3SW68-L(1600) Instantaneous short-circuit I ON/OFF selectable
Setting current adjustment range Ig(A)±10% accuracy (1.0~20)xIR (Inm≤2500A step length 1A ;Inm>2500A,step length 2A)
When 1>8IR

Definite characteristic (set by user) tsd(s) 0.1 0.2 0.3 0.4 Ground protection type T W ON/OFF selectable
Setting current adjustment range Ig(A)±10% accuracy (0.2~1.0)xIR (Inm≤2500A step length 1A ;Inm>2500A,step length 2A)
(according to requirements set by the user) tsd(s)
Setting delay time tg(s) ±15% accuracy 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Returnable time (s) 0.06 0.14 0.23 0.35 Returnable time (s) 0.06 0.14 0.23 0.35 resetting ratio is 0.85

When 1>8IR
alarm/trip/off selectabe
Inverse characteristic (set by user) I²tsd(s) As per characteristic s curve Current imbalance (When the three-phase current imbalance is greater than 1.1 times the set value,
(according to requirements set by the user) I²tsd(s) the protection action will be done; the return character
alarm/trip/off selectabe
Required current protection (When the three-phase current imbalance is greater than 1.1 times the set value,
Instantaneous short-circuit setting (accuracy of ±10%) the protection action will be done; the return character
Setting range of value of start protection required(0.2~1)xIn
Setting current adjustment range Ii(A) OFF 1.5xIR 2xIR 2.5xIR 3xIR 4xIR 5xIR 6xIR 8xIR 10xIR 12xIR 20xIR
Setting range of protection action time required 15~1500s
Note: (3,4,6,8,10,12,15)In for 3SW68-L(1600)
Alarm/trip selectable
Under voltage protection (When the three-phase current imbalance is greater than 1.1 times the set value,
Earth fault settings (accuracy±10%) the protection action will be done; the return character will be lower than 0.9 setting value.
Setting current adjustment range Ig(A) OFF 0.2xIn 0.3xIn 0.4xIn 0.5xIn 0.6xIn 0.7xIn 0.8xIn 0.9xIn 1.0xIn Over voltage protection
Alarm/trip selectable
(Note: (0.2~0.8)In for 3SW68-L(1600) (When the current imbalance is greater than 1.1 times the set value,
the protection action will be done; the return character will be lower than 0.9 setting value.
Definite time characteristics ( set by user) tg(s) 0.1 0.2 0.3 0.4
Load monitoring (power based) Made 1/mode 2/OFF selectable
Returnable time (s) 0.06 0.14 0.23 0.35
Measurement
Inverse time characteristics (set by user) I²tsd(s) As per characteristic s curve Frequency 40~65Hz
Power Active power: -32768kW~32768kW
Reactive power: -32768kar~32768kar
Overload alarm setting (accuracy ±10%) Apparent power: 0kVA~65535kVA
Overload alarm current when Im>IR Electric energy Active energy: 0~4294967295kWh
Reactive energy: 0~4294967295kWh
Delay time tm (s)
Apparent energy: 0~4294967295kWh
0.5tR
Inverse time characteristics Current Demand Current real-time measurements
Power Demand Power real-time measurements
Harmonic Currrent:3~31harmonic
Voltage:3~31harmonic
Self-test function The EEPROM fault, setting parameters lost, AD sampling error, RAM or ROM error, error
messages and alarm signals
DI/DO Function Provide digital input and output (AC250V 5A resistive or DC110V 0.5A resistive)
Zone selective interlocking feature Short circuit interlock and ground interlock
Test function Test release: Long-time delay, short-time delay ,instantaneous ,ground

32 www.sassin.com www.sassin.com 33
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Current protection characteristics for intelligent controller Protection characteristics of intelligent controller 3SW68-H

Functions Earth fault protection characteristic curve

◆ available ◇ selectable 10000


t (s)
5000

L M H 2000
Ir4=0.2ln-1.01ln
1000
Long-time delay protection
500
Short circuit short-time
delay protection
200
Grounding protection 100

Short circuit 50
instantaneous protection
20
Imbalance or open-phase
protection 10

5
Load monitor
Ampere meter 2

Voltage meter 1

Pre-alarm 0.5 0.4s


Power Distribution Electrics

Power Distribution Electrics


0.3s
Fault alarm 0.2 0.2s
Self-diagnostic 0.1 0.1s
MRC function 0.05
RS485 port
0.02
Communication protocols
module 00801 02 03 05 081 152 3 5 8 10
x ln

Characteristics curve Ig earth fault protection current setting value tg earth fault protection time setting value

t l 2tswitch off t

setting
l 2tinput
(lc1)
Characteristics curve of overload protection

setting(lc1) Earth fault current setting Ig 10000


t (s)
5000
Earth fault delay time setting tg Ir1=0.4-1 X In
2000

1000

500 tL=15S Ir1: Overload long-delay setting


tL=30S
200 Ir2: Short-circuit short-delay current
0 I I tL=60S
100 setting
tL=120S
Monitor and controlling setting(R) Earth fault protection features Ir3: Overload long-delay time setting
50 tL=240S
tL=480S Tl: Instantaneous short-circuit current
20
Isd
setting
10
Ts: Short-circuit short-delay time
5 setting
Ir2=1-15 x In
t Overload long-time delay current setting IR
2
Overload long-time delay time setting tR
1

0.5 t s=0.4S
Short-circuit short-time delay current setting Isd
Short-circuit short-time delay inverse time (I²t ON) 0.2 ts=0.3S
Short-circuit short-time delay time setting tsd Ir3
ts=0.2S
0.1
Short-circuit instantaneous setting Ii Ir3

Short-circuit short-time delay definite time (I²t OFF) 0.05

I ts=0.1S
0.02

0.8 1 1.5 2 3 5 8 10 15 20
Long delay, short delay, instantaneous protection features 30 60 90 100 120 150 200
× IR kA

34 www.sassin.com www.sassin.com 35
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Kinds of characteristic overview ( rate curve: C8) Standard inverse time lag C8 Connection diagram for the secondary circuit of the L-type intelligent controller

Main Closing Shunt Contract Under-voltage


circuit Electronic controller electromagnet release eletromanet release Auxiliary contact for user Drawer three-position indication

PE N Fault indicator Storage indicator Closing indictor Tripping indicator


1000
S1 SB1 SB2 SB3 S2 S3 S4 S5 S6 S7
E E E

1000
FU
100 P 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 45 47 48 50 51 53 54 56 57 59 60 62 63 65 66
XT

100
trip time (secs)

DT F Q/QY M Control power supply


10

trip time (secs)


DW SAL

Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 Q12 Q13Q14


TA
Breaker
10 body
Electronic controller
SA
1 FU

1 2 3 4 7 9 11 13 15 17 19 21 23 25 29
27 31 33 35 37 39 41 43 46 49 52 55 58 61 64
1
0.1
DC24V
12 13 14 15 16 17 18 19

0.1 - +
Power Distribution Electrics

Power Distribution Electrics


FU

0.01 1 10 L N PE ST Power modules TV

1 10 AC220V/DC110-220V

* Ir (setting value of long time delay)

* Ir (setting value of long time delay) Abbreviation Meaning Abbreviation Meaning Abbreviation Meaning
standard inverse time lag C8 fast inverse time lag C8
express inverse time lag C8 express inverse time lag(M) C8 SB1 Closing button (self-provided TA Current mutual transformer M Motor operating mechanism
high voltage fuse compatibility C8 I 2t C1 by user)
SB2 Shunt button (self-provided byuser) FU Fuse (self-provided by user) SA Limit switch of motor
SB3 Under-voltage button(self-provided by user) F Shunt release SAL Contact for malfunction tripping indicator
Fast inverse time lag C8 Express inverse time lag C8 S1~S7 Indicator (self-provided by user) Q Under-voltage release Q1~Q8 Auxiliary contacts 4NO+4NC
DW Circuit breaker QY Under-voltage delay release Q9~Q14 Contacts for drawer 3-position indicator
with time delay
XT Secondary wiring circuit DT Closed coil

The meaning of terminals


#1, #2: Input terminal of auxiliary power supply; #1 is the positive pole.
10000 10000 P: Protective ground terminal to connect the side plate of the breaker.
#3, #4, #5: SDE malfunction tripping output contacts (#4 is the common terminal); contact capacity: AC380V 16A
1000 #13, #14, #19, #20, #21: #19 is the output common terminal; #20 is output contact No.1 (D01) for self-diagnosis function; #21 is output
1000
contact No.2 (D02) for malfunction tripping function; #13 is output contact No.3 (D03) for overload warning function; #14 is output
trip time (secs)

contact No.4 (D04) for grounding alarm function.


trip time (secs)

100 100
#25, #26: To connect external current transformer (For 3P+N only)
Note:
10 1)It is necessary to select power supply unit when DC control power is applied. Connect the DC control power to power supply unit,
10
where the output contacts have already been connected before delivery.
2)Normally it is not necessary to select power supply unit when AC control power is applied; just simply connect the power supply to
1
1 the terminal #1 and #2. In case you require power supply unit, please make the connection according to the wiring diagram. The
output contacts of the unit have already been connected before delivery.
0.1
3)Drawer 3-position indicator is an optional device for users.
0.1 4)The connections marked in the dotted lines are to be made by the users.
1 10 1 10
5)The conditions that the controller outputs self-diagnosis signal:
a.Controller internal temperature ≥80℃
b.Chip works abnormally
* Ir (setting value of long time delay) * Ir (setting value of long time delay)
c.Controller loses power
6)Different power supplies can be connected when the control voltages of DT, F and Q/QY are not same.
7)A pushbutton with normal open contact can be installed in series between the terminal #42 and power supply for manually
controlling pre-storage.
8)SB2 can be connected in parallel to relay contacts for remote tripping.
9)Additional accessories need to be self-provided by users.

36 www.sassin.com www.sassin.com 37
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Connection port of 3SW68-1600(type M、H) Abbreviation Meaning Abbreviation Meaning Abbreviation Meaning
SB1 Closing button (self-provided by user) TA Current mutual transformer M Motor operating mechanism
SB2 Shunt button (self-provided by user) FU Fuse (self-provided by user) SA Limit switch of Motor
A,B,C
SB3 Under-voltage button(self-provided by user) F Shunt release SAL Contact for malfunction tripping indicator
N S1~S7 Indicator (self-provided by user) Q Under-voltage release Qa , Qb Contacts for closing indicator
DW Circuit breaker QY Under-voltage delay release with time delay Qc , Qd Contacts for tripping indicator
XT Secondary wiring circuit DT Closed coil Q1~Q8 Auxiliary contacts 4NO+4NC
TN Residual current transformer (can be supplied upon user’s request) Q9~Q14 Contacts for drawer 3-position indicator
P 1 2 5 6 7 8 9 10 12 11 14 13 15 16 29 30
A (+) B (-) Communication A (+) B (-) Add N-phase
The meaning of terminals #21, #22: Programmable switching input No.1 (DI1)
Power input ground wire Communication input in 3P + N
DC24V port Power supply input #23, #24: Programmable switching input No.2 (DI2)
DW
#1, #2: DC24V #1: positive pole #2: negative pole; P: Voltage signal input
Protective ground terminal to connect the side plate of Terminals #25~#28 are the input terminal of voltage signal.
Auxiliary contacts synchronous with the circuit breaker
3SW68-1600 Intelligent controller the breaker. Please pay attention that the connection sequence must be
Linear signal coil
L1~L4 External current transformer input right and they must be connected to the line side of the
D03 OR DI2 D04 OR DI1 Terminals #3, #4 are for external current transformer input. power supply.
Power mutual inductor Add mutual Voltage measurement The terminals are to be connected to the output terminals
P1~P3 D01 D02 The terminals are blank if no additional functions are selected.
inductor input signal input
of external current transformer ZT100 when the grounding Terminals #29~#30 are to be connected to signal input of
in ground or leakage Un U1 U2 U3
Power Distribution Electrics

Power Distribution Electrics


3 4 17 18 19 20 21 22 23 24 25 26 27 28 method is type T. neutral line with an external current transformer when
The terminals are to be connected to the output terminals grounding method is 3P+N.
Programmable input /
To the power line side of external rectangular current transformer ZCT1 when Note:
ZT100 Output contacts
Center ground lug the grounding method is type W.
ZCT 1) It is necessary to select power supply unit when DC control
Auxiliary contacts for malfunction tripping power is applied. Connect the DC control power to power
Terminals #5, #6, #7 are the contacts for malfunction supply unit, where the output contacts have already been
tripping indicator. connected before delivery.
Contact capacity: AC380V 2A; DC250V 0.3A 2) Normally it is not necessary to select power supply unit
Figure: input and output interfaces of 3SW68-1600 type M, H
Auxiliary contacts synchronous with circuit breaker when AC control power is applied; just simply connect the
Terminals #8, #9, #10, #11, #12, #14 are two sets of power supply to the terminal #1 and #2. In case you require
auxiliary contacts synchronous with circuit breaker. power supply unit, please make the connection according
Connection diagram for secondary circuit of the M , H-type intelligent controller Contact capacity: AC380V 1A; DC250V 0.15A to the wiring diagram. The output contacts of the unit have
Communication output already been connected before delivery.
Main Closing Shunt Contract Under-voltage #15, #16: Communication interface output. The output 3) Drawer 3-position indicator is an optional device for users.
circuit Electronic controller electromagnet release electromagnet release Auxiliary contact for user Drawer 3-position indicator
PE N Note: Short 3 and 4 Fault indicator Storage instruction Closing instruction Tripping indication
methods of three communication protocols are the same. 4) The connections marked in the dotted lines are to be made
when no external current
transformer needs to be #15 and #16 are blank when with communication function. by the users.
connected S1 S2 S3 SB1 SB2 SB3 S4 S5 S6 S7
E E E #13: Communication shielding ground 5) The conditions that the controller outputs self-diagnosis
Programmable I/O interface signal:
32 34 36 38 40 42 44 45 47 48 50 51 53 54 FU
3 4 P 6 8 10 12 14 16 18 20 22 24 26 28 30 56 57 59 60 62 63 65 66
XT
Terminals #17~#24 are blank when signal unit is not a. Controller internal temperature ≥80℃
selected. (DO: DC11V 0.5A, AC250V 5A; DI: DC11V~13V b. Chip works abnormally
Q/QY
AC110V~250V) c. Controller loses power
DW DT F M
SAL Control power supply
When the signal unit is type S1: (4DO mode) 6) Different power supplies can be connected when the
Qa Qb Qc Qd Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 Q12 Q13Q14
TA
Breaker Electronic controller #17, #18: Programmable output contact No.1 (DO1) control voltages of DT, F and Q/QY are not same.
body SA
#19, #20: Programmable output contact No.2 (DO2) 7) A pushbutton with normal open contact can be installed
FU
#21, #22: Programmable output contact No.3 (DO3) in series between the terminal #42 and power supply for
1 2 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 46 49 52 55 58 61 64
#23, #24: Programmable output contact No.4 (DO4) manually controlling pre-storage.
When the signal unit is type S2: (3DO+1DI mode) 8) SB2 can be connected in parallel to relay contacts for
DC24V
12 13 14 15 16 17 18 19 #17, #18: Programmable output contact No.1 (DO1) remote tripping.
- +
FU #19, #20: Programmable output contact No.2 (DO2) 9) Additional accessories need to be self-provided by users.
L N PE ST Power modules TV
#21, #22: Programmable output contact No.3 (DO3)
AC220V/DC110-220V #23, #24: Programmable switching input No.1 (DI1)
When the signal unit is type S3: (3DO+1DI mode)
#17, #18: Programmable output contact No.1 (DO1)
#19, #20: Programmable output contact No.2 (DO2)

38 www.sassin.com www.sassin.com 39
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Secondary circuit wiring diagram equipped with Intelligent controller (3SW68-2500、4000、6300) Explanation of symbol

Auxiliary open mode


Abbreviation Meaning Abbreviation Meaning
Four groups convertible contact

SB1 Under-voltage button (Self-provided by user) Q Under-voltage (or time delayed) release
SB2 Closing button (Self-provided by user) X Closing electromagnet

Main circuit
SB3 Shunt button (Self-provided by user) M Electric motor operating mechanism
SB4 Remote reset button (Self-provided by user) SA Electric motor limit switch
F Shunt release XT Terminal block

Connection
J1 Remote control closed relay (Self-provided by user) Fu Fuse
J2 Remote control trip relay (Self-provided by user)

Test

indication
Position
pieces of normally-closed contacts
Four pieces of normally-open and four

Explanation of terminal block: A1~A6: Three position signal output(optional)

Separation
1#、2#: Auxiliary power input 1# is“+” 2# is“-”if it is direct B1~B6: Empty terminal(Spare)

Fault tripping
current T1~T4: Three position signal input(optional)
3#、4#、5#、6#: A、B、C、N three-phase voltage input S、A、B:Communication output(optional)

Switch on
terminal are used for voltage indication (optional)
7#、8#、9#:Fault trip indication signal output Illustration

Control unit
Power Distribution Electrics

Power Distribution Electrics


10#、11#、12#:Switch on indication signal output 1.The corresponding circuit breakers in the diagram are

Switch off
Six-group convertible contact

13#、14#、15#:Switch off indication signal output switched off and no energy stored. The controller indicates
16#、17#:Programmable output 1(optional) no fault
18#、19#:Programmable output 2(optional) 2.The dotted line part shall be connected by user, the picture

controller
Intelligent
communication
Draw-out base
module

20#、21#:ZS1 signal output,20# connects“+”,21# is for reference only.


connects“-”(optional) 3. 1#, 2# terminal power source must be prepared when the
module
output

22#、23#:ZS1signal output,22# connects“-”,23#


Power

main loop current is 0.4 In. The DC24V、AC230VAC or 400V

voltage switch on switch off


connects“+”(optional) power can be connected depending on controller power type.

Under Electric
pieces of normally-closed contacts
Six pieces of normally-open and six

24#、25#、26#:Intelligent controller communication The power then connects with DC 110VD and C220V after
terminal,24# connects with SH Shielding layer, 25# converted by power module.
connects A,26# connects B, but connects with the draw- 4. Q, X, F, M connects different control power sources depending

Electric
out-base communication module input if there is a draw- on respective voltage specifications. Please note X, F are short-
picture 1

out-base communication module,24# connects S',25# time duty components, the electrified time should not exceed

storage
Electric
energy
Ready-for-
for-close

charging
Ready-

connects A',26# connects B'(optional) 4 seconds.


for-close
Ready- Remote 27#、28#:Added earth current or current leakage type 5.37# terminal directly connects power source (see the picture)
Permutation and combination of internal terminal

Permutation and combination of external terminal

transformer input(optional) (automatic pre-energy storage). It can also connect power


29#、30#:External neutral current transformer input source after serially connecting the normally open button
reset
Six line program-
mable extended
output module

(optional) (Manual pre-energy storage).


Circuit breaker

31#、32#、33#:Under voltage(or time delayed)release 6.The three position signal sampling from the draw-out base
power input, 33# is empty terminal(optional) communication module should be processed by optical
34#、35#、36#:Closing electromagnet power input,36# coupling isolation.
is empty terminal 7. The outdoor terminal which fixed on the drawing frame
37#、38#、39#:Shunt release power input,39# is empty of breaker, wiring connection is according to picture 2; the
Auxiliary switch

Auxiliary switch

terminal terminal which fixed in internal breaker, wiring connection


40#、41#、42#:Energy storage electrically operated power is according to picture 3.
input and energy storage ready signal output.
43#、44#、45#:Open ready signal output(optional)
46#、47#、48#: Remote reset power input, 48# is empty
terminal (optional)
49#、50#、51#:Programmable extended output,49#
connects A,50# connects B, 51# is empty terminal(optional)
picture 2
picture 3

52#、53#、54#:Empty terminal(Spare)
source

55#~58#:Auxiliary switch for connecting terminal output


Power

40 www.sassin.com www.sassin.com 41
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Accessories Regular malfunction and solutions

Electric operation mechanism Fault description Reasons analysis Maintenance method


It is used for breaker motor for energy storage and automatic energy-restoring Tripping of Over load tripping 1.Check the breaking current value and operation time of intelligent release.
Normal standard configuring accessories are as below circuit breaker (IL indicator flashing) 2.Analyze the load and electric network,exclude the overload if it happens.
3.Match the actual operating current with long time-delay current setting value.
Rated control power voltage Us(v) AC400, AC230, DC220, DC110 4.press the reset button to reclose the breaker.
Tripping voltage(V) (0.85~1.1)Us Short circuit tripping 1.Check the breaking current value and operation time of intelligent release.
Power consumption 80VA, 80W ("is"or "li"indicator flashing) 2.Exclude the short circuit fault if it happens.
Storage time (s) <5 3.Check the setting value of intelligent release.
4.Check the normal state of breaker.
5.Press the reset button to reclose the breaker.
Closing electromagnet Earthing fault tripping 1.Check the breaking current value and acting time of intelligent release.

After charging is finished, the closing electromagnet can break the circuit (IG indicator flashing) 2.Exclude the earthing fault if that happens
3.Match the fault current setting value with the actual protection.
breaker by remote control
4.Press the reset button to reclose the breaker.
Normal configuring accessories
Under-voltage release fault: 1.Check the power is on or not.
1.Rated working voltage is less than 70%Ue 2.Check the power voltage of under-voltage release, it shouldn't be less than 85%Ue
Rated control power source voltage Us(v) AC400, AC230, DC220, DC110
2.Fault of control unit 3.Replace the control unit of under-voltage release.
Tripping voltage(V) (0.85~1.1)Us
Mechanical interlock acting Check the working state of two circuit breakers fixed with mechanical interlock.
Closing time (ms) <70
Power Distribution Electrics

Power Distribution Electrics


The breaker Intelligent release don't reset (panel is raised) Press the reset button to redose the breaker
can't be closed secondary circuit of drawer out Make the breaker to "making"position
-type breaker isn't connected ("click"sound will be heard)
Shunt release
Breaker hasn't stored energy Check the secondary circuit:
To break the circuit breaker by remote control
1.power boltage of motor shouldn't less than 85%Ue.
Normally deployed accessories 2.Check the storage mechanism, replace it if mecessary.
The breaker Mechanical interlock acting Check the working state of two circuit breakers
Rated control power source voltage Us(v) AC400, AC230, DC220, DC110
can't be closed leads to locking of breaker fixed with mechanical interlock
Tripping voltage (V) (0.7~1.1)Us
Closing electromagnet: 1.Power voltage of closing electromagnet shouldn't lessthan 85%Us;
Break time (ms) <30
1.Rated control voltage is lessthan 85%Us; 2.Replace the electromagnet.
2.Closing electromagnet is damaged
Tripping after Tripping immediately: 1.Check the breaking current value and operation time of intelligent release;
Under-voltage release
closing the circuit 1.Short circuit current is closed 2.Exclude the short circuit fault if it happens.
The under-voltage release consists of release coil and control units. breaker (Fault 2.Delay tripping because of transient current 3.Exclude the overload fault.
The under-voltage release works in two ways: instantaneous operation and indicator flashing) is high when closing; 4.Check the normal state of breaker
delayed operation. 3.Overload current is closed 5.Modify the current setting value of intelligent release.
Operational accessory 6.Press the reser button to reclose the breaker.
Circuit breaker The breaker can't be opened manually 1.Check the mechanism, if there is fault happened.
Rated control power voltage Ue(v) AC400, AC230 can't be opened 1.There is fault with mechanical operating mechanism
Tripping voltage (V) (0.35~0.7)Ue The breaker can't be opened by motor remotely 1.Check the mechanism, if there is fault happened.
Reliable switch-on voltage(V) (0.85~1.1)Ue 1.There is fault with mechanical operating mechanism 2.Check the power voltage of shunt release is less than 70% or not.
Reliable switch-off voltage(V) ≤0.35Ue 2.Power voltage of shunt release is less than 70%Us; 3.Replace shunt release.
Power consumption 12VA 3.Shunt release is damaged
Delay time of under-voltage delayed release (s) 0.5, 1, 2, 3 Circuit breaker Manual storage can't be realized Mechanical fault with the energy-storage device.
can't store energy Motor storage can't be realized 1.Power voltage of motor energy-stored device shouldn't less than 85%Us.
Note: If the delay time of under-voltage delayed release is above 3 second, 1.power voltage of motor energy-stored device is less 2.Mechanical fault with the energy-storage device.

it is the special specification than 85%Us;


2.There is mechanical fault with energy-storage device.
Handle of drawerout-type circuit 1.There is padlock at the "opening position" 1.Take away the padlock.

Auxiliary contact breaker can't be drawn in or out 2.Slideway or breaker body isn't Pulled into its position 2.Pull the slideway or breaker body into its position.
Drawerout-type breaker can't be 1.Handle isn't pulled out 1.Pull out the handle.
Standard configuration we provided to client is four convertible contacts.
drawn out at the "opening"position 2.Breaker is not totally at the "opening"position 2.Keep the circuit breaker to totally at "opening"position
The six convertible contacts, four normally open, four normally closed
Drawerout-type breaker can't 1.Something drop into the drawer base, and lock the 1.Check and clean the drawer base,or contact with manufacture.
contacts or six normally open, normally closed contacts are also available
reach the "making"position mechanism or mechanism fault happens. 2.Match the body with relevant drawer base.
for special applications 2.Breaker body not match with the frame-size rated
current of drawer base.
Conventional thermal Rated control
Rated voltage (V) No display on intelligent 1.Release isn't connected with power 1.Check the power is connected or not.
current Ith(A) capacity
release panel 2.There is fault with release 2.Cut off the power, then connect again.Otherwise contact with manufacturer
230 Closing electromagnet; 1.Check the electromagnet power voltage shouldn't be less than 85%Us.
AC 830VA
415 10 1.Rated control voltage is less than 85%Us; 2.Replace the closing electromagnet.
DC 250 75W 2.Electromagnet is damaged
Fault indicator still flashing after Fault happened with intelligent release Cut off the power, then connect again. Otherwise contact with manufacturer.
pressing the clear button

42 www.sassin.com www.sassin.com 43
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Outline and installation dimensions (3SW68-1600)4P Drawer type

3SW68-1600/3P Drawer type


Vertical terminal Horizontal terminal

318
Vertical terminal Horizontal terminal
248

51
Ø11 15
51

Ø11 15

50
25
150

150
50
25

351
351

150
Power Distribution Electrics

Power Distribution Electrics


72
51 72 51
4xØ6.5 95 74
4xØ 6.5 95 74 74 215
74 145
297
297
282 352 297
297

Installation dimensions of door Vertical terminal Horizontal terminal

Installation dimensions of door Vertical terminal Horizontal terminal

70 70 70 70 70 70
276 50
276 70 70 70 70 265
44 25
265 230
230 25 a

15
Ø11
a Ø11

35 35
35

364
353
364
353

317
352

317
352
Button of Button of
breaker breaker

7
8xØ3.5 Center Center
of door Center Center
of breaker 8xØ3.5 of breaker of door

Rated current a(mm) Rated current a(mm)


200-6300A 5 200-6300A 5
800-1000A 10 800-1000A 10
1250-1600A 15 1250-1600A 15

44 www.sassin.com www.sassin.com 45
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

(3SW68-1600)3P Fixed type (3SW68-1600)4P Fixed type

Vertical terminal Horizontal terminal Vertical terminal Horizontal terminal

15
Ø11
Ø11 15

15
15
320

60
52
150
320
60
52
16

150

150
150

52
52 52 52

50
50
Power Distribution Electrics

Power Distribution Electrics


100 90 100 90
4xØ7
4xØ7

237 194 194


324
254 194 194

Installation dimensions of door Vertical terminal Horizontal terminal


Installation dimensions of door Vertical terminal Horizontal terminal

276 276
70 70 70 70
265 265
230 Ø11 50 230 70 70 70
70 70 70
50 Ø11
25
a
25
35
a

15
15

330
319
330
319

283
283

Button of Button of
breaker breaker

Center Center Center


8xØ3.5 of door of breaker of door
Center
of breaker 8xØ3.5

Rated current a(mm) Rated current a(mm)


200-6300A 5 200-6300A 5
800-1000A 10 800-1000A 10
1250-1600A 15 1250-1600A 15

46 www.sassin.com www.sassin.com 47
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

Special wiring 3SW68-1600 (Darwer type) (3SW68-2500) Fixed type

Forward outlet plate Level on the outlet plate forward On the board before the next level of inlet and outlet
3P N 3P N 4P 3P Horizontal wiring
50 Φ11 A
25
3P N 420(P)
15

325(P) Chamber door


248

130

304.5
244.5
420

79

H
403
130
15 15.5

135
Forward under the outlet plate on the vertical On the board before the next vertical inlet and outlet
Mounting hole center
3P N

56.5
Power Distribution Electrics

Power Distribution Electrics


3P N Mounting hole
347(3P) 30.5 170 98
4-Ø8 367(3P) 308.5
422(4P)
366
462(4P)
244.5

A Vertical wiring
A
Horizontal wiring Mounting hole center
N 3P 248 Chamber door

Extended busbar size of the breaker


95 95 95 78.5
70
77 77 77 Φ10 30
77

15
38.5 38.5 38.5
5-Φ11 38.5 5-Φ11 5-Φ11 5-Φ11
25 25 25 25 25 25
25 25

30
Φ10
15
15
15
15

30
30

70
30
82

82
52
52

82
52
52
82

Vertical wiring

135
30

95 95 95 78.5
25 13.5 25 13.5 25 13.5
25 13.5 H

15
52 52 52 Mounting hole center
52
90.5 102

56.5
30
Used as the extended busbar Used as the center extended Used as the extended busbar Used as the extended busbar in the left 30.5 170 98
center-left or right of the busbar of the horizontal, front in the left or right of the or right of the horizontal, front board 308.5
366
horizontal,front board inlet and board inlet and outlet wire horizontal, front board inlet and inlet and outlet wire combination of a
outlet wire combination of a combination of a 3-pole circuit outlet wire combination of a 4-pole circuit breaker
4-pole circuit breaker, and also breaker 3-pole circuit breaker
available as that of the vertical inlet
and outlet wire combination of 3 or
4-pole circuit breaker

Rated Current (In) Female cable(H)


Note: Use the busbar to connect the screws; Class M10 is of 8.8 torque: and 50 Nm should be used with the contact washer. 1250A 1600A 2000A 2500A 15mm 15mm 20mm 20mm

48 www.sassin.com www.sassin.com 49
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

(3SW68-2500) Fixed type (3SW68-4000) Fixed type

4P 3P Horizontal wiring
4P 3P Horizontal wiring
Chamber door 544(4P)
418(3P)
A

3200~4000A 2000~2500A
248 Chamber door
A A

403
450

30

20
10
10
135

135
135
Mounting hole
4-Ø8 440(3P) Mounting hole center
460(3P)

56.5
56.5
56.5

566(4P)
Power Distribution Electrics

Power Distribution Electrics


Mounting hole center 586(4P) 30.5 170 98
403
308.5
247(3P)
Mounting hole 366
4-Ø8 347(3P)
369(4P) 107.5 175 100
A
442(4P) 390 47 position Horizontal wiring Mounting hole center
455 N 3P

2000~2500A
126 126 126 94
70
Ø13 30

15
Vertical wiring

30
Chamber door
A
A

Horizontal wiring 3200~4000A 136 79


N 141(3P) 141(3P)
3P
Mounting hole center 136(4P) 136(4P) 100 Vertical wiring
Ø13
50

25
95 95 95 Φ10
70

50
Φ10 30 3200~4000 A 2000~2500 A
15

Chamber door
70
30

A A 248
30

135

Vertical wiring
2000~2500A 126 126 126 94
Vertical wiring Ø13

15

100
95 95 95 42

50
126

70
30
30
H
15

135
Ø13

135
30

107.5 175 100


Mounting hole center
380 47 position 3200~4000A 126 126 126 94

71.5

56.5
455 30
10 403 30.5 170 98

25
308.5
366

50
Rated Current (In) Female cable(H)
1250A 1600A 2000A 2500A 15mm 15mm 20mm 20mm

50 www.sassin.com www.sassin.com 51
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW68

(3SW68-4000) Darwer type (3SW68-1600) Fixed type

4P 3P Horizontal wiring

2000~2500A Chamber door


A
Mounting hole centerline The center line of door openings

4P 3P Mounting hole centerline


8-Ø
5

450

135

307.5
255

100
286
Door openings

126
Mounting hole center

325(3P) 57.5 107.5 175 100 47 position


440(3P) 390
Power Distribution Electrics

Power Distribution Electrics


540(4P) 63 455
Installation base of circuit breaker
566(4P)

(2.5)

Horizontal wiring Vertical wiring 115


A 260
225
Horizontal wiring Mounting hole center 3200~4000A 3200~4000A
N 3P
A A
2000~2500A 36.5(P)
126 126 126
10

31(4P)
30

Ø13 (3SW68-1600) Darwer type

100
10

50
15

135
30

Ø13
135

3200~4000A Mounting hole centerline The center line of door openings


126

136 141(3P) 141(3P) 21.5(3P)


4P 3P
141

136(4P) 136(4P) 100 16(4P)


Ø13 Mounting hole centerline
50
25

492 8-Ø
5
492
50

Vertical wiring Chamber door


2000~2500A
Vertical wiring
2000~2500A A
126 126 126 36.5(P)

351
290
31(4P) Door openings

110
322
15

Ø13
30

70
30
135

3200~4000A
126 126 126 36.5(P) Installation base of circuit breaker
31(4P)
(2.5)
25

126

Mounting hole center 115


270
240
50

107.5 175 100 47 position


390
455

52 www.sassin.com www.sassin.com 53
Air Circuit Breakers Air Circuit Breakers
Series 3SW68 Series 3SW8

(3SW68-4000)Fixed type Overview

Mounting hole centerline


The center line of door openings
4P 3P

8-Ø Mounting hole centerline


4

285 Door openings 10 9 8

317
11
Power Distribution Electrics

Power Distribution Electrics


13.5

Installation base of circuit breaker

355 (42.5)
220 393 12

13
(3SW68-4000)Darwere type
2

3 1

14

Mounting hole centerline The center line of door openings 7 6 4


4P 3P 5

Mounting hole centerline


11

4
153
281

Door openings
153
45 18
44.5

Installation base of circuit breaker Body 1


19
73

1 5 Auxiliary contact 9 Drawer base 13 Release


355 (42.5)
2 Body 2 6 Operating mechanism 10 Arcing chamber 14 Under-voltage release
162.5(3P) 393
157(4P)
3 Fixed plate 7 Intelligent controller 11 Transtormers

4 lock breaking device 8 Motor 12 Auxiliary switch

54 www.sassin.com www.sassin.com 55
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

Applications and functions Instruction of type

Incoming-feeder and outgoing-feeder function in W8 A F 3 L H 400


distribution systems
Rated current
Switching and protecting large powers, motors, capacitors,
400, 630, 800, 1000, 1250, 1600, 2000 (Frame A)
generators,transformers, busbars and cables 2000, 2500, 2900, 3200, 4000 (Frame B)
Overload protection 4000, 5000, 6300 (Frame C)
Connection type
Short-time delayed short-circuit protection
H: Horizontal terminal connection
Instantaneous short-circuit protection V: Vertical terminal connection
Used in building,industry,energy and infrastrustures Intelligent controller model
L: L type
M: M type
H: H type
Poles: 3: 3P; 4: 4P
Technical specifications:
Installation type
F: Fix type
Type 3SW8-2000 3SW8-3200 3SW8-6300 D: Drawer type
Standard IEC60947-2 IEC60947-2 IEC60947-2 Frame
Power Distribution Electrics

Power Distribution Electrics


Approval CE CE CE A: 3SW8-2000
Frame type A B C B: 3SW8-3200
Rated frame current Inm (A) 2000 3200 6300 C: 3SW8-6300
Number of poles 3,4 3,4(not for 4000A) 3,4 Series code
Rated current In (A) 400 630 800 1000 2000,2,500 4000 5000 6300
1250 1600,2000 2 9 0 0,3200 4 0 00
Rated frequency (Hz) 50/60 50/60 50/60 Intelligent controller characteristics
Rated voltage, Ue (V) 400,690 400,690 400,690
Rated insulating voltage Ui (V) 1000 1000 1000
Rated impulsed withstand voltage, Uimp (Kv) 12 12 12 Function Model L M H
N-pole rated current 100%In 100%In 100%In Basic protection Overload protection
Rated ultimate short-circuit breaking capacity, Icu Short circuit short delay protection
(AC) 50-60 Hz 400V O-CO (kA) 80 100 120 Instantaneous short-circuit protection
(AC) 50-60 Hz 690V O-CO (kA) 50 65 75 Ground fault protection or neutral pole protection G / N
Rated operating short-circuit breaking capacity, Ics Additional Function MCR ○ ○ ○
(AC) 50-60 Hz 400V O-CO (kA) 50 80 100 Thermal memory
(AC) 50-60 Hz 690V O-CO (kA) 40 50 65 Contact loss indication ○
Rated short-circuit making capacity (peak),Icm Self-diagnosis ○
(AC) 50-60 Hz 400V (kA) 176 220 264 Fault memory
(AC) 50-60 Hz 690V (kA) 105 143 165 Test
Rated short-time withstand current for 1s Icw (kA) Operation times ○
(AC) 50-60 Hz 400V (kA/s) 50 80 100 Parameterization Fault trip display
(AC) 50-60 Hz 690V (kA/s) 40 50 65 and display Load monitor display ○
Making time (mS) 25-30 25-30 25-30 Current display
Breaking time (mS) 70 70 70 Time display —
Electrical life (times) in 400V 6000 3000 1000 Measurement Current measurement —
in 690V 3000 1500 800 Voltage measurement — ○ ○
Mechanical life (times) without maintenance 15000 10000 4000 Frequency measurement — ○ ○
with maintenance 30000 20000 8000 Power measurement — ○ ○
Mounting position Power factor measurement — ○ ○
30° 30° 30° 30° Phase sequence detection — ○ ○
30° 30° 30° 30°
Voltage unbalance measurement — ○ ○
Electric power measurement — ○ ○
Harmonic measurement — ○ ○
Overvoltage protection — ○ ○
Installation type Fixed /Drawer Fixed(not for 4000A) /Drawer Drawer Undervoltage protection — ○ ○
Dismension (mm) HxWxD HxWxD HxWxD HxWxD HxWxD HxWxD Voltage unbalance protection — ○ ○
Fixed,3P 402x362x322 402x422x322 - - - - Over frequency protection — ○ ○
Fixed, 4P 402x362x322 402x537x322 - - - - Under-frequency protection — ○ ○
Drawer, 3P 433x375x420 433x435x420 450x550x492 - 450x930x492 450x930x492 Phase sequence protection — ○ ○
Drawer, 4P 433x375x420 433x550x420 - 450x390x492 450x930x492 450x930x492 Reverse power protection — ○ ○
Type of intelligent controller Electronic type L, Standard type M, Communication type H Comunication Communication Interface — — ○
Ambient temperature -5 to +40℃, max. 95 % humidity Achieve communication through the Modbus — — ○
Storage temperature -40 to +75℃ Achieve communication through the Profibus-DP — — ○
Altitude( Max) 2000 Achieve communication through the Device Net — — ○

Note: Intelligent controller function: standard — unavailable ○ selectable


Comnunication function is optional, not for the M-type communication and for the H-type communication protocol can select
Modbus, Profibus-DP, Device net.

56 www.sassin.com www.sassin.com 57
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

Normal Operation and Installation Conditions Installation

Ambient temperature: -5℃ ~ +40℃, and the average temperature is not exceeding +35℃ within 24h; Following items to be checked before installation
Altitude: Not higher than 2000m. The capacity should be decreased if the altitude is above 2000m Check the label plate on the breaker panel to see if it conforms to the specifications of the ordered goods.
Humidity: When the ambient air temperature is +40℃, the relative humidity of the air shall not be higher than 50%, a higher relative Rated current;
humidity is allowed at a lower temperature. For example, the relative humidity should be 90% when temperature is 20℃. Special Under voltage release voltage and delay time;
measures should be adopted for the condensation occasionally produced due to temperature change. Shunt release voltage;
Pollution degree: 3 Closing electromagnet voltage;
The circuit breaker can be used in electromagnetic environment A Motor voltage.
Installing category: IV for main circuit; III for other auxiliary and control circuits; Before installation, operation, maintenance and inspection, you shall read this manual, and consult the manufacturer for questions
The vertical gradient: no more than 5° if any.
Mounting Ambient: There must be no explosive medium, no gas which would corrode metal or any conducting dust which would Preparations before installation
destroy the insulation; Before the breaker is installed, check the insulation resistance of the breaker by using a 1000V megohmmeter according to
The circuit breakers should be installed in the compartment of switchgear cabinet with doorframes fixed additionally. Protection regulations; when the surrounding media temperature is 25℃±5℃ and the relative humidity is 5%~70%, the insulation resistance
grade is up to IP40. shall not be less than 20 megohm.
The place with the insulation resistance to be tested includes: the place between various phases and between various phases and
Power Distribution Electrics

the frame when the breaker is closed; the place between in-and out-lines of various phases when the breaker is switched off.

Power Distribution Electrics


Product structure
Installation of the fixed type breaker
Place the breaker into the distribution cabinet, and fasten it by using 4 pieces of M6(Inm=1600A) or M10(Inm=3200A or above)
3SW8 series ACB has fixed type and drawer type. Putting the fixed breaker into the drawer base becomes drawer type circuit
bolts and washers; the breaker shall be installed stably with no d=additional mechanical stress to avoid damage of the breaker or
breaker. The breaker is consist of contact system, arc extinction system, operation mechanism, intelligent controller, auxiliary
bad contact of the main bus bar and the secondary circuit. After the work is completed, mount the body into the draw-out socket.
switch, secondary circuit wiring terminal, under voltage release, shunt release, closed coil, etc.
The specification of the wiring copper bars for the primary circuit of the breaker shall meet the copper bar specification used
under the conditions of conventional heating in GB14048.2.
Drawer type
The breaker shall be grounded substantially

1.Rocker hole
2. "Separation", "Test" and "Connection" three-position Indicator Power loss

3. Intelligent controller
8 4.ON-OFF switch button Power loss is the total loss measured when the breaker is charged with the rated current
5.Switch off button
6.Trip indicator and reset button Breaker type Rated current(A) Draw-out type(w) Fixed type(w)

7.“opening” lock mechanism 200 115 45


7
6 400 140 80
9 8.Secondary circuit terminals
630 161 100
5 10 9.Switch on button
3SW8-1600 800 215 110
4 11 10.Manual charging handle 1000 230 120
12 11.Energy charging and discharging Indicator 1250 250 130
3 1600 460 220
12.Nameplate
1600 390 170
13 13.Mask
2000 470 250
14.Safety padlock mechanism on “Separation” indicator 2500 600 260
3SW8-3200
15. Rocker operating hole 3200 670 420
4000 550 -
2 1 15 14 3SW8-6300 5000 590 -
Note:
6300 950 -
"Separation" indicates that main circuit and secondary circuit
are both in isolation.
"Test": indicates that main circuit is in isolation and secondary Note: The data and parameters in the above technical documentation result from tests and theoretical calculation, and can only bu

circuit is in connection. used as a general type selection guide. They cannot replace industrial pratical experience or proof test.

"Connection": indicates that main circuit and secondary circuit


are both in connection.

58 www.sassin.com www.sassin.com 59
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

Recommended bus for the breaker and recommendation for users to install the buses Note:
1) If the control voltage of F, X, M are different, they should connect different power source

Cooper bar 2) Terminal 35# can connect the power source directly (automatic pre-energy storage), After series connecting with normally open
Frame current Inm(A) Rated current In(A)
Number Measurement(mm×mm) button, it can connect the power source (manual pre-storage)
200 1 20×5 3) The #6 - #7 are normally closed terminal if user requires
400 1 50×5
4) Additional accessory should be self-provided by user
630 2 40×5
1600 800 2 50×5
1000 3 40×5
Abbreviation Meaning Abbreviation Meaning
1250 4 40×5
SB1 Under-voltage button (self-provided by user) DF Auxiliary contact
1600 2 50×10
SB2 Shunt button (self-provided by user) F Shunt release
630 2 50×5
SB3 Switching on button SA Motor micro operation switch
800 2 60×5
X Closing electromagnet Q Under-voltage release or under voltage time delay release
1000 2 60×5
M Energy storage motor ⊗ Signal light (self-provided by user)
2500 1250 3 60×5
XT Terminal
1600 2 60×10
2000 3 60×10
2500 4 60×10
2000 3 60×10 Pin function
Power Distribution Electrics

2500 4 100×5 1#, 2#: Auxiliary power source input terminal 1# is“+”if it is direct current

Power Distribution Electrics


2900 3 100×10 3#, 4#, 5#: Fault trip contact output (#4 is common terminal), contact capacity: AC250V/16A
4000
3200 4 100×10
6#, 7# & 8#, 9#: Two groups breaker status auxiliary contacts, contact capacity: AC250V/16A
3600 4 100×10
4000 4 100×10 12#, 19#: DO signal alarm output, function: normally open, overload pre-alarm, contact capacity AC 250V/5A
4000 4 100×10 16#, 19# : DO signal alarm output, function: normally open, ground trip or alarm, contact capacity AC 250V/5A
6300 5000 6 100×10 20#, 19# : DO signal alarm output, function: normally open, self-diagnosis alarm, contact capacity AC 250V/5A
6300 6 100×10
21#, 19# : DO signal alarm output, function: normally open, OCR fault trip, contact capacity AC 250V/5A
25#, 26# : External current transformer input terminal (only 3P+N is available)

Secondary circuit wiring diagram

Secondary circuit wiring equipped with M, H type intelligent controller


Secondary circuit wiring equipped with L type intelligent controller

Under- Closing Electric


Main 3SW8-M, H Intelligent controller Shunt electro- energy Auxiliary contact-operated by user
voltage
Under- Closing Electric circuit release magnet storage
Main Shunt release
3SW8-L Intelligent controller voltage electro- energy Auxiliary contact-operated by user
circuit release magnet storage Energy storage Switch on Switch off
release
indication indication indication
Energy storage Switch on Switch off
indication indication indication Dedicated
connection wire
Fault indication ZCT1 and ZT100 Open Closed
External-line
分 合 Red Green transformer SB1 E SB2 E SB3 E
Fault indication
SB1 E SB2 E SB3 E

5 6 8 10 12 14 16 18 20 22 24 26 27 29 31 33 35 36 38 39 41 42 44 45 47 FU
FU
5 6 8 10 12 14 16 18 20 22 24 26 27 29 31 33 35 36 38 39 41 42 44 45 47 XT
XT

Control
DW Q F X M power
Control supply
DW Q F X M power DF
source
DF TA
Intelligent controller
TA
Circuit
Intelligent controller breaker
Circuit SA
breaker
SA
FU
FU
1 2 3 4 7 9 11 13 15 17 19 21 23 25 28 30 32 34 37 40 43 46

1 2 3 4 7 9 11 13 15 17 19 21 23 25 28 30 32 34 37 40 43 46 + -

+ -
Work power AC400V/230V
supply
Working AC400V/230V
power supply Direct current power
source module
Direct current power
source module DC220V/110V

DC220V/110V

60 www.sassin.com www.sassin.com 61
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

Note: SW8-M、H type intelligent controller connection interface


1) If the control voltage of F, X, M are different, they should connect different power source
2) Terminal 35# can connect the power source directly (automatic pre-energy storage), After series connecting with normally open A, B, C

button, it can connect the power source (manual pre-storage) N Connecting to the
3) The #6 - #7 are normally closed terminal if the client requires power input wire

4) Additional accessory should be self-provided by user

1 2 3 4 5 6 7 8 9 10 11 21 22 23 24

Meaning Meaning A (+) B (-) A (+) B (-) U1 U2


Abbreviation Abbreviation Un U3
SB1 Under-voltage button (self-provided by user) DF Auxiliary contact Power input Communication Voltage measurement
interface signal output
SB2 Shunt button (self-provided by user) F Shunt release
DW
SB3 Switching on button SA Motor micro operation switch
X Closing electromagnet Q Under-voltage release or under-voltage time delay release
3SW8 Intelligent controller
Signal light (User prepares) The auxiliary contact
M Energy storage motor ⊗ synchronized with breaker
Linear signal coil
XT Terminal
L1~L4

D03 and DI2 D04 and DI1


Power source
transformer
Pin function Grounding or current D01 D02 Earth
P1~P3
leakage external protection
1#, 2#: Auxiliary power source input terminal 1# is“+” if it The pin is connected with the output terminal of external
Power Distribution Electrics

Power Distribution Electrics


transformer input

is direct current. Because the controller has several optional transformer ZT100 if the earth protection way is current 25 26 12 13 14 15 16 17 18 19 20

types of power source, please note the input power source returned type (T)
is same with the working power source of the controller; The pin is connected with the output terminal of external Programmable input
and output contact
Grounding plate ZT100
otherwise the controller will be broken. ZCT rectangle transformer if the ground mode is current ZCT of centre point

3#, 4#, 5#: Fault trip contact output (#4 is common terminal), leakage type.
contact capacity: AC250V/16A The pin is connected with external added N phase
6#, 7# & 8#, 9#: Two groups of breaker status auxiliary transformer is when the ground protection mode is 3P+N
contacts, contact capacity: AC250V/16A value difference type.
10#, 11#: Communication interface output, the three Com-
munication protocol outputs are the same. 10#、11# are
empty if there is no communication( communication output).
12#,19#:(DO:DC11V 0.5A, AC250V, 5A.DI: DC110V~13V
or AC110V~AC250V)
When the signal unit type is S1: (4DO mode)
12#, 13#: Programmable output contact 1 (DO1)
14#, 15#: Programmable output contact 2 (DO2)
16#, 17#: Programmable output contact 3 (DO3)
18#, 19#:Programmable output contact 4 (DO4)
When the signal unit type is S2: (3DO+1DI mode)
12#, 13#: Programmable output contact 1 (DO1)
14#, 15#: Programmable output contact 2 (DO2)
16#, 17#: Programmable Discrete Output (DO3)
18#, 19#: Programmable Discrete Output (DI1)
When the signal unit type is S3: (2DO+2DI mode)
12#, 13#: Programmable output contact 1 (DO1)
14#, 15#: Programmable output contact 2 (DO2)
16#, 17#: Programmable Discrete Output 2 (DI3)
18#, 19#: Programmable Discrete Output 1 (DI1)
20# is the earth protection line of the controller
21#-24# pins are voltage signal input terminal, connecting
with the input side of the power by correct order. The pin
is empty if there is no added function
25#, 26# pin are used for input of external transformer

62 www.sassin.com www.sassin.com 63
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

Selection and ordering data Frame A M type controller

3SW8-2000 Vertical terminal connection


Rated current Number of Fixed type Drawer type
Frame A L type controller
In (A) poles Type code Order code Type code Order code
3SW8-2000 Horizontal terminal connection
400 3P W8AF 3MV400 27816 W8AD 3MV400 27802
Rated current Number of Fixed type Drawer type
4P W8AF 4MV400 27844 W8AD 4MV400 27830
In (A) poles Type code Order code Type code Order code
630 3P W8AF 3MV630 27818 W8AD 3MV630 27804
400 3P W8AF 3LH400 27997 W8AD 3LH400 27977
4P W8AF 4MV630 27846 W8AD 4MV630 27832
4P W8AF 4LH400 32444 W8AD 4LH400 32430
800 3P W8AF 3MV800 27820 W8AD 3MV800 27806
630 3P W8AF 3LH630 28001 W8AD 3LH630 27981
4P W8AF 4MV800 27848 W8AD 4MV800 27834
4P W8AF 4LH630 32446 W8AD 4LH630 32432
1000 3P W8AF 3MV1000 27822 W8AD 3MV1000 27808
800 3P W8AF 3LH800 28003 W8AD 3LH800 27985
4P W8AF 4MV1000 27850 W8AD 4MV1000 27836
4P W8AF 4LH800 32448 W8AD 4LH800 32434
1250 3P W8AF 3MV1250 27824 W8AD 3MV1250 27810
1000 3P W8AF 3LH1000 28005 W8AD 3LH1000 27987
4P W8AF 4MV1250 27852 W8AD 4MV1250 27838
4P W8AF 4LH1000 32450 W8AD 4LH1000 32436
1600 3P W8AF 3MV1600 27826 W8AD 3MV1600 27812
1250 3P W8AF 3LH1250 28007 W8AD 3LH1250 27989
4P W8AF 4MV1600 27854 W8AD 4MV1600 27840
4P W8AF 4LH1250 32452 W8AD 4LH1250 32438
2000 3P W8AF 3MV2000 27828 W8AD 3MV2000 27814
1600 3P W8AF 3LH1600 32426 W8AD 3LH1600 27991
4P W8AF 4MV2000 27856 W8AD 4MV2000 27842
4P W8AF 4LH1600 32454 W8AD 4LH1600 32440
2000 3P W8AF 3LH2000 32428 W8AD 3LH2000 27993
H type controller
4P W8AF 4LH2000 32456 W8AD 4LH2000 32442
Power Distribution Electrics

Power Distribution Electrics


Horizontal terminal connection
vertical terminal connection
400 3P W8AF 3HH400 27871 W8AD 3HH400 27857
400 3P W8AF 3LV400 27998 W8AD 3LV400 27978
4P W8AF 4HH400 27899 W8AD 4HH400 27885
4P W8AF 4LV400 32445 W8AD 4LV400 32431
630 3P W8AF 3HH630 27873 W8AD 3HH630 27859
630 3P W8AF 3LV630 28002 W8AD 3LV630 27982
4P W8AF 4HH630 27901 W8AD 4HH630 27887
4P W8AF 4LV630 32447 W8AD 4LV630 32433
800 3P W8AF 3HH800 27875 W8AD 3HH800 27861
800 3P W8AF 3LV800 28004 W8AD 3LV800 27986
4P W8AF 4HH800 27903 W8AD 4HH800 27889
4P W8AF 4LV800 32449 W8AD 4LV800 32435
1000 3P W8AF 3HH1000 27877 W8AD 3HH1000 27863
1000 3P W8AF 3LV1000 28006 W8AD 3LV1000 27988
4P W8AF 4HH1000 27905 W8AD 4HH1000 27891
4P W8AF 4LV1000 32451 W8AD 4LV1000 32437
1250 3P 1250 3P W8AF 3HH1250 27879 W8AD 3HH1250 27865
W8AF 3LV1250 28008 W8AD 3LV1250 27990
4P W8AF 4HH1250 27907 W8AD 4HH1250 27893
4P W8AF 4LV1250 32453 W8AD 4LV1250 32439
1600 3P W8AF 3HH1600 27881 W8AD 3HH1600 27867
1600 3P W8AF 3LV1600 32427 W8AD 3LV1600 27992
4P W8AF 4HH1600 27909 W8AD 4HH1600 27895
4P W8AF 4LV1600 32455 W8AD 4LV1600 32441
2000 3P W8AF 3HH2000 27883 W8AD 3HH2000 27869
2000 3P W8AF 3LV2000 32429 W8AD 3LV2000 27994
4P W8AF 4HH2000 27911 W8AD 4HH2000 27897
4P W8AF 4LV2000 32457 W8AD 4LV2000 32443
Vertical terminal connection
400 3P W8AF 3HV400 27872 W8AD 3HV400 27858
M type controller
4P W8AF 4HV400 27900 W8AD 4HV400 27886
Horizontal terminal connection
630 3P W8AF 3HV630 27874 W8AD 3HV630 27860
400 3P W8AF 3MH400 27815 W8AD 3MH400 27801
4P W8AF 4HV630 27902 W8AD 4HV630 27888
4P W8AF 4MH400 27843 W8AD 4MH400 27829
800 3P W8AF 3HV800 27876 W8AD 3HV800 27862
630 3P W8AF 3MH630 27817 W8AD 3MH630 27803
4P W8AF 4HV800 27904 W8AD 4HV800 27890
4P W8AF 4MH630 27845 W8AD 4MH630 27831
1000 3P W8AF 3HV1000 27878 W8AD 3HV1000 27864
800 3P W8AF 3MH800 27819 W8AD 3MH800 27805
4P W8AF 4HV1000 27906 W8AD 4HV1000 27892
4P W8AF 4MH800 27847 W8AD 4MH800 27833
1250 3P W8AF 3HV1250 27880 W8AD 3HV1250 27866
1000 3P W8AF 3MH1000 27821 W8AD 3MH1000 27807
4P W8AF 4HV1250 27908 W8AD 4HV1250 27894
4P W8AF 4MH1000 27849 W8AD 4MH1000 27835
1600 3P W8AF 3HV1600 27882 W8AD 3HV1600 27868
1250 3P W8AF 3MH1250 27823 W8AD 3MH1250 27809
4P W8AF 4HV1600 27910 W8AD 4HV1600 27896
4P W8AF 4MH1250 27851 W8AD 4MH1250 27837
2000 3P W8AF 3HV2000 27884 W8AD 3HV2000 27870
1600 3P W8AF 3MH1600 27825 W8AD 3MH1600 27811
4P W8AF 4HV2000 27912 W8AD 4HV2000 27898
4P W8AF 4MH1600 27853 W8AD 4MH1600 27839
2000 3P W8AF 3MH2000 27827 W8AD 3MH2000 27813
4P W8AF 4MH2000 27855 W8AD 4MH2000 27841

64 www.sassin.com www.sassin.com 65
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

Frame B L type controller Frame B H type controller

3SW8-3200 Horizontal terminal connection 3SW8-3200 Vertical terminal connection


Rated current Number of Fixed type Drawer type Rated current Number of Fixed type Drawer type
In (A) poles Type code Order code Type code Order code In (A) poles Type code Order code Type code Order code
2000 3P W8BF 3LH2000 32466 W8BD 3LH2000 32458 2000 3P W8BF 3HV2000 27954 W8BD 3HV2000 27946
4P W8BF 4LH2000 32482 W8BD 4LH2000 32474 4P W8BF 4HV2000 27970 W8BD 4HV2000 27962
2500 3P W8BF 3LH2500 32468 W8BD 3LH2500 32460 2500 3P W8BF 3HV2500 27956 W8BD 3HV2500 27948
4P W8BF 4LH2500 32484 W8BD 4LH2500 32476 4P W8BF 4HV2500 27972 W8BD 4HV2500 27964
2900 3P W8BF 3LH2900 32470 W8BD 3LH2900 32462 2900 3P W8BF 3HV2900 27958 W8BD 3HV2900 27950
4P W8BF 4LH2900 32486 W8BD 4LH2900 32478 4P W8BF 4HV2900 27974 W8BD 4HV2900 27966
3200 3P W8BF 3LH3200 32472 W8BD 3LH3200 32464 32200 3P W8BF 3HV3200 27960 W8BD 3HV3200 27952
4P W8BF 4LH3200 32488 W8BD 4LH3200 32480 4P W8BF 4HV3200 27976 W8BD 4HV3200 27968
4000 3P W8BF 3LH4000 32516 W8BD 3LH4000 32514 4000 3P W8BF 3HV4000 28000 W8BD 3HV4000 27996
4P - - - - 4P - - - -
Vertical terminal connection
2000 3P W8BF 3LV2000 32467 W8BD 3LV2000 32459 Frame C Ltype controller
4P W8BF 4LV2000 32483 W8BD 4LV2000 32475 3SW8-6300 Horizontal terminal connection
2500 3P W8BF 3LV2500 32469 W8BD 3LV2500 32461 4000 3P W8CF- 3LH4000 32496 W8CD 3LH4000 32490
4P W8BF 4LV2500 32485 W8BD 4LV2500 32477 4P W8CF- 4LH4000 32508 W8CD 4LH4000 32502
2900 3P W8BF 3LV2900 32471 W8BD 3LV2900 32463 5000 3P W8CF- 3LH5000 32498 W8CD 3LH5000 32492
Power Distribution Electrics

Power Distribution Electrics


4P W8BF 4LV2900 32487 W8BD 4LV2900 32479 4P W8CF- 4LH5000 32510 W8CD 4LH5000 32504
32200 3P W8BF 3LV3200 32473 W8BD 3LV3200 32465 6300 3P W8CF- 3LH6300 32500 W8CD 3LH6300 32494
4P W8BF 4LV3200 32489 W8BD 4LV3200 32481 4P W8CF- 4LH6300 32512 W8CD 4LH6300 32506
4000 3P W8BF 3LV4000 32517 W8BD 3LV4000 32515 Vertical terminal connection
4P - - - - 4000 3P W8CF 3LV4000 32497 W8CD 3LV4000 32491
4P W8CF 4LV4000 32509 W8CD 4LV4000 32503
M type controller 5000 3P W8CF 3LV5000 32499 W8CD 3LV5000 32493
Horizontal terminal connection 4P W8CF 4LV5000 32511 W8CD 4LV5000 32505
2000 3P W8BF 3MH2000 27921 W8BD 3MH2000 27913 6300 3P W8CF 3LV6300 32501 W8CD 3LV6300 32495
4P W8BF 4MH2000 27937 W8BD 4MH2000 27929 4P W8CF 4LV6300 32513 W8CD 4LV6300 32507
2500 3P W8BF 3MH2500 27923 W8BD 3MH2500 27915
4P W8BF 4MH2500 27939 W8BD 4MH2500 27931 M type controller
2900 3P W8BF 3MH2900 27925 W8BD 3MH2900 27917 Horizontal terminal connection
4P W8BF 4MH2900 27941 W8BD 4MH2900 27933 4000 3P W8CF 3MH4000 28015 W8CD 3MH4000 28009
3200 3P W8BF 3MH3200 27927 W8BD 3MH3200 27919 4P W8CF 4MH4000 28027 W8CD 4MH4000 28021
4P W8BF 4MH3200 27943 W8BD 4MH3200 27935 5000 3P W8CF 3MH5000 28017 W8CD 3MH5000 28011
4000 3P W8BF 3MH4000 27983 W8BD 3MH4000 27979 4P W8CF 4MH5000 28029 W8CD 4MH5000 28023
4P - - - - 6300 3P W8CF 3MH6300 28019 W8CD 3MH6300 28013
Vertical terminal connection 4P W8CF 4MH6300 28031 W8CD 4MH6300 28025
2000 3P W8BF 3MV2000 27922 W8BD 3MV2000 27914 Vertical terminal connection
4P W8BF 4MV2000 27938 W8BD 4MV2000 27930 4000 3P W8CD 3MV4000 28016 W8CF 3MV4000 28010
2500 3P W8BF 3MV2500 27924 W8BD 3MV2500 27916 4P W8CD 4MV4000 28028 W8CF 4MV4000 28022
4P W8BF 4MV2500 27940 W8BD 4MV2500 27932 5000 3P W8CD 3MV5000 28018 W8CF 3MV5000 28012
2900 3P W8BF 3MV2900 27926 W8BD 3MV2900 27918 4P W8CD 4MV5000 28030 W8CF 4MV5000 28024
4P W8BF 4MV2900 27942 W8BD 4MV2900 27934 6300 3P W8CD 3MV6300 28020 W8CF 3MV6300 28014
32200 3P W8BF 3MV3200 27928 W8BD 3MV3200 27920 4P W8CD 4MV6300 28032 W8CF 4MV6300 28026
4P W8BF 4MV3200 27944 W8BD 4MV3200 27936
4000 3P W8BF 3MV4000 27984 W8BD 3MV4000 27980 H type controller
4P - - - - Horizontal terminal connection
4000 3P -
W8CF 3HH4000 28039 W8CD 3HH4000 28033
H type controller 4P -
W8CF 4HH4000 28051 W8CD 4HH4000 28045
Horizontal terminal connection 5000 3P -
W8CF 3HH5000 28041 W8CD 3HH5000 28035
2000 3P W8BF 3HH2000 27953 W8BD 3HH2000 27945 4P -
W8CF 4HH5000 28053 W8CD 4HH5000 28047
4P W8BF 4HH2000 27969 W8BD 4HH2000 27961 6300 3P -
W8CF 3HH6300 28043 W8CD 3HH6300 28037
2500 3P W8BF 3HH2500 27955 W8BD 3HH2500 27947 4P -
W8CF 4HH6300 28055 W8CD 4HH6300 28049
4P W8BF 4HH2500 27971 W8BD 4HH2500 27963 Vertical terminal connection
2900 3P W8BF 3HH2900 27957 W8BD 3HH2900 27949 4000 3P -
W8CF 3HV4000 28040 W8CD 3HV4000 28034
4P W8BF 4HH2900 27973 W8BD 4HH2900 27965 4P -
W8CF 4HV4000 28052 W8CD 4HV4000 28046
3200 3P W8BF 3HH3200 27959 W8BD 3HH3200 27951 5000 3P -
W8CF 3HV5000 28042 W8CD 3HV5000 28036
4P W8BF 4HH3200 27975 W8BD 4HH3200 27967 4P -
W8CF 4HV5000 28054 W8CD 4HV5000 28048
4000 3P W8BF 3HH4000 27999 W8BD 3HH4000 27995 6300 3P -
W8CF 3HV6300 28044 W8CD 3HV6300 28038
4P - - - - 4P -
W8CF 4HV6300 28056 W8CD 4HV6300 28050

66 www.sassin.com www.sassin.com 67
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

Intelligent controller selection M type - controller panel structure instruction

1. Reset button 1. Reset button


Three types of Intelligent controller: M-type controller, adopt button setting, digit and lights
2. Rated current labels 2. Rated current labels
L type – Electronic type(Histogram display current, dial for
display mode, featured by large range of protection
adjustment) 3. Operation indicator 3. Voltage display
parameters which can be reorganize accordingly to
M type – Standard type (figures display current, button for 4. 40% ~ 100% Ir1 current light beam indicator 4. Three-phase line voltage and maximum voltage indicator
different application requirement, suitable for most
adjustment) 5. Overload indicator 5. Voltage- checking button
H type – Communication type (figures display current, button industrial applications. 6. Three-phase current display
6. Code switch for ground fault protection
adjusting and for communication) 7. Current and time indicator
7. Code switch for long delayed overload current
protection 8. Four-phase, ground and the maximum phase current
L type - controller panel structure instruction 1 indicator
8. Code switch for short time delayed overload current
9. Current- checking button
protection Reset
L-type controller adopts code switch and pull switch, simply and 10. Long time delayed overload fault indicator
9. Code switch for instantaneous short-circuit current
easy to handle.
protection
3SW8-M 11. Short time delayed short circuit fault indicator
Intelligent controller 12. Light clear reset button
10. Fault indicator for instantaneous short-circuit
In = 4000A 2 13. Instantaneous short-circuit fault indicator
1 protection
14. Current setting for long time delayed overload
Reset
11. fault indicator short time delayed short circuit
protection and alarm indicator
Power Distribution Electrics

Power Distribution Electrics


protection v 3 15. Time setting indicator of long time delayed overload
12. Fault indicator for long time delayed overload
3SW8-L protection U
protection
16. Current setting for short time delayed short circuit
4
Intelligent controller 13. Fault Indicator for ground protection 5
protection and alarm indicator
Choose 2
3 UAB UBC UCA MAX
14. Pull switch for short time delayed short-circuit 6 17. Time setting indicator for short time delayed short
2 In = protection A
circuit protection
MCU 7
15. Pull switch for long time delayed overload protection 18. Instantaneous short circuit current protection settings
5 KA 8
16. Pull switch for time setting of ground protection and alarm indicator
%In 40 60 80 100 Over load
4 S
load current 17. Reset key 19. Fault checking button
35 9
18. Test trip button 20. Spare key
Test G L1 L2 L3 MAX Choose 3
Ir4 Ir1 Ir2 Ir3 19. Fault-checking button 10 21. Load monitoring 2, current setting and alarm indicator
0.6 0.6 0.6 0.6 34 11
0.5 0.7 0.5 0.7 0.5 0.7 0.5 0.7 Fault
22. Decrease button
6 0.4 0.8 0.4 0.8 0.4 0.4
0.8 0.8 9 Reset
0.3 OFF 0.3 OFF 0.3 OFF 0.3 OFF 33 Trip
Light 12 23. Increase button
0.2 0.2 0.2 0.2
7 xIn xIn xIn xIn 8 Note: 13
S 24.Power supply socket
12 32 14
(1) “OFF” function is available for every protection function, 25. Save button
13 10 tL 15
user can chose different protection functions as per actual 26. Extra Indicator
11 16
t
requirement. 31 tS 17 27. Non trip test button
tG
18
(2) MCU light; blink in normal operation, constantly light in 28. Trip test button
self-diagnostic fault. lr 4 l R1 l R2 l R3 A 29. Parameter setting button
30
(3) 40% to 100% light: show the percentage of maximum 29 19 30. Load monitoring 2, current setting and alarm indicator
phase current to IR1,the grade is 10%. Load1 Load2
check 20 31. Time setting indicator for ground protection
Set 21
tG tL tS 14 (4) Overload light: when the current reaches 1.15IR the 32. Ground protection current setting and alarm indicator
16 28 22
15 23 33. Fault trip indicator
0.2S 30S 0.2S overload light lighting; when IR = OFF, current reaches 27 Trip No-trip storage
24
DC24V
0.4S 60S 0.4S 25
1.15IR the overload light lighting. 26 34. Fault indicator for ground protection
0.6S 120S
0.8S 240S (5) Fault reason indicator: check the reason why Test adjust 35. Test status lights
19 17 malfunction. When fault tripping occurs, the light indicator
Test trip Test Reset 18
relevant fault reason, press the reset button to exit; if the Note:

power supply lost, press the check button to display the (1) Fault current signal appears when the M type controller
Figure: 3SW8-M-type control panel introduction
last fault trip reason when the power is on again. in the process of parameter setting, testing, fault checking,
(Power distribution protection) all the functional setting will be automatically turn off and
(6) Test trip button, check the status of release and circuit
enter the fault handling;
breakers.
(2) Cross-setting of protection parameters is forbidden
and make sure Ir1 <Ir2 <Ir3
(3)"Voltage display" is optional function, users should
specify when place order.

68 www.sassin.com www.sassin.com 69
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

M-type controller panel structure instruction H-type controller panel structure instruction

1. Reset button Instruction


1 2. Rated current labels 1. LCD display
Reset 3. Voltage display 7 2. Fault and alarm reset button
4. Three-phase line voltage and maximum voltage indicator 3. “Fault and alarm”LED
3SW8-M 5. Voltage- checking button LED indicator will not lighten when normal operation;
Intelligent controller 6. Three-phase current display LED flash quickly when maintenance; LED turned red
In = 4000A 2 7. Current and time indicator when alarm.
34 P PF
33 8. Four-phase, ground and the maximum phase current in 4. LED blinking green color on normal working condition
3
dicator 5. Communication indicator
1
v 9. Current- checking button Communication status as follows
10. Long time delayed overload fault indicator Light go out when no communication, keep lighting
U 11. Short time delayed short circuit fault indicator when in communication.
4 5 12. Light clear reset button 2 Light go out when no communication, keep flashing
UAB UBC UCA MAX Choose 2

6 13 .Instantaneous short-circuit fault indicator when in communication.


3
A 14. Current setting for long time delayed overload 6 Flashing when no communication, keep lighting when
Power Distribution Electrics

Power Distribution Electrics


7 protection and alarm indicator 4 in communication.
KA
15. Long time delayed overload protection time setting 5 6. Curve LED
S indicator The red LED hide inside curve. The corresponding LED
8
32 9 16. Current settings for short time delayed short circuit flashes to indicate the type of fault when fault trip occurs.
L1 L2 L3 MAX Choose 1
10 protection and alarm indicator LED constantly lighten to indicating the current set
Fault
11 17. Short time delayed short circuit protection time setting projects when protection of parameter settings.
Reset
31 Trip
Light 12 indicator 7. Reset button:
13 18. Instantaneous short circuit current protection settings Reset button pops up when tripping or test tripping. The
S
14
and alarm indicator circuit-breaker can’t switch on if the button hasn’t
tL 15
19. Fault checking button pressed down; press down the button and the fault
16
tS 20. Spare key indications will recovery.
17 16
18 21. Pre-alarm overload time setting indicator Keyboard
22. Decrease button 8. Measurement function key 1, can be switched to the
l R1 l R2 l R3 A
30 23. Increase button default theme menu. (Measurement function key is the
29 19
Ip Tp 20 24. Power supply socket "left" key in the password input interface).
Set check
21 25. Save button 9. Setting function key 2: can be switched to the parameter
28 22
23 26. Extra Indicator setting menu. (Setting function key is the "right" key in
27
DC24V 24 8 9 10 11
27. Non trip test button the password input screen).
25
26 28. Trip test button 10. Protection function key 3: switch to the parameter
Test adjust
29. Parameter setting button setting protection menu.
30. Pre-alarm overload current setting and alarm indicator 11. Information function 4: switch to history record and
31. Fault trip indicator menu maintenance.
32. Test status lights 12. Up - move up or change the parameters.
Figure :3SW8-M-type control panel introduction 33. Power factor measurement indicator 13. Down –move down or change the parameter.
(motor protection) 34. Active power measurement indicators 14. Exit - exit and enter the previous menu or cancel the
12 13 14 15
current selected parameters.
Note: 15. Choice –enter into the next menu or select the
(1)No ground fault protection for motor protection type. parameters and save the amendment.
(2)"Voltage display" is optional function, users should s 16. Test port
pecify when place order. There is a 16-pin test plug at the bottom of the front
panel, a portable power pack or detection unit can be
insert able.

70 www.sassin.com www.sassin.com 71
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

Intelligent controller protection characteristic of type M.H Current protection characteristic curve for intelligent controller

Overload thermal tripping L NO/OFF selectable Earth fault protection characteristic curve

Setting current value adjustment range Ir1 (0.4~1.0)Innon-pole adjustment


10000
Inverse time characteristic 1.05Ir1 2h no action t (s)
5000
Set by the user 1.30Ir1 ≤2h action
2000
1.5Ir tL(s) 1.50Ir1 15 30 60 120 240 480 Ir4=0.2ln-1.01ln
1000
±10% accuracy
2.00Ir1 8.4 16.9 33.8 67.5 135 270 500

6.00Ir1 0.94 1.88 3.75 7.50 15.0 30.0 200

7.20Ir1 0.65 1.30 2.60 5.20 10.0 21.0 100

Thermal memory (min) ≤30+off 50

Short-circuit short delay (s) NO/OFF Selectable 20

(1.0-15) Ir1no-pole adjustment 10


Setting current value adjustment
5
range Ir2 ±10% accuracy
2
Setting delay time ts(s) I>8Ir1 0.1 0.2 0.3 0.4
1
±15% accuracy Time to return 0.06 0.14 0.23 0.35
0.5 0.4s
Power Distribution Electrics

Power Distribution Electrics


With inverse time characteristic 0.3s
I≤8Ir1 0.2s
0.2
Thermal memory(min) ≤15 0.1s
0.1

IInstantaneous short-circuit (I) NO/OFF Selectable 0.05

Short-circuit current value adjustment 0.02


(1.0-20)In
range Ir3 ±15% accuracy
00801 02 03 05 081 152 3 5 8 10
G
Ground fault NO/OFF Selectable x ln
Setting current value adjustment (0.2-1.0) Ir1no-pole adjustment
Ig earth fault protection current setting value tg earth fault protection time setting value
range Ir4 ±10% accuracy

Ground fault delay time tG(s) s 0.1 0.2 0.3 0.4


Time to return ms 60 160 225 340
Maximum breaking time
Characteristics curve of overload protection
ms 140 240 345 460
Load monitoring 10000
t (s)
Two load limit lc1=In x... A 0.2~1(≤2% differential, min160A) 5000

tr1= 0.5t1, when 1.5Ic1, T=1.5Ir1xtr1/I² Ir1=0.4-1 X In


2000
lc2= In x... A 0.2~1(≤2% differential, min160A) 1000

tr2= 0.25t1, when 1.5Ic1, T=1.5Ir1xtr1/I² 500 tL=15S Ir1: Overload long-delay setting
One load limit and one reclose lc1=In x... A 0.2~1(≤2% differential, min160A) tL=30S
Ir2: Short-circuit short-delay current
200
tL=60S
tr1= 0.25t1, when 1.5Ic1, T=1.5Ir1xtr1/I² setting
100
tL=120S
lc2=In x... A 0.2~1(≤2% differential, min160A) 50
Ir3: Overload long-delay time setting
tL=240S
tr2= Fixed 60s tL=480S Tl: Instantaneous short-circuit current
20
setting
Accuracy ±10% Isd
10
Ts: Short-circuit short-delay time
Thermal memory(30min.clear power) Standard+off 5
Ir2=1-15 x In setting
Fault trip
2
Machinery Mechanical reset button (red)
Fault trip indication 1
Electrical installations Remote indication contact 0.5 t s=0.4S
Fault current time display Fault trip display Flash after fault trip
0.2 ts=0.3S
Show loss of main contact Fault trip display Overload time-lapse; short-circuit short delay; Ir3
ts=0.2S
0.1
short-circuit instantaneous; ground fault Ir3
0.05
Overcurrent fault alarm Digital display, LCD display Current value of fault like o ts=0.1S
0.02
Fault type display
Digital display, LCD display Display the current value
0.8 1 1.5 2 3 5 8 10 15 20
Trip button Test the current characteristic 30 40 50 80 100 120 200
Test × IR kA
Non trip button Test the current characteristic of electronic release tripping time

72 www.sassin.com www.sassin.com 73
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

Intelligent controller protection characteristic of type M、H

Overload Protection Load-monitor Protection (type 1)

10000 10000
5000
5000
2000 In=(0.4-1)In Ir1=(0.4~1)In
IIc1=(0.2~1)In
1000 tI=(15-480)s
2000 IIc2=(0.2~1)In
500
1000
200
500
100

50
200
20 tl=15-480s
100
10
50
5 Tlc2=tl/2
T(s) Ir2=(1-1.5)Ir1

2
T(s) Tlc2=tl/4
20
1
10
0.5 0.4
0.3
0.2 5
Power Distribution Electrics

Power Distribution Electrics


0.2
Ir3=In-50KA
0.1
0.1
2
0.05
1
0.02
0.01 0.5
0.005
0.2
0.002
0.001 0.1
0.5 0.6 0.8 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 0.05 0.06 0.08 0.1 0.2 0. 3 0. 4 0. 5 0. 6 0. 8 1 2 3 4 5 6 8 10 20 30
Xln Xln

Ground fault Protection Load-monitor Protection (type 2)

10000
10000
5000
5000
2000 Ir4=(0.2-0.8)In
MAX 1200A Ir1=(0.4-1)In
1000
MIN 160A 2000 IIc1=(0.2-1)In
500 IIc2=(0.2-1)In
1000
200
100 500

50
200
20 tl=15-480s
100
10
Tlc2=tl/4
50
5
T(s)
2 T(s) 20
1
Tlc2=60S
10
0.5 0.4

0.3 5
0.2
0.2
0.1 0.1
2
0.05
1
0.02
0.01 0.5
0.005
0.2
0.002
0.1
0.001
0.05 0.06 0.08 0.1 0.2 0. 3 0. 4 0. 5 0. 6 0. 8 1 3 4 5 6 8 10 20 30 0.05 0.06 0.08 0.1 0.2 0. 3 0. 4 0. 5 0. 6 0. 8 1 2 3 4 5 6 8 10 20 30

Xln Xln

74 www.sassin.com www.sassin.com 75
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

Accessory

Under-voltage release Electric operation mechanism


When circuit breaker is power off, it requires automatic break, user should The breaker is of operation mechanism energy storage and re-storage
adopt under-voltage instantaneous release; when breaker is instantaneous function.
power failure or under voltage, it does not require break, user adopt under- The breaker can store energy manually
voltage delay release. Thus, it is not a necessary accessory, it is optional. It
Characteristics:
should always connect the power source if circuit breaker is equipped with
such release. Rated control power source voltage Us (v) AC400, AC230, DC220, DC110
Tripping voltage (V) (0.85~1.1)Us
Note: Power consumption 192VA, 192W
In the thunderstorm-prone areas or in unstable voltage grids, it is Storage time (s) ≤5

recommended to use under voltage time-delayed release. It can prevent


the breaker tripping caused by instantaneous voltage decrease. The delayed
time are normally 0.5s, 1s, 2s, 3s, for user to choose.

Characteristics:
Disconnecting lock device
Power Distribution Electrics

Disconnecting lock device can lock the switch off button at the off location,

Power Distribution Electrics


Rated working voltage Ue (v) AC400, AC230
Tripping voltage (V) (0.35~0.7)Ue thus breaker can not be closed;
Reliable closing voltage (V) (0.85~1.1)Ue
The factory will provide the key and lock after user selects breaker;
Reliable open voltage (V) ≤0.35Ue
Power consumption 12VA
One circuit breaker is equipped with independent lock and key;
Two circuit breakers are equipped with two same locks and one key;
Three circuit breakers are equipped with three same locks and two keys.
Shunt release
Shunt release can break circuit breaker through remote operation instead
of on the spot, which can avoid contact with circuit breaker during circuit
operation and make worker safer. Shunt release can't always be connected
to power source, otherwise coil will be burned. Partition plate of the draw-out type circuit breaker;
The partition strengthens the busbar insulation. It is optional.
Characteristics:

Rated control power source voltage Us (v) AC400, AC230, DC220, DC110
Tripping voltage (V) (0.7~1.1)Us
Limit current 0.7, 1.3, 1.3, 2.4
Breaking time (ms) ≤30

Closing electromagnet
Closing electromagnet can switch on circuit breaker through remote
operation instead of on the spot, which can avoid contact with circuit
breaker during circuit operation and make worker safer. Such release can't Door frame

always be connected to power source, otherwise coil will be burned. It is fixed on the door cabinet and used as seal. Protection grade is up to IP40;

After energy storage is finished, the closing electromagnet will make the Beautiful and practical;

energy storage spring of operation mechanism to release its energy instantly The door frame has draw-out type (MK1) and fixed type.

so that the circuit breaker is closed rapidly.

Characteristics:

Rated control power source voltage Ue (v) AC400, AC230, DC220, DC110
Tripping voltage (V) (0.8~1.1)Us
Limit current (A) 0.7, 1.3, 1.3, 2.4
Closing time (ms) ≤ 70

76 www.sassin.com www.sassin.com 77
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

Common faults and troubleshooting Outline and installation dimensions

Listed below are the problems which users may encounter during installation, adjustment, and operation of the breaker, and the
Outline and installation dimensions 3SW8-400,630,800,1000,1250,1600,2000
possible reasons and elimination methods.
409
Fixed 3-pole 4-pole 314
No.Technical problems Possible causes Diagnosis and trouble shooting
Breaker tripping Overload fault tripping 1. Check the breaking current and operating time on the intellectual controller;
(fault indicator on) (long time delay indicator on) 2. Analyze the operation of the load and power metwork;
3. Promptly find and shoot the trouble if overload is comfimed;
4. For lack of match between the actual running current and the long time delay
operating current, please modify the long-time delay operating current setting for
a proper match and protection according to the actual running current; Starting point
5. press the reset button to close the breaker again.

402
a
Short-circuit fault tripping 1. Check the breaking current and operating time on the intellectual controller;
Panel center 170

112
(short time delay or instantaneous indicator on) 2. Promptly find and shoot the trouble if it is confirmed that there is a grounding fault; 11
Starting point4-Ø11 11 340( 3-Ploe )
3. Check the setting value of the intellectual controller; 11 435( 4-Ploe )
4. Check to see whether the breaker is in good condition, and detemine whether it

55
can be closed for operation;
60 150 68
5. press the reset button to close the breaker again.
278
Grounding fault tripping 1. Check the breaking current and operating time on the intellectual controller; 3-Ploe 12-Ø13
(grounding fault indicator on) 2. promply find and shoot the trouble if it is comfirmed that there is a grounding fault; 290 4-Ploe 16-Ø13
3. If no grounding fault is detected, please determine whether the grounding fault 60 Horizontal wiring
Power Distribution Electrics

Power Distribution Electrics


N
current setting shall be modified; 170
28
4. press the reset button to close the breaker again. Horizontal wiring L-type wiring
2 Breaker fails to close Under voltage release tripping 1. Check to see if the power voltage is lower than 70%Ue;

17
2. Check the under voltage release and control unit for fault; a
Mechanical interlock action Check the working condition of two breakers equipped with mechanical interlock. 95 95 95
Under voltage release no attracting 1. Whether the under voltage release has been energized; 20
L-type wiring

15

15
2. Whether the power voltage is lower than 85%Ue; 3-Ploe 12-Ø13
3. Whether the under voltage release or control unit malfunctions, if so , the release 4-Ploe 16-Ø13 60

267+a
shall be replaced.
28 170

267
Reset button fails to reset Press the reset button to close the breaker again.

112
a
Open frame (draw-out) circuit breaker fails to be Put the open frame(draw-out) circuit breaker to the right position by rocking (with

15
put to the right position by rocking it locked in the connection position)

55
Open frame (draw-out) circuit breaker bad contact Check the contact status of the secondary circuit, and shoot the trouble, if any

25
45

15
for the secondary circuit 64

15
32 95 95 95
Breaker fails to pre-store energy 1. Check the motor control power supply and see if it is well providing power, and
the voltage must be ≥85%Us; 41
2. Check the status of the motor energy storage mechanism.
Closing electromagnet trouble 1. Check the power voltage of the closing electromagnet, and it must be ≥85% Us; Vertical wiring Extended horizontal wiring 60
Vertical wiring
2. If there is any trouble in the closing electromagnet to enable the attracting, it a 170
shall be replaced.

12.5
Breaker trips after closed Tripping immediately Delay tripping 1. There may be short circuit current when the matter is switched on, and in this
3-Ploe 12-Ø13
case you shall find and shoot the trouble; 4 -Ploe 16-Ø13
2. Check to see if there is any overload current in the circuit, find and shoot the 95 95 95
trouble, if any.

60
3. Check to see whether the breaker mechanism is in good condition; 3-Ploe 24-Ø13 Extended horizontal wiring
4. Check the setting value of the intellectual controller for reasonability, and a 4 -Ploe 32-Ø13

112
112
resetting process is necessary if not reasonable; 60

55 a
28
5. Press the reset button to close the breaker again. 30 170
Breaker fails to open The breaker fails to open in power-driven mode 1. Check the shunt release circuit for reliable connection and the shunt release for

15
29.5 61
The breaker fails to open on manual mode trouble, and the release shall be replaced if the fault is confirmed;
34

30
2. Check the operating mechanism for mechanical fault.
81.5
Breaker fails to store Energy failed to be stored in power-driven mode 1. Check the motor energy storage mechanism control power voltage, and the
energy voltage shall be≥85%; check the status of the circuit connection; 4-Ø11 95 95 95
2. Check the motor;
Can't achieve manual energy storage Energy storage mechanism malfunction.
Breaker fails to be pulled out when Rock rod fails to be pulled out; breaker fails to Pull out the rock rod. Starting point

340(3-Ploe)
the open frame (draw-out) circuit completely reach the SEPARATION position Put the breaker completely to the SEPARATION position by rocking.

435( 4-Ploe )
breaker is in the SEPARATOPN position

362

457
Open frame (draw-out) circuit The “drawer” has seized up for foreign matters fall in it; Check it for foreign matters and for condition of the rack a gear.
breaker fails to be put to the damage in the mechanism for putting in by rocking or the Turn the key on the “drawer” to unlock the matter. Darwer 3-pole 4-pole
CONNECTION position by rocking gear thereof; position locking device fails to be unlocked. ln A a mm
No display on the Intellectual controller fails to be energized by power supply; 1. Check to see if the intellectual controller power supply is well connected and 400~800 10
intellectual controller improper input voltage for the auxiliary power supply; works well; 1000~1600 15
150 74
screen improper secondary output voltage for the transmitter; 2. Cut off the intellectual controller control power supply, and then connect the
2000 20
unreliable connection between the secondary output power supply; if the fault is still present, there may be some troubles in the
terminal of the transmitter and the controller; controller which bas to be replaced.

78 www.sassin.com www.sassin.com 79
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

Outline and installation dimensions 3SW8-400,630,800,1000,1250,1600,2000 Outline and installation dimensions 3SW8-2000,2500,2900,3200

Drawer type 3-pole 4-pole Fixed 3-pole 4-pole

489
374

Starting point

433

402
112 a

a
112
Starting point 4-Ø11 Starting point 4-Ø11 Starting point
92

Panel center 132.5

55
55 265( 3-Ploe ) 55
97 175 200
360( 4-Ploe ) 60 150 68
380 470 11 400( 3-Ploe ) 11
278 11
515
45 390
290

Horizontal wiring L-type wiring 3-Ploe 12-Ø13 Horizontal wiring Horizontal wiring L-type wiring
a 4-Ploe 16-Ø13
60
Power Distribution Electrics

Power Distribution Electrics


15

N 28 132.5 3-Ploe 18-Ø13


4-Ploe 24-Ø13 Horizontal wiring
86

14

20
95 95 95 50 200
359

17
112

3-Ploe 12-Ø13 L-type wiring

267
115 115 115
92 a

4-Ploe 16-Ø13 60

112
28 132.5 3-Ploe 18-Ø13

a
4-Ploe 24-Ø13 86 L-type wiring

55
15
63-a

15

30 10

45-a
50

20
200
32
64 a

20
95 95 95

Vertical wiring Extended horizontal wiring Vertical wiring Extended horizontal wiring
Vertical wiring 115 115 115
60
a 132.5
3-Ploe 24 -Ø13 Vertical wiring
12.5

3-Ploe 18-Ø13 4-Ploe 32 -Ø13 86


4-Ploe 24-Ø13 a 200
95 95 95

18
60

100
25
Extended horizontal wiring
112

3-Ploe 24-Ø13 115 115 115


112

4-Ploe 32-Ø13
28

112
a

60 3-Ploe 24-Ø13
Extended horizontal wiring
92

4-Ploe 32-Ø13

a
30 132.5

75
86

55
15

27.5 68
40 200
81
30

38 58

20
45.5
95 95 95

40
33 175
115 115 115
Starting point
2-11x27 Ø14
Starting point
265(3-Ploe)
360(4-Ploe)

150
74

Ø11
Darwer 3-pole 4-pole

4-Ø11
ln A a mm
400(3-Ploe) Darwer 3-pole 4-pole
400~800 10 ln A a mm
422
1000~1600 15 2000~2500 20
515(4-Ploe)
2000 20 537 2900~3200 30

80 www.sassin.com www.sassin.com 81
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

Outline and installation dimensions 3SW8-2000,2500,2900,3200 Outline and installation dimensions of breaker 3SW8-4000

Drawer 3-pole、4-pole
Drawer type 3-pole 4-pole

433
112 a

433
Starting point
Starting point 4-Ø11 Starting point

112
4-Ø11
92

162.5

30
Panel center

92
97 175 55 325(3-Ploe) 55
380 440(4-Ploe) 102 Panel center 162.5
45 390
550 55 55 55
97 175
550(3-pole)
380
Horizontal wiring 930(4-pole)
Horizontal wiring L-type wiring 45 390
3-Ploe 24-Ø13 100
a 4-Ploe 32-Ø13
75
Power Distribution Electrics

Power Distribution Electrics


N 25 162.5 197.5 197.5
40 17

182.5 246.5 246.5

140 150 140 100 160 160 160

14
50 50 50 50

20
50 50 50
115 125 125

50 20
50
369
112

3-Ploe 24-Ø13 L-type wiring


a

4-Ploe 32-Ø13 100 220


24-Ø13 351.5
92

40 162.5 32-Ø13
Starting point Starting point
30
73-a

10
Outline and installation dimensions of breaker 3SW8-5000、6300
115 125 125

Vertical wiring Extended horizontal wiring


Vertical wiring Drawer 3-pole、4-pole
100
a 162.5

3-Ploe 18-Ø13
18

4-Ploe 24-Ø13

115 125 125


100
75
25

Extended horizontal wiring

433
3-Ploe 24-Ø13
112

112
4-Ploe 32-Ø13 100 4-Ø11 Starting point
42 112+a

Starting point
162.5
a

50

30
92
92

25

38 97 175 102 Panel center 162.5


50

100
56 380 55 818 55
45 390 930
115 125 125
33 75

326.5 326.5 199.5 246.5 269


2-11x27 Ø14
Starting point
260 313 260 215 228 260
160 170
325(3-Ploe)
440(4-Ploe)

160 135 160 160 160


60 70 60 50 60 60 60
50 20

Ø11

Darwer 3-pole 4-pole


ln A a mm 48-Ø13 409 56-Ø13 351.5
2000~2500 20 Starting point Starting point
2900~3200 30

82 www.sassin.com www.sassin.com 83
Air Circuit Breakers Air Circuit Breakers
Series 3SW8 Series 3SW8

3SW8-2000(3- pole、4-pole)Door installation size Order specification

Fixed Drawer Please fill numbers in Please mark " " in □

Distributor name Assembling plant name

Project name Order amount

Model 3SW8- Order date

Pole ⃞ Three poles ⃞ Four poles


362
362 The right side of the Rated voltage ⃞ AC 400V ⃞ AC 690V
302 drawer block
302 Rated current In= A N pole rated currentIn ⃞ 50% In ⃞ 100% In
21

Connection Fixed type ⃞ Horizontal ⃞ Vertical

Draw-out type ⃞ Horizontal ⃞ Vertical

155
156 Type selection ⃞ L type
- Ø5
5 11 ⃞ M type ⃞ H type

270
8-Ø ⃞ L2 type ⃞ L3 type ⃞ L4 type

303
270

379
312
330

Basic function Over-load long time delay protection Ir1 t1

399

Intelligent controller
Short circuit short time delay protection Ir2 t2
262

20
Short circuit Instantaneous protection Ir3
Power Distribution Electrics

Power Distribution Electrics


Selective function □ MCR and HSICS protection (used for L, M type)

47
28

Underside of circuit 172.5 □ Voltage measurement function (used for M, H type)


breaker mounting plate Bottom of
345 172.5 Function meter function □D □U □P □H □UD □PD □HD (used for M, H type)
drawer block
345 Communication function □ modbus (used for H type)

□ profibus (used for H type)

□ devicenet (used for H type)


Intelligent controller voltage ⃞ AC 230V ⃞ AC 400V ⃞ DC 220V ⃞ DC 110V

Shunt release ⃞ AC 230V ⃞ AC 400V ⃞ DC 220V ⃞ DC 110V

Necessary accessories
3SW8-3200 ( 3-pole、4-pole)、3SW8-4000 ( 3-pole)、3SW8-6300(3-pole、4-pole)Door installation size Closing electromagnet ⃞ AC 230V ⃞ AC 400V ⃞ DC 220V ⃞ DC 110V

Electric operation mechanism ⃞ AC 230V ⃞ AC 400V ⃞ DC 220V ⃞ DC 110V

Auxiliary swtich Standard type ⃞ Four pieces of normally-open and four pieces of normally-closed contacts
Fixed Drawer
Special type ⃞ Six pieces of normally-open contacts and two pieces of normally-closed contacts

⃞ Two pieces of normally-open contacts and six pieces of normally-closed contacts

⃞ Three pieces of normally-open contacts and three pieces of normally-closed contacts

⃞ Under-voltage release ⃞ AC 230V ⃞ AC 400V

422 ⃞ Under-voltage instantaneous release ⃞ Under-voltage delay release


422 The right side of the ⃞ 0.5s □ 1s □ 2s □ 3s
362 36
21

drawer block
362 30 The far right of breaker
⃞ Mechnical interlock ⃞ One circuit breaker ⃞ One lock and one key
21

mounting plate

Optional accessories
⃞ Two sets circuit breaker ⃞ Steel cable lock interlock ⃞ Link rod interlock

⃞ Three sets circuit breaker ⃞ Two locks and one key


155

5
156


11 ⃞ Steel cable lock interlock ⃞ Link rod interlock Pattern one
5
270

8-Ø
303

⃞ Link rod interlock pattern two ⃞ Link rod interlock patterm three
270

379
330

399

⃞ Three locks and two keys


312

⃞ Neutral line N current tramsformer for external connection


324
20

⃞ Electrical indication mechanism on drawer base


0.5

⃞ Pushbutton lock mechanism ⃞ Counter ⃞ Partition plate


47
28

Underside of circuit 203


Bottom of
breaker mounting plate 406 203
drawer block
406

84 www.sassin.com www.sassin.com 85
Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Overview Applications and functions

1. Body Incoming and outgoing function in distribution systems


Switching and protection of short circuit and overload for motors, transformers and capacitors
2. Plug-in base
Stopping and switching off in an emergency in conjunction with lockable rotary operating mechanisms and terminal covers
3. Electronic release
Available in the following versions :
4. Drawer type base System protection:the overload and short-circuit releases are designed for the protection of cables, leads and non-motor loads.
10
Motor protection:the overload and short-circuit releases are designed for optimized protection and direct-on-line starting of
5. Rotary manual operating handle
induction squirrel-cage motors.
6. Motor driven operating mechanism

7. Shunt release
Features
8. Under-voltage release

9. Alarm contact 9
Complete current range
10. Auxiliary contact
1600A
11. Rear connection plate 1250A
1000A
Power Distribution Electrics

Power Distribution Electrics


12. Front connection plate 800A
8 700A
13. Cage clamp terminal 630A
500A
400A
350A
315A
250A
225A
200A
180A
160A
125A
2 100A
7 80A
63A
50A
40A
32A
25A
20A
16A
12.5A
3

1
High-breaking capacity
(1) B: Basic breaking capacity type (4) H: High-breaking capacity type
5
(2) N: Normal breaking capacity type (5) G: Ultrahigh breaking capacity type
(3) S: Standard breaking capacity type (6) X : Current limit type
11

Rated ultimate short circuit breaking capacity Icu


6 4
Frame rated current 20kA 35kA 50kA 65kA 85kA 100kA
A: 125A B N
B: 160A B N S
12 C: 250A N S H X
5 D: 400A N S H
E: 630A N S H
4 F: 800A N S H X
G: 1250A S H G
H: 1600A S H G

13
5

86 www.sassin.com www.sassin.com 87
Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Microprocess controlled Instruction of type code


3SM29 series circuit breaker(Inm>=250)adopt advanced microprocess electronic release that can intelligentize the protection.
M29 A T F 3 B 125
Convenient installation
Rated current
3SM29 series circuit breaker provides three installation types as follow:
Fixed installation with front connection and rear connection Breaking capacity: B, N, S, H, G, X

Plug-in installation with front connection and rear connection Poles(P): 3, 4


Drawer installation
Installation type:
F: Fixed type; P: Plug in type; D: Drawer type

T: Thermal Magnetic Type


E: Electronic Type

Frame:
A: 3SM29-125; B: 3SM29-160; C: 3SM29-250
D: 3SM29-400; E: 3SM29-630; F: 3SM29-800
G: 3SM29-1250; H: 3SM29-1600
Power Distribution Electrics

Power Distribution Electrics


Series code
Technical specifications

Type 3SM29-630 3SM29-1250


3SM29-125 3SM29-160 3SM29-250 3SM29-400
3SM29-800 3SM29-1600
Standards IEC60947-2 IEC60947-2 IEC60947-2 IEC60947-2 IEC60947-2 IEC60947-2
Approvals CE CE CE,CB,KEMA CE CE CE
Frame type A B C D E, F G,H
Poles (No) 3, 4 3, 4 3, 4 3, 4 3, 4 3
N-pole rated current =In =In =In =In =In =In
Frame Current Inm (A) 125 160 250 400 630, 800 1250,1600
Rated current In (A) 12.5, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 32, 40, 50, 63, 80, 100, 125, 160 125, 160, 180, 200, 225, 250 250, 315, 350, 400 400, 500, 630, 700, 800 800, 1000, 1250, 1600
Rated insulating voltage Ui (V) 500 690 690 690 690 690
Rated service voltage Ue (V) 400 400 400 400 400 400
Rated frequency in AC (Hz) 50/60 50/60 50/60 50/60 50/60 50/60
Rated impulsed withstand voltage Uimp (Kv) 6 6 8 8 8 8
Class of breaking capacity B N B N S N S H X N S H N S H X S H G
Rated ultimate short-circuit breaking capacity, Icu (kA)
(AC) 50-60 Hz 400V O-CO (kA) 20 35 20 35 50 35 50 65 100 35 50 65 35 50 65 100 50 65 85
(AC) 50-60 Hz 690V O-CO-CO 15 20 16 25 35 20 30 35 70 20 30 35 20 30 35 70 30 35 50
Rated operating short-circuit breaking capacity, Ics
(AC) 50-60 Hz 400V O-CO-CO (kA) 10 17.5 10 17.5 25 35 37.5 48.8 75 35 37.5 48.8 35 37.5 48.8 75 50 48.75 50
(AC) 50-60 Hz 690V O-CO-CO (kA) - - 5 10 15 20 30 35 50 20 30 35 20 35 30 50 35 35 35
Rated short-time withstand current for 1s (kA) - - - 5 10 20
Mechanical life (times) 8500 7000 7000 4000 4000 2500
Electrical life (times) 1500 1000 1000 1000 1000 500
Flashover distance (mm) ≤30 ≤30 ≤50 ≤50 ≤80 ≤80
Thermal magnetic release
Electronic release - -
Utilization category (IEC60947-2) A A A A, B A, B A, B
Motor control mechanism
Rotary handle operation mechanism
Shunt and under voltage release
Auxiliary contact and alarm contact
Dismension W H
W (mm) 3P 76 90 105 105 140 210 210 210
4P 101 120 140 140 184 280 280 280
L (mm) 3P 120 120 170 254 254 268 406 406
4P 120 120 170 254 254 268 406 406
L

H (mm) 3P 70 70 103.5 103.5 103.5 103.5 103.5 138.5


4P 70 70 103.5 103.5 103.5 103.5 103.5 138.5
Weight Fixed 3P/4P 0.92/1.3 1.2/1.6 2.7/3.5 5 5.1/7 9.6/12.2 17.2/22.2
Plug in 3P/4P 1.2/1.5 1.4/1.8 3.2/4.2 8.2 6.2/8.5 - -
Withdrawable 3P/4P - - 3.6/4.6 9 6.5/8.7 12.2/15.3 22/30.1
Ambient temperature -5 ~ 40℃, max. 95 % humidity -5~+40℃, max. 95 % humidity
Storage temperature -40 ~ +75℃ -40~+75℃
Altitude (Max) 2,000 2,000

88 www.sassin.com www.sassin.com 89
Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Selection and ordering data Thermal Magnetic Type


Breaking Rated Fixed type Plug in type Drawer type
capacity current(A) Poles Type code Order code Type code Order code Type code Order code
Thermal Magnetic Type
3SM29-160 35kA (N) 32 3 M29BTF 3N32 10580 M29BTP 3N32 34355 - -
Breaking Rated Fixed type Plug in type Drawer type - -
4 M29BTF 4N32 10604 M29BTP 4N32 10612
capacity current(A) Poles Type code Order code Type code Order code Type code Order code - -
40 3 M29BTF 3N40 10581 M29BTP 3N40 34356
3SM29-125 20kA (B) 12.5 3 M29ATF 3B12.5 10484 M29ATP 3B12.5 10506 - - - -
4 M29BTF 4N40 10605 M29BTP 4N40 10613
4 M29ATF 4B12.5 10528 M29ATP 4B12.5 10550 - - - -
50 3 M29BTF 3N50 10582 M29BTP 3N50 34357
16 3 M29ATF 3B16 10485 M29ATP 3B16 10507 - - - -
4 M29BTF 4N50 10606 M29BTP 4N50 10614
4 M29ATF 4B16 10529 M29ATP 4B16 10551 - - - -
63 3 M29BTF 3N63 10583 M29BTP 3N63 34358
20 3 M29ATF 3B20 10486 M29ATP 3B20 10508 - - - -
4 M29BTF 4N63 10607 M29BTP 4N63 10615
4 M29ATF 4B20 10530 M29ATP 4B20 10552 - - - -
80 3 M29BTF 3N80 10584 M29BTP 3N80 34359
25 3 M29ATF 3B25 10487 M29ATP 3B25 10509 - - - -
4 M29BTF 4N80 10608 M29BTP 4N80 10616
4 M29ATF 4B25 10531 M29ATP 4B25 10553 - - - -
100 3 M29BTF 3N100 10585 M29BTP 3N100 34360
32 3 M29ATF 3B32 10488 M29ATP 3B32 10510 - - - -
4 M29BTF 4N100 10609 M29BTP 4N100 10617
4 M29ATF 4B32 10532 M29ATP 4B32 10554 - - - -
125 3 M29BTF 3N125 10586 M29BTP 3N125 34361
40 3 M29ATF 3B40 10489 M29ATP 3B40 10511 - - - -
4 M29BTF 4N125 10610 M29BTP 4N125 10618
4 M29ATF 4B40 10533 M29ATP 4B40 10555 - - - -
160 3 M29BTF 3N160 10587 M29BTP 3N160 34362
50 3 M29ATF 3B50 10490 M29ATP 3B50 10512 - - - -
4 M29BTF 4N160 10611 M29BTP 4N160 10619
4 M29ATF 4B50 10534 M29ATP 4B50 10556 - - -
50kA (S) 32 3 M29BTF 3S32 10588 M29BTP 3S32 10596 -
63 3 M29ATF 3B63 10491 M29ATP 3B63 10513 - - -
4 M29BTF 4S32 34363 M29BTP 4S32 10620 -
4 M29ATF 4B63 10535 M29ATP 4B63 10557 - - -
40 3 M29BTF 3S40 10589 M29BTP 3S40 10597 -
80 3 M29ATF 3B80 10492 M29ATP 3B80 10514 - - - -
Power Distribution Electrics

4 M29BTF 4S40 34364 M29BTP 4S40 10621

Power Distribution Electrics


4 M29ATF 4B80 10536 M29ATP 4B80 10558 - - -
50 3 M29BTF 3S50 10590 M29BTP 3S50 10598 -
100 3 M29ATF 3B100 10493 M29ATP 3B100 10515 - - -
4 M29BTF 4S50 34365 M29BTP 4S50 10622 -
4 M29ATF 4B100 10537 M29ATP 4B100 10559 - - -
63 3 M29BTF 3S63 10591 M29BTP 3S63 10599 -
125 3 M29ATF 3B125 10494 M29ATP 3B125 10516 - - -
4 M29BTF 4S63 34366 M29BTP 4S63 10623 -
4 M29ATF 4B125 10538 M29ATP 4B125 10560 - - -
80 3 M29BTF 3S80 10592 M29BTP 3S80 10600 -
35kA (N) 12.5 3 M29ATF 3N12.5 10495 M29ATP 3N12.5 10517 - - - -
4 M29BTF 4S80 34367 M29BTP 4S80 10624
4 M29ATF 4N12.5 10539 M29ATP 4N12.5 10561 - - - -
100 3 M29BTF 3S100 10593 M29BTP 3S100 10601
16 3 M29ATF 3N16 10496 M29ATP 3N16 10518 - - - -
4 M29BTF 4S100 34368 M29BTP 4S100 10625
4 M29ATF 4N16 10540 M29ATP 4N16 10562 - - - -
125 3 M29BTF 3S125 10594 M29BTP 3S125 10602
20 3 M29ATF 3N20 10497 M29ATP 3N20 10519 - - - -
4 M29BTF 4S125 34369 M29BTP 4S125 10626
4 M29ATF 4N20 10541 M29ATP 4N20 10563 - - - -
160 3 M29BTF 3S160 10595 M29BTP 3S160 10603
25 3 M29ATF 3N25 10498 M29ATP 3N25 10520 - - - -
4 M29BTF 4S160 34370 M29BTP 4S160 10627
4 M29ATF 4N25 10542 M29ATP 4N25 10564 - -
32 3 M29ATF 3N32 10499 M29ATP 3N32 10521 - -
3SM29-250 35kA (N) 125 3 M29CTF 3N125 10371 M29CTP 3N125 10638 M29CTD 3N125 10656
4 M29ATF 4N32 10543 M29ATP 4N32 10565 - -
4 M29CTF 4N125 10674 M29CTP 4N125 10692 M29CTD 4N125 16011
40 3 M29ATF 3N40 10500 M29ATP 3N40 10522 - -
160 3 M29CTF 3N160 10372 M29CTP 3N160 10639 M29CTD 3N160 10657
4 M29ATF 4N40 10544 M29ATP 4N40 10566 - -
4 M29CTF 4N160 10675 M29CTP 4N160 10693 M29CTD 4N160 16012
50 3 M29ATF 3N50 10501 M29ATP 3N50 10523 - -
180 3 M29CTF 3N180 10373 M29CTP 3N180 10640 M29CTD 3N180 10658
4 M29ATF 4N50 10545 M29ATP 4N50 10567 - -
4 M29CTF 4N180 10676 M29CTP 4N180 10694 M29CTD 4N180 16013
63 3 M29ATF 3N63 10502 M29ATP 3N63 10524 - -
200 3 M29CTF 3N200 10374 M29CTP 3N200 10641 M29CTD 3N200 10659
4 M29ATF 4N63 10546 M29ATP 4N63 10568 - -
4 M29CTF 4N200 10678 M29CTP 4N200 10695 M29CTD 4N200 16014
80 3 M29ATF 3N80 10503 M29ATP 3N80 10525 - -
225 3 M29CTF 3N225 10375 M29CTP 3N225 10642 M29CTD 3N225 10660
4 M29ATF 4N80 10547 M29ATP 4N80 10569 - -
4 M29CTF 4N225 10679 M29CTP 4N225 10696 M29CTD 4N225 16015
100 3 M29ATF 3N100 10504 M29ATP 3N100 10526 - -
250 3 M29CTF 3N250 10376 M29CTP 3N250 10643 M29CTD 3N250 10661
4 M29ATF 4N100 10548 M29ATP 4N100 10570 - -
4 M29CTF 4N250 10680 M29CTP 4N250 10697 M29CTD 4N250 16016
125 3 M29ATF 3N125 10505 M29ATP 3N125 10527 - -
50kA (S) 125 3 M29CTF 3S125 34377 M29CTP 3S125 10644 M29CTD 3S125 10662
4 M29ATF 4N125 10549 M29ATP 4N125 10571 - -
4 M29CTF 4S125 10680 M29CTP 4S125 10698 M29CTD 4S125 16017
160 3 M29CTF 3S160 34378 M29CTP 3S160 10645 M29CTD 3S160 10663
3SM29-160 20kA (B) 32 3 M29BTF 3B32 10572 M29BTP 3B32 34331 - -
4 M29CTF 4S160 10681 M29CTP 4S160 10699 M29CTD 4S160 16018
4 M29BTF 4B32 34339 M29BTP 4B32 34347 - -
180 3 M29CTF 3S180 34379 M29CTP 3S180 10646 M29CTD 3S180 10664
40 3 M29BTF 3B40 10573 M29BTP 3B40 34332 - -
4 M29CTF 4S180 10682 M29CTP 4S180 10700 M29CTD 4S180 16019
4 M29BTF 4B40 34340 M29BTP 4B40 34348 - -
200 3 M29CTF 3S200 34380 M29CTP 3S200 10647 M29CTD 3S200 10665
50 3 M29BTF 3B50 10574 M29BTP 3B50 34333 - -
4 M29CTF 4S200 10683 M29CTP 4S200 10701 M29CTD 4S200 16020
4 M29BTF 4B50 34341 M29BTP 4B50 34349 - -
225 3 M29CTF 3S225 34381 M29CTP 3S225 10648 M29CTD 3S225 10666
63 3 M29BTF 3B63 10575 M29BTP 3B63 34334 - -
4 M29CTF 4S225 10684 M29CTP 4S225 10702 M29CTD 4S225 16021
4 M29BTF 4B63 34342 M29BTP 4B63 34350 - -
250 3 M29CTF 3S250 34382 M29CTP 3S250 10649 M29CTD 3S250 10667
80 3 M29BTF 3B80 10576 M29BTP 3B80 34335 - -
4 M29CTF 4S250 10685 M29CTP 4S250 10703 M29CTD 4S250 16022
4 M29BTF 4B80 34343 M29BTP 4B80 34351 - -
100 3 M29BTF 3B100 10577 M29BTP 3B100 34336 - -
4 M29BTF 4B100 34344 M29BTP 4B100 34352 - -
125 3 M29BTF 3B125 10578 M29BTP 3B125 34337 - -
4 M29BTF 4B125 34345 M29BTP 4B125 34353 - -
160 3 M29BTF 3B160 10579 M29BTP 3B160 34338 - -
4 M29BTF 4B160 34346 M29BTP 4B160 34354 - -

90 www.sassin.com www.sassin.com 91
Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Thermal Magnetic Type Thermal Magnetic Type


Breaking Rated Fixed type Plug in type Drawer type Breaking Rated Fixed type Plug in type Drawer type
capacity current(A) Poles Type code Order code Type code Order code Type code Order code capacity current(A) Poles Type code Order code Type code Order code Type code Order code
3SM29-250 65kA (H) 125 3 M29CTF 3H125 10632 M29CTP 3H125 10650 M29CTD 3H125 10668 3SM29-630 400 3 M29ETF 3H400 34136 - - M29ETD 3H400 34172
65kA (H)
4 M29CTF 4H125 10686 M29CTP 4H125 16005 M29CTD 4H125 16023 4 M29ETF 4H400 34190 - - M29ETD 4H400 34226
160 3 M29CTF 3H160 10633 M29CTP 3H160 10651 M29CTD 3H160 10669 500 3 M29ETF 3H500 34137 - - M29ETD 3H500 34173
4 M29CTF 4H160 10687 M29CTP 4H160 16006 M29CTD 4H160 16024 4 M29ETF 4H500 34191 - - M29ETD 4H500 34227
180 3 M29CTF 3H180 10634 M29CTP 3H180 10652 M29CTD 3H180 10670 630 3 M29ETF 3H630 34138 - - M29ETD 3H630 34174
4 M29CTF 4H180 10688 M29CTP 4H180 16007 M29CTD 4H180 16025 4 M29ETF 4H630 34192 - - M29ETD 4H630 34228
200 3 M29CTF 3H200 10635 M29CTP 3H200 10653 M29CTD 3H200 10671 400 3 M29ETF 3X400 36394 - - M29ETD 3X400 34196
100kA (X)
4 M29CTF 4H200 10689 M29CTP 4H200 16008 M29CTD 4H200 16026 4 M29ETF 4X400 36406 - - M29ETD 4X400 36412
225 3 M29CTF 3H225 10636 M29CTP 3H225 10654 M29CTD 3H225 10672 500 3 M29ETF 3X500 36395 - - M29ETD 3X500 34197
4 M29CTF 4H225 10690 M29CTP 4H225 16009 M29CTD 4H225 16027 4 M29ETF 4X500 36407 - - M29ETD 4X500 36413
250 3 M29CTF 3H250 10637 M29CTP 3H250 10655 M29CTD 3H250 10673 630 3 M29ETF 3X630 36396 - - M29ETD 3X630 34198
4 M29CTF 4H250 10691 M29CTP 4H250 16010 M29CTD 4H250 16028 4 M29ETF 4X630 36408 - - M29ETD 4X630 36414
100kA (X) 125 3 M29CTF 3X125 34545 M29CTP 3X125 34551 M29CTD 3X125 34557
4 M29CTF 4X125 34563 M29CTP 4X125 34569 M29CTD 4X125 34575 3SM29-800 35kA (N) 400 3 M29FTF 3N400 34229 - - M29FTD 3N400 34244
160 3 M29CTF 3X160 34546 M29CTP 3X160 34552 M29CTD 3X160 34558 4 M29FTF 4N400 34259 - - M29FTD 4N400 34274
4 M29CTF 4X160 34564 M29CTP 4X160 34570 M29CTD 4X160 34576 500 3 M29FTF 3N500 34230 - - M29FTD 3N500 34245
180 3 M29CTF 3X180 34547 M29CTP 3X180 34553 M29CTD 3X180 34559 4 M29FTF 4N500 34260 - - M29FTD 4N500 34275
4 M29CTF 4X180 34565 M29CTP 4X180 34571 M29CTD 4X180 34577 630 3 M29FTF 3N630 34231 - - M29FTD 3N630 34246
200 3 M29CTF 3X200 34548 M29CTP 3X200 34554 M29CTD 3X200 34560 4 M29FTF 4N630 34261 - - M29FTD 4N630 34276
4 M29CTF 4X200 34566 M29CTP 4X200 34572 M29CTD 4X200 34578 700 3 M29FTF 3N700 34232 - - M29FTD 3N700 34247
Power Distribution Electrics

Power Distribution Electrics


225 3 M29CTF 3X225 34549 M29CTP 3X225 34555 M29CTD 3X225 34561 4 M29FTF 4N700 34262 - - M29FTD 4N700 34277
4 M29CTF 4X225 34567 M29CTP 4X225 34573 M29CTD 4X225 34579 800 3 M29FTF 3N800 34233 - - M29FTD 3N800 34248
250 3 M29CTF 3X250 34550 M29CTP 3X250 34556 M29CTD 3X250 34562 4 M29FTF 4N800 34263 - - M29FTD 4N800 34278
4 M29CTF 4X250 34568 M29CTP 4X250 34574 M29CTD 4X250 34580 50kA (S) 400 3 M29FTF 3S400 34234 - - M29FTD 3S400 34249
4 M29FTF 4S400 34264 - - M29FTD 4S400 34279
3SM29-400 35kA (N) 250 3 M29DTF 3N250 16029 M29DTP 3N250 16041 M29DTD 3N250 16053 500 3 M29FTF 3S500 34235 - - M29FTD 3S500 34250
4 M29DTF 4N250 16065 M29DTP 4N250 34097 M29DTD 4N250 34109 4 M29FTF 4S500 34265 - - M29FTD 4S500 34280
315 3 M29DTF 3N315 16030 M29DTP 3N315 16042 M29DTD 3N315 16054 630 3 M29FTF 3S630 34236 - - M29FTD 3S630 34251
4 M29DTF 4N315 16066 M29DTP 4N315 34098 M29DTD 4N315 34110 4 M29FTF 4S630 34266 - - M29FTD 4S630 34281
350 3 M29DTF 3N350 16031 M29DTP 3N350 16043 M29DTD 3N350 16055 700 3 M29FTF 3S700 34237 - - M29FTD 3S700 34252
4 M29DTF 4N350 34087 M29DTP 4N350 34099 M29DTD 4N350 34111 4 M29FTF 4S700 34267 - - M29FTD 4S700 34282
400 3 M29DTF 3N400 16032 M29DTP 3N400 16044 M29DTD 3N400 16056 800 3 M29FTF 3S800 34238 - - M29FTD 3S800 34253
4 M29DTF 4N400 34088 M29DTP 4N400 34100 M29DTD 4N400 34112 4 M29FTF 4S800 34268 - - M29FTD 4S800 34283
50kA (S) 250 3 M29DTF 3S250 16033 M29DTP 3S250 16045 M29DTD 3S250 16057 65kA (H) 400 3 M29FTF 3H400 34239 - - M29FTD 3H400 34254
4 M29DTF 4S250 34089 M29DTP 4S250 34101 M29DTD 4S250 34113 4 M29FTF 4H400 34269 - - M29FTD 4H400 34284
315 3 M29DTF 3S315 16034 M29DTP 3S315 16046 M29DTD 3S315 16058 500 3 M29FTF 3H500 34240 - - M29FTD 3H500 34255
4 M29DTF 4S315 34090 M29DTP 4S315 34102 M29DTD 4S315 34114 4 M29FTF 4H500 34270 - - M29FTD 4H500 34285
350 3 M29DTF 3S350 16035 M29DTP 3S350 16047 M29DTD 3S350 16059 630 3 M29FTF 3H630 34241 - - M29FTD 3H630 34256
4 M29DTF 4S350 34091 M29DTP 4S350 34103 M29DTD 4S350 34115 4 M29FTF 4H630 34271 - - M29FTD 4H630 34286
400 3 M29DTF 3S400 16036 M29DTP 3S400 16048 M29DTD 3S400 16060 700 3 M29FTF 3H700 34242 - - M29FTD 3H700 34257
4 M29DTF 4S400 34092 M29DTP 4S400 34104 M29DTD 4S400 34116 4 M29FTF 4H700 34272 - - M29FTD 4H700 34287
65kA (H) 250 3 M29DTF 3H250 16037 M29DTP 3H250 16049 M29DTD 3H250 16061 800 3 M29FTF 3H800 34243 - - M29FTD 3H800 34258
4 M29DTF 4H250 34093 M29DTP 4H250 34105 M29DTD 4H250 34117 4 M29FTF 4H800 34273 - - M29FTD 4H800 34288
315 3 M29DTF 3H315 16038 M29DTP 3H315 16050 M29DTD 3H315 16062 100kA (X) 400 3 M29FTF 3X400 34581 - - M29FTD 3X400 34586
4 M29DTF 4H315 34094 M29DTP 4H315 34106 M29DTD 4H315 34118 4 M29FTF 4X400 34591 - - M29FTD 4X400 34596
350 3 M29DTF 3H350 16039 M29DTP 3H350 16051 M29DTD 3H350 16063 500 3 M29FTF 3X500 34582 - - M29FTD 3X500 34587
4 M29DTF 4H350 34095 M29DTP 4H350 34107 M29DTD 4H350 34119 4 M29FTF 4X500 34592 - - M29FTD 4X500 34597
400 3 M29DTF 3H400 16040 M29DTP 3H400 16052 M29DTD 3H400 16064 630 3 M29FTF 3X630 34583 - - M29FTD 3X630 34588
4 M29DTF 4H400 34096 M29DTP 4H400 34108 M29DTD 4H400 34120 4 M29FTF 4X630 34593 - - M29FTD 4X630 34598
700 3 M29FTF 3X700 34584 - - M29FTD 3X700 34589
3SM29-630 35kA (N) 400 3 M29ETF 3N400 34124 - - M29ETD 3N400 34160 4 M29FTF 4X700 34594 - - M29FTD 4X700 34599
4 M29ETF 4N400 34178 - - M29ETD 4N400 34214 800 3 M29FTF 3X800 34585 - - M29FTD 3X800 34590
500 3 M29ETF 3N500 34125 - - M29ETD 3N500 34161 4 M29FTF 4X800 34595 - - M29FTD 4X800 34600
4 M29ETF 4N500 34179 - - M29ETD 4N500 34215
630 3 M29ETF 3N630 34126 - - M29ETD 3N630 34162
4 M29ETF 4N630 34180 - - M29ETD 4N630 34216
50kA (S) 400 3 M29ETF 3S400 34130 - - M29ETD 3S400 34166
4 M29ETF 4S400 34184 - - M29ETD 4S400 34220
500 3 M29ETF 3S500 34131 - - M29ETD 3S500 34167
4 M29ETF 4S500 34185 - - M29ETD 4S500 34221
630 3 M29ETF 3S630 34132 - - M29ETD 3S630 34168
4 M29ETF 4S630 34186 - - M29ETD 4S630 34222

92 www.sassin.com www.sassin.com 93
Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Electronic Type Electronic Type


Breaking Rated Fixed type Plug in type Drawer type Breaking Rated Fixed type Plug in type Drawer type
capacity current(A) Poles Type code Order code Type code Order code Type code Order code capacity current(A) Poles Type code Order code Type code Order code Type code Order code
3SM29-250 35kA (N) 125 3 M29CEF 3N125 34139 M29CEP 3N125 34145 M29CED 3N125 34151 3SM29-400 65kA (H) 250 3 M29DEF 3H250 36321 M29DEP 3H250 36325 M29DED 3H250 36329
4 M29CEF 4N125 34193 - - - - 4 M29DEF 4H250 36333 - - - -
160 3 M29CEF 3N160 34140 M29CEP 3N160 34146 M29CED 3N160 34152 315 3 M29DEF 3H315 36322 M29DEP 3H315 36326 M29DED 3H315 36330
4 M29CEF 4N160 34194 - - - - 4 M29DEF 4H315 36334 - - - -
180 3 M29CEF 3N180 34141 M29CEP 3N180 34147 M29CED 3N180 34153 350 3 M29DEF 3H350 36323 M29DEP 3H350 36327 M29DED 3H350 36331
4 M29CEF 4N180 34195 - - - - 4 M29DEF 4H350 36335 - - - -
200 3 M29CEF 3N200 34142 M29CEP 3N200 34148 M29CED 3N200 34154 400 3 M29DEF 3H400 36324 M29DEP 3H400 36328 M29DED 3H400 36332
4 M29CEF 4N200 34196 - - - - 4 M29DEF 4H400 36336 - - - -
225 3 M29CEF 3N225 34143 M29CEP 3N225 34149 M29CED 3N225 34155
4 M29CEF 4N225 34197 - - - - 3SM29-630 35kA (N) 400 3 M29EEF 3N400 36340 - - M29EED 3N400 36346
250 3 M29CEF 3N250 34144 M29CEP 3N250 34150 M29CED 3N250 34156 4 M29EEF 4N400 36352 - - - -
4 M29CEF 4N250 34198 - - - - 500 3 M29EEF 3N500 36341 - - M29EED 3N500 36347
50kA (S) 125 3 M29CEF 3S125 34199 M29CEP 3S125 34205 M29CED 3S125 36229 4 M29EEF 4N500 36353 - - - -
4 M29CEF 4S125 36235 - - - - 630 3 M29EEF 3N630 36342 - - M29EED 3N630 36348
160 3 M29CEF 3S160 34200 M29CEP 3S160 34206 M29CED 3S160 36230 4 M29EEF 4N630 36354 - - - -
4 M29CEF 4S160 36236 - - - - 50kA (S) 400 3 M29EEF 3S400 36358 - - M29EED 3S400 36364
180 3 M29CEF 3S180 34201 M29CEP 3S180 34207 M29CED 3S180 36231 4 M29EEF 4S400 36370 - - - -
4 M29CEF 4S180 36237 - - - - 500 3 M29EEF 3S500 36359 - - M29EED 3S500 36365
200 3 M29CEF 3S200 34202 M29CEP 3S200 34208 M29CED 3S200 36232 4 M29EEF 4S500 36371 - - - -
4 M29CEF 4S200 36238 - - - - 630 3 M29EEF 3S630 36360 - - M29EED 3S630 36366
Power Distribution Electrics

Power Distribution Electrics


225 3 M29CEF 3S225 34203 M29CEP 3S225 34209 M29CED 3S225 36233 4 M29EEF 4S630 36372 - - - -
4 M29CEF 4S225 36239 - - - - 65kA (H) 400 3 M29EEF 3H400 36376 - - M29EED 3H400 36382
250 3 M29CTF 3S250 34204 M29CEP 3S250 34210 M29CED 3S250 36234 4 M29EEF 4H400 36388 - - - -
4 M29CEF 4S250 36240 - - - - 500 3 M29EEF 3H500 36377 - - M29EED 3H500 36383
65kA (H) 125 3 M29CEF 3H125 36241 M29CEP 3H125 36247 M29CED 3H125 36253 4 M29EEF 4H500 36389 - - - -
4 M29CEF 4H125 36259 - - - - 630 3 M29EEF 3H630 36378 - - M29EED 3H630 36384
160 3 M29CEF 3H160 36242 M29CEP 3H160 36248 M29CED 3H160 36254 4 M29EEF 4H630 36390 - - - -
4 M29CEF 4H160 36260 - - - - 100kA (X) 400 3 M29EEF 3X400 36418 - - M29EED 3X400 36424
180 3 M29CEF 3H180 36243 M29CEP 3H180 36249 M29CED 3H180 36255 4 M29EEF 4X400 36430 - - - -
4 M29CEF 4H180 36261 - - - - 500 3 M29EEF 3X500 36419 - - M29EED 3X500 36425
200 3 M29CEF 3H200 36244 M29CEP 3H200 36250 M29CED 3H200 36256 4 M29EEF 4X500 36431 - - - -
4 M29CEF 4H200 36262 - - - - 630 3 M29EEF 3X630 36420 - - M29EED 3X630 36426
225 3 M29CEF 3H225 36245 M29CEP 3H225 36251 M29CED 3H225 36257 4 M29EEF 4X630 36432 - - - -
4 M29CEF 4H225 36263 - - - -
250 3 M29CEF 3H250 36246 M29CEP 3H250 36252 M29CED 3H250 36258 3SM29-800 35kA (N) 400 3 M29FEF 3N400 36433 - - M29FTD 3N400 36438
4 M29CEF 4H250 36264 - - - - 4 M29FEF 4N400 36443 - - - -
100kA (X) 125 3 M29CEF 3X125 36265 M29CEP 3X125 36271 M29CED 3X125 36277 500 3 M29FEF 3N500 36434 - - M29FTD 3N500 36439
4 M29CEF 4X125 36283 - - - - 4 M29FEF 4N500 36444 - - - -
160 3 M29CEF 3X160 36266 M29CEP 3X160 36272 M29CED 3X160 36278 630 3 M29FEF 3N630 36435 - - M29FTD 3N630 36440
4 M29CEF 4X160 36284 - - - - 4 M29FEF 4N630 36445 - - - -
180 3 M29CEF 3X180 36267 M29CEP 3X180 36273 M29CED 3X180 36279 700 3 M29FEF 3N700 36436 - - M29FTD 3N700 36441
4 M29CEF 4X180 36285 - - - - 4 M29FEF 4N700 36446 - - - -
200 3 M29CEF 3X200 36268 M29CEP 3X200 36274 M29CED 3X200 36280 800 3 M29FEF 3N800 36437 - - M29FTD 3N800 36442
4 M29CEF 4X200 36286 - - - - 4 M29FEF 4N800 36447 - - - -
225 3 M29CEF 3X225 36269 M29CEP 3X225 36275 M29CED 3X225 36281 50kA (S) 400 3 M29FEF 3S400 36448 - - M29FTD 3S400 36453
4 M29CEF 4X225 36287 - - - - 4 M29FEF 4S400 36458 - - - -
250 3 M29CEF 3X250 36270 M29CEP 3X250 36276 M29CED 3X250 36282 500 3 M29FEF 3S500 36449 - - M29FED 3S500 36454
4 M29CEF 4X250 36288 - - - - 4 M29FEF 4S500 36459 - - - -
630 3 M29FEF 3S630 36450 - - M29FED 3S630 36455
3SM29-400 35kA (N) 250 3 M29DEF 3N250 36289 M29DEP 3N250 36293 M29DED 3N250 36297 4 M29FEF 4S630 36460 - - - -
4 M29DEF 4N250 36301 - - - - 700 3 M29FEF 3S700 36451 - - M29FED 3S700 36456
315 3 M29DEF 3N315 36290 M29DEP 3N315 36294 M29DED 3N315 36298 4 M29FEF 4S700 36461 - - - -
4 M29DEF 4N315 36302 - - - - 800 3 M29FEF 3S800 36452 - - M29FED 3S800 36457
350 3 M29DEF 3N350 36291 M29DEP 3N350 36295 M29DED 3N350 36299 4 M29FEF 4S800 36462 - - - -
4 M29DEF 4N350 36303 - - - -
400 3 M29DEF 3N400 36292 M29DEP 3N400 36296 M29DED 3N400 36300
4 M29DEF 4N400 36304 - - - -
50kA (S) 250 3 M29DEF 3S250 36305 M29DEP 3S250 36309 M29DED 3S250 36313
4 M29DEF 4S250 36317 - - - -
315 3 M29DEF 3S315 36306 M29DEP 3S315 36310 M29DED 3S315 36314
4 M29DEF 4S315 36318 - - - -
350 3 M29DEF 3S350 36307 M29DEP 3S350 36311 M29DED 3S350 36315
4 M29DEF 4S350 36319 - - - -
400 3 M29DEF 3S400 36308 M29DEP 3S400 36312 M29DED 3S400 36316
4 M29DEF 4S400 36320 - - - -

94 www.sassin.com www.sassin.com 95
Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Motor driven mechanism


Electronic Type
Breaking Rated Fixed type Plug in type Drawer type
capacity current(A) Poles Type code Order code Type code Order code Type code Order code Function
3SM29-800 65kA (H) 400 3 M29FEF 3H400 36463 - - M29FED 3H400 36468
- -
Used for opening and closing the circuit breaker remotely
4 M29FEF 4H400 36473 - -
500 3 M29FEF 3H500 36464 - - M29FED 3H500 36469
4 M29FEF 4H500 36474 - - - -
Technical specifications
630 3 M29FEF 3H630 36465 - - M29FED 3H630 36470
4 M29FEF 4H630 36475 - - - -
700 3 M29FEF 3H700 36466 - - M29FED 3H700 36471 Model type MD1 MD2 MD3
4 M29FEF 4H700 36476 - - - - 3SM29-250 3SM29-125 3SM29-630,3SM29-800
800 3 M29FEF 3H800 36467 - - M29FED 3H800 36472 Application
3SM29-400 3SM29-160 3SM29-1600
4 M29FEF 4H800 36477 - - - - Operating voltage range (85%-110%)Un
100kA (X) 400 3 M29FEF 3X400 36478 - - M29FED 3X400 36483 Rated control voltage 220Vac,380Vac,220Vdc,110Vdc 220Vac,380Vac,220Vdc,110Vdc 220Vac,380Vac,220Vdc,110Vdc
4 M29FEF 4X400 36488 - - - - Operating current (A) ≤2 ≤0.5 ≤7.5
500 3 M29FEF 3X500 36479 - - M29FED 3X500 36484 Start power consumption in 220/380Vac (VA) 510 220 660
4 M29FEF 4X500 36489 - - - - Continuance power consumption in 220/380Vac(VA) 360 110 110(180)
630 3 M29FEF 3X630 36480 - - M29FED 3X630 36485 Start power consumption in 110/220Vdc (W) 510 220 600
4 M29FEF 4X630 36490 - - - - Continuance power consumption in 110/220Vdc (W) 360 110 180
700 3 M29FEF 3X700 36481 - - M29FED 3X700 36486 Opening time (s) 0.1 0.1 0.1
4 M29FEF 4X700 36491 - - - - Closing time (s) 0.1 0.1 0.3
800 3 M29FEF 3X800 36482 - - M29FED 3X800 36487 Eletrical life(times) 4000 8000 3000
Power Distribution Electrics

Power Distribution Electrics


4 M29FEF 4X800 36492 - - - - Protection degree IP40

3SM29-1250 50kA (S) 800 3 M29GF 3S800 34289 - - M29GD 3S800 34298
4 - - - - - - Selection and ordering data
1000 3 M29GF 3S1000 34290 - - M29GD 3S1000 34299
4 - - - - - -
1250 3 M29GF 3S1250 34291 - - M29GD 3S1250 34300
4 - - - - - - Rated control
65kA (H) 800 3 M29GF 3H800 34292 - - M29GD 3H800 34301 Model Aplication voltage (VAC) Type code Ordercode
Order code
4 - - - - - -
- - MD2 Frame A 3SM29-125 220...240V AC M29A MM240A 10709
1000 3 M29GF 3H1000 34293 M29GD H1000 34302
4 - - - - - -
1250 3 M29GF 3H1250 34294 - - M29GD H1250 34303 380...415V AC M29A MM415A 32727
4 - - - - - -
80kA (G) 800 3 M29GF 3G800 34295 - - M29GD 3G800 34304 Frame B 3SM29-160 220...240V AC M29B MM240A 10719
4 - - - - - -
1000 3 M29GF 3G1000 34296 - - M29GD 3G1000 34305 380...415V AC M29B MM415A 32728
4 - - - - - -
1250 3 M29GF 3G1250 34297 - - M29GD 3G1250 34306
4 - - - - - -
MD1 Frame C 3M29-250 220...240V AC M29C MM240A 10729
3SM29-1600 50kA (S) 800 3 M29HF 3S800 34307 - - M29HD 3S800 34319
4 - - - - - -
380...415V AC M29C MM415A 32729
1000 3 M29HF 3S1000 34308 - - M29HD 3S1000 34320
4 - - - - - -
- - Frame D 3SM29-400 220...240V AC M29DMM240A 10739
1250 3 M29HF 3S1250 34309 M29HD 3S1250 34321
4 - - - - - -
1600 3 M29HF 3S1600 34310 - - M29HD 3S1600 34322 380...415V AC M29D MM415A 32730
4 - - - - - -
65kA (H) 800 3 M29HF 3H800 34311 - - M29HD 3H800 34323
4 - - - - - -
1000 3 M29HF 3H1000 34312 - - M29HD 3H1000 34324 MD3 Frame E/F 3SM29-630 ... 800 220...240V AC M29EF MM240A 10749
4 - - - - - -
1250 3 M29HF 3H1250 34313 - - M29HD 3H1250 34325 380...415V AC M29EF MM415A 32731
4 - - - - - -
1600 3 M29HF 3H1600 34314 - - M29HD 3H1600 34326
Frame G/H 3SM29-1250...1600 220...240V AC M29GH MM240A 10759
4 - - - - - -
80kA (G) 800 3 M29HF 3G800 34315 - - M29HD 3G800 34327
- - 380...415V AC M29GH MM415A 32732
4 - - - -
1000 3 M29HF 3G1000 34316 - - M29HD 3G1000 34328
4 - - - - - -
1250 3 M29HF 3G1250 34317 - - M29HD 3G1250 34329
4 - - - - - -
1600 3 M29HF 3G1600 34318 - - M29HD 3G1600 34330
4 - - - - - -

96 www.sassin.com www.sassin.com 97
Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Rotary handle operation mechanism Shunt release

Functions Function
Used for opening and closing the circuit breaker Used for opening the circuit breaker remotely
Used for rotating the circuit breaker, not pushing-pulling it upwards-downwards

Technical specifications
Technical specifications

Model type SR91 SR92 SR93


Model type CSS-1 CSS-2 A-1 A-2 F-1 F-2 Application 3SM29-125 3SM29-250 3SM29-630, 3SM29-800
3SM29-125 3SM29-250 3SM29-125 3SM29-630 3SM29-125 3SM29-630 3SM29-160 3SM29-400 3SM29-1600
3SM29-160 3SM29-400 3SM29-160 3SM29-800 3SM29-160 3SM29-800 Operating voltage range (70%-110%)Un
Application 3SM29-630 3SM29-250 3SM29-1600 3SM29-250 3SM29-1600 Rated control voltage 220Vac,380Vac,220Vdc,110Vdc 220Vac,380Vac,220Vdc,110Vdc 220Vac,380Vac,220Vdc,110Vdc
3SM29-800 3SM29-400 3SM29-400 Response time(ms) ≥20,≤60
3SM29-1600 Power consumption in 220/380Vac (VA) 150 150 150
Feature Extended round Extended rectangle Round rotary Round rotary Rectangle rotary Rectangle rotary Power consumption in 110/220Vdc (W) 150 150 150
rotary handle rotary handle handle handle handle handle
Protection degree IP30 IP30 IP30 IP30 IP30 IP30
Selection and ordering data

Selection and ordering data


Power Distribution Electrics

Power Distribution Electrics


Rated control
Model Aplication voltage Type code Order
Ordercode
code
Operation Rotary Without interlock With interlock
SR91 Frame A/B 3SM29-125...160 220...240V AC M29AB SH240A 10701
Installation device handle Aplication Type code Order code Type code Order code
In breaker RHM2 Frame A 3SM29-125 - - - -
380...415V AC M29AB SH415A 10702
Frame B 3SM29-160 - - - -
Frame C 3SM29-250 M29C RHM2 10750 M29C RHM2L 10711 110V DC M29AB SH110D 32733
Frame D 3SM29-400 M29DE RHM2 10755 M29DE RHM2L 10712
Frame E/F 3SM29-630…800 M29EF RHM2 10756 M29EF RHM2L 10713 220V DC M29AB SH220D 32734
Frame G/H 3SM29-1250…1600 M29GH RHM2 10760 M29GH RHM2L 10714

SR92 Frame C/D 3SM29-250...400 220...240V AC M29CD SH240A 10721


RHM1 A type, round Frame A 3SM29-125 - - - -
In switch box's door
short handle Frame B 3SM29-160 - - - - 380...415V AC M29CD SH415A 10722
central type
Frame C 3SM29-250 M29C RHM1AS 10731 M29C RHM1ASL 10751
Frame D 10732 10752 110V DC M29CD SH110D 32735
3SM29-400 M29D RHM1AS M29D RHM1ASL
A type, square Frame E/F 3SM29-630…800 M29EF RHM1AL 10733 M29EF RHM1ALL 10753
220V DC M29CD SH220D 32736
long handle Frame G/H 3SM29-1250…1600 M29GH RHM1AL 10734 M29GH RHM1ALL 10754

B type, square Frame A 3SM29-125 - - - -


short handle Frame B 3SM29-160 - - - - SR93 Frame E/F/G/H 3SM29-630...1600 220...240V AC M29FEGH SH240A 10741
Frame C 3SM29-250 M29C RHM1BS 32745 M29C RHM1BSL 32749
Frame D 3SM29-400 M29DRHM1BS 32746 M29D RHM1BSL 32750 380...415V AC M29FEGH SH415A 10742
B type, square Frame E/F 3SM29-630…800 M29EF RHM1BL 32747 M29EF RHM1BLL 32751
long handle Frame G/H 3SM29-1250…1600 M29GH RHM1BL 32748 M29GH RHM1BLL 32752 110V DC M29FEGH SH110D 32737

RHM3 A type, square Frame A 3SM29-125 M29A RHM3AS 32753 M29A RHM3ASL 10730 220V DC M29FEGH SH220D 32738
eccentricity short handle Frame B 3SM29-160 M29B RHM3AS 32754 M29B RHM3ASL 10736
Frame C 3SM29-250 M29C RHM3AS 32755 M29C RHM3ASL 33040
Frame D 3SM29-400 M29D RHM3AS 32756 M29D RHM3ASL 33041
A type, square Frame E/F 3SM29-630…800 M29EF RHM3AL 10710 M29EF RHM3ALL 33042
long handle Frame G/H 3SM29-1250…1600 M29GH RHM3AL 10720 M29GH RHM3ALL 33043

B type, square Frame A 3SM29-125 M29A RHM3BS 33044 M29A RHM3BSL 33050
short handle Frame B 3SM29-160 M29B RHM3BS 33045 M29B RHM3BSL 33051
Frame C 3SM29-250 M29C RHM3BS 33046 M29C RHM3BSL 33052
Frame D 3SM29-400 M29D RHM3BS 33047 M29D RHM3BSL 33053
B type, square Frame E/F 3SM29-630…800 M29EF RHM3BL 33048 M29EF RHM3BLL 33054
long handle Frame G/H 3SM29-1250…1600 M29GH RHM3BL 33049 M29GH RHM3BLL 33055

98 www.sassin.com www.sassin.com 99
Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Under-voltage release Auxiliary contact and alarm contact

Function Functions

Used for opening the circuit breaker when energy cuts off or voltage goes below 70% of the operating voltage Indication of contacting status
Used for supplying electrical signal of the circuit breaker according to the operating position

Technical specifications

Model type UR91 UR92 UR93 Selection and ordering data


Application 3SM29-125, 3SM29-160 3SM29-250, 3SM29-400 3SM29-630, 3SM29-800, 3SM29-1600
Action voltage range (35%-70%)Ue
Guarantee close voltage range (85%-110%)Ue
Contact
Guarantee no-close voltage range ≤35%Ue
Aplication Function position Type code Order code
Rated control voltage (V) 220Vac,380Vac,220Vdc,110Vdc 220Vac,380Vac,220Vdc,110Vdc 220Vac,380Vac,220Vdc,110Vdc
Response time(ms) ≥20, ≤60 Frame A/B 3SM29-125...160 Auxiliary contact 1NO+1NC M29AB AC11 10705
Power consumption in 220/380Vac (VA) 10 10 10
Power consumption in 110/220Vdc (W) 4 4 4

Auxiliary contact 1NO+1NC+1W M29AB CW11 10726


Selection and ordering data
+ alarm contact
Power Distribution Electrics

Power Distribution Electrics


Rated control
Model Aplication voltage Type code Order
Ordercode
code
Frame C/D 3SM29-250...400 Auxiliary contact 1NO+1NC M29CD AC11 10706
UR91 Frame A/B 3SM29-125...160 220...240V AC M29AB UV240A 10703

2NO+2NC M29CD AC22 10715


380...415V AC M29AB UV415A 10704

Auxiliary contact 1NO+1NC+1W M29CD CW11 10735


110V DC M29AB UV110D 32739
+ alarm contact
2NO+2NC+1W M29CD CW22 10740
220V DC M29AB UV220D 32740

Frame E/F/G/H 3SM29-630...1600 Auxiliary contact 1NO+1NC M29EFGH AC11 10716


UR92 Frame C/D 3SM29-250...400 220...240V AC M29CDUV240A 10723

2NO+2NC M29EFGH AC22 10725


380...415V AC M29CD UV415A 10724

Auxiliary contact 1NO+1NC+1W M29EFGH CW11 10745


110V DC M29CD UV110D 32741
+ alarm contact
2NO+2NC+1W M29EFGH CW22 10746
220V DC M29CD UV220D 32742

UR93 Frame E/F/G/H 3SM29-630...1600 220...240V AC M29EFGH UV240A 10743

380...415V AC M29EFGH UV415A 10744

110V DC M29EFGH UV110D 32743

220V DC M29EFGH UV220D 32744

100 www.sassin.com www.sassin.com 101


Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Accessaries introduction Protection characteristic

Variable parameters of thermal overload protection current setting


Accessory code Accessory installation and lead cable method Characteristics of thermal magnetic over-current release
Characteristics of inverse time delay thermal releasing-ranges of current settings of thermal inverse time delay
Name of accessories 3SM29-125 3SM29-250 3SM29-630 3SM29-1250
Thermal magnetic Duplex 3SM29-160 3SM29-400 3SM29-800 3SM29-1600
release release
Current settings
3P、4P 3P、4P 3P、4P 3P Frame Adjustable
of inverse time delay
rated Circumstance temperature instantaneous current Instantaneous
current 40℃ Setting IRl (A)
Alarm Contact 208 308 Rated current releasing In
size
current
Im(A)
+10℃ +20℃ +30℃ +40℃ +50℃ +60℃ A/B/C phase N pole 5In 7.5In 10In
Shunt release 210 310
12.5A 12.5A 12.5A - - - 500A -
16A 16A 16A - - - 500A 10
Shunt Release
218 318 20A 20A 20A - - - 500A 10
Alarm Contact
25A 25A 25A - - - 500A 10
Auxiliary Contact 220 320 32A 32A 32A - - - 500A 10
125 1.19 1.03 1.06 1.0In 0.93 0.87
40A 40A 40A - - - 500A 10
Power Distribution Electrics

Power Distribution Electrics


50A 50A 50A - - - 500A 10
Auxiliary Contact
228 328 63A 63A 63A - - - 630A 12
Alarm Contact
80A 80A 80A - - - 800A 12

Under voltage release 100A 100A 100A - - - 1000A 12


230 330
125A 125A 125A - - - 1250A 12
32A 22.4 ~32A 22.4 ~32A - - - 500A 10
Under voltage release
238 338 40A 28~40A 28~40A - - - 500A 10
Alarm Contact
50A 35 ~50A 35 ~50A - - - 500A 10
Shunt release 63A 44.1 ~63A 44.1 ~63A - - - 630A 12
240 340 160 1.15 1.10 1.05 1.0In 0.94 0.88
Auxiliary Contact
80A 56 ~80A 56 ~80A - - - 800A 12
Shunt Release 100A 70 ~100A 70 ~100A - - - 1000A 12
Under voltage release 248 348 125A 87.5 ~125A 87.5 ~125A - - - 1250A 12
Two-sets Auxiliary Contact
160A 112 ~160A 112 ~160A - - - 1600A 12
Two-sets Auxiliary Contact 260 360 125A 87.5 ~125A 87.5 ~125A - - - 1250A 12
160A 112 ~160A 112 ~160A - - - 1600A 12
Two-sets Auxiliary Contact 180A 126 ~180A 126 ~180A - - - 1800A 12
268 368
Alarm Contact 250 1.14 1.10 1.05 1.0In 0.95 0.87 200A 140 ~200A 140 ~200A - - - 2000A 12
225A 157.5 ~225A 157.5 ~225A - - - 2250A 12
Under voltage release
270 370 250A 175 ~225A 175 ~225A - - - 2500A 12
Auxiliary Contact
250A 175 ~250A 175 ~250A 1250 1875 2500 2500A 12
Under voltage release 315A 220.5 ~315A 220.5 ~315A 1575 2363 3150 3150A 12
Auxiliary Contact 278 378 400 1.13 1.11 1.04 1.0In 0.92 0.85
Alarm Contact 350A 245 ~350A 245 ~350A 1750 2625 3500 3500A 12
400A 280 ~400A 280 ~400A 1750 2625 4000 4000A 12
Attention: Alarm Contact
handle Two-sets Auxiliary Contact Shunt release 400A 400A 400A - - - 4000A -
500A 500A 500A - - - 5000A -
left installation right installation Lead cable direction 630
Auxiliary Contact Under voltage release 1.10 1.08 1.03 1.0In 0.84 0.77 630A 630A 630A - - - 6300A -
800
700A 700A 700A - - - 7000A -
800A 800A 800A - - - 8000A -
800A 800A 800A - - - - -
1250 1000A 1000A 1000A - - - - -
1.08 1.06 1.02 1.0In 0.8 0.73
1600 1250A 1250A 1250A - - - - -
1600A 1600A 1600A - - - - -

102 www.sassin.com www.sassin.com 103


Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Tripping curve Microprocessor control panel

3SM29-125 3SM29-160 ST110-M(ST110-M/F) Microprocessor electronic release panel


180 180

100 100

50 50

minute
minute

Load Against overload Ir1


10 10 indication
5 5
Earth fault current
1 1 Ir4 switch
40 40
action time

action time
20 20

10 10
6 6
4 4 ST110-M Intelligentized Electronic Release
second

2 2

second
1 1
0.6 0.6 Ir1
0.4 0.4
OFF F 0.7 OFF
0.2 0.2 60% 100%
0.4 R 0.8 0.2
0.1 0.1
0.06 0.06 0.5 B 0.9 0.4
0.04 0.04
0.6 M 1.0 1.0 F R B M 12ln
0.02 0.02
0.7 2ln 5ln 10ln
0.01 0.01 test CURVE
15 20 30 40 50 70 100 15 20 30 40 50 70 100 0.8
Power Distribution Electrics

2 3 4 5 6 7 8 10 2 3 4 5 6 7 8 10

Power Distribution Electrics


1 1.5 1 1.5
current(multiple of commutating current ) current(multiple of commutating current ) alarm 0.9 0
1.0

3SM29-250 3SM29-400
Malfunction
180 180
indication Overload pre-warning
current Ip
100 100
Curve designation
50 50
minute

minute

Power supply&
10 10 Test socket self-diagnose
5 5
indication Curve selection
Ir2,Ir3 switch
1 1
40 40
action time

action time

20 20

10 10
6 6
4 4
2 2
second

second

1 1 ST110-H(ST110-H/F) Microprocessor electronic release's panel


0.6 0.6
0.4 0.4

0.2 0.2

0.1 0.1
0.06 0.06
0.04 0.04
Load
0.02 0.02
indication
0.01 0.01
1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 70 100 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 70 100

current(multiple of commutating current ) current(multiple of commutating current )

3SM29-630 3SM29-800
180 180
Ir1

100 100
60% 100%
minute

50 50
minute

10 10

5 5

test alarm
1 1
40 40
action time

20 20
action time

10 10 Power supply &


6
4
6
4
self-diagnose RS485 COM port
2 2 indication
Test socket
second

second

1 1
0.6 0.6
0.4 0.4 Malfunction
0.2 0.2 warning
0.1 0.1 indication
0.06 0.06
0.04 0.04
0.02 0.02
0.01 0.01
1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 70 100 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 70 100

current(multiple of commutating current ) current(multiple of commutating current )

104 www.sassin.com www.sassin.com 105


Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Releasing curve Protective performance of circuit breaker's residual current release for motor protection:

No. Test current type I/In Engaged time endurance Start state
Microprocessor electronic release main function
1 Engaged non-release current 1.0 >2h Cold state
Main function of microprocessor electronic release 1.2 ≤2h

Main circuit load indication The LED in panel indicates 60%、80%、90%、100%. ≤2min (In≤200A) Hot
1.5
2 Engaged release current ≤4min (200A<In≤400A)
Power supply indication The LED in panel indicates
Self-diagnose indication The LED in panel indicates 2s<Tp≤10s (In≤200A)
7.2 Cold
4s<Tp≤10s (200A<In≤400A)
Overload pre-warning indication The LED in panel indicates
Earth fault indication The LED in panel indicates
Thermal memory Record over-load cumulate caloric effect
Basis on different purpose ,user can choose short-circuit Outline and installation dimensions
Fast set protection character curve
release's character (curve F、R、B、M)
Overload pre-warning
Signal output of the transition ray contact releasing alarm
Installation type: Fixed, Plug-in, Withdrawable type
between breaker and ST-200 Intelligentized
Earth fault alarm
control module
Signal of breaker's on/ off Installation
Releasing test Test socket Plug in
Frame rated current Fixed Withdrawable
Switch commutating 3p 4p 3p 4p 3p 4p
Power Distribution Electrics

Power Distribution Electrics


Setting panel parameter Switch commutating
125A
User can reset the protection character Switch commutating 160A
when the main circuit with or without power running Switch commutating 250A
Switch commutating 400A
630A
800A
Electronic release protection character curve 1250A
1600A

2000 2000

1000
lr1=(0.4-1)Xln
1000
lr1=(0.4-1)Xln
Breaker’s installation dimensions
500 500

200 200

100 100
t=10S
l tl = 1 0 S
Fixed type 3SM29-125~160
50 50
lr2=1.5lr1
Connect wire in front of board
20 20
Ts=0.4S
10 10

5
lr2=5lr1
5
lr2=1.5lr1
Y
T(S) T(S)
W1(4P) H3
2 2 H2
W2(3P) ≥3 H1 Φ Φ
lr4=(0.2~1)Xln lr2=10lr1 lr4=(0.2~1)Xln lr2=5lr1 lr2=10lr1
1 for four pole 1 for four pole
H

0.5 0.5

0.2 0.2
t=0.4S F-Curve B-Curve B-Curve
6
R-Curve M-Curve t6=0.4S F-Curve R-Curve M-Curve

L5
0.1 lr3=2ln lr3=5ln lr3=10ln lr3=12ln
0.1
lr3=2ln lr3=5ln lr3=10ln lr3=12ln

0.05 0.05

L4
L1

L3
0.02 0.02
X X

L6
0.01 0.01
0.2 0.3 0.4 0.5 0.6 0.8 1 2 3 4 5 6 8 10 20 25 0.2 0.3 0.4 0.5 0.6 0.8 1 2 3 4 5 6 8 10 20 25

L2
XIn XIn

D D D D D
H4
Protection performance of residual current release
Y
Protection performance of circuit breaker's residual current release for power distribution:

No. Test current type I/In Engaged time endurance Start state
Engaged 2h(In>63A)
1 1.05 Cold
non-release current 1h(In≤63A)
Type D L1 L2 L3 L4 L5 L6 W1 W2 H H1 H2 H3 H4 Φ
Engaged release 2h(In>63A)
2 1.30 Hot 3SM29-125 25 120 48
current 1h(In≤63A) 102 45 62 100 101 76 25.5 67.5 70 91 75.5 4.5
3SM29-160 30 120 48 102 45 62 100 120 90 27.5 68.5 71 93 76.5 4.5

106 www.sassin.com www.sassin.com 107


Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Fixed type 3SM29-250~1600 Fixed type 3SM29-125-800


Connect wire in front of board Connect wire behind board
Y
W1(4P) H3 L6
H2 L5 Φ
W2(3P) ≥3 H1 Φ Φ
H

L4
L5
X

L2

L3
L1

L4
L3
X X X

L6

L1
D D
D D D D D D D D D
H4

Y
Power Distribution Electrics

Power Distribution Electrics


Type D L1 L2 L3 L4 L5 L6 W1 W2 H H1 H2 H3 H4 Φ L7 Φ1 Type D L1 L2 L3 L4 L5 L6 Φ1
3SM29-250 35 170 87.25 206 105 73.75 139 140 105 25 101.5 103.5 135 113 5.5 10.8 8.5 3SM29-125 25 50 124 102 39 43 76 18
3SM29X-250 35 255 87.25 278.5 105 154.5 224 140 105 25 101.5 103.5 135 113 5.5 10.8 8.5 3SM29-160 30 50 124 102 39 43 76 18
3SM29-400 43.75 254 125.25 281 105 107.25 214 183.75 140 25 101.5 103.5 135 113 5.5 12 14 3SM29-250 35 85.25 175 145 73.75 55 105 24
3SM29-630 70 268 142.75 241 105 109.25 375 280 210 23 101.5 103.5 167.5 115 5.5 10.0 11 3SM29X-250 35 85.25 255 224 123.5 55 105 24
3SM29-800 70 268 142.75 241 105 109.25 237 280 210 23 101.5 103.5 167.5 115 5.5 10.0 11 3SM29-400 43.75 131.25 259 218 107.25 55 105 30
3SM29X-800 70 406 142.75 479 105 256.5 375 280 210 23 101.5 103.5 167.5 115 3SM29-630 70 145.25 273 241 117.25 55 74.5 50
5.5 10.0 11
– 3SM29-800 70 145.25 273 241 117.25 55 74.5 50
3SM29-1600 70 406 189 513 105 203 378 210 39 137 138.5 204.5 152 5.5 13.5 11

Fixed type 3SM29-1600


Connect wire in front of board
Y
85 204.5
210
Y
(3POL) 138.5
≥3
70 70
70 70 70

217

203

171.5
171.5
406

378

315
315
X X

105
35

R40

Φ5
105 70 70 70

Y Y

108 www.sassin.com www.sassin.com 109


Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Plug-in version 3SM29-125-160 Plug-in version 3SM29-125-400


Connect wire in front of board Connect wire in front of board

Y 3D
D D D H1 Y
D D D H4 H4 2D
R
H3

L3

L5
L2

L3
L2
X X X X

L4

L6
L4
L1
L1

H2 D D
Y H2 D D Y
Power Distribution Electrics

Power Distribution Electrics


Type D L1 L2 L3 L4 H1 H2 Type D L1 L2 L3 L4 L5 L6 H1 H2 H3 H4
3SM29-125 25 70 163 84 144 123 52 3SM29-125 25 70 163 102 39 84 144 123 52 50 80
3SM29-160 30 70 163 84 144 123 52 3SM29-160 30 70 163 102 39 84 144 123 52 50 80
3SM29-250 35 85.25 175 143 69.2 52.5 100 184.5 83 52 96
3SM29-400 43.75 131.25 259 218 110.75 107.25 218 184.5 83 55 100

Plug-in version 3SM29-250-400


Connect wire in front of board
Draw-out version 3SM29-250~400
W1( 4P )
W2 Connect wire in front of board
W3 W3 W3 ≥3 31
L5

Ф W4(4P)
31 ≥3
Y Y W2(4P)

W3(3P)
Y
L3

L1

L7
L4

L2

L3

L1
L6

X X

L8
L7
L6

L4
L5

L2
X X

H1 Y W6
Ф
H2
L5

H1 Φ
W4
H2 W1

Y Y

Type L1 L2 L3 L4 L5 L6 L7 W1 W2 W3 W4 W6 H1 H2 Ф
3SM29-250 89.7 175 107.25 210 10 52.25 100 140 105 35 105 25 153 184.5 5
Type L1 L2 L3 L4 L5 L6 L7 L8 L9 W1 W2 W3 W4 W5 H1 H2 Φ
3SM29- 400 127.75 259 150.75 305 14 65.75 135 183.75 140 43.75 160 58 153 184.5 6
3SM29-250 89.75 175 107.25 210 1.75 105 52.25 100 - 84 105 70 25 - 167 190 5
3SM29-400 127.75 259 150.75 305 1.75 105 65.75 135 - 101.5 160 115 58 - 167 190 6

110 www.sassin.com www.sassin.com 111


Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM29 Series 3SM29

Draw-out version 3SM29-630~1600 Plug-in version 3SM29-630/800


Connect wire in front of board Connect wire behind board

Y ≥3 31
Φ W2(4P) 280
(4P)
Y
L6

Φ 210 140 (3P)


W3(3P) 80.5 (3P)
Y 70 70 70 210 (4P)
≥3 70

77.5
L3

L1
L4

122
133
89.5
L8

140
14.5

58

57.5
L2

45.5
L7
X X X X X

145 max

120
208

273
295

86.5
Φ8.5(M8)
4

77.5
107
214 (3P)
H1 167 123.5 136.5
W4 284
H2 190 (4P)
L6

W5 W1
193.5
Y
Y
Power Distribution Electrics

Power Distribution Electrics


Type L1 L2 L3 L4 L5 L6 L7 L8 L9 W1 W2 W3 W4 W5 H1 H2 Φ
3SM29-630 133 295 158 345 14.5 140 45.5 120 20 136.5 210 210 140 193.5 167 190 8.5
Plug-in version 3SM29-1600
3SM29-800 133 295 158 345 14.5 140 45.5 120 20 136.5 210 210 140 193.5 167 190 8.5 Connect wire behind board
3SM29-1600 211.25 406 268.25 520 8.25 140 68.25 120 – 136.5 – 210 140 193.5 218.5 241.5 8.5
Y Y
140
210 (3P)
108 (3P)
140
Draw-out version ≥3
Connect wire in front of board

120.5
211.25
143.25
145

92.5
≥3 31
Y

68.25
140
Φ W2(4P)

8.25
L6

Φ
X

270

406
X

120
W3(3P)
Y Φ8.5(M8)

76
160
4

120.5
L3

L1
L4

L8

123.5 136.5
L2

107
L7

218.5
X X X 241.5 214 (3P)
Y

H1
W4
H2
L6

W5 W1

Type L1 L2 L3 L4 L5 L6 L7 L8 W1 W2 W3 W4 W5 H1 H2 H3 H4 Φ
3SM29-250 175 87.75 143 73.75 1.75 105 52.25 100 84 105 70 70 105 167 190 52 96 5
3SM29-400 259 127.75 218 107.25 1.75 105 65.75 135 101.5 160 115 87.5 131.25 167 190 55 100 6

112 www.sassin.com www.sassin.com 113


Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM8N Series 3SM8N

Overview Applications and functions

Incoming and outgoing function in distribution systems


Switching and protection devices for motors,
transformers and capacitors
Disconnect or units with features for stopping and
switching off in an emergency mechanisms and terminal
covers in conjunction with likeable rotary operating
Available in the following versions
Power protection: the overload and short-circuit releases
are designed for the protection of cables, leads and
non-motor loads
Motor protection: the overload and short-circuit releases
are designed for optimized protection and direct-on-line
3
starting of induction squirrel-cage motors . The circuit
breakers for motor protection are susceptible to phase
Power Distribution Electrics

failure and feature an adjustable trip class

Power Distribution Electrics


1
2 7
6 Instruction of type code
5
4
M8N A 3 P 400 L
Instruction of external structure
Breaking capacity
L: Standard breaking capacity
M: Middle breaking capacity
H: High breaking capacity
11
Rated current(A)
10 10, 16, 20, 25, 32, 40, 50, 63 (Frame A)
9 16, 20, 25, 32, 40, 50, 63, 80, 100 (Frame B)
8
100, 125, 160, 180, 200, 225 (Frame C) 1
225, 250, 315, 350, 400 (Frame D)
400, 500, 630 (Frame E)
630, 700, 800 (Frame F) 2
3 6
Protection type
P: Power protection 7
M: Motor protection 8
4
Poles(P): 3: 3P; 4: 4P 5
Frame
A: 3SM8N-63; B: 3SM8N-100; C: 3SM8N-225
D: 3SM8N-400; E: 3SM8N-630; F:3SM8N-800
Series code

3SM8N series product overview There is no frame E and F for motor protection.
1 Body Only M type (medium breaking capacity type) has 4 poles: 1.SASSIN logo 5.Test button
4A: N-pole fixed without over-current release unit, it 2.Type 6.Working condition indicator
2 Plug-in connection 7 Under-voltage release
has been connected all along, and does not act 3.Technical data 7.Rated current
3 Rear panel connection 8 Rotary handle operating mechanism
with other three poles to turn on or off. 4.Standard 8.Certificate
4 Auxiliary contact 9 Rotary handle operating mechanism 4B: N-pole fixed without over-current release unit, it
5 Alarm contact 10 Electromagnetic operating mechanism acts with other three poles.

Electric motor operating mechanism 4C: N-pole fixed with over-current release unit, it acts
6 Shunt release 11
with other three poles.
4D: N-pole fixed with over-current release unit, it has
been connected all along, and does not act with
other three poles to turn on or off.

114 www.sassin.com www.sassin.com 115


Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM8N Series 3SM8N

Technical Specifications: Selection and ordering data

Type 3SM8N-63 3SM8N-100 3SM8N-225 3SM8N-400 3SM8N-630 3SM8N-800 Breaking capacity Rated current Number of Power distribution Motor protection
at 400V AC In(A) Poles Type code Order code Type code Order code
Standards IEC60947-2 IEC60947-2 IEC60947-2 IEC60947-2 IEC60947-2 IEC60947-2
Frame A For 4 poles, please complete the code by adding N-pole code.
IEC60947-4-1 IEC60947-4-1 IEC60947-4-1 IEC60947-4-1 IEC60947-4-1 IEC60947-4-1
3SM8N-63 16 3 M8NA 3P16L 25016 M8NA 3M16L 10139
Approval CE CE CE CE CE CE
20 3 M8NA 3P20L 25017 M8NA 3M20L 10140
Frame type A B C D E F 25 3 M8NA 3P25L 25018 M8NA 3M25L 10141
Class of breaking capacity L M L M H L M H L M H L M H M H 32 3 M8NA 3P32L 25019 M8NA 3M32L 10142
L
40 3 M8NA 3P40L 25020 M8NA 3M40L 10143
Number of poles 3 3,4 3 3,4 3 3 3,4 3 3 3,4 3 3 3,4 3 3 3
25kA 50 3 M8NA 3P50L 25021 M8NA 3M50L 10144
Frame Current Inm (A) 63 100 225 400 630 800
63 3 M8NA 3P63L 25022 M8NA 3M63L 10145
Rated current In(A) 10,16,20,25, 16,20,25,32 100,125,160 225,250,315 400,500 630,700
16 3 M8NA 3P16M 25025 M8NA 3M16M 10148
32,40,50,63 40,50,63,80,100 180,200,225 350,400 630 800 4 M8NA 4*P16M 25034* M8NA 4*M16M 10157*
Rated insulating voltage Ui (V) 500 800 800 800 800 800 20 3 M8NA 3P20M 25026 M8NA 3M20M 10149
4 M8NA 4 * P20M 25035* M8NA 4*M20M 10158*
Rated operating voltage, Ue (V) 400 400 690 400 400 690 400 400 690 400 400 690 400 690 400
M 25 3 M8NA 3P25M 25027 M8NA 3M25M 10150
Rated frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60
50kA 4 M8NA 4 * P25M 25036* M8NA 4*M25M 10159*
Rated impulsed withstand voltage, Uimp(kV) 6 8 8 8 8 8 32 3 M8NA 3P32M 25028 M8NA 3M32M 10151
Power Distribution Electrics

Power Distribution Electrics


Rated ultimate short- (AC) 50-60Hz400VO-CO (kA) 25 50 35 50 85 35 50 85 50 65 100 50 65 100 65 100 4 M8NA 4 * P32M 25037* M8NA 4*M32M 10160*

- 40 3 M8NA 3P40M 25029 M8NA 3M40M 10152


circuit breaking capacity, Icu (AC) 50-60Hz690VO-CO (kA) - - - 20 - 20 - 20 - - 20 - 20
4 M8NA 4 * P40M 25038* M8NA 4*M40M 10161*
Rated operating short- (AC) 50-60Hz400VO-CO-CO(kA) 18 35 22 35 50 22 35 50 35 42 65 35 42 65 42 65
50 3 M8NA 3P50M 25030 M8NA 3M50M 10153
circuit breaking capacity,Ics (AC) 50-60Hz690VO-CO-CO(kA) - - - 10 - - 16 - - 10 - - 10 - 15 - 4 M8NA 4 * P50M 25039* M8NA 4*M50M 10162*
Mechanical life (times) 8000 8000 8000 7500 7500 7500 63 3 M8NA 3P63M 25031 M8NA 3M63M 10154
4 M8NA 4 * P63M 25040* M8NA 4*M63M 10163*
Electrical life (times.) 1500 1500 1000 1000 1000 500
Frame B
Flashover distance (mm) ≤50 ≤50 ≤50 ≤50 ≤100 ≤100
3SM8N-100 16 3 M8NB 3P016L 25041 M8NB 3M016L 10164
Thermal magnetic release █ █ █ █ █ █ 20 3 M8NB 3P020L 25042 M8NB 3M020L 10165
Electronic release - - - - - - 25 3 M8NB 3P025L 25043 M8NB 3M025L 10166

A A A A A A 32 3 M8NB 3P032L 25044 M8NB 3M032L 10167


Utilization category (IEC60947-2)
L
40 3 M8NB 3P040L 25045 M8NB 3M040L 10168
Under-voltage release █ █ █ █ █ █ 35kA 50 3 M8NB 3P050L 25046 M8NB 3M050L 10169
Shunt-release █ █ █ █ █ █ 63 3 M8NB 3P063L 25047 M8NB 3M063L 10170
Auxiliary contact █ █ █ █ █ █ 80 3 M8NB 3P080L 25048 M8NB 3M080L 10171
█ █ █ █ █ █ 100 3 M8NB 3P100L 25049 M8NB 3M100L 10172
Alarm Contact

Weight - - - - - - 16 3 M8NB 3P16M 25050 M8NB 3M16M 10173


4 M8NB 4 * P16M 25059* M8NB 4*M16M 10182*
Ambient temperature -5 to +40℃, max. 95 % humidity
20 3 M8NB 3P20M 25051 M8NB 3M20M 10174
Storage temperature -40 to +75℃ 4 M8NB 4 * P20M 25060* M8NB 4*M20M 10183*
Altitude( Max) 2000 25 3 M8NB 3P25M 25052 M8NB 3M25M 10175
4 M8NB 4 * P25M 25061* M8NB 4*M25M 10184*
32 3 M8NB 3P32M 25053 M8NB 3M32M 10176
4 M8NB 4 * P32M 25062* M8NB 4*M32M 10185*
M 40 3 M8NB 3P40M 25054 M8NB 3M40M 10177
50kA 4 M8NB 4 * P40M 25063* M8NB 4*M40M 10186*
50 3 M8NB 3P50M 25055 M8NB 3M50M 10178
4 M8NB 4 * P50M 25064* M8NB 4*M50M 10187*
63 3 M8NB 3P63M 25056 M8NB 3M63M 10179
4 M8NB 4 * P63M 25065* M8NB 4*M63M 10188*
80 3 M8NB 3P80M 25057 M8NB 3M8N0M 10180
4 M8NB 4 * P80M 25066* M8NB 4*M8N0M 10189*
100 3 M8NB 3P100M 25058 M8NB 3M100M 10181
4 M8NB 4 * P100M 25067* M8NB 4*M100M 10190*

116 www.sassin.com www.sassin.com 117


Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM8N Series 3SM8N

Breaking capacity Rated current Number of Power distribution Motor protection Breaking capacity Rated current Number of Power distribution Motor protection
at 400V AC In(A) Poles Type code Order code Type code Order code at 400V AC In(A) Poles Type code Order code Type code Order code
Frame B For 4 poles, please complete the code by adding N-pole code. Frame D For 4 poles, please complete the code by adding N-pole code.

3SM8N-100 H 16 3 M8NB 3P016H 25068 M8NB 3M016H 10191 3SM8N-400 H 225 3 M8ND 3P225H 25116 M8ND 3M225H 10239
85kA 20 3 M8NB 3P020H 25069 M8NB 3M020H 10192 100kA 250 3 M8ND 3P250H 25117 M8ND 3M250H 10240
25 3 M8NB 3P025H 25070 M8NB 3M025H 10193 315 3 M8ND 3P315H 25118 M8ND 3M315H 10241
32 3 M8NB 3P032H 25071 M8NB 3M032H 10194 350 3 M8ND 3P350H 25119 M8ND 3M350H 10242
40 3 M8NB 3P040H 25072 M8NB 3M040H 10195 400 3 M8ND 3P400H 25120 M8ND 3M400H 10243
50 3 M8NB 3P050H 25073 M8NB 3M050H 10196 Frame E
63 3 M8NB 3P063H 25074 M8NB 3M063H 10197 3SM8N-630 L 400 3 M8NE 3P400L 25121 - -
80 3 M8NB 3P080H 25075 M8NB 3M080H 10198 50kA 500 3 M8NE 3P500L 25122 - -
100 3 M8NB 3P100H 25076 M8NB 3M100H 10199 630 3 M8NE 3P630L 25123 - -
Frame C 3 M8NE 3P400M 25124 -
M 400 -
3SM8N-225 L 100 3 M8NC 3P100L 25077 M8NC 3M100L 10200 4 M8NE 4 * P400M 25127* - -
65kA
35kA 125 3 M8NC 3P125L 25078 M8NC 3M125L 10201 500 3 M8NE 3P500M 25125 - -
160 3 M8NC 3P160L 25079 M8NC 3M160L 10202 4 M8NE 4 * P500M 25128* - -
180 3 M8NC 3P180L 25080 M8NC 3M180L 10203 630 3 M8NE 3P630M 25126 - -
200 3 M8NC 3P200L 25081 M8NC 3M200L 10204 4 M8NE 4 * P630M 25129* - -
225 3 M8NC 3P225L 25082 M8NC 3M225L 10205
H 400 3 M8NE 3P400H 25130 - -
M 100 3 M8NC 3P100M 25083 M8NC 3M100M 10206
Power Distribution Electrics

500 3 M8NE 3P500H 25131 -

Power Distribution Electrics


100kA -
50kA 4 M8NC 4 * P100M 25089* M8NC 4 * M100M 10212* 630 3 M8NE 3P630H 25132 - -
125 3 M8NC 3P125M 25084 M8NC 3M125M 10207 Frame F
4 M8NC 4 * P125M 25090* M8NC 4 * M125M 10213* 3 M8NF 3P630M 25133 -
3SM8N-800 M 630 -
160 3 M8NC 3P160M 25085 M8NC 3M160M 10208 4 M8NF 4 * P630M 25136* - -
65kA
4 M8NC 4 * P160M 25091* M8NC 4 * M160M 10214* 3 M8NF 3P700M 25134 -
700 -
180 3 M8NC 3P180M 25086 M8NC 3M180M 10209 4 M8NF 4 * P700M 25137* - -
4 M8NC 4 * P180M 25092* M8NC 4 * M180M 10215* 800 3 M8NF 3P800M 25135 - -
200 3 M8NC 3P200M 25087 M8NC 3M200M 10210 4 M8NF 4 * P800M 25138* - -
4 M8NC 4 * P200M 25093* M8NC 4 * M200M 10216*
H 630 3 M8NF 3P630H 25139 - -
225 3 M8NC 3P225M 25088 M8NC 3M225M 10211
100kA 700 3 M8NF 3P700H 25140 - -
4 M8NC 4 * P225M 25094* M8NC 4 * M225M 10217*
800 3 M8NF 3P800H 25141 - -
H 100 3 M8NC 3P100H 25095 M8NC 3M100H 10218

85kA 125 3 M8NC 3P125H 25096 M8NC 3M125H 10219


160 3 M8NC 3P160H 25097 M8NC 3M160H 10220 Accessories
180 3 M8NC 3P180H 25098 M8NC 3M180H 10221
200 3 M8NC 3P200H 25099 M8NC 3M200H 10222
Under-voltage release
225 3 M8NC 3P225H 25100 M8NC 3M225H 10223
Frame D
When voltage is 35%-70% of rated voltage, the under voltage release should make the
3SM8N-400 L 225 3 M8ND 3P225L 25101 M8ND 3M225L 10224
breaker reliable operation.
50kA 250 3 M8ND 3P250L 25102 M8ND 3M250L 10225
315 3 M8ND 3P315L 25103 M8ND 3M315L 10226 When the voltage is more than 85%~110% of rated voltage, the under voltage release
350 3 M8ND 3P350L 25104 M8ND 3M350L 10227 should make the breaker reliable operation.
400 3 M8ND 3P400L 25105 M8ND 3M400L 10228
When voltage is less than 35% of rated voltage, the under voltage release should
M 225 3 M8ND 3P225M 25106 M8ND 3M225M 10229
prevent breaker from making.
65kA 4 M8ND 4 * P225M 25111* M8ND 4 * M225M 10234*
power supply
250 3 M8ND 3P250M 25107 M8ND 3M250M 10230
4 M8ND 4 * P250M 25112* M8ND 4 * M250M 10235* UC 2 UC 1 P2

315 3 M8ND 3P315M 25108 M8ND 3M315M 10231 Frame Rated voltage Type Code Order Code
4 M8ND 4 * P315M 25113* M8ND 4 * M315M 10236* A 3SM8N-63 230V AC M8NA UR230A 25154
400V AC M8NA UR230A 25160
350 3 M8ND 3P350M 25109 M8ND 3M350M 10232
B 3SM8N-100 230V AC M8NB UR230A 25155
4 M8ND 4 * P350M 25114* M8ND 4 * M350M 10237* 400V AC M8NB UR230A 25161
400 3 M8ND 3P400M 25110 M8ND 3M400M 10233 C 3SM8N-225 230V AC M8NC UR230A 25156
400V AC M8NC UR230A 25162
4 M8ND 4 * P400M 25115* M8ND 4 * M400M 10238*
D 3SM8N-400 230V AC M8ND UR230A 25157
400V AC M8ND UR230A 25163
E 3SM8N-630 230V AC M8NE UR230A 25158
400V AC M8NE UR230A 25164
F 3SM8N-800 230V AC M8NF UR230A 25159
400V AC M8NF UR230A 25165

118 www.sassin.com www.sassin.com 119


Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM8N Series 3SM8N

Shunt release Tripping Characteristic

In 70% ~ 110% of the rated voltage, the breaker can reliably operate. For power distribution
No. Test current I/In Conventional time Start status
1 Conventional non-trip current 1.05 2h(In>63A), 1h(In≤63A) Cold status
Frame Rated voltage Type Code Order Code 2 Conventional trip current 1.3 2h(In>63A), 1h(In≤63A) Right after test No.1
A 3SM8N-63 230V AC M8NA SR230A 25142
400V AC M8NA SR400A 25148
For motor protection
110V DC M8NA SR110D 10244
220V DC M8NA SR220D 10250 No. Operational current Conventional time Start status Remark
B 3SM8N-100 230V AC M8NB SR230A 25143 1 1.0In 2h Cold status -
400V AC M8NB SR400A 25149
2 1.2In ≤2h Right after test No.1 -
110V DC M8NB SR110D 10245
220V DC M8NB SR220D 10251 ≤4min Cold status 10≤In≤225
3 1.5In
C 3SM8N-225 230V AC M8NC SR230A 25144 ≤8min Cold status 225≤In≤630
400V AC M8NC SR400A 25150
4s≤T≤10s Cold status 10≤In≤225
110V DC M8NC SR110D 10246 4 7.2In
220V DC M8NC SR220D 6s≤T≤20s Cold status 225≤In≤635
10252
D 3SM8N-400 230V AC M8ND SR230A 25145
400V AC M8ND SR400A 25151
110V DC M8ND SR110D 10247
220V DC M8ND SR220D 10253
M8NE SR230A 3SM8N-63、100 (10~32) Temperature emendation curve 3SM8N-63、100 (10~32) Characteristic curve
E 3SM8N-630 230V AC 25146
400V AC M8NE SR400A 25152
Power Distribution Electrics

Power Distribution Electrics


10000
110V DC M8NE SR110D 10248 7200
220V DC M8NE SR220D 10254 3600
F 3SM8N-800 230V AC M8NF SR230A 25147 1200
130 600
400V AC M8NF SR400A 25153
300

Rated current(%)
110V DC M8NF SR110D 10249 120 120
220V DC M8NF SR220D 10255 60
110 30

Action time(s)
20
100 10
Auxiliary contact 5
2
90 1
Indication of contacting status. 0.5
80 0.2
0.1
0.05
0 10 20 30 40 50 60 0.02
Frame Type Code Order Code
A 3SM8N-63 Left M8NA ACL 25166
1 2 3 4 5 7 8 10 20
Right M8NA ACR 10256
B 3SM8N-100 Left M8NB ACL 25167 Circumstance temperature(°C) Rated current multiple
when circuit breaker is Right M8NB ACR 10257
at breaking status
C 3SM8N-225 Left M8NC ACL 25168
Right M8NC ACR 10258
when circuit breaker is
at breaking status
D 3SM8N-400 Left M8ND ACL 25169
Right M8ND ACR 10259
E 3SM8N-630 Left M8NE ACL 25170
Connection chart
Right M8NE ACR 10260
F 3SM8N-800 Left M8NF ACL 25171 3SM8N-63、100 (40~100) Temperature emendation curve 3SM8N-63、100 (40 ~100) Characteristic curve
Power supply

Right M8NF ACR 10261


on loop
10000
7200
off loop
3600
130 1200
600
300
120 120
Alarm contact 60

Rated current(%)
110 30

Action time(s)
20
Indication of contacting status. 10
100
5
90 2
1
Frame Type Code Order Code 0.5
A 3SM8N-63 M8NA AMC 80 0.2
when circuit breaker is
25172
at breaking/making status
B 3SM8N-100 M8NB AMC 25173 0.1
0 10 20 30 40 50 60 0.05
when circuit breaker is
in “free release” (alarm)
C 3SM8N-225 M8NC AMC 25174 0.02
D 3SM8N-400 M8ND AMC 25175
Connection chart E 3SM8N-630 M8NE AMC 25176 1 2 3 4 5 7 8 10 20
Power supply F 3SM8N-800 M8NF AMC 25177
Circumstance temperature(°C) Rated current multiple

120 www.sassin.com www.sassin.com 121


Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM8N Series 3SM8N

3SM8N-225 Temperature emendation curve 3SM8N-225 Characteristic curve Release type codes of accessories

10000 Codes of acessories Installation types


130 7200 3SM8N-63L.M
3600 Electromag- Double
1200 Name of accessories 3SM8N-100L.M.H 3SM8N-400L.M.H 3SM8N-630L.M.H 3SM8N-800M.H
120 -netism trip trip
600 3SM8N-225L.M.H
Rated current(%)

300
110 120 3poles.4poles 3poles.4poles 3poles 3poles
60

Action time(s)
100 30
20 No- Accessories 200 300
10
90 5
2 Warning contact 208 308
80 1
0.5
0.2 Shunt trip 210 310
0 10 20 30 40 50 60 0.1
0.05
0.02 Auxiliary contact 220 320
1 2 3 4 5 7 8 10 20
Under-voltage shunt trip 230 330
Circumstance temperature(°C) Rated current multiple
Auxiliary contact of trip 240 340

Shunt trip under-voltage trip 250 350


Power Distribution Electrics

Power Distribution Electrics


2-group Auxiliary contact 260 360
3SM8N-400 Temperature emendation curve 3SM8N-400 Characteristic curve Auxiliary contact
270 370
Under-voltage trip
10000 Shunt trip
7200 218 318
130 3600 Warning contact
1200 Auxiliary contact
120 600 Warning contact 228 328
Rated current(%)

300
120 Under-voltage trip
Action time(s)

110 60 238 338


30 Warning contact
100 20
10 Shunt trip
5 Auxiliaty contact 248 348
90 2 Warning contact
1
80 0.5 2-group Auxiliary contact
0.2 268 368
0.1 Warning contact
0 10 20 30 40 50 60 0.05 Auxiliary contact
0.02 278 378
Under-voltage trip
1 2 3 4 5 7 8 10 20 Warning contact

Note: ○ Auxiliary contact ■ Shunt trip


Circumstance temperature(°C) Rated current multiple ● Warning contact ▲ Under-voltage trip

Left installation Right installation

Handle
3SM8N-630、800 Temperature emendation curve 3SM8N-630、800 Characteristic curve

10000
7200
130 3600
1200
Rated current(%)

120 600
300
110 120
60
Action time(s)

30
100 20
10
90 5
2
80 1
0.5
0.2
0 10 20 30 40 50 60 0.1
0.05
0.02
1 2 3 4 5 7 8 10 20

Circumstance temperature(°C) Rated current multiple

122 www.sassin.com www.sassin.com 123


Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM8N Series 3SM8N

Outline and installation dimensions


3SM8N-400、630、800 Outline and Installation Dimension(front connection)

3SM8N-63、100、225 Outline and Installation Dimension(front connection) Electric arc Electric arc
A isolation shutter A A1 isolation shutter

Electric arc G
isolation shutter

G1
A A A H5

Under-voltage trip

Under-voltage trip
G G H4
H2 F F

G1
H3

Under-voltage trip
Under-voltage trip

H4

C1
L1

L2

C
B
E

E
L
F
N
22 22
L1

L2

C
B
E

22 22

H3
H2

6-Фd H
4-Фd H
Power Distribution Electrics

Power Distribution Electrics


W1 W1 W1 W1 W1 H1(max)
W1 W1 H1(max) W
W1 W1 W1 W2
W
W2
3P
4P

Model

3SM8N-400M 3SM8N-630H
Model 3SM8N-400L 3SM8N-630L 3SM8N-630M
3SM8N-400H 3SM8N-800M/H
3SM8N-100M 3SM8N-225M
3SM8N-63L 3SM8N-63M 3SM8N-100L 3SM8N-225L C 102 129 134 134 154
3SM8N-100H 3SM8N-225H
C1 179 175 184 184 204
C 85 85 84 84 103 103
E 90 89 89 89 106
E 48 48 50.5 50.5 51 51
F 62 65 65 65 66
F 22 22 22 22 23 23
G 28 30.5 40 44 44
G 14 14 17 17 22 22
G1 13 10.5 13.5 13.5 12.5
G1 6.5 6.5 7.5 7.5 11.5 11.5
H 104 107 111 111 107
H 73 81 68 86 86.5 103
H1 155 150 160 160 148
H1 90 98.5 86 103 110 127
H2 38 39 44 44 33
H2 20 27 24 24 24 24 Dimensions
H3 6 6 6 6 4.5
Dimensions H3 4 4 4 4 4 4
H4 6 4.5 3.5 3.5 4.5
H4 6 6 7 7 5 5
H5 2.5 4.5 4.5 4.5 8
L 135 135 155 155 165 165
L 257 257 270 270 280
L1 170 173 255 255 360 360
L1 457 457 470 470 470
L2 117 117 136 136 144 144
L2 225 225 234 234 243
W 76 76 90 90 105 105
W 140 150 182 182 210
W1 25 25 30 30 35 35
W1 44 44 58 58 70
W2 -- 102.5 -- 120 -- 140
W2 198 -- 240 -- --
W3 -- -- -- 64.5 -- 74.5
A 44 44 58 58 70
A 25 25 30 30 35 35
Installation Installation A1 50 -- 58 -- --
B 117 117 130 130 126 126
Dimensions Dimensions B 194 194 200 200 243
φd 3.5 3.5 4.5X6 4.5X6 5 5
φd 7 7 7 7 7

124 www.sassin.com www.sassin.com 125


Moulded Case Circuit Breakers Moulded Case Circuit Breakers
Series 3SM8N Series 3SM8N

3SM8N-100L 3SM8N-225L 3SM8N-630H


3SM8N-63、100、225 Outline and installation dimension (Back connection)
Type 3SM8N-63L 3SM8N-100M 3SM8N-225M 3SM8N-400L 3SM8N-400M 3SM8N-630L 3SM8N-800M
M M
3SM8N-63M 3SM8N-100H 3SM8N-225H 3SM8N-400H 3SM8N-630M 3SM8N-800H
A 25 30 30 44 44 58 70
Φd 3.5 4.5x6(long hole) 5.5 7 7 7 7

H7

H7
Φd1 -- -- -- φ12.5 φ12.5 φ16.5 φ16.5

H6

H6
Φd2 6 8 8 9 9 9 12
ΦD 8 24 26 31 33 37 37
ΦD1 8 16 20 33 37 37 37

Dimensions of back connection & insert type


W1 W1 W1 W1 W1
H6 44 68 66 60 65 65 48
3P 4P
H7 66 108 110 120 120 125 125
H8 28 51 51 61 60 60 87
H9 38 68 72 -- 83.5 93 --
H10 44 79 91 99 106.5 112 106
Back connection stiletto chart
H11 8.5 17.5 17.5 22 21 21 26.5
W1 W1 W1 W1 W1
N L2 117 132 144 225 225 234 243
≥3
Power Distribution Electrics

L3 117 108 126 194 194 200 243

Power Distribution Electrics


A
A L4 97 95 93 165 163 165 173

L2
L3
L5 138 180 190 285 285 302 305
L3
L2

4-φd L6 80 95 110 145 155 185 215


4-φd 8-φD1
6-φD
M M6 M8N M10 -- -- -- --
K 50.2 60 70 60 60 100 90
3P 4P
J 60.7 62 54 129 130 123 143
M1 M5 M8N M8N M10 M10 M12 M14
W1 25 30 35 44 44 58 70

3SM8N-400、630、800 Outline and installation dimension(Back connection)


Фd1 Фd1
16

16
H7

H7
H6

H6

W1 W1 W1 W1 W1
3P 4P

Insert style

H10 Installation board stiletto chart


H9 Installation chart
L6
H8

M1 K 4-φd2
H11
L4

L5

Installation
L2
J

board

126 www.sassin.com www.sassin.com 127


Moulded Case Circuit Breakers with Earth Leakage Protection Moulded Case Circuit Breakers with Earth Leakage Protection
Series 3SM8L Series 3SM8L

Applications and functions Tripping characteristic

For power distribution


Protection of plant and equipment against overload or
Test No. Test current I/In Conventional time Start status Ambient temperature
damage by ground faults (ground-fault protection)
1 Conventional non-action time 1.05 1h (In≤63A) Cold status +40°C
Protection against fire hazard caused by insulation faults
2h (In>63A)
Switching and protection devices for motors, transformers 2 Conventional action time 1.30 1h (In≤63A) Right after test No.1 +40°C
and capacitors 2h (In>63A)
Disconnector units with features for stopping and
For motor protection
switching off in an emergency in conjunction with lockable
Test No. Setting current Conventional time Start status Ambient temperature
rotary operating mechanisms and terminal covers.
1 1.05In Inm=100A >2h no action Cold status +40°C
Inm=225A/400A >2h no action
Instruction of type code Inm=630A >2h no action
2 1.2In Inm=100A ≤2h action Right after test No.1 +40°C
Inm=225A/400A ≤2h action
M8L A 3 P 016 / 1 Here is code of N-pole type for 4 pole circuit breaker: Inm=630A ≤2h action
A: N-pole fixed without over-current release unit, it has 3 1.5In Inm=100A ≤4min action Heat status +40°C
Rated residual current(mA)
been connected all along, and does not act with other Inm=225A/400A ≤4min action
1: 100; 3: 300
Power Distribution Electrics

Power Distribution Electrics


Inm=630A ≤8min action
5: 500; 10: 1000 three poles to turn on or off.
4 7.2In Inm=100A ≥1s action Cold status +40°C
Rated current(A) B: N-pole fixed without over-current release unit, it acts Inm=225A/400A 4s<T≤10s action
16, 20, 25, 32, 40, 50, 63, 80, 100 (Frame A) with other three poles. Inm=630A 6s<T≤20s action
100, 125, 140, 160, 180, 200, 225 (Frame B)
225, 250, 315, 350, 400 (Frame C)
400, 500, 630 (Frame D) Action time of residual current protection

Protection type
P: Power protection; M: Motor protection Residual current 1I△n 2I△n 5I△n 10I△n
Non time-delay type Max. breaking time(s) 0.2 0.1 0.04 0.04
Poles(P): 3: 3P; 4: 4P
Time-delay type Max. breaking time(s) 0.5/1.15/2.15 0.35/1/2 0.25/0.9/1.9 0.25/0.9/1.9
Frame Ultimate non-driven time △t(s) - 0.1/0.5/1 - -
A: 3SM8L-100; B: 3SM8L-225
C: 3SM8L-400; D: 3SM8L-630
Outline and installation dimension.
Series code

Technical specifications

A D
a
Frame type A B C D
Standards IEC60947-2 IEC60947-2 IEC60947-2 IEC60947-2
IEC60947-4-1 IEC60947-4-1 IEC60947-4-1 IEC60947-4-1 1 3 5
Approval CE CE CE CE
ON
Number of poles 3,4 3,4 3,4 3,4
Frame Current Inm (A) 100 225 400 630

B
Rated current In(A) 16,20,25,32,40 100,125,140,160 225,250,315 400,500,630

b
50,63,80,100 180,200,225 350,400
Rated residual currents IΔn (mA) 100,300,500,1000 100,300,500,1000 100,300,500 100,300,500,100 OFF
Rated insulating voltage Ui (V) 800 800 800 800 4-Φd
Rated operating voltage, Ue (V) 400 400 400 400 2 4 6
Rated frequency (Hz) 50/60 50/60 50/60 50/60
Rated impulsed withstand voltage, Uimp(kV) 8 8 8 8
Rated ultimate short-circuit breaking capacity, Icu
(AC) 50-60 Hz 400V O-CO (kA) 35 35 50 80 Number Outline dimensions(mm) Installation dimensions(mm)
Type
Rated operating short-circuit breaking capacity,Ics of poles A B C D a b d
(AC) 50-60 Hz 400V O-CO-CO (kA) 22 25 35 35
Frame A 3 92 150 110 92 30 129 4.5
Mechanical life (times) 8500 7000 4000 4000
3SW8L-100 4 122 150 110 92 60 129 4.5
Electrical life (times.) 1500 1000 1000 1000
Flashover distance (mm) ≤50 ≤50 ≤100 ≤100 Frame B 3 107 165 110 90 35 126 4.5
Utilization category (IEC60947-2) A A A A 3SW8L-225 4 142 165 110 90 70 126 4.5
Ambient temperature -5 to +40℃, max. 95 % humidity Frame C 3 150 257 146.5 106.5 44 194 7
Storage temperature -40 to +75℃ 3SW8L-400 4 198 257 146.5 106.5 88 194 7
Altitude( Max) 2000 Frame D 3 210 280 155 115.5 70 243 7
3SW8L-630 4 280 280 155 115.5 70 243 7

128 www.sassin.com www.sassin.com 129


Moulded Case Circuit Breakers with Earth Leakage Protection Moulded Case Circuit Breakers with Earth Leakage Protection
Series 3SM8L Series 3SM8L

Selection and ordering data


Rated current Number of 100mA 300mA 500mA
In(A) Poles Type code Order code Type code Order code Type code Order code
Rated current Number of 100mA 300mA 500mA
Frame B For 4 poles, please complete the code by adding N-pole code
In(A) Poles Type code Order code Type code Order code Type code Order code
3SM8L-225 For motor protection
For 4 poles, please complete the code by adding N-pole code.
Frame A 100 3 M8LB 3M100/1 10295 M8LB 3M100/3 10302 M8LB 3M100/5 10309
3SM8L-100 For power distribution 4 M8LB 4 * M100/1 10430* M8LB 4 * M100/3 10437* M8LB 4 * M100/5 10444*
16 3 M8LA 3P016/1 25214 M8LA 3P016/3 25223 M8LA 3P016/5 25232 125 3 M8LB 3M125/1 10296 M8LB 3M125/3 10303 M8LB 3M125/5 10310
4 M8LA 4*P016/1 10331* M8LA 4 * P016/3 10340* M8LA 4 * P016/5 10349* 4 M8LB 4 * M125/1 10431* M8LB 4 * M125/3 10438* M8LB 4 * M125/5 10445*
20 3 M8LA 3P020/1 25215 M8LA 3P020/3 25224 M8LA 3P020/5 25233 140 3 M8LB 3M140/1 10297 M8LB 3M140/3 10304 M8LB 3M140/5 10311
4 M8LA 4 * P020/1 10332* M8LA 4 * P020/3 10341* M8LA 4 * P020/5 10350* 4 M8LB 4 * M140/1 10432* M8LB 4 * M140/3 10439* M8LB 4 * M140/5 10446*
25 3 M8LA 3P025/1 25216 M8LA 3P025/3 25225 M8LA 3P025/5 25234 160 3 M8LB 3M160/1 10298 M8LB 3M160/3 10305 M8LB 3M160/5 10312
4 M8LA 4 * P025/1 10333* M8LA 4 * P025/3 10342* M8LA 4 * P025/5 10351* 4 M8LB 4 * M160/1 10433* M8LB 4 * M160/3 10440* M8LB 4 * M160/5 10447*
32 3 M8LA 3P032/1 25217 M8LA 3P032/3 25226 M8LA 3P032/5 25235 180 3 M8LB 3M180/1 10299 M8LB 3M180/3 10306 M8LB 3M180/5 10313
4 M8LA 4 * P032/1 10334* M8LA 4 * P032/3 10343* M8LA 4 * P032/5 10352* 4 M8LB 4 * M180/1 10434* M8LB 4 * M180/3 10441* M8LB 4 * M180/5 10448*
40 3 M8LA 3P040/1 25218 M8LA 3P040/3 25227 M8LA 3P040/5 25236 200 3 M8LB 3M200/1 10300 M8LB 3M200/3 10307 M8LB 3M200/5 10314
4 M8LA 4 * P040/1 10335* M8LA 4 * P040/3 10344* M8LA 4 * P040/5 10353* 4 M8LB 4 * M200/1 10435* M8LB 4 * M200/3 10442* M8LB 4 * M200/5 10449*
50 3 M8LA 3P050/1 25219 M8LA 3P050/3 25228 M8LA 3P050/5 25237 225 3 M8LB 3M225/1 10301 M8LB 3M225/3 10308 M8LB 3M225/5 10315
4 M8LA 4 * P050/1 10336* M8LA 4 * P050/3 10345* M8LA 4 * P050/5 10354* 4 M8LB 4 * M225/1 10436* M8LB 4 * M225/3 10443* M8LB 4 * M225/5 10450*
Frame C
63 3 M8LA 3P063/1 25220 M8LA 3P063/3 25229 M8LA 3P063/5 25238
Power Distribution Electrics

Power Distribution Electrics


3SM8L-400 For power distribution
4 M8LA 4 * P063/1 10337* M8LA 4 * P063/3 10346* M8LA 4 * P063/5 10355*
225 3 M8LC 3P225/1 25262 M8LC 3P225/3 25267 M8LC 3P225/5 25272
80 3 M8LA 3P080/1 25221 M8LA 3P080/3 25230 M8LA 3P080/5 25239
4 M8LC 4 * P225/1 10379* M8LC 4 * P225/3 10384* M8LC 4 * P225/5 10389*
4 M8LA 4 * P080/1 10338* M8LA 4 * P080/3 10347* M8LA 4 * P080/5 10356*
250 3 M8LC 3P250/1 25263 M8LC 3P250/3 25268 M8LC 3P250/5 25273
100 3 M8LA 3P100/1 25222 M8LA 3P100/3 25231 M8LA 3P100/5 25240
4 M8LC 4 * P250/1 10380* M8LC 4 * P250/3 10385* M8LC 4 * P250/5 10390*
4 M8LA 4 * P100/1 10339* M8LA 4 * P100/3 10348* M8LA 4 * P100/5 10357*
315 3 M8LC 3P315/1 25264 M8LC 3P315/3 25269 M8LC 3P315/5 25274
For motor protection 4 M8LC 4 * P315/1 10381* M8LC 4 * P315/3 10386* M8LC 4 * P315/5 10391*
16 3 M8LA 3M016/1 10268 M8LA 3M016/3 10277 M8LA 3M016/5 10286 350 3 M8LC 3P350/1 25265 M8LC 3P350/3 25270 M8LC 3P350/5 25275
4 M8LA 4 * M016/1 10403* M8LA 4 * M016/3 10412* M8LA 4 * M016/5 10421* 4 M8LC 4 * P350/1 10382* M8LC 4 * P350/3 10387* M8LC 4 * P350/5 10392*
20 3 M8LA 3M020/1 10269 M8LA 3M020/3 10278 M8LA 3M020/5 10287 400 3 M8LC 3P400/1 25266 M8LC 3P400/3 25271 M8LC 3P400/5 25276
4 M8LA 4 * M020/1 10404* M8LA 4 * M020/3 10413* M8LA 4 * M020/5 10422* 4 M8LC 4 * P400/1 10383* M8LC 4 * P400/3 10388* M8LC 4 * P400/5 10393*
25 3 M8LA 3M025/1 10270 M8LA 3M025/3 10279 M8LA 3M025/5 10288
For motor protection
4 M8LA 4 * M025/1 10405* M8LA 4 * M025/3 10414* M8LA 4 * M025/5 10423*
225 3 M8LC 3M225/1 10316 M8LC 3M225/3 10321 M8LC 3M225/5 10326
32 3 M8LA 3M032/1 10271 M8LA 3M032/3 10280 M8LA 3M032/5 10289
4 M8LC 4 * M225/1 10451* M8LC 4 * M225/3 10456* M8LC 4 * M225/5 10461*
4 M8LA 4 * M032/1 10406* M8LA 4 * M032/3 10415* M8LA 4 * M032/5 10424*
250 3 M8LC 3M250/1 10317 M8LC 3M250/3 10322 M8LC 3M250/5 10327
40 3 M8LA 3M040/1 10272 M8LA 3M040/3 10281 M8LA 3M040/5 10290
4 M8LC 4 * M250/1 10452* M8LC 4 * M250/3 10457* M8LC 4 * M250/5 10462*
4 M8LA 4 * M040/1 10407* M8LA 4 * M040/3 10416* M8LA 4 * M040/5 10425*
315 3 M8LC 3M315/1 10318 M8LC 3M315/3 10323 M8LC 3M315/5 10328
50 3 M8LA 3M050/1 10273 M8LA 3M050/3 10282 M8LA 3M050/5 10291
4 M8LC 4 * M315/1 10453* M8LC 4 * M315/3 10458* M8LC 4 * M315/5 10463*
4 M8LA 4 * M050/1 10408* M8LA 4 * M050/3 10417* M8LA 4 * M050/5 10426*
350 3 M8LC 3M350/1 10319 M8LC 3M350/3 10324 M8LC 3M350/5 10329
63 3 M8LA 3M063/1 10274 M8LA 3M063/3 10283 M8LA 3M063/5 10292
4 M8LC 4 * M350/1 10454* M8LC 4 * M350/3 10459* M8LC 4 * M350/5 10464*
4 M8LA 4 * M063/1 10409* M8LA 4 * M063/3 10418* M8LA 4 * M063/5 10427*
400 3 M8LC 3M400/1 10320 M8LC 3M400/3 10325 M8LC 3M400/5 10330
80 3 M8LA 3M080/1 10275 M8LA 3M080/3 10284 M8LA 3M080/5 10293
4 M8LC 4 * M400/1 10455* M8LC 4 * M400/3 10460* M8LC 4 * M400/5 10465*
4 M8LA 4 * M080/1 10410* M8LA 4 * M080/3 10419* M8LA 4 * M080/5 10428* Frame D
100 3 M8LA 3M100/1 10276 M8LA 3M100/3 10285 M8LA 3M100/5 10294 3SM8L-630 For power distribution
4 M8LA 4 * M100/1 10411* M8LA 4 * M100/3 10420* M8LA 4 * M100/5 10429* 400 3 M8LD 3P400/3 25277 M8LD 3P400/5 25280 M8LD 3P400/10 25283
Frame B
4 M8LD 4 * P400/3 10394* M8LD 4 * P400/5 10397* M8LD 4 * P400/10 10400*
3SM8L-225 For power distribution
500 3 M8LD 3P500/3 25278 M8LD 3P500/5 25281 M8LD 3P500/10 25284
100 3 M8LB 3P100/1 25241 M8LB 3P100/3 25248 M8LB 3P100/5 25255
4 M8LD 4 * P500/3 10395* M8LD 4 * P500/5 10398* M8LD 4 * P500/10 10401*
4 M8LB 4 * P100/1 10358* M8LB 4 * P100/3 10365* M8LB 4 * P100/5 10372*
630 3 M8LD 3P630/3 25279 M8LD 3P630/5 25282 M8LD 3P630/10 25285
125 3 M8LB 3P125/1 25242 M8LB 3P125/3 25249 M8LB 3P125/5 25256
4 M8LD 4 * P630/3 10396* M8LD 4 * P630/5 10399* M8LD 4 * P630/10 10402*
4 M8LB 4 * P125/1 10359* M8LB 4 * P125/3 10366* M8LB 4 * P125/5 10373*
140 3 M8LB 3P140/1 25243 M8LB 3P140/3 25250 M8LB 3P140/5 25257
4 M8LB 4 * P140/1 10360* M8LB 4 * P140/3 10367* M8LB 4 * P140/5 10374*
160 3 M8LB 3P160/1 25244 M8LB 3P160/3 25251 M8LB 3P160/5 25258
4 M8LB 4 * P160/1 10361* M8LB 4 * P160/3 10368* M8LB 4 * P160/5 10375*
180 3 M8LB 3P180/1 25245 M8LB 3P180/3 25252 M8LB 3P180/5 25259
4 M8LB 4 * P180/1 10362* M8LB 4 * P180/3 10369* M8LB 4 * P180/5 10376*
200 3 M8LB 3P200/1 25246 M8LB 3P200/3 25253 M8LB 3P200/5 25260
4 M8LB 4 * P200/1 10363* M8LB 4 * P200/3 10370* M8LB 4 * P200/5 10377*
225 3 M8LB 3P225/1 25247 M8LB 3P225/3 25254 M8LB 3P225/5 25261
4 M8LB 4 * P225/1 10364* M8LB 4 * P225/3 10371* M8LB 4 * P225/5 10378*

130 www.sassin.com www.sassin.com 131


Automatic Transfer Switches
Automatic Transfer Switches
Series 3SAQ1 CB Class

General introduction of automatic transfer switches Features

Continuous and reliable power distribution Communication and signal system


Small size with simple structure
Easy operation, long service life
With the diversification of industrial process and IT Power conversion under the conditions of non-fire special
Both 3P and 4P are available
applications, a secure and reliable electricity supply has hazard should be considered in the design ;
Public power grid can be used as backup power; Single electric drive, smooth and noise-free, small impact
become an important asset which is playing an important
Need to use CB automatic switch device with over-current With mechanical interlock and electrical interlock ,
role in reducing production and maintenance costs . In
protection; reliable switching , both manual and automatic
emergency situations, it can become complex with
C curve protection products in line with IEC60896 are switching are avaible
mechanical devices looking after connecting, breaking,
suggested to be used as the end conversion electrical Switch is wired with connection terminal in the internal
conducting and isolating power. In addition, when electricity
appliances; for users, reflecting the circuit breaker status (open or
use is restricted or the power supply is overloaded, the load
Power conversion time should be less than 5s. For critical closed)
may need to be transfered from one supply to another.
load, please install uninterrupted power supply equipment There are a variety of indicators listed on panel
With superior performance, SASSIN dual power automatic
like UPS .
transfer switches meet all the above requirements to ensure
Structure and performance Instruction of type code
continuity and security of power supply.
Air condition and temperature control device
Power Distribution Electrics

Power Distribution Electrics


Structure
Reliability assurance of the device Power control under the conditions of non-fire special AQ1 3 D 06 N R

hazard should be considered in design ; The automatic transfer switch consists of MCB, a single
R: Self-propelled with restore
Automatic transfer switching equipment controller can Public power grid can be used as backup power; electric motor operating mechanism, mechanical

maximize the affordability of various types of electromagnetic Need to use CB automatic switch device with over-current interlocking, auxiliary systems, control circuit and other Breaking capacity
interference in industrial environments, and can as well as protection; components and are closed with plastic shell. All

ensure the operation reliability of automatic switch by D curve protection products in line with IEC60898 are components are installed on the same floor. There is a Rated current

the motor drive conversion mechanism via reliability test. suggested to be used as the end lighting electrical status indicator on the panel that accurately indicates the
Trip curve
appliances; state of the MCB and the whole set of instructions.
Power conversion time should be less than 5s. Poles
Reliability assurance of electricity supply system
Performance
Series code
Fire fighting system Automatic controllers (only R-type:automatic transfer
When the major power supply encounters power failure,
with automatic restore)detect the voltage of two-way
phase failure and undervoltage fault, the automatic There is only R type for 3SAQ1 series ATS at present.
Fire design includes power supply protection for terminal power (commonly used power and backup power) at the
switching equipment under the control of the controller Automatic transfer with automatic restore:
conditions like fire pumps, exhaust fans and fire elevators same time. Common power will work under the normal
will automatically switch to the backup power supply to If deviation of common power is monitored , ATS will
in particular disaster conditions; state . When the common power supply failure occurs,
ensure power system reliability. automatically switch the load from the common power
Need to use special power source like generators as backup
namely loss of pressure or A phase-off, the controller will
power; to backup power; if the power returns to normal, it will
automatically make the command switch switch to the
Security assurance of electricity supply system Need to use products with neutral line of 2 or 4 poles in automatically return to common power supply.
backup power supply;
volved in the transformation Need to use PC automatic
When common power is restored to normal, the
Specially designed automatic transfer switch controller switch device without over-current protection whose rated Technical specificatious
controller will automatically make the command switch
can automatically identify the over-current faults , the current should be 125% greater than its load current;
switch to the backup power supply, and no delay;
implementation original welding and mechanical failure Need to use the switch products with the fire control function Type 3SAQ1-63
Simultaneous two-way power anomalies are not allowed;
in power supply system and place the implementation Power conversion delay time should be set to 0. Execution circuit breaker 3SB71-63
When tripping occurs due to a small circuit breaker Number of poles (P) 3,4
original in a safe location to ensure the security of power Rated operating current (A) 6,10,16,20,25,32,40,50,63
failure, the device will remain in the trip state and let out
supply system. Emergency lighting in general location Rated operating voltage (VAC) 230/400
a warning signal. Wait for maintenance, and the the Rated control voltage (VAC) 230
handle should be reset and re-closed manually after Rated insulation voltage(VAC) 500
Emergency lighting under the conditions of non-fire special Rated ultimate short circuit 6 10
troubleshooting;
hazard should be considered in the distribution design ; breaking capacity at 400V AC (kA)
Another branch of public power grid can be used as backup In automatic mode, when there inputs DC24V fire signal, Rated short circuit 17
the controller will command all the disconnect switch, connecting capacity (kA)
power supply if the backup power is from same power Use category AC-33iB
transformer, neutral line will not participate in conversion; and then if undo the fire signal, restore the original state. Mechanical life (times) 10,000
Need to use CB automatic switch device with over-current Electrical life (times) 4,000
Ambient temperature -5~40℃, max. 95 % humidity
protection;
Storage temperature -40~+75℃
C curve protection products in line with IEC60898 are Altitude (Max.) 2,000
suggested to be used as the end lighting electrical
appliances; Power conversion time should be less than 5s.
132 www.sassin.com www.sassin.com 133
Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ1 CB Class Series 3SAQ1 CB Class

Wiring diagram Selection and ordering data

Rated working voltage ( VAC) : 230/400


Normal power Reserve Power Rated control voltage (VAC): 230
A11 B11 C11 N11 A11 B11 C11 N11
Rated breaking Rated Poles Curve B Curve C Curve D
X1 FUSE1 SM
A11 1
Red 1 1 capacity (kA) current (A) (p) Type code Order code Type code Order code Type code Order code
Red 3 3
A21 2
Tripping alarm 6 6 3 AQ1 3B06NR 19809 AQ1 3C06NR 19818 AQ1 3D06NR 19827
FUSE2
X2
6 4 AQ1 4B06NR 19836 AQ1 4C06NR 19845 AQ1 4D06NR 19854
N11 3 AQ1 3B10NR AQ1 3C10NR AQ1 3D10NR
Normal close 10 3 19810 19819 19828
N21 4
AC230V 5
5 4 AQ1 4B10NR 19837 AQ1 4C10NR 19846 AQ1 4D10NR 19855
Reserve close
AC230V 6 1 3 5 N 1 3 5 N 16 3 AQ1 3B16NR 19811 AQ1 3C16NR 19820 AQ1 3D16NR 19829
X5
4 4 AQ1 4B16NR 19838 AQ1 4C16NR 19847 AQ1 4D16NR 19856
B1 B2 11 12

Three

Four
12 Yellow

Three

Four
11
Reserve closing on indication 15 14 14
20 3 AQ1 3B20NR 19812 AQ1 3C20NR 19821 AQ1 3D20NR 19830
Normal closing on indication 16
Yellow
3
Yellow F11 11 4 AQ1 4B20NR 19839 AQ1 4C20NR 19848 AQ1 4D20NR 19857
Alarm 17 16 14 12
F2111
14 12
2 - 25 3 AQ1 3B25NR 19813 AQ1 3C25NR 19822 AQ1 3D25NR 19831
X3 SB
Q1 SW3 Q2 Double input for fire control DC24V 4 AQ1 4B25NR 19840 AQ1 4C25NR 19849 AQ1 4D25NR 19858
Double tripping 7
SW1 SW2 1 + 3 AQ1 3B32NR 19814 AQ1 3C32NR 19823 AQ1 3D32NR 19832
Normal closing 8 M 32
Reserve closing 9 4 AQ1 4B32NR 19841 AQ1 4C32NR 19850 AQ1 4D32NR 19859
Black
10 AQ1 3B40NR AQ1 3C40NR AQ1 3D40NR
Red, green and black Green
2 4 6 N 2 4 6 N External port wiring diagram 40 3 19815 19824 19833
11
electrical wire
12
Red 4 AQ1 4B40NR 19842 AQ1 4C40NR 19851 AQ1 4D40NR 19860
3 AQ1 3B50NR 19816 AQ1 3C50NR 19825 AQ1 3D50NR 19834
Power Distribution Electrics

50

Power Distribution Electrics


Indicator for the AC 230v, and external
X4 4 AQ1 4B50NR 19843 AQ1 4C50NR 19852 AQ1 4D50NR 19861
power supply is strictly prohibited
13
Manual/ Automatic switch
63 3 AQ1 3B63NR 19817 AQ1 3C63NR 19826 AQ1 3D63NR 19835
14
4 AQ1 4B63NR 19844 AQ1 4C63NR 19853 AQ1 4D63NR 19862
Wiring diagram 10 6 3 AQ1 3B06HR 19755 AQ1 3C06HR 19764 AQ1 3D06HR 19773
4 AQ1 4B06HR 19782 AQ1 4C06HR 19791 AQ1 4D06HR 19800
a) Q1、Q2 MCB(Double points for the location of the icon) F11、B1 The right auxiliary and alarm head of circuit breaker 10 3 AQ1 3B10HR 19756 AQ1 3C10HR 19765 AQ1 3D10HR 19774
F21、B2 The right auxiliary and alarm head of circuit breaker M Electric motor 4 AQ1 4B10HR 19783 AQ1 4C10HR 19792 AQ1 4D10HR 19801
SW1 Common closing limit switch in place SW2 Backup closing limit switch in place
16 3 AQ1 3B16HR 19757 AQ1 3C16HR 19766 AQ1 3D16HR 19775
4 AQ1 4B16HR 19784 AQ1 4C16HR 19793 AQ1 4D16HR 19802
SW3 Double points limit switch in place X 1 X2 X3 X4 X5 Connectors
20 3 AQ1 3B20HR 19758 AQ1 3C20HR 19767 AQ1 3D20HR 19776
FUSE1、FUSE2 Fuses SB Rocker Switch
4 AQ1 4B20HR 19785 AQ1 4C20HR 19794 AQ1 4D20HR 19803
SM Three-pin connector
25 3 AQ1 3B25HR 19759 AQ1 3C25HR 19768 AQ1 3D25HR 19777
b) Dotted line is for the user to connect and the remaining for factory, for user's reference
4 AQ1 4B25HR 19786 AQ1 4C25HR 19795 AQ1 4D25HR 19804
32 3 AQ1 3B32HR 19760 AQ1 3C32HR 19769 AQ1 3D32HR 19778
4 AQ1 4B32HR 19787 AQ1 4C32HR 19796 AQ1 4D32HR 19805
40 3 AQ1 3B40HR 19761 AQ1 3C40HR 19770 AQ1 3D40HR 19779
Outline and installation dimensions 4 AQ1 4B40HR 19788 AQ1 4C40HR 19797 AQ1 4D40HR 19806
50 3 AQ1 3B50HR 19762 AQ1 3C50HR 19771 AQ1 3D50HR 19780
4 AQ1 4B50HR 19789 AQ1 4C50HR 19798 AQ1 4D50HR 19807
63 3 AQ1 3B63HR 19763 AQ1 3C63HR 19772 AQ1 3D63HR 19781
unit in mm
4 AQ1 4B63HR 19790 AQ1 4C63HR 19799 AQ1 4D63HR 19808

3SAQ1-63/4R Automatic Transfer Switch Utilization categories:

AC-33iB: for system loads including cage motor and


UN Normal power UR resistive loads.
140max

Reserve Power
Ue 400V Uimp 4kV
85

Ie C63A Icn 10kA 003507

F 50Hz lcm
CB Class
17kA
AC-33iB
AC-33B: for motor load or mixture load including motors,
Standard IEC 60947-6-1

Tirpping
Alarm
resistive load and 30% incandescent load .
Automatic Power
Standard: IEC 60947-6-1
N Automatic /Manual R

290 4×Φ8.5 12

310max 137max

134 www.sassin.com www.sassin.com 135


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ2 CB Class Series 3SAQ2 CB Class

Featunes Instruction of type code Structure and performance

With 3 or 4-pole 3SM8 series of MCCB AQ2 Structure


B 3 P 100 L R U
With two structures of the integrated and split The automatic transfer switch consists of the electric
Structure type
Rated ultimate short circuit breaking capacity up to 100kA operation, molded case circuit breaker and accessories
U: Unitary type
Between two circuit breakers are placed reliable S: Separate type (auxiliary and alarm contacts), mechanical interlocking,
mechanical interlocks and electrical interlock protection, terminals, etc. All the components are installed in a metal
Control model
to achieve the complete elimination of the possibility plate and the mechanical interlock is mounted between
R: Automatic switch with restore
that the two circuit breakers close at the same time S: Automatic switch without restore two circuit breakers. The controller and the circuit breaker
Intelligent controller adopts microcontroller as the F: Grid-Generator
can be connected by the connectors.
control center with simple hardware, powerful function, Breaking capacity With a complete plastic casing, automatic controller is
easy expansion, and high reliability L: Standard breaking capacity installed close to the left of common power . CPU chip
M: Medium breaking capacity
Short-circuit, overload protection, overvoltage, and advanced and reliable electronic components are
H: High breaking capacity
undervoltage, phase auto-switch function and intelligent adopted in the internal to constitute a comprehensive
alarmfunction Rated current (A):
sampling and control circuit.
Frame A: 06,10,16,20,25,32,40,50,63
Intelligent operation motor protection function
Frame B: 16,20,25,32,40,50,63,80,100
Automatic switching parameters can be set freely in the Performance
Power Distribution Electrics

Power Distribution Electrics


Frame C: 100,125,140,160,180,200,225
external Frame D: 225,250,315,400
Automatic controller detects the voltage of two power
Frame E: 400,500,630
With fire interface circuit , when the fire control center supply at the same time. The controller defaults that the
Frame F: 630,700,800
conveys a control signal into the intelligent controller, power supply voltage 115% higher than rated voltage is
both two circuit breakers are to enter the sub-gate status Protection trip
overvoltage and the return value is 110%. 70% lower
P: Power distribution
With computer network interface, to achieve remote than the rated voltage is regarded as undervoltage, and
M: Motor protection
control, remote adjustment, remote communication, the return value is 75%. Users can set the voltage values
remote sensing and other functions Poles (P): 3: 3P; 4: 4P
by the controller knob according to different occasions
With a strong anti-interference ability, can work in the Frame code (60% -85%).
complex environment with strong electromagnetic A: 3SAQ2-63
CPU chip will judge after the accurate sampling of supply
B: 3SAQ2-100
interference voltage through the built-in A/D (analog to digital
C: 3SAQ2-225
D: 3SAQ2-400 conversion) signal converter. The results, through delay
Wiring diagram E: 3SAQ2-630
circuit, will drive corresponding relay instructions to give
F: 3SAQ2-800
the closing or sub- gate instruction to electric operating
Type 3SAQ2-63 3SAQ2-100 3SAQ2-225 3SAQ2-400 3SAQ2-630 3SAQ2-800 Series Name mechanism. The test results are displayed on the panel
Execution circuit breaker 3SM8-63 3SM8-100 3SM8-225 3SM8-400 3SM8-630 3SM8-800
Number of poles (P) 3, 4 3, 4 3, 4 3, 4 3, 4 3,4 with LED.
Rated operating current (A) 6,10,16,20,25, 16,20,25,32, 100,125,140, 225,250, 400,500, 630,700, There is no 4 poles cir c uit breaker for Frame F.
Automatic control by control points can be divided into
32,40,50,63 40,50,63,80,100 160,180,200,225 315,350,400 630 800 There is 4 poles circuit breaker for M type only (Medium
three types according to controlling function: automatic
Rated operating voltage (VAC) 400 400 400 400 400 400
breaking capacity type).
Rated control voltage (VAC) 230 230 230 230 230 230 transfer with automatic restore(R type), automatic
Rated insulation voltage (VAC) 500 800 800 800 800 800 Automatic transfer with automatic restore:
transfer without automatic restore(S type) and grid -
Rated ultimate short circuit 25 50 35 50 85 35 50 85 50 65 100 50 65 100 75 100 If deviation of common power is monitored , ATS will
breaking capacity at 400V AC (kA) generator (F-type) . The former two types are applicable
Use category AC-33B AC-33B AC-33B AC-33B AC-33B AC-33B
automatically switch the load from the common power to
to grid - grid supply system, the latter grid - generator
Mechanical life (times) 8500 7000 6500 4000 4000 2500 backup power; if the power returns to normal, it will
Electrical life (times)
system.
1500 3000 1500 1000 1000 1000
automatically return to common power supply.
Ambient temperature -5~40℃, max. 95 % humidity
Storage temperature -40~+75℃ Automatic transfer without automatic restore:
Altitude (Max.) 2,000
If deviation of common power is monitored, ATS will
automatically switch the load from the common power to
backup power; if the common power returns to normal,
ATS will not automatically return to the common power.
ATS can make it only when standby power failure occurs
or manual intervention exists.

136 www.sassin.com www.sassin.com 137


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ2 CB Class Series 3SAQ2 CB Class

Control logic diagram Outline and installation dimensions

Automatic transfer and restoration between the normal Automatic transfer and restoration between the normal
Unit in mm
and standby power supply (Type R) and generating power supply (Type F)

4×Φ8.5
UN UN
Operation of the
UR
Operation of the
UR

normal power supply normal power supply


In case of malfunction, it will be switched Malfunction of the power supply.
off and the action time is t1.

Normal power supply


UN UR The command (F3, F4) to start the generator
switching off is given out, The action time is t5.

The standby power supply starts The generator

D
C
operating, the action time is t2. starts operating
UN UN
The standby power supply
UR
The normal power
UR

starts operating supply still work


The normal power supply restores to The normal power supply will be switched
operation and the standby power supply off when the outputting value from the
is switched off, the action time is t3. generator reaches the setting.
Power Distribution Electrics

Power Distribution Electrics


UN UR The action time is t1. The command to
The standby power supply
unload the minor load is given out (E1, E2).
is switched off B
UN H2
The normal power supply
UR

The normal power supply starts operating


and the action time is t4. is switched off
A H1
UN
The generating power supply starts
The normal power supply
UR

operating, the action time is t2.


starts operating
UN UR
The generating power
supply is switched off Size A B
C D H1 H2
The normal power supply restores to operation, Specification 3P 4P 3P 4P
The generating power supply is switched off 3SAQ2-63 401 max. 425 max. 380±0.7 404±0.9 220±0.7 241 max. 150 max. 35±1
Automatic transfer without restoration between the and the action time is t3.
3SAQ2-100 435 max. 465 max. 414±0.9 444±0.9 220±0.7 241 max. 150 max. 35±1
normal and standby power supply (Type S) The command to stop the generator is 3SAQ2-225 475 max. 505 max. 444±0.9 474±0.9 220±0.7 241 max. 190 max. 35±1
given out (F1, F2), the action time is t6.
3SAQ2-400 591 max. 648 max. 560±0.9 617±0.9 310±0.7 341 max. 210 max. 35±1
The generator 3SAQ2-630 691 max. 746 max. 657±0.9 715±0.9 350±0.7 381 max. 250 max. 35±1
Operation of the
UN UR stop running
3SAQ2-800 751 max. - 690±0.9 - 350±0.7 381 max. 250 max. 35±1
normal power supply UN UR
The generating power
In case of malfunction, it will be switched supply starts operating
off and the action time is t1.
The normal power supply starts operating
Normal power supply
UN UR and the action time is t4.
switching off UN
The normal power supply
UR

The standby power supply starts operating, starts operating


the action time is t2.
UN
The standby power supply
UR

starts operating As for the normal and generating power supply, an


The normal power supply restores to
interrupted power supply of D.C.12V or D.C.24V with the
operation.
UN
power no less than 6W is required. In case the D.C. supply is
UR
The standby power supply
switched off, the control unit will have the same function as
still work
In case of malfunction, the standby power supply that of type R(automatic transfer and restoration).
will be switched off and the action time is t3.
UN UR
The standby power supply
is switched off
The normal power supply will operate and the
action time is t4.
UN
The normal power supply
UR

starts operating

138 www.sassin.com www.sassin.com 139


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ2 CB Class Series 3SAQ2 CB Class

Selection and ordering data For power distribution (Unitary type)


Frame Icn MCCB Rated current 3P 4P
specification
Type
at 400V AC (A) Type code Order Code Type code Order code
Rated working voltage ( VAC) : 400 16 AQ2B 3P016LRU 19944 - -
3SAQ2-100
Rated control voltage (VAC): 230 20 AQ2B 3P020LRU 19945 - -
25 AQ2B 3P025LRU 19946 - -
For power distribution (Unitary type) 32 AQ2B 3P032LRU 19947 - -
Frame Icn MCCB Rated current 3P 4P R 40 AQ2B 3P040LRU 19948 - -
specification
Type 50 AQ2B 3P050LRU 19949 - -
at 400V AC (A) Type code Order code Type code Order code
6 AQ2A 3P06LRU 19863 - - 63 AQ2B 3P063LRU 19950 - -
3SAQ2-63
10 AQ2A 3P10LRU 19864 - - 80 AQ2B 3P080LRU 19951 - -
16 AQ2A 3P16LRU 19865 - - 100 AQ2B 3P100LRU 19952 - -
20 AQ2A 3P20LRU 19866 - - 16 AQ2B 3P016LSU 19953 - -
R 25 AQ2A 3P25LRU 19867 - - 20 AQ2B 3P020LSU 19954 - -
32 AQ2A 3P32LRU 19868 - - 25 AQ2B 3P025LSU 19955 - -
40 AQ2A 3P40LRU 19869 - - 32 AQ2B 3P032LSU 19956 - -
50 AQ2A 3P50LRU 19870 - - 35kA 3SM8-100L S 40 AQ2B 3P040LSU 19957 - -
63 AQ2A 3P63LRU 19871 - - 50 AQ2B 3P050LSU 19958 - -
6 AQ2A 3P06LSU 19872 - - 63 AQ2B 3P063LSU 19959 - -
10 AQ2A 3P10LSU 19873 - - 80 AQ2B 3P080LSU 19960 - -
16 AQ2A 3P16LSU 19874 - - 100 AQ2B 3P100LSU 19961 - -
20 AQ2A 3P20LSU 19875 - - 16 AQ2B 3P016LFU 19962 - -
25kA 3SM8-63L S 25 AQ2A 3P25LSU 19876 - - 20 AQ2B 3P020LFU 19963 - -
Power Distribution Electrics

Power Distribution Electrics


32 AQ2A 3P32LSU 19877 - - 25 AQ2B 3P025LFU 19964 - -
40 AQ2A 3P40LSU 19878 - - 32 AQ2B 3P032LFU 19965 - -
50 AQ2A 3P50LSU 19879 - - F 40 AQ2B 3P040LFU 19966 - -
63 AQ2A 3P63LSU 19880 - - 50 AQ2B 3P050LFU 19967 - -
6 AQ2A 3P06LFU 19881 - - 63 AQ2B 3P063LFU 19968 - -
10 AQ2A 3P10LFU 19882 - - 80 AQ2B 3P080LFU 19969 - -
16 AQ2A 3P16LFU 19883 - - 100 AQ2B 3P100LFU 19970 - -
20 AQ2A 3P20LFU 19884 - - 16 AQ2B 3P016MRU 19971 AQ2B 4P016MRU 19998
F 25 AQ2A 3P25LFU 19885 - - 20 AQ2B 3P020MRU 19972 AQ2B 4P020MRU 19999
32 AQ2A 3P32LFU 19886 - - 25 AQ2B 3P025MRU 19973 AQ2B 4P025MRU 30001
40 AQ2A 3P40LFU 19887 - - 32 AQ2B 3P032MRU 19974 AQ2B 4P032MRU 30002
50 AQ2A 3P50LFU 19888 - - R 40 AQ2B 3P040MRU 19975 AQ2B 4P040MRU 30003
63 AQ2A 3P63LFU 19889 - - 50 AQ2B 3P050MRU 19976 AQ2B 4P050MRU 30004
6 AQ2A 3P06MRU 19890 AQ2A 4P06MRU 19917 63 AQ2B 3P063MRU 19977 AQ2B 4P063MRU 30005
10 AQ2A 3P10MRU 19891 AQ2A 4P10MRU 19918 80 AQ2B 3P080MRU 19978 AQ2B 4P080MRU 30006
16 AQ2A 3P16MRU 19892 AQ2A 4P16MRU 19919 100 AQ2B 3P100MRU 19979 AQ2B 4P100MRU 30007
20 AQ2A 3P20MRU 19893 AQ2A 4P20MRU 19920 16 AQ2B 3P016MSU 19980 AQ2B 4P016MSU 30008
R 25 AQ2A 3P25MRU 19894 AQ2A 4P25MRU 19921 20 AQ2B 3P020MSU 19981 AQ2B 4P020MSU 30009
32 AQ2A 3P32MRU 19895 AQ2A 4P32MRU 19922 25 AQ2B 3P025MSU 19982 AQ2B 4P025MSU 30010
40 AQ2A 3P40MRU 19896 AQ2A 4P40MRU 19923 32 AQ2B 3P032MSU 19983 AQ2B 4P032MSU 30011
50 AQ2A 3P50MRU 19897 AQ2A 4P50MRU 19924 50kA 3SM8-100M S 40 AQ2B 3P040MSU 19984 AQ2B 4P040MSU 30012
63 AQ2A 3P63MRU 19898 AQ2A 4P63MRU 19925 50 AQ2B 3P050MSU 19985 AQ2B 4P050MSU 30013
6 AQ2A 3P06MSU 19899 AQ2A 4P06MSU 19926 63 AQ2B 3P063MSU 19986 AQ2B 4P063MSU 30014
10 AQ2A 3P10MSU 19900 AQ2A 4P10MSU 19927 80 AQ2B 3P080MSU 19987 AQ2B 4P080MSU 30015
16 AQ2A 3P16MSU 19901 AQ2A 4P16MSU 19928 100 AQ2B 3P100MSU 19988 AQ2B 4P100MSU 30016
20 AQ2A 3P20MSU 19902 AQ2A 4P20MSU 19929 16 AQ2B 3P016MFU 19989 AQ2B 4P016MFU 30017
50kA 3SM8-63M S 25 AQ2A 3P25MSU 19903 AQ2A 4P25MSU 19930 20 AQ2B 3P020MFU 19990 AQ2B 4P020MFU 30018
32 AQ2A 3P32MSU 19904 AQ2A 4P32MSU 19931 25 AQ2B 3P025MFU 19991 AQ2B 4P025MFU 30019
40 AQ2A 3P40MSU 19905 AQ2A 4P40MSU 19932 32 AQ2B 3P032MFU 19992 AQ2B 4P032MFU 30020
50 AQ2A 3P50MSU 19906 AQ2A 4P50MSU 19933 F 40 AQ2B 3P040MFU 19993 AQ2B 4P040MFU 30021
63 AQ2A 3P63MSU 19907 AQ2A 4P63MSU 19934 50 AQ2B 3P050MFU 19994 AQ2B 4P050MFU 30022
6 AQ2A 3P06MFU 19908 AQ2A 4P06MFU 19935 63 AQ2B 3P063MFU 19995 AQ2B 4P063MFU 30023
10 AQ2A 3P10MFU 19909 AQ2A 4P10MFU 19936 80 AQ2B 3P080MFU 19996 AQ2B 4P080MFU 30024
16 AQ2A 3P16MFU 19910 AQ2A 4P16MFU 19937 100 AQ2B 3P100MFU 19997 AQ2B 4P100MFU 30025
20 AQ2A 3P20MFU 19911 AQ2A 4P20MFU 19938
F 25 AQ2A 3P25MFU 19912 AQ2A 4P25MFU 19939
32 AQ2A 3P32MFU 19913 AQ2A 4P32MFU 19940
40 AQ2A 3P40MFU 19914 AQ2A 4P40MFU 19941
50 AQ2A 3P50MFU 19915 AQ2A 4P50MFU 19942
63 AQ2A 3P63MFU 19916 AQ2A 4P63MFU 19943

140 www.sassin.com www.sassin.com 141


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ2 CB Class Series 3SAQ2 CB Class

For power distribution (Unitary type) For power distribution (Unitary type)
Frame Icn MCCB Rated current 3P 4P Frame Icn MCCB Rated current 3P 4P
specification
Type specification
Type
at 400V AC (A) Type code Order code Type code Order code at 400V AC (A) Type code Order code Type code Order code
3SAQ2-100 16 AQ2B 3P016HRU 30026 - - 3SAQ2-225 100 AQ2C 3P100HRU 30116 - -
20 AQ2B 3P020HRU 30027 - - 125 AQ2C 3P125HRU 30117 - -
25 AQ2B 3P025HRU 30028 - - 140 AQ2C 3P140HRU 30118 - -
32 AQ2B 3P032HRU 30029 - - R 160 AQ2C 3P160HRU 30119 - -
R 40 AQ2B 3P040HRU 30030 - - 180 AQ2C 3P180HRU 30120 - -
50 AQ2B 3P050HRU 30031 - - 200 AQ2C 3P200HRU 30121 - -
63 AQ2B 3P063HRU 30032 - - 225 AQ2C 3P225HRU 30122 - -
80 AQ2B 3P080HRU 30033 - - 100 AQ2C 3P100HSU 30123 - -
100 AQ2B 3P100HRU 30034 - - 125 AQ2C 3P125HSU 30124 - -
16 AQ2B 3P016HSU 30035 - - 140 AQ2C 3P140HSU 30125 - -
20 AQ2B 3P020HSU 30036 - - 85kA 3SM8-225H S 160 AQ2C 3P160HSU 30126 - -
25 AQ2B 3P025HSU 30037 - - 180 AQ2C 3P180HSU 30127 - -
32 AQ2B 3P032HSU 30038 - - 200 AQ2C 3P200HSU 30128 - -
85kA 3SM8-100H S 40 AQ2B 3P040HSU 30039 - - 225 AQ2C 3P225HSU 30129 - -
50 AQ2B 3P050HSU 30040 - - 100 AQ2C 3P100HFU 30130 - -
63 AQ2B 3P063HSU 30041 - - 125 AQ2C 3P125HFU 30131 - -
80 AQ2B 3P080HSU 30042 - - 140 AQ2C 3P140HFU 30132 - -
100 AQ2B 3P100HSU 30043 - - F 160 AQ2C 3P160HFU 30133 - -
16 AQ2B 3P016HFU 30044 - - 180 AQ2C 3P180HFU 30134 - -
20 AQ2B 3P020HFU 30045 - - 200 AQ2C 3P200HFU 30135 - -
Power Distribution Electrics

Power Distribution Electrics


25 AQ2B 3P025HFU 30046 - - 225 AQ2C 3P225HFU 30136 - -
32 AQ2B 3P032HFU 30047 - - 3SAQ2-400 225 AQ2D 3P225LRU 30137 - -
F 40 AQ2B 3P040HFU 30048 - - 250 AQ2D 3P250LRU 30138 - -
50 AQ2B 3P050HFU 30049 - - R 315 AQ2D 3P315LRU 30139 - -
63 AQ2B 3P063HFU 30050 - - 350 AQ2D 3P250LRU 30140 - -
80 AQ2B 3P080HFU 30051 - - 400 AQ2D 3P400LRU 30141 - -
100 AQ2B 3P100HFU 30052 - - 225 AQ2D 3P225LSU 30142 - -
3SAQ2-225 100 AQ2C 3P100LRU 30053 - - 250 AQ2D 3P250LSU 30143 - -
125 AQ2C 3P125LRU 30054 - - 50kA 3SM8-400L S 315 AQ2D 3P315LSU 30144 - -
140 AQ2C 3P140LRU 30055 - - 350 AQ2D 3P250LSU 30145 - -
R 160 AQ2C 3P160LRU 30056 - - 400 AQ2D 3P400LSU 30146 - -
180 AQ2C 3P180LRU 30057 - - 225 AQ2D 3P225LFU 30147 - -
200 AQ2C 3P200LRU 30058 - - 250 AQ2D 3P250LFU 30148 - -
225 AQ2C 3P225LRU 30059 - - F 315 AQ2D 3P315LFU 30149 - -
100 AQ2C 3P100LSU 30060 - - 350 AQ2D 3P250LFU 30150 - -
125 AQ2C 3P125LSU 30061 - - 400 AQ2D 3P400LFU 30151 - -
140 AQ2C 3P140LSU 30062 - - 225 AQ2D 3P225MRU 30152 AQ2D 4P225MRU 30167
35kA 3SM8-225L S 160 AQ2C 3P160LSU 30063 - - 250 AQ2D 3P250MRU 30153 AQ2D 4P250MRU 30168
180 AQ2C 3P180LSU 30064 - - R 315 AQ2D 3P315MRU 30154 AQ2D 4P315MRU 30169
200 AQ2C 3P200LSU 30065 - - 350 AQ2D 3P250MRU 30155 AQ2D 4P250MRU 30170
225 AQ2C 3P225LSU 30066 - - 400 AQ2D 3P400MRU 30156 AQ2D 4P400MRU 30171
100 AQ2C 3P100LFU 30067 - - 225 AQ2D 3P225MSU 30157 AQ2D 4P225MSU 30172
125 AQ2C 3P125LFU 30068 - - 250 AQ2D 3P250MSU 30158 AQ2D 4P250MSU 30173
140 AQ2C 3P140LFU 30069 - - 65kA 3SM8-400M S 315 AQ2D 3P315MSU 30159 AQ2D 4P315MSU 30174
F 160 AQ2C 3P160LFU 30070 - - 350 AQ2D 3P250MSU 30160 AQ2D 4P250MSU 30175
180 AQ2C 3P180LFU 30071 - - 400 AQ2D 3P400MSU 30161 AQ2D 4P400MSU 30176
200 AQ2C 3P200LFU 30072 - - 225 AQ2D 3P225MFU 30162 AQ2D 4P225MFU 30177
225 AQ2C 3P225LFU 30073 - - 250 AQ2D 3P250MFU 30163 AQ2D 4P250MFU 30178
100 AQ2C 3P100MRU 30074 AQ2C 4P100MRU 30095 F 315 AQ2D 3P315MFU 30164 AQ2D 4P315MFU 30179
125 AQ2C 3P125MRU 30075 AQ2C 4P125MRU 30096 350 AQ2D 3P250MFU 30165 AQ2D 4P250MFU 30180
140 AQ2C 3P140MRU 30076 AQ2C 4P140MRU 30097 400 AQ2D 3P400MFU 30166 AQ2D 4P400MFU 30181
R 160 AQ2C 3P160MRU 30077 AQ2C 4P160MRU 30098 225 AQ2D 3P225HRU 30182 - -
180 AQ2C 3P180MRU 30078 AQ2C 4P180MRU 30099 250 AQ2D 3P250HRU 30183 - -
200 AQ2C 3P200MRU 30079 AQ2C 4P200MRU 30100 R 315 AQ2D 3P315HRU 30184 - -
225 AQ2C 3P225MRU 30080 AQ2C 4P225MRU 30101 350 AQ2D 3P250HRU 30185 - -
100 AQ2C 3P100MSU 30081 AQ2C 4P100MSU 30102 - -
400 AQ2D 3P400HRU 30186
125 AQ2C 3P125MSU 30082 AQ2C 4P125MSU 30103 - -
225 AQ2D 3P225HSU 30187
140 AQ2C 3P140MSU 30083 AQ2C 4P140MSU 30104 - -
250 AQ2D 3P250HSU 30188
50kA 3SM8-225M S 160 AQ2C 3P160MSU 30084 AQ2C 4P160MSU 30105 - -
100kA 3SM8-400H S 315 AQ2D 3P315HSU 30189
180 AQ2C 3P180MSU 30085 AQ2C 4P180MSU 30106
350 AQ2D 3P250HSU 30190 - -
200 AQ2C 3P200MSU 30086 AQ2C 4P200MSU 30107
400 AQ2D 3P400HSU 30191 - -
225 AQ2C 3P225MSU 30087 AQ2C 4P225MSU 30108
225 AQ2D 3P225HFU 30192 - -
100 AQ2C 3P100MFU 30088 AQ2C 4P100MFU 30109
250 AQ2D 3P250HFU 30193 - -
125 AQ2C 3P125MFU 30089 AQ2C 4P125MFU 30110
F 315 AQ2D 3P315HFU 30194 - -
140 AQ2C 3P140MFU 30090 AQ2C 4P140MFU 30111
AQ2C 3P160MFU 30091 AQ2C 4P160MFU 30112 350 AQ2D 3P250HFU 30195 - -
F 160
180 AQ2C 3P180MFU 30092 AQ2C 4P180MFU 30113 400 AQ2D 3P400HFU 30196 - -
200 AQ2C 3P200MFU 30093 AQ2C 4P200MFU 30114
225 AQ2C 3P225MFU 30094 AQ2C 4P225MFU 30115

142 www.sassin.com www.sassin.com 143


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ2 CB Class Series 3SAQ2 CB Class

For power distribution (Unitary type) For power distribution (Separate type)
Frame Icn MCCB Rated current 3P 4P Frame Icn MCCB Rated current 3P 4P
specification
Type specification
Type
at 400V AC (A) Type code Order code Type code Order code at 400V AC (A) Type code Order code Type code Order code
3SAQ2-630 400 AQ2E 3P400LRU 30197 - - 3SAQ2-63 6 AQ2A 3P06LRS 30260 - -
R 500 AQ2E 3P500LRU 30198 - - 10 AQ2A 3P10LRS 30261 - -
630 AQ2E 3P630LRU 30199 - - 16 AQ2A 3P16LRS 30262 - -
400 AQ2E 3P400LSU 30200 - - 20 AQ2A 3P20LRS 30263 - -
50kA 3SM8-630L S 500 AQ2E 3P500LSU 30201 - - R 25 AQ2A 3P25LRS 30264 - -
630 AQ2E 3P630LSU 30202 - - 32 AQ2A 3P32LRS 30265 - -
400 AQ2E 3P400LFU 30203 - - 40 AQ2A 3P40LRS 30266 - -
F 500 AQ2E 3P500LFU 30204 - - 50 AQ2A 3P50LRS 30267 - -
630 AQ2E 3P630LFU 30205 - - 63 AQ2A 3P63LRS 30268 - -
400 AQ2E 3P400MRU 30206 AQ2E 4P400MRU 30215 6 AQ2A 3P06LSS 30269 - -
R 500 AQ2E 3P500MRU 30207 AQ2E 4P500MRU 30216 10 AQ2A 3P10LSS 30270 - -
630 AQ2E 3P630MRU 30208 AQ2E 4P630MRU 30217 16 AQ2A 3P16LSS 30271 - -
400 AQ2E 3P400MSU 30209 AQ2E 4P400MSU 30218 20 AQ2A 3P20LSS 30272 - -
65kA 3SM8-630M S 500 AQ2E 3P500MSU 30210 AQ2E 4P500MSU 30219 25kA 3SM8-63L S 25 AQ2A 3P25LSS 30273 - -
630 AQ2E 3P630MSU 30211 AQ2E 4P630MSU 30220 32 AQ2A 3P32LSS 30274 - -
400 AQ2E 3P400MFU 30212 AQ2E 4P400MFU 30221 40 AQ2A 3P40LSS 30275 - -
F 500 AQ2E 3P500MFU 30213 AQ2E 4P500MFU 30222 50 AQ2A 3P50LSS 30276 - -
630 AQ2E 3P630MFU 30214 AQ2E 4P630MFU 30223 63 AQ2A 3P63LSS 30277 - -
400 AQ2E 3P400HRU 30224 - - 6 AQ2A 3P06LFS 30278 - -
R 500 AQ2E 3P500HRU 30225 - - 10 AQ2A 3P10LFS 30279 - -
Power Distribution Electrics

Power Distribution Electrics


630 AQ2E 3P630HRU 30226 - - 16 AQ2A 3P16LFS 30280 - -
400 AQ2E 3P400HSU 30227 - - 20 AQ2A 3P20LFS 30281 - -
100kA 3SM8-630H S 500 AQ2E 3P500HSU 30228 - - F 25 AQ2A 3P25LFS 30282 - -
630 AQ2E 3P630HSU 30229 - - 32 AQ2A 3P32LFS 30283 - -
400 AQ2E 3P400HFU 30230 - - 40 AQ2A 3P40LFS 30284 - -
F 500 AQ2E 3P500HFU 30231 - - 50 AQ2A 3P50LFS 30285 - -
630 AQ2E 3P630HFU 30232 - - 63 AQ2A 3P63LFS 30286 - -
3SAQ2-800 630 AQ2F 3P630MRU 30233 AQ2F 4P630MRU 30242 6 AQ2A 3P06MRS 30287 AQ2A 4P06MRS 30314
R 700 AQ2F 3P700MRU 30234 AQ2F 4P700MRU 30243 10 AQ2A 3P10MRS 30288 AQ2A 4P10MRS 30315
800 AQ2F 3P800MRU 30235 AQ2F 4P800MRU 30244 16 AQ2A 3P16MRS 30289 AQ2A 4P16MRS 30316
630 AQ2F 3P630MSU 30236 AQ2F 4P630MSU 30245 20 AQ2A 3P20MRS 30290 AQ2A 4P20MRS 30317
75kA 3SM8-630M S 700 AQ2F 3P700MSU 30237 AQ2F 4P700MSU 30246 R 25 AQ2A 3P25MRS 30291 AQ2A 4P25MRS 30318
800 AQ2F 3P800MSU 30238 AQ2F 4P800MSU 30247 32 AQ2A 3P32MRS 30292 AQ2A 4P32MRS 30319
630 AQ2F 3P630MFU 30239 AQ2F 4P630MFU 30248 40 AQ2A 3P40MRS 30293 AQ2A 4P40MRS 30320
F 700 AQ2F 3P700MFU 30240 AQ2F 4P700MFU 30249 50 AQ2A 3P50MRS 30294 AQ2A 4P50MRS 30321
800 AQ2F 3P800MFU 30241 AQ2F 4P800MFU 30250 63 AQ2A 3P63MRS 30295 AQ2A 4P63MRS 30322
630 AQ2F 3P630HRU 30251 - - 6 AQ2A 3P06MSS 30296 AQ2A 4P06MSS 30323
R 700 AQ2F 3P700HRU 30252 - - 10 AQ2A 3P10MSS 30297 AQ2A 4P10MSS 30324
800 AQ2F 3P800HRU 30253 - - 16 AQ2A 3P16MSS 30298 AQ2A 4P16MSS 30325
630 AQ2F 3P630HSU 30254 - - 20 AQ2A 3P20MSS 30299 AQ2A 4P20MSS 30326
100kA 3SM8-630H S 700 AQ2F 3P700HSU 30255 - - 50kA 3SM8-63M S 25 AQ2A 3P25MSS 30300 AQ2A 4P25MSS 30327
800 AQ2F 3P800HSU 30256 - - 32 AQ2A 3P32MSS 30301 AQ2A 4P32MSS 30328
630 AQ2F 3P630HFU 30257 - - 40 AQ2A 3P40MSS 30302 AQ2A 4P40MSS 30329
F 700 AQ2F 3P700HFU 30258 - - 50 AQ2A 3P50MSS 30303 AQ2A 4P50MSS 30330
800 AQ2F 3P800HFU 30259 - - 63 AQ2A 3P63MSS 30304 AQ2A 4P63MSS 30331
6 AQ2A 3P06MFS 30305 AQ2A 4P06MFS 30332
10 AQ2A 3P10MFS 30306 AQ2A 4P10MFS 30333
16 AQ2A 3P16MFS 30307 AQ2A 4P16MFS 30334
20 AQ2A 3P20MFS 30308 AQ2A 4P20MFS 30335
F 25 AQ2A 3P25MFS 30309 AQ2A 4P25MFS 30336
32 AQ2A 3P32MFS 30310 AQ2A 4P32MFS 30337
40 AQ2A 3P40MFS 30311 AQ2A 4P40MFS 30338
50 AQ2A 3P50MFS 30312 AQ2A 4P50MFS 30339
63 AQ2A 3P63MFS 30313 AQ2A 4P63MFS 30340

144 www.sassin.com www.sassin.com 145


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ2 CB Class Series 3SAQ2 CB Class

For power distribution (Separate type) For power distribution (Separate type)
Frame Icn MCCB Rated current 3P 4P Frame Icn MCCB Rated current 3P 4P
specification
Type specification
Type
at 400V AC (A) Type code Order code Type code Order code at 400V AC (A) Type code Order code Type code Order code
3SAQ2-100 16 AQ2B 3P016LRS 30341 - - 3SAQ2-100 16 AQ2B 3P016HRS 30422 - -
20 AQ2B 3P020LRS 30342 - - 20 AQ2B 3P020HRS 30423 - -
25 AQ2B 3P025LRS 30343 - - 25 AQ2B 3P025HRS 30424 - -
32 AQ2B 3P032LRS 30344 - - 32 AQ2B 3P032HRS 30425 - -
R 40 AQ2B 3P040LRS 30345 - - R 40 AQ2B 3P040HRS 30426 - -
50 AQ2B 3P050LRS 30346 - - 50 AQ2B 3P050HRS 30427 - -
63 AQ2B 3P063LRS 30347 - - 63 AQ2B 3P063HRS 30428 - -
80 AQ2B 3P080LRS 30348 - - 80 AQ2B 3P080HRS 30429 - -
100 AQ2B 3P100LRS 30349 - - 100 AQ2B 3P100HRS 30430 - -
16 AQ2B 3P016LSS 30350 - - 16 AQ2B 3P016HSS 30431 - -
20 AQ2B 3P020LSS 30351 - - 20 AQ2B 3P020HSS 30432 - -
25 AQ2B 3P025LSS 30352 - - 25 AQ2B 3P025HSS 30433 - -
32 AQ2B 3P032LSS 30353 - - 32 AQ2B 3P032HSS 30434 - -
35kA 3SM8-100L S 40 AQ2B 3P040LSS 30354 - - 85kA 3SM8-100H S 40 AQ2B 3P040HSS 30435 - -
50 AQ2B 3P050LSS 30355 - - 50 AQ2B 3P050HSS 30436 - -
63 AQ2B 3P063LSS 30356 - - 63 AQ2B 3P063HSS 30437 - -
80 AQ2B 3P080LSS 30357 - - 80 AQ2B 3P080HSS 30438 - -
100 AQ2B 3P100LSS 30358 - - 100 AQ2B 3P100HSS 30439 - -
16 AQ2B 3P016LFS 30359 - - 16 AQ2B 3P016HFS 30440 - -
20 AQ2B 3P020LFS 30360 - - 20 AQ2B 3P020HFS 30441 - -
Power Distribution Electrics

Power Distribution Electrics


25 AQ2B 3P025LFS 30361 - - 25 AQ2B 3P025HFS 30442 - -
32 AQ2B 3P032LFS 30362 - - 32 AQ2B 3P032HFS 30443 - -
F 40 AQ2B 3P040LFS 30363 - - F 40 AQ2B 3P040HFS 30444 - -
50 AQ2B 3P050LFS 30364 - - 50 AQ2B 3P050HFS 30445 - -
63 AQ2B 3P063LFS 30365 - - 63 AQ2B 3P063HFS 30446 - -
80 AQ2B 3P080LFS 30366 - - 80 AQ2B 3P080HFS 30447 - -
100 AQ2B 3P100LFS 30367 - - 100 AQ2B 3P100HFS 30448 - -
16 AQ2B 3P016MRS 30368 AQ2B 4P016MRS 30395 3SAQ2-225 100 AQ2C 3P100LRS 30449 - -
20 AQ2B 3P020MRS 30369 AQ2B 4P020MRS 30396 125 AQ2C 3P125LRS 30450 - -
25 AQ2B 3P025MRS 30370 AQ2B 4P025MRS 30397 140 AQ2C 3P140LRS 30451 - -
32 AQ2B 3P032MRS 30371 AQ2B 4P032MRS 30398 R 160 AQ2C 3P160LRS 30452 - -
R 40 AQ2B 3P040MRS 30372 AQ2B 4P040MRS 30399 180 AQ2C 3P180LRS 30453 - -
50 AQ2B 3P050MRS 30373 AQ2B 4P050MRS 30400 200 AQ2C 3P200LRS 30454 - -
63 AQ2B 3P063MRS 30374 AQ2B 4P063MRS 30401 225 AQ2C 3P225LRS 30455 - -
80 AQ2B 3P080MRS 30375 AQ2B 4P080MRS 30402 100 AQ2C 3P100LSS 30456 - -
100 AQ2B 3P100MRS 30376 AQ2B 4P100MRS 30403 125 AQ2C 3P125LSS 30457 - -
16 AQ2B 3P016MSS 30377 AQ2B 4P016MSS 30404 140 AQ2C 3P140LSS 30458 - -
20 AQ2B 3P020MSS 30378 AQ2B 4P020MSS 30405 35kA 3SM8-225L S 160 AQ2C 3P160LSS 30459 - -
25 AQ2B 3P025MSS 30379 AQ2B 4P025MSS 30406 180 AQ2C 3P180LSS 30460 - -
32 AQ2B 3P032MSS 30380 AQ2B 4P032MSS 30407 200 AQ2C 3P200LSS 30461 - -
50kA 3SM8-100M S 40 AQ2B 3P040MSS 30381 AQ2B 4P040MSS 30408 225 AQ2C 3P225LSS 30462 - -
50 AQ2B 3P050MSS 30382 AQ2B 4P050MSS 30409 100 AQ2C 3P100LFS 30463 - -
63 AQ2B 3P063MSS 30383 AQ2B 4P063MSS 30410 125 AQ2C 3P125LFS 30464 - -
80 AQ2B 3P080MSS 30384 AQ2B 4P080MSS 30411 140 AQ2C 3P140LFS 30465 - -
100 AQ2B 3P100MSS 30385 AQ2B 4P100MSS 30412 F 160 AQ2C 3P160LFS 30466 - -
16 AQ2B 3P016MFS 30386 AQ2B 4P016MFS 30413 180 AQ2C 3P180LFS 30467 - -
20 AQ2B 3P020MFS 30387 AQ2B 4P020MFS 30414 200 AQ2C 3P200LFS 30468 - -
25 AQ2B 3P025MFS 30388 AQ2B 4P025MFS 30415 225 AQ2C 3P225LFS 30469 - -
32 AQ2B 3P032MFS 30389 AQ2B 4P032MFS 30416 100 AQ2C 3P100MRS 30470 AQ2C 4P100MRS 30491
F 40 AQ2B 3P040MFS 30390 AQ2B 4P040MFS 30417 125 AQ2C 3P125MRS 30471 AQ2C 4P125MRS 30492
50 AQ2B 3P050MFS 30391 AQ2B 4P050MFS 30418 140 AQ2C 3P140MRS 30472 AQ2C 4P140MRS 30493
63 AQ2B 3P063MFS 30392 AQ2B 4P063MFS 30419 R 160 AQ2C 3P160MRS 30473 AQ2C 4P160MRS 30494
80 AQ2B 3P080MFS 30393 AQ2B 4P080MFS 30420 180 AQ2C 3P180MRS 30474 AQ2C 4P180MRS 30495
100 AQ2B 3P100MFS 30394 AQ2B 4P100MFS 30421 200 AQ2C 3P200MRS 30475 AQ2C 4P200MRS 30496
225 AQ2C 3P225MRS 30476 AQ2C 4P225MRS 30497
100 AQ2C 3P100MSS 30477 AQ2C 4P100MSS 30498
125 AQ2C 3P125MSS 30478 AQ2C 4P125MSS 30499
140 AQ2C 3P140MSS 30479 AQ2C 4P140MSS 30500
50kA 3SM8-225M S 160 AQ2C 3P160MSS 30480 AQ2C 4P160MSS 30501
180 AQ2C 3P180MSS 30481 AQ2C 4P180MSS 30502
200 AQ2C 3P200MSS 30482 AQ2C 4P200MSS 30503
225 AQ2C 3P225MSS 30483 AQ2C 4P225MSS 30504
100 AQ2C 3P100MFS 30484 AQ2C 4P100MFS 30505
125 AQ2C 3P125MFS 30485 AQ2C 4P125MFS 30506
140 AQ2C 3P140MFS 30486 AQ2C 4P140MFS 30507
F 160 AQ2C 3P160MFS 30487 AQ2C 4P160MFS 30508
180 AQ2C 3P180MFS 30488 AQ2C 4P180MFS 30509
200 AQ2C 3P200MFS 30489 AQ2C 4P200MFS 30510
225 AQ2C 3P225MFS 30490 AQ2C 4P225MFS 30511

146 www.sassin.com www.sassin.com 147


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ2 CB Class Series 3SAQ2 CB Class

For power distribution (Separate type) For power distribution (Separate type)
Frame Icn MCCB Rated current 3P 4P Frame Icn MCCB Rated current 3P 4P
specification
Type specification
Type
at 400V AC (A) Type code Order code Type code Order code at 400V AC (A) Type code Order code Type code Order code
3SAQ2-225 100 AQ2C 3P100HRS 30512 - - 3SAQ2-630 400 AQ2E 3P400LRS 30593 - -
125 AQ2C 3P125HRS 30513 - - R 500 AQ2E 3P500LRS 30594 - -
140 AQ2C 3P140HRS 30514 - - 630 AQ2E 3P630LRS 30595 - -
R 160 AQ2C 3P160HRS 30515 - - 400 AQ2E 3P400LSS 30596 - -
180 AQ2C 3P180HRS 30516 - - 50kA 3SM8-630L S 500 AQ2E 3P500LSS 30597 - -
200 AQ2C 3P200HRS 30517 - - 630 AQ2E 3P630LSS 30598 - -
225 AQ2C 3P225HRS 30518 - - 400 AQ2E 3P400LFS 30599 - -
100 AQ2C 3P100HSS 30519 - - F 500 AQ2E 3P500LFS 30600 - -
125 AQ2C 3P125HSS 30520 - - 630 AQ2E 3P630LFS 30601 - -
140 AQ2C 3P140HSS 30521 - - 400 AQ2E 3P400MRS 30602 AQ2E 4P400MRS 30611
85kA 3SM8-225H S 160 AQ2C 3P160HSS 30522 - - R 500 AQ2E 3P500MRS 30603 AQ2E 4P500MRS 30612
180 AQ2C 3P180HSS 30523 - - 630 AQ2E 3P630MRS 30604 AQ2E 4P630MRS 30613
200 AQ2C 3P200HSS 30524 - - 400 AQ2E 3P400MSS 30605 AQ2E 4P400MSS 30614
225 AQ2C 3P225HSS 30525 - - 65kA 3SM8-630M S 500 AQ2E 3P500MSS 30606 AQ2E 4P500MSS 30615
100 AQ2C 3P100HFS 30526 - - 630 AQ2E 3P630MSS 30607 AQ2E 4P630MSS 30616
125 AQ2C 3P125HFS 30527 - - 400 AQ2E 3P400MFS 30608 AQ2E 4P400MFS 30617
140 AQ2C 3P140HFS 30528 - - F 500 AQ2E 3P500MFS 30609 AQ2E 4P500MFS 30618
F 160 AQ2C 3P160HFS 30529 - - 630 AQ2E 3P630MFS 30610 AQ2E 4P630MFS 30619
180 AQ2C 3P180HFS 30530 - - 400 AQ2E 3P400HRS 30620 - -
200 AQ2C 3P200HFS 30531 - - R 500 AQ2E 3P500HRS 30621 - -
Power Distribution Electrics

Power Distribution Electrics


225 AQ2C 3P225HFS 30532 - - 630 AQ2E 3P630HRS 30622 - -
3SAQ2-400 225 AQ2D 3P225LRS 30533 - - 400 AQ2E 3P400HSS 30623 - -
250 AQ2D 3P250LRS 30534 - - 100kA 3SM8-630H S 500 AQ2E 3P500HSS 30624 - -
R 315 AQ2D 3P315LRS 30535 - - 630 AQ2E 3P630HSS 30625 - -
350 AQ2D 3P250LRS 30536 - - 400 AQ2E 3P400HFS 30626 - -
400 AQ2D 3P400LRS 30537 - - F 500 AQ2E 3P500HFS 30627 - -
225 AQ2D 3P225LSS 30538 - - 630 AQ2E 3P630HFS 30628 - -
250 AQ2D 3P250LSS 30539 - - 3SAQ2-800 630 AQ2F 3P630MRS 30629 - -
50kA 3SM8-400L S 315 AQ2D 3P315LSS 30540 - - R 700 AQ2F 3P700MRS 30630 - -
350 AQ2D 3P250LSS 30541 - - 800 AQ2F 3P800MRS 30631 - -
400 AQ2D 3P400LSS 30542 - - 630 AQ2F 3P630MSS 30632 - -
225 AQ2D 3P225LFS 30543 - - 75kA 3SM8-630M S 700 AQ2F 3P700MSS 30633 - -
250 AQ2D 3P250LFS 30544 - - 800 AQ2F 3P800MSS 30634 - -
F 315 AQ2D 3P315LFS 30545 - - 630 AQ2F 3P630MFS 30635 - -
350 AQ2D 3P250LFS 30546 - - F 700 AQ2F 3P700MFS 30636 - -
400 AQ2D 3P400LFS 30547 - - 800 AQ2F 3P800MFS 30637 - -
225 AQ2D 3P225MRS 30548 AQ2D 4P225MRS 30563 630 AQ2F 3P630HRS 30647 - -
250 AQ2D 3P250MRS 30549 AQ2D 4P250MRS 30564 R 700 AQ2F 3P700HRS 30648 - -
R 315 AQ2D 3P315MRS 30550 AQ2D 4P315MRS 30565 800 AQ2F 3P800HRS 30649 - -
350 AQ2D 3P250MRS 30551 AQ2D 4P250MRS 30566 630 AQ2F 3P630HSS 30650 - -
400 AQ2D 3P400MRS 30552 AQ2D 4P400MRS 30567 100kA 3SM8-630H S 700 AQ2F 3P700HSS 30651 - -
225 AQ2D 3P225MSS 30553 AQ2D 4P225MSS 30568 800 AQ2F 3P800HSS 30652 - -
250 AQ2D 3P250MSS 30554 AQ2D 4P250MSS 30569 630 AQ2F 3P630HFS 30653 - -
65kA 3SM8-400M S 315 AQ2D 3P315MSS 30555 AQ2D 4P315MSS 30570 F 700 AQ2F 3P700HFS 30654 - -
350 AQ2D 3P250MSS 30556 AQ2D 4P250MSS 30571 800 AQ2F 3P800HFS 30655 - -
400 AQ2D 3P400MSS 30557 AQ2D 4P400MSS 30572
225 AQ2D 3P225MFS 30558 AQ2D 4P225MFS 30573
250 AQ2D 3P250MFS 30559 AQ2D 4P250MFS 30574
F 315 AQ2D 3P315MFS 30560 AQ2D 4P315MFS 30575 Utilization categories:
350 AQ2D 3P250MFS 30561 AQ2D 4P250MFS 30576
400 AQ2D 3P400MFS 30562 AQ2D 4P400MFS 30577
225 AQ2D 3P225HRS 30578 - - AC-33iB: for system loads including cage motor and
250 AQ2D 3P250HRS 30579 - -
resistive loads.
R 315 AQ2D 3P315HRS 30580 - -
350 AQ2D 3P250HRS 30581 - - AC-33B: for motor load or mixture load including motors,
400 AQ2D 3P400HRS 30582 - -
resistive load and 30% incandescent load .
225 AQ2D 3P225HSS 30583 - -
AQ2D 3P250HSS 30584 - - Standard: IEC 60947-6-1
250
100kA 3SM8-400H S 315 AQ2D 3P315HSS 30585 - -
350 AQ2D 3P250HSS 30586 - -
400 AQ2D 3P400HSS 30587 - -
225 AQ2D 3P225HFS 30588 - -
250 AQ2D 3P250HFS 30589 - -
F 315 AQ2D 3P315HFS 30590 - -
350 AQ2D 3P250HFS 30591 - -
400 AQ2D 3P400HFS 30592 - -

148 www.sassin.com www.sassin.com 149


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ3 PC Class Series 3SAQ3 PC Class

Features Instruction of type code

Small volume, convenient installation AQ3 2 S 250 M21L NG R


With the controller, the setting can transfer between the
manual and automatic change and automatic restore or Control model
automatic change without automatic restore
Swtiching model
Under voltage, over voltage, loss phase protection
Reliable and safe interlock, running parameter could be Controller type

adjusted Rated current


Rated voltage of 400V, rated current is 16A~5000A
Structure curve
Low malfunction, easy maintenance
Poles

Series code
Power Distribution Electrics

Power Distribution Electrics


Technical specifications

Type M2 M3
Standard IEC60947-6-1 IEC60947-6-1
Approval CE CE
Current frame (A) 63 125 250 500 800 1000 1250 1600 2000 3150 4000 5000
Rated operating current (A) 16, 32, 40, 63 80, 100, 125 160, 200, 225, 250 350, 400, 500 630 800 1000 1250 1600 2000 3150 4000 50 00
Number of poles (P) 2 3 4 2 3 3 2 3 4 2 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4
Operating current at AC 230V (A) 1.5 1.5 2 1.5 1.5 1.5 1.5 2 2.5 2.5 2.5 3.5 3 3 3 3 3 4 4 4 5 6 7 8 8 9
Rated operating voltage (VAC) 400 400 400 400 400 400 400 400 400 400 400
Rated control voltage (VAC) 230 230 230 230 230 230 230 230 230 230 230
Rated frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60
Rated limit short-circuit current (kA) 25 35 25 30 37.5 50 50 55 65 80 100 120
Short time withstand current (kA) 12.5 22 10 12 15 22 22 25 35 50 50 50
A supply-side Connect (ms) 55 55 55 60 100 115 115 115 140 180 200(190) 200(190)
conversion time Disconnect (ms) 20 20 20 25 30 25 25 25 25 30 30 35
B supply-side Connect (ms) 80 80 80 90 135 145 145 150 190 220 220(240) 230(270)
conversion time Disconnect (ms) 20 20 20 25 30 25 25 25 25 30 30 30(35)
With controller or not
Fully automatic generator -
Control mode R: Automatic transfer with automatic restore
S: Automatic transfer R: Automatic transfer with automatic restore
without automatic restore
Wiring Front connection Back connection
Breaking capacity 10 Ie connect, 8 Ie breaking, cosΦ=0.35 10 Ie connect, 8 Ie breaking, cosΦ=0.35
Use category AC-33B AC-33B
Applicable Mode NB: grid-grid NG: grid-generator NB: grid-grid NG: grid-generator
Electrical life (times) 2500 2500 2500 1000 1000 500 500 500 500 500 500
Mechanical life (times) 10000 10000 10000 3000 3000 2500 2500 2500 1500 1500 1500
Auxiliary switch capacity AC220V: 250A AC220V: 250A
Weight (kg) 6 6.5 7 5 5.5 5.5 6 8 10 11 14 18 33 42 39 49 40 51 47 51 115 135 152 192 207 265
Ambient temperature -5~40℃, max. 95 % humidity -5~40℃, max. 95 % humidity
Storage temperature -40~+75℃ -40~+75℃
Altitude (Max.) 2,000 2,000

150 www.sassin.com www.sassin.com 151


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ3 PC Class Series 3SAQ3 PC Class

Quick wiring diagram of M2 type J controller M2, M3 type built-in controller quick wiring diagram

Normal power Normal power


A power input A power input

Power A auxiliary
Power A auxiliary contact(See note 3)

Power A
contact(See note 2)
Power A
Power Distribution Electrics

Power Distribution Electrics


LED status display
Reserve power
Reserve power B power input
B power input Function key
(See note 1)

Power B
A1 A2 B1 B2 (See note 2)
Power B

N-phase
A1 A2 B1 B2 (See note 2)
Power B
auxiliary
contact
Power B Generator contact
auxiliary Note: N phase cannot be wrongly connected
contact
Load-side output

Load-side output

Auxiliary contact drawing Auxiliary contact drawing


Note: function key introduction
SET: can set when AB delay, BA delay, generator stop delay occurs
Normally closed contact Normally closed contact DOWN: the setting state is reduction, B-phase voltage can be displayed
automatically, B power can be manually switched to
Note: UP:the setting state is increase, A-phase voltage can be displayed automatically,
A1, A2 (The input signal of A power supply, AC220V) B power can be manually switched to
B1, B2 (The input signal of B power supply, AC220V) B-A: Auto / manual mode switch (enter manual mode when LED flashes) Press

Auxiliary contacts can be used to access the relevant instructions, the SET and B-A at the same time can set the reference voltage of A, B power
supply (LED displays UA, UB)
alarm or feedback signal, with specific uses depending on user's needs
A1, A2 (The input signal of A power supply, AC220V)
B1、B2 (The input signal of B power supply , AC220V)
G1, G2 is a contact switch used to turn on or off the generator battery
Normally open contact Normally open contact
Plate Plate Auxiliary contacts can be used to access the relevant instructions, alarm or
feedback signal, with specific uses depending on user's needs
Specific use please see ATS M2 built-in controller bar

152 www.sassin.com www.sassin.com 153


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ3 PC Class Series 3SAQ3 PC Class

Quick wiring diagram of M3 type J controller Quick wiring diagram for M3 type Ⅱwith external lcd

M3-125-500 type
A Power terminal

Power A

MQ2-M3 Dual Power


Automatic Transfer Switch

Note: N phase cannot


be wrongly connected
AN AR AS AT BN BR BS BT BT2 BT1 AT2 AT1 B2 B1 A2 A1 G2 G1 K2 K1 B-SW A-SW
B Power terminal
Power B
Power Distribution Electrics

Power Distribution Electrics


generator
contact
fire
protection
remote
Load output operation

BR Fire wire
Normal
power BN Null line

AT Fire wire
Reserve AS Fire wire
power AR Fire wire
AN Null line

Auxiliary contact drawing


Notice:
Note: NC for the vacancy
Controller type MQ2-J Type M2, M3 LED external controller, has aero-pin.
SET: has code 1, 2, 3D, they can set A low-volt-age (high voltage), B low voltage (high
common open contact voltage), OFF-A, OFF-B, B-OFF, generator stop, the delay of A error, B error and generator
Wiring instruction for MQ2-J controller starting clock for parameter.
DOWN/UP: it has the function of plus or minus in setting. AUTO/MAN: transfer between
automatic and manual; in the manual state, press the button for 3 seconds and in reference
voltage of power A and power B R,T,S phase (indicate by the each code).
STOP: cut off the power A and power B, transfer to OFF position, and it is in the wait state.
AON: Under the manual state, push AON button and Power A input. Under the automatic
and stop mode, push AON button, then it will indi-cate the phase R S T voltage of Power A.
BON: Under the manual state, push BON button and Power B input. Under the automatic
and stop mode, push BON button, then it will indi-cate the phase R S T voltage of Power B.
common close contact seesaw
A B auxiliary contact can be used in connecting the signal of indicate, alarm or feedback,
and that depends on the customer. The exactly using speci-fication is in the ATS M3
external LCD controller.
When there is something not coincident between the test voltage and factual voltage,
please carry on the setting operating for the reference voltage under the manual state.

154 www.sassin.com www.sassin.com 155


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ3 PC Class Series 3SAQ3 PC Class

Quick wiring diagram for M3 type Ⅱwith external lcd Outline and installation dimensions of M2, M3

M2, M3 20A~125A Safe distance from panel [S1 size: 300mm(400V), 60mm(690V)]

M3-630-2500 type

Note: N phase cannot


A B
be wrongly connected 2P 206 103
AN AR AS AT BN BR BS BT BT2 BT1 AT2 AT1 B2 B1 A2 A1 G2 G1 K2 K1 B-SW A-SW 3P 236 133
4P 266 163
Power Distribution Electrics

Power Distribution Electrics


generator
contact M2, M3 160A~250A Safe distance from panel [S1 size: 300mm(400V), 60mm(690V)]
fire
protection
remote
operation

A1 A2 B1 B2 AT1 AT2 BT1 BT2AN AR BN BR

A B
2P 221 113
3P 256 148
4P 292 183

① Operating circuit terminal ③ Auxiliary switch ⑤ Load side of main circuit terminal ⑦ ON / OFF optional monitor

② Manual handle entry ④ The main circuit terminal ⑥ The main circuit terminal of B power ⑧ Manual handle (removable)
of A power supply side supply side

M2, M3 350A~500A Safe distance from panel [S1 size: 300mm(400V), 60mm(690V)]
Auxiliary contact drawing
Notice:
Type M2, M3 LED external controller, has aero-pin.
SET: has code 1,2,3D, they can set A low-volt-age (high voltage), B low voltage(high
common open contact voltage), OFF-A, OFF-B, B-OFF, generator stop, the delay of A error, B error and generator
starting clock for parameter.
DOWN/UP: it has the function of plus or minus in setting. AUTO/MAN: transfer between
automatic and manual; in the manual state, press the button for 3 seconds and in
reference voltage of power A and power B R, T, S phase(indicate by the each code).
STOP: cut off the power A and power B, transfer to OFF position, and it is in the wait state.
AON: Under the manual state, push AON button and Power A input. Under the automatic
and stop mode, push AON button, then it will indi-cate the phase R S T voltage of Power A.
B ON Under the manual state, push BON button and Power B input. Under the automatic A B
and stop mode, push BON button, then it will indi-cate the phase R S T voltage of Power B. 2P 280 164
common close contact seesaw
A B auxiliary contact can be used in connecting the signal of indicate, alarm or feedback, 3P 340 226
and that depends on the customer. The exactly using speci- fication is in the ATS M3 4P 406 290

external LCD controller.


When there is something not coincident between the test voltage and factual voltage,
please carry on the setting operating for the reference voltage under the manual state.

156 www.sassin.com www.sassin.com 157


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ3 PC Class Series 3SAQ3 PC Class

Outline and installation dimensions of M2, M3 Product specifications distribution table

M3 630A~1600A Available Separate type


S1 size: 45mm(400V), 90mm(690V) Unavailable Unitary type
S2 size: 430mm(400V), 450mm(690V)
Rated voltage : Current
63 125 250 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
AC 400V frame A

Rated operating: Rated operating


16 32 40 63 80 100 125 160 200 225 250 350 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
AC 230V current A
Automatic 2P
grid-grid
transfer 3P
(NB)
with 4P

M2 Ⅰ LCD controller
automatic grid- 2P
restore generator 3P
A B C D E F G H (R) (NG) 4P
3P 4P 3P 4P Automatic 2P
grid-grid
630A 800A 405 470 375 440 83 65 60 117.5 10 15 transfer 3P
1000A 1250A 450 530 420 500 90 80 60 117.5 12 15 (NB)
without 4P

Split type
1600A 510 615 480 580 97.5 100 57 117.5 15 15 automatic grid- 2P
restore generator 3P
M3 2000A~4000A
Power Distribution Electrics

Power Distribution Electrics


(S) (NG) 4P
S1 size: 50mm(400V), 100mm(690V) 2P

M2 Ⅰ type controller
Automatic
grid-grid
S2 size: 560mm(400V), 600mm(690V) transfer 3P
with
(NB) 4P
automatic grid- 2P
restore generator 3P
(R) (NG) 4P
Automatic 2P
grid-grid
transfer 3P
with
(NB) 4P

M3 Ⅱ LCD controller
automatic grid- 2P
restore generator 3P
A B C D E F G H (R) (NG) 4P
3P 4P 3P 4P 2P
Automatic grid-grid
2000A 690 831 623 767 130 135 75 115 15 20

Split type
transfer 3P
2500A 690 831 623 767 130 135 75 115 20 20 (NB)
without 4P
3150A 915 1155 860 1100 135 240 75 115 20 20
automatic grid- 2P
4000A 915 1155 860 1100 135 240 75 115 20 20
restore generator 3P
(S) (NG) 4P
M2 M3

M3 Ⅱ type controller M2 I J-type controller


Automatic 2P
grid-grid
Two-stage, only two switch states: A power supply ⇄ B Three-stage, three switching states: A power supply ⇄ transfer 3P
(NB)
with 4P
power supply completely middle ⇄ B power supply. automatic grid- 2P
restore generator 3P
(R) (NG) 4P
M2 Ⅰ M3 Ⅱ
This automatic switch is instantly switch type (without This automatic switch has the basic three-body (intelligent Automatic 2P
grid-grid
transfer 3P
internal, external controller). If the switches are in the LCD controller with LCD) with automatic, manual swap (NB)
with 4P
maintenance or still in a damaged condition , the handle function , A, B three-phase four-wire voltage detection automatic grid- 2P
restore generator 3P
can be used for manual operation, the switching slow action function, overvoltage, undervoltage and phase protection,
(R) (NG) 4P
can be observed in order to identify the real point of failure. automatic processing of A, B switching power supply
M2 II built-in controller

Automatic 2P
function, fault automatically handling and remote start / grid-grid
transfer 3P
(NB)
Integrated

M2 Ⅱ stop generation machine functions. With the external with 4P


expansion interface, it can connect to over-current relay automatic grid- 2P
With built-in controller ,this automatic switch is of delayed
restore generator 3P
detection of switching function, automatic and manual to do the over-current protection and can display the (R) (NG) 4P
switching function, two-way real-time display function of voltage value of each segment, which is s high-performance
2P
M3 II J-type controller

input voltage. If the switches are in the maintenance or still intelligent controller. If the switches are in the maintenance Automatic grid-grid
transfer 3P
in a damaged condition , the handle can be used for manual or still in a damaged condition , the handle can be used for (NB)
with 4P
operation, the switching slow action can be observed in manual operation, the switching slow action can be automatic grid- 2P
restore generator 3P
order to identify the real point of failure. observed in order to identify the real point of failure.
(R) (NG) 4P

158 www.sassin.com www.sassin.com 159


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ3 PC Class Series 3SAQ3 PC Class

Selection and ordering data M2I-J controller (Separate type)


Rated 2P 3P 4P
Type
current (A) Type code Order code Type code Order code Type code Order code
16 AQ3 2S16M2IJ NBR 10917 AQ3 3S16M2IJ NBR 30797 AQ3 4S16M2IJ NBR 30811
M2I LCD controller (Split) 32 AQ3 2S32M2IJ NBR 10918 AQ3 3S32M2IJ NBR 30798 AQ3 4S32M2IJ NBR 30812
Rated 2P 3P 4P 40 AQ3 2S40M2IJ NBR 30788 AQ3 3S40M2IJ NBR 30799 AQ3 4S40M2IJ NBR 30813
Type
current (A) Type code Order code Type code Order code Type code Order code 63 AQ3 2S63M2IJ NBR 30789 AQ3 3S63M2IJ NBR 30800 AQ3 4S63M2IJ NBR 30814
16 AQ3 2S16M2IL NBR 10761 AQ3 3S16M2IL NBR 10772 AQ3 4S16M2IL NBR 10786 80 AQ3 2S80M2IJ NBR 30790 AQ3 3S80M2IJ NBR 30801 AQ3 4S80M2IJ NBR 30815
32 AQ3 2S32M2IL NBR 10762 AQ3 3S32M2IL NBR 10773 AQ3 4S32M2IL NBR 10787 100 AQ3 2S100M2IJ NBR 30791 AQ3 3S100M2IJ NBR 30802 AQ3 4S100M2IJ NBR 30816
40 AQ3 2S40M2IL NBR 10763 AQ3 3S40M2IL NBR 10774 AQ3 4S40M2IL NBR 10788 125 AQ3 2S125M2IJ NBR 30792 AQ3 3S125M2IJ NBR 30803 AQ3 4S125M2IJ NBR 30817
NBR
63 AQ3 2S63M2IL NBR 10764 AQ3 3S63M2IL NBR 10775 AQ3 4S63M2IL NBR 10789 160 AQ3 2S160M2IJ NBR 30793 AQ3 3S160M2IJ NBR 30804 AQ3 4S160M2IJ NBR 30818
80 AQ3 2S80M2IL NBR 10765 AQ3 3S80M2IL NBR 10776 AQ3 4S80M2IL NBR 10790 200 AQ3 2S200M2IJ NBR 30794 AQ3 3S200M2IJ NBR 30805 AQ3 4S200M2IJ NBR 30819
100 AQ3 2S100M2IL NBR 10766 AQ3 3S100M2IL NBR 10777 AQ3 4S100M2IL NBR 10791 225 AQ3 2S225M2IJ NBR 30795 AQ3 3S225M2IJ NBR 30806 AQ3 4S225M2IJ NBR 30820
125 AQ3 2S125M2IL NBR 10767 AQ3 3S125M2IL NBR 10778 AQ3 4S125M2IL NBR 10792 250 AQ3 2S250M2IJ NBR 30796 AQ3 3S250M2IJ NBR 30807 AQ3 4S250M2IJ NBR 30821
NBR - - AQ3 3S350M2IJ NBR 30808 AQ3 4S350M2IJ NBR 30822
160 AQ3 2S160M2IL NBR 10768 AQ3 3S160M2IL NBR 10779 AQ3 4S160M2IL NBR 10793 350
200 AQ3 2S200M2IL NBR 10769 AQ3 3S200M2IL NBR 10780 AQ3 4S200M2IL NBR 10794 400 - - AQ3 3S400M2IJ NBR 30809 AQ3 4S400M2IJ NBR 30823
225 AQ3 2S225M2IL NBR 10770 AQ3 3S225M2IL NBR 10781 AQ3 4S225M2IL NBR 10795 500 - - AQ3 3S500M2IJ NBR 30810 AQ3 4S500M2IJ NBR 30824
250 AQ3 2S250M2IL NBR 10771 AQ3 3S250M2IL NBR 10782 AQ3 4S250M2IL NBR 10796 16 AQ3 2S16M2IJ NGR 30825 AQ3 3S16M2IJ NGR 30836 AQ3 4S16M2IJ NGR 30850
350 - - AQ3 3S350M2IL NBR 10783 AQ3 4S350M2IL NBR 10797 32 AQ3 2S32M2IJ NGR 30826 AQ3 3S32M2IJ NGR 30837 AQ3 4S32M2IJ NGR 30851
400 - - AQ3 3S400M2IL NBR 10784 AQ3 4S400M2IL NBR 10798 40 AQ3 2S40M2IJ NGR 30827 AQ3 3S40M2IJ NGR 30838 AQ3 4S40M2IJ NGR 30852
500 - - AQ3 3S500M2IL NBR 10785 AQ3 4S500M2IL NBR 10799 63 AQ3 2S63M2IJ NGR 30828 AQ3 3S63M2IJ NGR 30839 AQ3 4S63M2IJ NGR 30853
16 AQ3 2S16M2IL NGR 10800 AQ3 3S16M2IL NGR 10811 AQ3 4S16M2IL NGR 10825 80 AQ3 2S80M2IJ NGR 30829 AQ3 3S80M2IJ NGR 30840 AQ3 4S80M2IJ NGR 30854
32 AQ3 2S32M2IL NGR 10801 AQ3 3S32M2IL NGR 10812 AQ3 4S32M2IL NGR 10826 100 AQ3 2S100M2IJ NGR 30830 AQ3 3S100M2IJ NGR 30841 AQ3 4S100M2IJ NGR 30855
Power Distribution Electrics

Power Distribution Electrics


40 AQ3 2S40M2IL NGR 10802 AQ3 3S40M2IL NGR 10813 AQ3 4S40M2IL NGR 10827 125 AQ3 2S125M2IJ NGR 30831 AQ3 3S125M2IJ NGR 30842 AQ3 4S125M2IJ NGR 30856
NGR
63 AQ3 2S63M2IL NGR 10803 AQ3 3S63M2IL NGR 10814 AQ3 4S63M2IL NGR 10828 160 AQ3 2S160M2IJ NGR 30832 AQ3 3S160M2IJ NGR 30843 AQ3 4S160M2IJ NGR 30857
80 AQ3 2S80M2IL NGR 10804 AQ3 3S80M2IL NGR 10815 AQ3 4S80M2IL NGR 10829 200 AQ3 2S200M2IJ NGR 30833 AQ3 3S200M2IJ NGR 30844 AQ3 4S200M2IJ NGR 30858
100 AQ3 2S100M2IL NGR 10805 AQ3 3S100M2IL NGR 10816 AQ3 4S100M2IL NGR 10830 225 AQ3 2S225M2IJ NGR 30834 AQ3 3S225M2IJ NGR 30845 AQ3 4S225M2IJ NGR 30859
125 AQ3 2S125M2IL NGR 10806 AQ3 3S125M2IL NGR 10817 AQ3 4S125M2IL NGR 10831 250 AQ3 2S250M2IJ NGR 30835 AQ3 3S250M2IJ NGR 30846 AQ3 4S250M2IJ NGR 30860
NGR - - AQ3 3S350M2IJ NGR 30847 AQ3 4S350M2IJ NGR 30861
160 AQ3 2S160M2IL NGR 10807 AQ3 3S160M2IL NGR 10818 AQ3 4S160M2IL NGR 10832 350
200 AQ3 2S200M2IL NGR 10808 AQ3 3S200M2IL NGR 10819 AQ3 4S200M2IL NGR 10833 400 - - AQ3 3S400M2IJ NGR 30848 AQ3 4S400M2IJ NGR 30862
225 AQ3 2S225M2IL NGR 10809 AQ3 3S225M2IL NGR 10820 AQ3 4S225M2IL NGR 10834 500 - - AQ3 3S500M2IJ NGR 30849 AQ3 4S500M2IJ NGR 30863
250 AQ3 2S250M2IL NGR 10810 AQ3 3S250M2IL NGR 10821 AQ3 4S250M2IL NGR 10835
350 - - AQ3 3S350M2IL NGR 10822 AQ3 4S350M2IL NGR 10836
400 - - AQ3 3S400M2IL NGR 10823 AQ3 4S400M2IL NGR 10837 M3II LCD controller (Separate type)
500 - - AQ3 3S500M2IL NGR 10824 AQ3 4S500M2IL NGR 10838 16 AQ3 2S16M3IIL NBR 30864 AQ3 3S16M3IIL NBR 30875 AQ3 4S16M3IIL NBR 30899
16 AQ3 2S16M2IL NBS 10839 AQ3 3S16M2IL NBS 10850 AQ3 4S16M2IL NBS 10864 32 AQ3 2S32M3IIL NBR 30865 AQ3 3S32M3IIL NBR 30876 AQ3 4S32M3IIL NBR 30900
32 AQ3 2S32M2IL NBS 10840 AQ3 3S32M2IL NBS 10851 AQ3 4S32M2IL NBS 10865 40 AQ3 2S40M3IIL NBR 30866 AQ3 3S40M3IIL NBR 30877 AQ3 4S40M3IIL NBR 30901
40 AQ3 2S40M2IL NBS 10841 AQ3 3S40M2IL NBS 10852 AQ3 4S40M2IL NBS 10866 63 AQ3 2S63M3IIL NBR 30867 AQ3 3S63M3IIL NBR 30878 AQ3 4S63M3IIL NBR 30902
63 AQ3 2S63M2IL NBS 10842 AQ3 3S63M2IL NBS 10853 AQ3 4S63M2IL NBS 10867 80 AQ3 2S80M3IIL NBR 30868 AQ3 3S80M3IIL NBR 30879 AQ3 4S80M3IIL NBR 30903
80 AQ3 2S80M2IL NBS 10843 AQ3 3S80M2IL NBS 10854 AQ3 4S80M2IL NBS 10868 100 AQ3 2S100M3IIL NBR 30869 AQ3 3S100M3IIL NBR 30880 AQ3 4S100M3IIL NBR 30904
100 AQ3 2S100M2IL NBS 10844 AQ3 3S100M2IL NBS 10855 AQ3 4S100M2IL NBS 10869 125 AQ3 2S125M3IIL NBR 30870 AQ3 3S125M3IIL NBR 30881 AQ3 4S125M3IIL NBR 30905
125 AQ3 2S125M2IL NBS 10845 AQ3 3S125M2IL NBS 10856 AQ3 4S125M2IL NBS 10870 160 AQ3 2S160M3IIL NBR 30871 AQ3 3S160M3IIL NBR 30882 AQ3 4S160M3IIL NBR 30906
NBS 30872
160 AQ3 2S160M2IL NBS 10846 AQ3 3S160M2IL NBS 10857 AQ3 4S160M2IL NBS 10871 200 AQ3 2S200M3IIL NBR AQ3 3S200M3IIL NBR 30883 AQ3 4S200M3IIL NBR 30907
200 AQ3 2S200M2IL NBS 10847 AQ3 3S200M2IL NBS 10858 AQ3 4S200M2IL NBS 10872 225 AQ3 2S225M3IIL NBR 30873 AQ3 3S225M3IIL NBR 30884 AQ3 4S225M3IIL NBR 30908
225 AQ3 2S225M2IL NBS 10848 AQ3 3S225M2IL NBS 10859 AQ3 4S225M2IL NBS 10873 250 AQ3 2S250M3IIL NBR 30874 AQ3 3S250M3IIL NBR 30885 AQ3 4S250M3IIL NBR 30909
250 AQ3 2S250M2IL NBS 10849 AQ3 3S250M2IL NBS 10860 AQ3 4S250M2IL NBS 10874 350 - - AQ3 3S350M3IIL NBR 30886 AQ3 4S350M3IIL NBR 30910
NBR
350 - - AQ3 3S350M2IL NBS 10861 AQ3 4S350M2IL NBS 10875 400 - - AQ3 3S400M3IIL NBR 30887 AQ3 4S400M3IIL NBR 30911
400 - - AQ3 3S400M2IL NBS 10862 AQ3 4S400M2IL NBS 10876 500 - - AQ3 3S500M3IIL NBR 30888 AQ3 4S500M3IIL NBR 30912
500 - - AQ3 3S500M2IL NBS 10863 AQ3 4S500M2IL NBS 10877 630 - - AQ3 3S630M3IIL NBR 30889 AQ3 4S630M3IIL NBR 30913
16 AQ3 2S16M2IL NGS 10878 AQ3 3S16M2IL NGS 10889 AQ3 4S16M2IL NGS 10903 800 - - AQ3 3S800M3IIL NBR 30890 AQ3 4S800M3IIL NBR 30914
32 AQ3 2S32M2IL NGS 10879 AQ3 3S32M2IL NGS 10890 AQ3 4S32M2IL NGS 10904 1000 - - AQ3 3S1000M3IIL NBR 30891 AQ3 4S1000M3IIL NBR 30915
40 AQ3 2S40M2IL NGS 10880 AQ3 3S40M2IL NGS 10891 AQ3 4S40M2IL NGS 10905 1250 - - AQ3 3S1250M3IIL NBR 30892 AQ3 4S1250M3IIL NBR 30916
63 AQ3 2S63M2IL NGS 10881 AQ3 3S63M2IL NGS 10892 AQ3 4S63M2IL NGS 10906 1600 - - AQ3 3S1600M3IIL NBR 30893 AQ3 4S1600M3IIL NBR 30917
80 AQ3 2S80M2IL NGS 10882 AQ3 3S80M2IL NGS 10893 AQ3 4S80M2IL NGS 10907 2000 - - AQ3 3S2000M3IIL NBR 30894 AQ3 4S2000M3IIL NBR 30918
100 AQ3 2S100M2IL NGS 10883 AQ3 3S100M2IL NGS 10894 AQ3 4S100M2IL NGS 10908 2500 - - AQ3 3S2500M3IIL NBR 30895 AQ3 4S2500M3IIL NBR 30919
125 AQ3 2S125M2IL NGS 10884 AQ3 3S125M2IL NGS 10895 AQ3 4S125M2IL NGS 10909 3150 - - AQ3 3S3150M3IIL NBR 30896 AQ3 4S3150M3IIL NBR 30920
NGS - - AQ3 3S4000M3IIL NBR AQ3 4S4000M3IIL NBR
160 AQ3 2S160M2IL NGS 10885 AQ3 3S160M2IL NGS 10896 AQ3 4S160M2IL NGS 10910 4000 30897 30921
200 AQ3 2S200M2IL NGS 10886 AQ3 3S200M2IL NGS 10897 AQ3 4S200M2IL NGS 10911 5000 - - AQ3 3S5000M3IIL NBR 30898 AQ3 4S5000M3IIL NBR 30922
225 AQ3 2S225M2IL NGS 10887 AQ3 3S225M2IL NGS 10898 AQ3 4S225M2IL NGS 10912
250 AQ3 2S250M2IL NGS 10888 AQ3 3S250M2IL NGS 10899 AQ3 4S250M2IL NGS 10913
350 - - AQ3 3S350M2IL NGS 10900 AQ3 4S350M2IL NGS 10914
400 - - AQ3 3S400M2IL NGS 10901 AQ3 4S400M2IL NGS 10915
500 - - AQ3 3S500M2IL NGS 10902 AQ3 4S500M2IL NGS 10916

160 www.sassin.com www.sassin.com 161


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ3 PC Class Series 3SAQ3 PC Class

M3II LCD controller (Separate type) M3II LCD controller ( Separate type )
Rated 2P 3P 4P Rated 2P 3P 4P
Type Type
current (A) Type code Order code Type code Order code Type code Order code current (A) Type code Order code Type code Order code Type code Order code
16 AQ3 2S16M3IIL NGR 30923 AQ3 3S16M3IIL NGR 30934 AQ3 4S16M3IIL NGR 30958 16 AQ3 2S16M3IIL NGS 31041 AQ3 3S16M3IIL NGS 31052 AQ3 4S16M3IIL NGS 31076
32 AQ3 2S32M3IIL NGR 30924 AQ3 3S32M3IIL NGR 30935 AQ3 4S32M3IIL NGR 30959 32 AQ3 2S32M3IIL NGS 31042 AQ3 3S32M3IIL NGS 31053 AQ3 4S32M3IIL NGS 31077
40 AQ3 2S40M3IIL NGR 30925 AQ3 3S40M3IIL NGR 30936 AQ3 4S40M3IIL NGR 30960 40 AQ3 2S40M3IIL NGS 31043 AQ3 3S40M3IIL NGS 31054 AQ3 4S40M3IIL NGS 31078
63 AQ3 2S63M3IIL NGR 30926 AQ3 3S63M3IIL NGR 30937 AQ3 4S63M3IIL NGR 30961 63 AQ3 2S63M3IIL NGS 31044 AQ3 3S63M3IIL NGS 31055 AQ3 4S63M3IIL NGS 31079
80 AQ3 2S80M3IIL NGR 30927 AQ3 3S80M3IIL NGR 30938 AQ3 4S80M3IIL NGR 30962 80 AQ3 2S80M3IIL NGS 31045 AQ3 3S80M3IIL NGS 31056 AQ3 4S80M3IIL NGS 31080
100 AQ3 2S100M3IIL NGR 30928 AQ3 3S100M3IIL NGR 30939 AQ3 4S100M3IIL NGR 30963 100 AQ3 2S100M3IIL NGS 31046 AQ3 3S100M3IIL NGS 31057 AQ3 4S100M3IIL NGS 31081
125 AQ3 2S125M3IIL NGR 30929 AQ3 3S125M3IIL NGR 30940 AQ3 4S125M3IIL NGR 30964 125 AQ3 2S125M3IIL NGS 31047 AQ3 3S125M3IIL NGS 31058 AQ3 4S125M3IIL NGS 31082
160 AQ3 2S160M3IIL NGR 30930 AQ3 3S160M3IIL NGR 30941 AQ3 4S160M3IIL NGR 30965 160 AQ3 2S160M3IIL NGS 31048 AQ3 3S160M3IIL NGS 31059 AQ3 4S160M3IIL NGS 31083
200 AQ3 2S200M3IIL NGR 30931 AQ3 3S200M3IIL NGR 30942 AQ3 4S200M3IIL NGR 30966 200 AQ3 2S200M3IIL NGS 31049 AQ3 3S200M3IIL NGS 31060 AQ3 4S200M3IIL NGS 31084
225 AQ3 2S225M3IIL NGR 30932 AQ3 3S225M3IIL NGR 30943 AQ3 4S225M3IIL NGR 30967 225 AQ3 2S225M3IIL NGS 31050 AQ3 3S225M3IIL NGS 31061 AQ3 4S225M3IIL NGS 31085
250 AQ3 2S250M3IIL NGR 30933 AQ3 3S250M3IIL NGR 30944 AQ3 4S250M3IIL NGR 30968 250 AQ3 2S250M3IIL NGS 31051 AQ3 3S250M3IIL NGS 31062 AQ3 4S250M3IIL NGS 31086
350 - - AQ3 3S350M3IIL NGR 30945 AQ3 4S350M3IIL NGR 30969 350 - - AQ3 3S350M3IIL NGS 31063 AQ3 4S350M3IIL NGS 31087
NGR NGS
400 - - AQ3 3S400M3IIL NGR 30946 AQ3 4S400M3IIL NGR 30970 400 - - AQ3 3S400M3IIL NGS 31064 AQ3 4S400M3IIL NGS 31088
500 - - AQ3 3S500M3IIL NGR 30947 AQ3 4S500M3IIL NGR 30971 500 - - AQ3 3S500M3IIL NGS 31065 AQ3 4S500M3IIL NGS 31089
630 - - AQ3 3S630M3IIL NGR 30948 AQ3 4S630M3IIL NGR 30972 630 - - AQ3 3S630M3IIL NGS 31066 AQ3 4S630M3IIL NGS 31090
800 - - AQ3 3S800M3IIL NGR 30949 AQ3 4S800M3IIL NGR 30973 800 - - AQ3 3S800M3IIL NGS 31067 AQ3 4S800M3IIL NGS 31091
1000 - - AQ3 3S1000M3IIL NGR 30950 AQ3 4S1000M3IIL NGR 30974 1000 - - AQ3 3S1000M3IIL NGS 31068 AQ3 4S1000M3IIL NGS 31092
1250 - - AQ3 3S1250M3IIL NGR 30951 AQ3 4S1250M3IIL NGR 30975 1250 - - AQ3 3S1250M3IIL NGS 31069 AQ3 4S1250M3IIL NGS 31093
1600 - - AQ3 3S1600M3IIL NGR 30952 AQ3 4S1600M3IIL NGR 30976 1600 - - AQ3 3S1600M3IIL NGS 31070 AQ3 4S1600M3IIL NGS 31094
2000 - - AQ3 3S2000M3IIL NGR 30953 AQ3 4S2000M3IIL NGR 30977 2000 - - AQ3 3S2000M3IIL NGS 31071 AQ3 4S2000M3IIL NGS 31095
Power Distribution Electrics

Power Distribution Electrics


2500 - - AQ3 3S2500M3IIL NGR 30954 AQ3 4S2500M3IIL NGR 30978 2500 - - AQ3 3S2500M3IIL NGS 31072 AQ3 4S2500M3IIL NGS 31096
3150 - - AQ3 3S3150M3IIL NGR 30955 AQ3 4S3150M3IIL NGR 30979 3150 - - AQ3 3S3150M3IIL NGS 31073 AQ3 4S3150M3IIL NGS 31097
4000 - - AQ3 3S4000M3IIL NGR 30956 AQ3 4S4000M3IIL NGR 30980 4000 - - AQ3 3S4000M3IIL NGS 31074 AQ3 4S4000M3IIL NGS 31098
5000 - - AQ3 3S5000M3IIL NGR 30957 AQ3 4S5000M3IIL NGR 30981 5000 - - AQ3 3S5000M3IIL NGS 31075 AQ3 4S5000M3IIL NGS 31099
16 AQ3 2S16M3IIL NBS 30982 AQ3 3S16M3IIL NBS 30993 AQ3 4S16M3IIL NBS 31017
32 AQ3 2S32M3IIL NBS 30983 AQ3 3S32M3IIL NBS 30994 AQ3 4S32M3IIL NBS 31018
40 AQ3 2S40M3IIL NBS 30984 AQ3 3S40M3IIL NBS 30995 AQ3 4S40M3IIL NBS 31019 M3II-J controller ( Separate type )
63 AQ3 2S63M3IIL NBS 30985 AQ3 3S63M3IIL NBS 30996 AQ3 4S63M3IIL NBS 31020 16 AQ3 2S16M3IIJ NBR 31100 AQ3 3S16M3IIJ NBR 31111 AQ3 4S16M3IIJ NBR 31135
80 AQ3 2S80M3IIL NBS 30986 AQ3 3S80M3IIL NBS 30997 AQ3 4S80M3IIL NBS 31021 32 AQ3 2S32M3IIJ NBR 31101 AQ3 3S32M3IIJ NBR 31112 AQ3 4S32M3IIJ NBR 31136
100 AQ3 2S100M3IIL NBS 30987 AQ3 3S100M3IIL NBS 30998 AQ3 4S100M3IIL NBS 31022 40 AQ3 2S40M3IIJ NBR 31102 AQ3 3S40M3IIJ NBR 31113 AQ3 4S40M3IIJ NBR 31137
125 AQ3 2S125M3IIL NBS 30988 AQ3 3S125M3IIL NBS 30999 AQ3 4S125M3IIL NBS 31023 63 AQ3 2S63M3IIJ NBR 31103 AQ3 3S63M3IIJ NBR 31114 AQ3 4S63M3IIJ NBR 31138
160 AQ3 2S160M3IIL NBS 30989 AQ3 3S160M3IIL NBS 31000 AQ3 4S160M3IIL NBS 31024 80 AQ3 2S80M3IIJ NBR 31104 AQ3 3S80M3IIJ NBR 31115 AQ3 4S80M3IIJ NBR 31139
200 AQ3 2S200M3IIL NBS 30990 AQ3 3S200M3IIL NBS 31001 AQ3 4S200M3IIL NBS 31025 100 AQ3 2S100M3IIJ NBR 31105 AQ3 3S100M3IIJ NBR 31116 AQ3 4S100M3IIJ NBR 31140
225 AQ3 2S225M3IIL NBS 30991 AQ3 3S225M3IIL NBS 31002 AQ3 4S225M3IIL NBS 31026 125 AQ3 2S125M3IIJ NBR 31106 AQ3 3S125M3IIJ NBR 31117 AQ3 4S125M3IIJ NBR 31141
250 AQ3 2S250M3IIL NBS 30992 AQ3 3S250M3IIL NBS 31003 AQ3 4S250M3IIL NBS 31027 160 AQ3 2S160M3IIJ NBR 31107 AQ3 3S160M3IIJ NBR 31118 AQ3 4S160M3IIJ NBR 31142
350 - - AQ3 3S350M3IIL NBS 31004 AQ3 4S350M3IIL NBS 31028 200 AQ3 2S200M3IIJ NBR 31108 AQ3 3S200M3IIJ NBR 31119 AQ3 4S200M3IIJ NBR 31143
NBS
400 - - AQ3 3S400M3IIL NBS 31005 AQ3 4S400M3IIL NBS 31029 225 AQ3 2S225M3IIJ NBR 31109 AQ3 3S225M3IIJ NBR 31120 AQ3 4S225M3IIJ NBR 31144
500 - - AQ3 3S500M3IIL NBS 31006 AQ3 4S500M3IIL NBS 31030 250 AQ3 2S250M3IIJ NBR 31110 AQ3 3S250M3IIJ NBR 31121 AQ3 4S250M3IIJ NBR 31145
630 - - AQ3 3S630M3IIL NBS 31007 AQ3 4S630M3IIL NBS 31031 350 - - AQ3 3S350M3IIJ NBR 31122 AQ3 4S350M3IIJ NBR 31146
NBR
800 - - AQ3 3S800M3IIL NBS 31008 AQ3 4S800M3IIL NBS 31032 400 - - AQ3 3S400M3IIJ NBR 31123 AQ3 4S400M3IIJ NBR 31147
1000 - - AQ3 3S1000M3IIL NBS 31009 AQ3 4S1000M3IIL NBS 31033 500 - - AQ3 3S500M3IIJ NBR 31124 AQ3 4S500M3IIJ NBR 31148
1250 - - AQ3 3S1250M3IIL NBS 31010 AQ3 4S1250M3IIL NBS 31034 630 - - AQ3 3S630M3IIJ NBR 31125 AQ3 4S630M3IIJ NBR 31149
1600 - - AQ3 3S1600M3IIL NBS 31011 AQ3 4S1600M3IIL NBS 31035 800 - - AQ3 3S800M3IIJ NBR 31126 AQ3 4S800M3IIJ NBR 31150
2000 - - AQ3 3S2000M3IIL NBS 31012 AQ3 4S2000M3IIL NBS 31036 1000 - - AQ3 3S1000M3IIJ NBR 31127 AQ3 4S1000M3IIJ NBR 31151
2500 - - AQ3 3S2500M3IIL NBS 31013 AQ3 4S2500M3IIL NBS 31037 1250 - - AQ3 3S1250M3IIJ NBR 31128 AQ3 4S1250M3IIJ NBR 31152
3150 - - AQ3 3S3150M3IIL NBS 31014 AQ3 4S3150M3IIL NBS 31038 1600 - - AQ3 3S1600M3IIJ NBR 31129 AQ3 4S1600M3IIJ NBR 31153
4000 - - AQ3 3S4000M3IIL NBS 31015 AQ3 4S4000M3IIL NBS 31039 2000 - - AQ3 3S2000M3IIJ NBR 31130 AQ3 4S2000M3IIJ NBR 31154
5000 - - AQ3 3S5000M3IIL NBS 31016 AQ3 4S5000M3IIL NBS 31040 2500 - - AQ3 3S2500M3IIJ NBR 31131 AQ3 4S2500M3IIJ NBR 31155
3150 - - AQ3 3S3150M3IIJ NBR 31132 AQ3 4S3150M3IIJ NBR 31156
4000 - - AQ3 3S4000M3IIJ NBR 31133 AQ3 4S4000M3IIJ NBR 31157
5000 - - AQ3 3S5000M3IIJ NBR 31134 AQ3 4S5000M3IIJ NBR 31158

162 www.sassin.com www.sassin.com 163


Automatic Transfer Switches Automatic Transfer Switches
Series 3SAQ3 PC Class Series 3SAQ3 PC Class

M3II-J controller ( Separate type ) M2I built-in controller (Unitary type)


Rated 2P 3P 4P Rated 2P 3P 4P
Type Type
current (A) Type code Order code Type code Order code Type code Order code current (A) Type code Order code Type code Order code Type code Order code
16 AQ3 2S16M3IIJ NGR 31159 AQ3 3S16M3IIJ NGR 31170 AQ3 4S16M3IIJ NGR 31194 16 AQ3 2U16M2IIB NGR 31323 AQ3 3U16M2IIB NGR 31334 AQ3 4U16M2IIB NGR 31348
32 AQ3 2S32M3IIJ NGR 31160 AQ3 3S32M3IIJ NGR 31171 AQ3 4S32M3IIJ NGR 31195 32 AQ3 2U32M2IIB NGR 31324 AQ3 3U32M2IIB NGR 31335 AQ3 4U32M2IIB NGR 31349
40 AQ3 2S40M3IIJ NGR 31161 AQ3 3S40M3IIJ NGR 31172 AQ3 4S40M3IIJ NGR 31196 40 AQ3 2U40M2IIB NGR 31325 AQ3 3U40M2IIB NGR 31336 AQ3 4U40M2IIB NGR 31350
63 AQ3 2S63M3IIJ NGR 31162 AQ3 3S63M3IIJ NGR 31173 AQ3 4S63M3IIJ NGR 31197 63 AQ3 2U63M2IIB NGR 31326 AQ3 3U63M2IIB NGR 31337 AQ3 4U63M2IIB NGR 31351
80 AQ3 2S80M3IIJ NGR 31163 AQ3 3S80M3IIJ NGR 31174 AQ3 4S80M3IIJ NGR 31198 80 AQ3 2U80M2IIB NGR 31327 AQ3 3U80M2IIB NGR 31338 AQ3 4U80M2IIB NGR 31352
100 AQ3 2S100M3IIJ NGR 31164 AQ3 3S100M3IIJ NGR 31175 AQ3 4S100M3IIJ NGR 31199 100 AQ3 2U100M2IIB NGR 31328 AQ3 3U100M2IIB NGR 31339 AQ3 4U100M2IIB NGR 31353
125 AQ3 2S125M3IIJ NGR 31165 AQ3 3S125M3IIJ NGR 31176 AQ3 4S125M3IIJ NGR 31200 125 AQ3 2U125M2IIB NGR 31329 AQ3 3U125M2IIB NGR 31340 AQ3 4U125M2IIB NGR 31354
NGR
160 AQ3 2S160M3IIJ NGR 31166 AQ3 3S160M3IIJ NGR 31177 AQ3 4S160M3IIJ NGR 31201 160 AQ3 2U160M2IIB NGR 31330 AQ3 3U160M2IIB NGR 31341 AQ3 4U160M2IIB NGR 31355
200 AQ3 2S200M3IIJ NGR 31167 AQ3 3S200M3IIJ NGR 31178 AQ3 4S200M3IIJ NGR 31202 200 AQ3 2U200M2IIB NGR 31331 AQ3 3U200M2IIB NGR 31342 AQ3 4U200M2IIB NGR 31356
225 AQ3 2S225M3IIJ NGR 31168 AQ3 3S225M3IIJ NGR 31179 AQ3 4S225M3IIJ NGR 31203 225 AQ3 2U225M2IIB NGR 31332 AQ3 3U225M2IIB NGR 31343 AQ3 4U225M2IIB NGR 31357
250 AQ3 2S250M3IIJ NGR 31169 AQ3 3S250M3IIJ NGR 31180 AQ3 4S250M3IIJ NGR 31204 250 AQ3 2U250M2IIB NGR 31333 AQ3 3U250M2IIB NGR 31344 AQ3 4U250M2IIB NGR 31358
350 - - AQ3 3S350M3IIJ NGR 31181 AQ3 4S350M3IIJ NGR 31205 350 - - AQ3 3U350M2IIB NGR 31345 AQ3 4U350M2IIB NGR 31359
NGS
400 - - AQ3 3S400M3IIJ NGR 31182 AQ3 4S400M3IIJ NGR 31206 400 - - AQ3 3U400M2IIB NGR 31346 AQ3 4U400M2IIB NGR 31360
500 - - AQ3 3S500M3IIJ NGR 31183 AQ3 4S500M3IIJ NGR 31207 500 - - AQ3 3U500M2IIB NGR 31347 AQ3 4U500M2IIB NGR 31361
630 - - AQ3 3S630M3IIJ NGR 31184 AQ3 4S630M3IIJ NGR 31208
800 - - AQ3 3S800M3IIJ NGR 31185 AQ3 4S800M3IIJ NGR 31209
1000 - - AQ3 3S1000M3IIJ NGR 31186 AQ3 4S1000M3IIJ NGR 31210 M3II-J controller (Unitary type)
1250 - - AQ3 3S1250M3IIJ NGR 31187 AQ3 4S1250M3IIJ NGR 31211 16 AQ3 2U16M3IIJ NBR 31362 AQ3 3U16M3IIJ NBR 31373 AQ3 4U16M3IIJ NBR 31384
1600 - - AQ3 3S1600M3IIJ NGR 31188 AQ3 4S1600M3IIJ NGR 31212 32 AQ3 2U32M3IIJ NBR 31363 AQ3 3U32M3IIJ NBR 31374 AQ3 4U32M3IIJ NBR 31385
2000 - - AQ3 3S2000M3IIJ NGR 31189 AQ3 4S2000M3IIJ NGR 31213 40 AQ3 2U40M3IIJ NBR 31364 AQ3 3U40M3IIJ NBR 31375 AQ3 4U40M3IIJ NBR 31386
Power Distribution Electrics

Power Distribution Electrics


2500 - - AQ3 3S2500M3IIJ NGR 31190 AQ3 4S2500M3IIJ NGR 31214 63 AQ3 2U63M3IIJ NBR 31365 AQ3 3U63M3IIJ NBR 31376 AQ3 4U63M3IIJ NBR 31387
3150 - - AQ3 3S3150M3IIJ NGR 31191 AQ3 4S3150M3IIJ NGR 31215 80 AQ3 2U80M3IIJ NBR 31366 AQ3 3U80M3IIJ NBR 31377 AQ3 4U80M3IIJ NBR 31388
4000 - - AQ3 3S4000M3IIJ NGR 31192 AQ3 4S4000M3IIJ NGR 31216 NBR 100 AQ3 2U100M3IIJ NBR 31367 AQ3 3U100M3IIJ NBR 31378 AQ3 4U100M3IIJ NBR 31389
5000 - - AQ3 3S5000M3IIJ NGR 31193 AQ3 4S5000M3IIJ NGR 31217 125 AQ3 2U125M3IIJ NBR 31368 AQ3 3U125M3IIJ NBR 31379 AQ3 4U125M3IIJ NBR 31390
160 AQ3 2U160M3IIJ NBR 31369 AQ3 3U160M3IIJ NBR 31380 AQ3 4U160M3IIJ NBR 31391
200 AQ3 2U200M3IIJ NBR 31370 AQ3 3U200M3IIJ NBR 31381 AQ3 4U200M3IIJ NBR 31392
M2I-J controller (Unitary type) 225 AQ3 2U225M3IIJ NBR 31371 AQ3 3U225M3IIJ NBR 31382 AQ3 4U225M3IIJ NBR 31393
16 AQ3 2U16M2IJ NBR 31218 AQ3 3U16M2IJ NBR 31229 AQ3 4U16M2IJ NBR 31240 250 AQ3 2U250M3IIJ NBR 31372 AQ3 3U250M3IIJ NBR 31383 AQ3 4U250M3IIJ NBR 31394
32 AQ3 2U32M2IJ NBR 31219 AQ3 3U32M2IJ NBR 31230 AQ3 4U32M2IJ NBR 31241 16 AQ3 2U16M3IIJ NGR 31395 AQ3 3U16M3IIJ NGR 31406 AQ3 4U16M3IIJ NGR 31417
40 AQ3 2U40M2IJ NBR 31220 AQ3 3U40M2IJ NBR 31231 AQ3 4U40M2IJ NBR 31242 32 AQ3 2U32M3IIJ NGR 31396 AQ3 3U32M3IIJ NGR 31407 AQ3 4U32M3IIJ NGR 31418
63 AQ3 2U63M2IJ NBR 31221 AQ3 3U63M2IJ NBR 31232 AQ3 4U63M2IJ NBR 31243 40 AQ3 2U40M3IIJ NGR 31397 AQ3 3U40M3IIJ NGR 31408 AQ3 4U40M3IIJ NGR 31419
80 AQ3 2U80M2IJ NBR 31222 AQ3 3U80M2IJ NBR 31233 AQ3 4U80M2IJ NBR 31244 63 AQ3 2U63M3IIJ NGR 31398 AQ3 3U63M3IIJ NGR 31409 AQ3 4U63M3IIJ NGR 31420
NBR 100 AQ3 2U100M2IJ NBR 31223 AQ3 3U100M2IJ NBR 31234 AQ3 4U100M2IJ NBR 31245 80 AQ3 2U80M3IIJ NGR 31399 AQ3 3U80M3IIJ NGR 31410 AQ3 4U80M3IIJ NGR 31421
125 AQ3 2U125M2IJ NBR 31224 AQ3 3U125M2IJ NBR 31235 AQ3 4U125M2IJ NBR 31246 NGR 100 AQ3 2U100M3IIJ NGR 31400 AQ3 3U100M3IIJ NGR 31411 AQ3 4U100M3IIJ NGR 31422
160 AQ3 2U160M2IJ NBR 31225 AQ3 3U160M2IJ NBR 31236 AQ3 4U160M2IJ NBR 31247 125 AQ3 2U125M3IIJ NGR 31401 AQ3 3U125M3IIJ NGR 31412 AQ3 4U125M3IIJ NGR 31423
200 AQ3 2U200M2IJ NBR 31226 AQ3 3U200M2IJ NBR 31237 AQ3 4U200M2IJ NBR 31248 160 AQ3 2U160M3IIJ NGR 31402 AQ3 3U160M3IIJ NGR 31413 AQ3 4U160M3IIJ NGR 31424
225 AQ3 2U225M2IJ NBR 31227 AQ3 3U225M2IJ NBR 31238 AQ3 4U225M2IJ NBR 31249 200 AQ3 2U200M3IIJ NGR 31403 AQ3 3U200M3IIJ NGR 31414 AQ3 4U200M3IIJ NGR 31425
250 AQ3 2U250M2IJ NBR 31228 AQ3 3U250M2IJ NBR 31239 AQ3 4U250M2IJ NBR 31250 225 AQ3 2U225M3IIJ NGR 31404 AQ3 3U225M3IIJ NGR 31415 AQ3 4U225M3IIJ NGR 31426
16 AQ3 2U16M2IJ NGR 31251 AQ3 3U16M2IJ NGR 31262 AQ3 4U16M2IJ NGR 31273 250 AQ3 2U250M3IIJ NGR 31405 AQ3 3U250M3IIJ NGR 31416 AQ3 4U250M3IIJ NGR 31427
32 AQ3 2U32M2IJ NGR 31252 AQ3 3U32M2IJ NGR 31263 AQ3 4U32M2IJ NGR 31274
40 AQ3 2U40M2IJ NGR 31253 AQ3 3U40M2IJ NGR 31264 AQ3 4U40M2IJ NGR 31275
63 AQ3 2U63M2IJ NGR 31254 AQ3 3U63M2IJ NGR 31265 AQ3 4U63M2IJ NGR 31276
80 AQ3 2U80M2IJ NGR 31255 AQ3 3U80M2IJ NGR 31266 AQ3 4U80M2IJ NGR 31277 Utilization categories:
NGR 100 AQ3 2U100M2IJ NGR 31256 AQ3 3U100M2IJ NGR 31267 AQ3 4U100M2IJ NGR 31278
125 AQ3 2U125M2IJ NGR 31257 AQ3 3U125M2IJ NGR 31268 AQ3 4U125M2IJ NGR 31279
160 AQ3 2U160M2IJ NGR 31258 AQ3 3U160M2IJ NGR 31269 AQ3 4U160M2IJ NGR 31280 AC-33iB: for system loads including cage motor and
200 AQ3 2U200M2IJ NGR 31259 AQ3 3U200M2IJ NGR 31270 AQ3 4U200M2IJ NGR 31281
resistive loads.
225 AQ3 2U225M2IJ NGR 31260 AQ3 3U225M2IJ NGR 31271 AQ3 4U225M2IJ NGR 31282
250 AQ3 2U250M2IJ NGR 31261 AQ3 3U250M2IJ NGR 31272 AQ3 4U250M2IJ NGR 31283 AC-33B: for motor load or mixture load including motors,
resistive load and 30% incandescent load .

M2II built-in controller ( Unitary type ) Standard: IEC 60947-6-1


16 AQ3 2U16M2IIB NBR 31284 AQ3 3U16M2IIB NBR 31295 AQ3 4U16M2IIB NBR 31309
32 AQ3 2U32M2IIB NBR 31285 AQ3 3U32M2IIB NBR 31296 AQ3 4U32M2IIB NBR 31310
40 AQ3 2U40M2IIB NBR 31286 AQ3 3U40M2IIB NBR 31297 AQ3 4U40M2IIB NBR 31311
63 AQ3 2U63M2IIB NBR 31287 AQ3 3U63M2IIB NBR 31298 AQ3 4U63M2IIB NBR 31312
80 AQ3 2U80M2IIB NBR 31288 AQ3 3U80M2IIB NBR 31299 AQ3 4U80M2IIB NBR 31313
100 AQ3 2U100M2IIB NBR 31289 AQ3 3U100M2IIB NBR 31300 AQ3 4U100M2IIB NBR 31314
125 AQ3 2U125M2IIB NBR 31290 AQ3 3U125M2IIB NBR 31301 AQ3 4U125M2IIB NBR 31315
NBR
160 AQ3 2U160M2IIB NBR 31291 AQ3 3U160M2IIB NBR 31302 AQ3 4U160M2IIB NBR 31316
200 AQ3 2U200M2IIB NBR 31292 AQ3 3U200M2IIB NBR 31303 AQ3 4U200M2IIB NBR 31317
225 AQ3 2U225M2IIB NBR 31293 AQ3 3U225M2IIB NBR 31304 AQ3 4U225M2IIB NBR 31318
250 AQ3 2U250M2IIB NBR 31294 AQ3 3U250M2IIB NBR 31305 AQ3 4U250M2IIB NBR 31319
350 - - AQ3 3U350M2IIB NBR 31306 AQ3 4U350M2IIB NBR 31320
400 - - AQ3 3U400M2IIB NBR 31307 AQ3 4U400M2IIB NBR 31321
500 - - AQ3 3U500M2IIB NBR 31308 AQ3 4U500M2IIB NBR 31322

164 www.sassin.com www.sassin.com 165


Load Break Switches Load Break Switches
Series 3SGL Series 3SGL

Applications and functions Selection and ordering data

Number of poles Rated current


Making, breaking and disconnecting under load conditions In(A) Type Code Order Code
Hand in cabinet 3 125 GL125AIF3 31428
Providing safety isolation for any low voltage circuit
160 GL160AIF3 10919
250 GL250AIF3 10920
400 GL400AIF3 10921
Instruction of type code
630 GL630AIF3 10922
Hand outside cabinet 3 125 GL125AEF3 31430
160 GL160AEF3 10937
GL 125 A I F 3 250 GL250AEF3 10938
400 GL400AEF3 10939
630 GL630AEF3 10940
Poles : 3: 3P;4: 4P
Hand in cabinet 4 125 GL125AIF4 31429
Operation type 160 GL160AIF4 10928
250 GL250AIF4 10929
F: Front operation
400 GL400AIF4 10930
Handle type 630 GL630AIF4 10931
I: Internal handle Hand outside cabinet 4 125 GL125AEF4 31431
160 GL160AEF4 10946
E: External handle 250 GL250AEF4 10947
Operating voltage type poles 400 GL400AEF4 10948
Power Distribution Electrics

Power Distribution Electrics


630 GL630AEF4 10949
A: AC voltage
Conventional thermal current
125 Outline and installation dimensions

160
250 specification 3SGLXX 3SGL-XX/W Overall and mounting dimensions mm
Current A B C D E φL J D N P R U φX Y Z
400 J
N
J
N
D

C1 Y
125A/3 140 135 125 27 73 5.5 120 65 85 36 20 85 9 25 226 R R
T

630 ØX ΦL

S
160A/3 140 135 125 27 73 5.5 120 65 85 36 20 85 9 25 226

D
øL 0

Series code

G
B

K
125A/4 170 135 125 27 73 5.5 150 65 85 36 20 85 9 25 226 90°

160A/4 170 135 125 27 73 5.5 150 65 85 36 20 85 9 25 226 E


90° A C

Technical specifications 200A/3 180 170 138 35 86 5.5 160 90 115 50 25 110 11 25 236
250A/3 180 170 138 35 86 5.5 160 90 115 50 25 110 11 25 236 Installing underpan for panel mounting 3SGL-125~630

200A/4 230 170 138 35 86 5.5 210 90 115 50 25 110 11 25 236


Type 3SGL-125 3SGL-160 3SGL-250 3SGL-400 3SGL-630 250A/4 230 170 138 35 86 5.5 210 90 115 50 25 110 11 25 236 unit in mm
D1
Standard IEC60947-3 315A/3 230 240 169 50 113 7 210 140 145 65 32 160 11 37 276
Approval CE 400A/3 230 240 169 50 113 7 210 140 145 65 32 160 11 37 276
Conventional thermal current Ith(A) 125 160 250 400 630 630A/3 230 260 169 50 113 7 210 140 145 65 40 160 11 37 276
70
Rated voltage (V) 400 315A/4 290 240 169 50 113 7 270 140 145 65 32 160 11 37 276 Z
Rated insulation voltage(V) 800 400A/4 290 240 169 50 113 7 270 140 145 65 32 160 11 37 276 125A~630
Number of poles 3,4 3,4 3,4 3,4 3,4 630A/4 290 260 169 50 113 7 270 140 145 65 32 160 13 37 276
Extended handle

Rated frequency (Hz) 50/60 50/60 50/60 50/60 50/60


400V,AC22B 125 160 250 400 630
1000A~1600A Overall and Mounting Dimensions
690V,AC21B 125 160 250 315 500
J
400V,DC22 125 160 250 400 630
K N Y
690V,DC21 125 160 200 315 500 Installing underpan for 55
50 outside operated 32
172

8.5
Enlarged 81
Rated short-time with stand current Icw (kA ) for 1 S 10 10 12 20 25 2-ø12.5 t4.0

72
3-ø5.5
Rated making capability in AC23 400V (A) 1250 1250 2000 4000 4000

175

25
20
U
B

170
35

311
280
Rated breaking capability Icn in AC23 400V (A) 1000 1000 1600 2500 3200 8.5

18

16

62
ø9 4-ø13
Mechanical life (times) 10000 10000 8000 5500 5500 20 40 Mounting dimension of
ø30
120 140 12.5 35 Installing underpan
Enlarged
Degree of protection (operator side) IP20 A C externally mounted handle Z
for outside operating

Operation torque (Nm) 6.5 6.5 10 14.5 14.5 1000A~1600A Integrated handle 1000A 1250A~1600A 1000A~1600A Extended handle
Ambient temperature -5 to +40℃, max. 95 % humidity
Storage temperature -40 to +75℃ Type A B J N R T Y
Altitude( Max) 2000 3SGL-1000/3 378 312 353 185 60 8 48
3SGL-1000/4 498 312 473 249 60 8 48
3SGL-1250/3 378 356 353 185 80 8 48
3SGL-1250/4 498 356 473 249 80 8 48
3SGL-1600/3 378 356 353 185 80 10 49
3SGL-1600/4 498 356 473 249 80 10 49

166 www.sassin.com www.sassin.com 167


Fuse Combination Switches Fuse Combination Switches
Series 3SGLR Series 3SGLR

Applications and functions Selection and ordering data


Number of poles Rated current LV HRC Fuse
In(A) links(size) Type code Order code
Breaking or switching off on load
Hand in cabinet 3 160 00 GLR160AIT3 11010
Safety isolation and protection against over current for 250 1 GLR250AIT3 11011
any low voltage electrical circuit 400 2 GLR400AIT3 11012
630 3 GLR630AIT3 11013
Providing a guarantee of reliable breaking and protection
Hand outside cabinet 3 160 00 GLR160AET3 11021
from power distribution to motor protection 250 1 GLR250AET3 11022
400 2 GLR400AET3 11023
630 3 GLR630AET3 11024
Instruction of type code Hand in cabinet 4 160 00 GLR160AIT4 11014
250 1 GLR250AIT4 11015
400 2 GLR400AIT4 11016
GLR 160 A I F 3 630 3 GLR630AIT4 11017
Hand outside cabinet 4 160 00 GLR160AET4 11025
Poles 250 1 GLR250AET4 11026
400 2 GLR400AET4 11027
3: 3P
630 3 GLR630AET4 11028
4: 4P
Operation type
F: Front operation Outline and installation dimensions
Power Distribution Electrics

Power Distribution Electrics


Handle type
I: Internal handle
E: External handle
Specification Overall and Mounting Dimensions
Operating voltage type poles A B C D E F H I J L M N W P K
A: AC voltage 3SGLR-160/3 165 162 36 120 142 67.5 190 5.5 115 205~325 8 19 21 36 126
Conventional thermal current 3SGLR-160/4 202 162 36 120 142 67.5 190 5.5 115 205~325 8 19 21 36 126
160 3SGLR-250/3 240 195 60 160 166 91.5 210 5.5 145 205~325 10 19 21 60 126
3SGLR-250/4 300 195 60 160 166 91.5 210 5.5 145 205~325 10 19 21 60 126
250
3SGLR-400/3 280 205 66 170 176 122 210 5.5 145 205~325 10 25 21 66 126
400
3SGLR-400/4 346 205 66 170 176 122 210 5.5 145 205~325 10 25 21 66 126
630
3SGLR-630/3 346 300 250 250 268 39 350 φ9 190 330~440 12 72 37 80 190
Series code 3SGLR-630/4 426 300 250 250 268 39 350 φ9 190 330~440 12 72 37 80 190

Technical specifications
Integrated handle Extended handle
Type 3SGLR-160 3SGLR-250 3SGLR-400 3SGLR-630
Standard IEC60947-3 H
Approval CE
30 L
N
Conventional thermal current Ith(A) 160 250 400 630 setscrew Finger
Rated voltage (V) 400 Square axostyle
Rated insulation voltage(V) 690 800
Number of poles 3,4 3,4 3,4 3,4 setscrew
Rated frequency (HZ) 50/60 50/60 50/60 50/60
Associated fuse( SIZE) 00 1 2 3 Lock

K
Associated current (A)
400V,AC21B (A) 160 250 400 630
400V,AC22B (A) 160 250 400 630
690V,AC22B (A) 100 250 315 425
690V,AC22B (A) 100 250 315 425
A
230V,DC21 (A) 160 250 400 630 M C F W 50
230V,DC22 (A) 160 250 400 630
Φ30 50
440V,DC21 (A) 100 250 315 425 Φ30
440V,DC22 (A) 100 250 315 425 3-Φ5.5

50
Rated breaking capability Icn in AC23 401V (KA) 10 10 20 35
Mechanical life (times) 10000 8000 5500 5500
4-Φ4.5
D
B
E

Degree of protection (operator side)



Operation torque (Nm) 6.5 10 14.5 14.5 100-400A demension 630A dimension
90

Ambient temperature -5 to +40℃, max. 95 % humidity


on the panel
°

Storage temperature -40 to +75℃ on the panel


Altitude( Max) 2000 J P

168 www.sassin.com www.sassin.com 169


Fuse Disconnector Switches Fuse Disconnector Switches
Series 3SHR17 Series 3SHR17

Applications and functions Selection and ordering data


LV HRC fuse
Number of poles Rated current In(A)
links (Size) Type code Order code
Short circuit protection in the distribution and motor
circuit 160 00 HR1716030 11037
To be power switch, isolating switch, emergency switch
250 1 HR1725030 11038
Used in the distribution circuit and motor circuit
3P
400 2 HR1740030 11039
Instruction of type code
630 3 HR1763030 11040

HR17 160 3 0 160 00 HR1716040 11043

250 1 HR1725040 11044


4P
Micro-witch 400 2 HR1740040 11045
0: Without micro-switch
630 3 HR1763040 11046
Poles
3: 3P
Power Distribution Electrics

Power Distribution Electrics


Mounting dimensions
4: 4P

Conventional thermal current


C
160
250
400 ΦC
630

Series code

b
Technical specifications
a

B
Type 3SHR17-160 3SHR17-250 3SHR17-400 3SHR17-630 E E
Standard IEC60947-3
Approval CE
Conventional thermal current lth(A) 160 250 400 630
Rated insulation voltage(V) 800 800 800 800
Rated current (A) 160 250 400 630
Associated fuse (SIZE) 0 1 2 3
Number of poles 3,4 3,4 3,4 3,4
Rated frequency (HZ) 50/60 50/60 50/60 50/60
Rated operational voltage Ue(VAC) 690 690 690 690
Rated insulation voltage Ui (VAC) 800 800 800 800 A
Rated conditional short-circuit current
00/160 1/250 3/400 4/630 D
with fuses (size/A)
Rated breaking capacity at 500/690 V AC(KA) 50 50 50 50
AC-21B(690V) AC-21B(690V) AC-21B(690V) AC-21B(690V)
Utilization category AC-22B(500V) AC-22B(500V) AC-22B(500V) AC-22B(500V)
AC-23B(400V) AC-23B(400V) AC-23B(400V) AC-23B(400V)
725V 240A 725V 375A 725V 600A 725V 945A Overall size (mm) Mounting dementions (mm)
Rated making capacity (A) Type
525V 480A 525V 750A 525V 1200A 525V 1890A A B C D E a b c
420V 1600A 420V 2500A 420V 4000A 420V 6300A 3P 106 200 83 205 33 66 25 Φ7
3SHR17-160
725V 240A 725V 375A 725V 600A 725V 945A 4P 138 200 83 205 33 100 25 Φ7
Rated breaking capacity 525V 480A 525V 750A 525V 1200A 525V 1890A 3P 185 247 110 295 57 114 50 Φ 11
3SHR17-250
420V 1280A 420V 2000A 420V 3200A 420V 6300A 4P 242 247 110 295 57 172 50 Φ 11
Power consumption of fuse (W) 12 24 34 48 3P 210 290 125 340 65 130 50 Φ 11
Permissible ambient temperature 3SHR17-400
-5 ... +45 for operation, -45 ... +60 during storage 4P 276 290 125 340 65 195 50 Φ 11
Mechanical endurance ,operating cycles 1000 800 800 800 3P 256 300 145 360 81 162 50 Φ 11
Degree of protection (operator side) 3SHR17-630
IP20 4P 340 300 145 360 81 243 50 Φ11

170 www.sassin.com www.sassin.com 171


Low Voltage Fuses Low Voltage Fuses
Series RT16 Series RT16

Applications and functions Selection and ordering data

Maximum rated Rated Matched


Connecting and disconnecting circuits under load LV HRC fuse core Fuse type voltage (V) current In (A) fuse base Type code Order code

Protection against overloads and short circuits Blade Size 00C 500/660 10 RT16-00-B 10RT16G00C 24611
16 16RT16G00C 24612
Used for installation systems in non-residential, 20 20RT16G00C 24613
commercial and industrial buildings as well as in 25 25RT16G00C 24614
32 32RT16G00C 24615
systems of power supply companies. 24616
40 40RT16G00C
50 50RT16G00C 24617
63 63RT16G00C 24618
Instruction of type code
80 80RT16G00C 24619
100 100RT16G00C 24620
Blade Size 00 500/660 10 RT16-00-B 10RT16G00 24623
10 RT16 G 00C 16 16RT16G00 24624
20 20RT16G00 24625
Blade size 25 25RT16G00 24626
32 32RT16G00 24627
00C, 00, 0, 1, 2, 3, 4 40 40RT16G00 24628
Protection type 50 50RT16G00 24629
G: Circuit protection 63 63RT16G00 24630
80 80RT16G00 24631
Series code 100 100RT16G00 24632
Power Distribution Electrics

Power Distribution Electrics


Rated current 125 125RT16G00 24633
10, 16, 20, 25, 32, 40, 50, 63, 80, 100 (Size 00C) 160 160RT16G00 24634
Blade Size 0 500/660 10 RT16-0-B 10RT16G0 24635
10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160 (Size 00) 16 16RT16G0 24636
10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160 (Size 0) 20 20RT16G0 24637
25 25RT16G0 24638
63, 80, 100, 125, 160, 200, 225, 250 (Size 1) 32 32RT16G0 24639
125, 160, 200, 225, 250, 300, 315, 355, 400 (Size 2) 40 40RT16G0 24640
50 50RT16G0 24641
160, 200, 225, 250, 300, 315, 355, 400, 500, 630 (Size 3) 63 63RT16G0 24642
800, 1000 (Size 4) 80 80RT16G0 24643
100 100RT16G0 24644
125 125RT16G0 24645
Technical specifications 160 160RT16G0 24646
Blade Size 1 500/660 63 RT16-1-B 63RT16G1 24647
80 80RT16G1 24648
100 100RT16G1 24649
Size 00C 00 0 1 2 3 4 125 125RT16G1 24650
Standard IEC60269 160 160RT16G1 24651
200 200RT16G1 24652
Approvals SEMKO, CE
225 225RT16G1 24653
Frame current Inm(A) 160 160 160 250 400 630 1000 250 250RT16G1 24654
Blade Size 2 500/660 125 RT16-2-B 125RT15G2 24655
Rated current(A) 10,16,20,25 10,16,20,25 10,16,20,25 63,80,100 125,160,200 160,200,225, 800,100
160 160RT16G2 24656
32,40,50,63 32,40,50,63 32,40,50,63 125,160,200 225,250,300 250,300,315, 200 200RT16G2 24657
80,100 80,100,125 80,100,125,160 225,250 315,355,630 355,400,500,630 225 225RT16G2 24658
250 250RT16G2 24659
Rated voltage Un(V AC) 500/660 300 300RT16G2 24660
Rated frequency(Hz) 50/60 315 315RT16G2 24661
355 355RT16G2 24662
Rated breaking capacity (KA) 120 120 120 120 120 120 120
400 400RT16G2 24663
Ambient temperature -5 to +40 ℃ , max. 95 % humidity Blade Size 3 500/660 160 RT16-3-B 160RT16G3 24664
200 200RT16G3 24665
Storage temperature -40 ... +75℃
225 225RT16G3 24666
250 250RT16G3 24667
300 300RT16G3 24668
315 315RT16G3 24669
Selection and ordering data
355 355RT16G3 24670
400 400RT16G3 24671
Maximum rated Rated Matched
500 500RT16G3 24672
LV HRC fuse bases Fuse type voltage (V) current In (A) fuse base Type code Order code
630 630RT16G3 24673
Blade Size 00C 500 160 RT16G00C RT16-00-B 24679 Blade Size 4 500/660 800 RT16-4-B 800RT16G4 24675
Blade Size 00 500 160 RT16G00 RT16-00-B 24679 1000 1000RT16G4 24676
Blade Size 0 500 160 RT16G0 RT16-0-B 24680
Blade Size 1 500 250 RT16G1 RT16-1-B 24681
Blade Size 2 500 400 RT16G2 RT16-2-B 24682
Blade Size 3 500 630 RT16G3 RT16-3-B 24683
Blade Size 4 500 1000 RT16G4 RT16-4-B 24684

172 www.sassin.com www.sassin.com 173


Low Voltage Fuses Low Voltage Fuses
Series RT16 Series RT16

Outline and installation dimensions

0
10 -0.3 0
10 -0.3

0
10 -0.3

H
H

H
C

C
C
B B 6 B 6
6 A A D A D
D

Fig 1 Fig 2 Fig3

Carrier Fuse
Overall dimension
SASSIN Drawing A B C D H
RT16-00C Fig 1 78 49 15 21 52.5
RT16-00 Fig 2 78 49 15 29 56
RT16-0 Fig 2
Power Distribution Electrics

125 68 15 29 56

Power Distribution Electrics


RT16-1 Fig 3 135 68 20 48 60
RT16-2 Fig 3 150 68 26 60 70
RT16-3 Fig 3 150 68 32 67 82
RT16-4 Fig 3 200 68 50 90 120

d
H2

A1
A2
H1

A3

Fig 1

d
B1
H2

A1
H1

A2
A3

Fig 2
B1
B2
H2

A1
d
H1

A2
A3

Fig3

Base

Products Overall dimension(mm)


model Drawing A1 A2 A3 B1 B2 H1 H2 Φd
RT16-00-B Fig 1 25 100 120 - - 25 60 7.5
RT16-0-B Fig 2 25 100 120 30 - 25 60 7.5
RT16-1-B Fig 3 25 175 200 30 58 38 84 10.5
RT16-2-B Fig 3 25 200 225 30 60 38 84 10.5
RT16-3-B Fig 3 25 210 250 30 60 40 105 10.5
RT16-4-B Fig 3 25 264 300 30 88 40 137 9

174 www.sassin.com www.sassin.com 0