KAM® SR™ SAMPLE RECEIVER PER API 8.

2, ASTM D4177
AND ISO 3171

TEL +1 713 784 0000


FAX +1 713 784 0001
User Guidelines
Email Sales@Kam.com SRMANUAL-0621
KAM CONTROLS, INC.
3939 Ann Arbor Drive
Houston, Texas 77063 USA
www.KAM.com
KAM® SR™ SAMPLE RECEIVER

S P E C I F I C AT I O N S

Volume: KAM SR03 – 3 Gallons (11.4 L)


KAM SR05 – 5 Gallons (18.9 L)
KAM SR10 – 10 Gallons (37.8 L)
KAM SR15 – 15 Gallons (56.8 L)

Pressure: Design – 130 psig

Material: Stainless steel with viton lip seals

Inlet: ½" Male quick connect

Outlet: ¾" Male quick connect

Dimensions: KAM SR03 – 8.25" Dia. x 17.75" H (210mm x 451mm)


KAM SR05 – 8.25" Dia. x 25.75" H (210mm x 654mm)
KAM SR10 – 12.25" Dia. x 25.75" H (311mm x 654mm)
KAM SR15 – 12" Dia. x 41" H (305mm x 1041mm)

Weight: KAM SR03 – 7 lbs. (3.2kg)


KAM SR05 – 9 lbs. (4kg)
KAM SR10 – 11 lbs. (5kg)
KAM SR15 – 34 lbs. (15.4kg)

SRMANUAL-0621 KAM CONTROLS, INC.


KAM® SR™ SAMPLE RECEIVER

B
Optional Pressure gauge Optional high level switch
electrical connection

Sealing lid with security lock


2

2
CSM CONNECTION
FINISH

SS

¾" quick connect–


MATERIAL

to be connected to suction
on KAM® CSM™ Circulating
Sample Mixer pump SAMPLER CONNECTION
½" quick connect–
to be connected to KAM® IAS™ Iso-
FRACTIONAL TOL ±1/64

ALL DIM IN INCHES

UNLESS OTHERWISE
DO NOT SCALE DWG

2 PLACE DEC ±0.010


3 PLACE DEC ±0.005
BREAK SHARP EDGES
REMOVE ALL BURRS

ANGULAR TOL ±1/2

kinetic Automatic Sampler discharge


SPECIFIED

Optional high level switch


(Normally Closed/NC) line
APPVD

DRN

KAM CONTROLS INCORPORATED.


AND SHALL BE RETURNED TO US

THIS DRAWING IN DESIGN AND


IT SHALL NOT BE REPRODICED

CSM CONNECTION
DETAIL IS THE PROPERTY OF
Carlos Andrade
ALL RIGHTS RESERVED

½" quick connect–


ON DEMAND

Internal spray bar system to be connected to discharge line


on KAM® CSM™ Circulating Sample
Mixer pump
SCALE
A
1/6

DWG NO.

Kam
Controls
Incorporated
WWW.KAM.COM
USA
Houston TX 77063
3939 Ann Arbor Dr.
1

1
DATE
1/9/2013

172-004-003

SR 15 Gal Full Assembly plus


PG & LS

TITLE
SHEET
1 OF 2

REV
B

USER GUIDELINES

Do not use KAM® SR™ if dented or damaged Do not lay KAM® SR™ Sample Receiver
horizontally when full
Prior to use, clean the KAM® SR™ Sample
Receiver completely by washing with Do not transport KAM® SR™ Sample Receiver
standard-issue solvent in a horizontal position

Make sure KAM® SR™ Sample Receiver lid Follow API Chapter 8.2 and 8.3, and ISO 3171
with O-ring lip is closed and sealed prior to use guidelines

Wear protective glasses when handling and Follow local hazardous material
mixing the KAM® SR™ Sample Receiver transportation guidelines for all transport

KAM CONTROLS, INC. reserves the right to make changes to this document without notice.