DESCRIPTION  

REMARKS DATE BY
                                           

           

           

           

           

           

App./Constr./Ref./Fly.               

No. OF PRINT                  

             
DATE      
PRINT RECORD

REVISION                  

OWNER                  

CLASS                  

PJS/APM                   

COM. (SB)                  

QA/QC                  

PRODUCTION                  

                   
REFERENCE DRAWING
 
    PT. STEADFAST MARINE
                           
DWG. No. DRAWING TITLE   SHIP BUILDING, ENGINEERING & NAVAL ARCHITECT  
External Fire Fighting JL.KHATULISTIWA KM.6.6 BATULAYANG PONTIANAK
07-539 System KALIMANTAN BARAT INDONESIA 78244
 
TELP. 0561 – 881725 FAX 0561 - 885206  

   

PROJECT
 

40M AHT VESSEL


( LOGINDO VIGILANT )

TITLE :  
OPERATION MANUAL BOOKLET
EXTERNAL FIRE FIGHTING SYSTEM

 APPROVED BY DATE PREPARED BY: SYUKUR S. SCALE : NTS REV 0

 OWNER :         CHECKED BY : PROJECT No. : PAGE :

 
APPROVED BY : 010307-012 1

 CLASS : ABS       DATE : DOCUMENT No. : TOTAL PAGE :


 
  14/08/2008 012/007 6
               
PT. STEADFAST MARINE
(SHIP BUILDING, ENGINEERING & NAVAL ARCHITECT)
JL.KHATULISTIWA KM.6.6 BATULAYANG PONTIANAK
KALIMANTAN BARAT INDONESIA 78244
TELP. 0561 – 881725 FAX 0561 - 885206

CONTENTS

1. To Start Monitors ( +Water Spray and Deck Head)


2. To Start Deck head only
3. To stop Monitors ( +Water Spray and Deck Head)
4. To Start Foam Injection
5. To Start Water Spray only
6. To Draining
7. Caution
8. Typical Fi-Fi Piping Arrangement

Page 2 of 6 Operation Manual Booklet


PT. STEADFAST MARINE
(SHIP BUILDING, ENGINEERING & NAVAL ARCHITECT)
JL.KHATULISTIWA KM.6.6 BATULAYANG PONTIANAK
KALIMANTAN BARAT INDONESIA 78244
TELP. 0561 – 881725 FAX 0561 - 885206

1. To Start Monitor (+Water Spray and Deck Head)

1. Switch panel operation Fi-Fi Sytem to “ON”


2. Open Fi-Fi pump Suction valve
Close Fi-Fi pump Discharge valve
Open by-pass Discharge valve
3. Make sure ready for Fi-Fi lamp on panel is illuminated
4. Start the pump from the control panel
Start at idling speed is recommended
5. Wait until the water flows out of the monitors
6. Open Fi-Fi pump discharge valve from control panel, please note the 2 min interlock delay
7. Operate monitor by using Joystick, Fog/Jet and Foam/Water switches.
8. Open valve for Water Spray System if required
9. Open valve for Deck Head if required

2. To Start Deck head only

1. Switch panel operation Fi-Fi System to “ON”


2. Open Fi-Fi pump Suction valve
Close Fi-Fi pump Discharge valve
Close by-pass Discharge valve
Open Over board valve
Open Deck head main valve
Close Deck head hydrant valves
3. Make sure ready for Fi-Fi lamp on panel is illuminated
Page 3 of 6 Operation Manual Booklet
PT. STEADFAST MARINE
(SHIP BUILDING, ENGINEERING & NAVAL ARCHITECT)
JL.KHATULISTIWA KM.6.6 BATULAYANG PONTIANAK
KALIMANTAN BARAT INDONESIA 78244
TELP. 0561 – 881725 FAX 0561 - 885206

4. Start the pump from the control panel


Start at idle speed is recommended
5. Open required Deck head hydrant valves

3. To Stop Monitor (+Water Spray and Deck Head)

1. Adjust the pump speed to idling speed if possible


2. Close valve for Deck Head
3. Close valve for Water Spray system
4. Close Fi-Fi pump discharge valve
5. Stop the pump from the control panel
6. Switch panel operation to “Stand-by”

4. To Start Foam Injector

1. Make sure Fi-Fi pump is running and water is running out of the monitor in Foam mode or REDUCED
capacity
2. Open Foam/water valve
3. Close Discharge valve
4. Open Foam tank valve
5. Open Foam inductor valve
6. Stop by reversing the procedure

5. To Start Water Spray only

1. Switch panel operation to “ON”


2. Open Fi-Fi pump Suction valve
Close Fi-Fi pump Discharge valve
Page 4 of 6 Operation Manual Booklet
PT. STEADFAST MARINE
(SHIP BUILDING, ENGINEERING & NAVAL ARCHITECT)
JL.KHATULISTIWA KM.6.6 BATULAYANG PONTIANAK
KALIMANTAN BARAT INDONESIA 78244
TELP. 0561 – 881725 FAX 0561 - 885206

Close by-pass Discharge valve


3. Make sure that ready for Fi-Fi lamp on panel is illuminated
4. Start the pump from the control panel
5. Start at idle speed is recommended
6. Open valve for the Water Spray system

6. To Draining
1. Open all valves for the Fi-Fi system
2. Close Fi-Fi pump Suction valve after ~10s
3. Drain the pump casing

7. Caution

1. Do not aim the water jet towards persons


2. Risk of squeezing by the monitor
3. Never start pumps with open discharge valves
4. Never run pumps dry
5. Pump operation without cooling flow max. 30s
6. Never exceed capacity duty point of pumps

Page 5 of 6 Operation Manual Booklet


PT. STEADFAST MARINE
(SHIP BUILDING, ENGINEERING & NAVAL ARCHITECT)
JL.KHATULISTIWA KM.6.6 BATULAYANG PONTIANAK
KALIMANTAN BARAT INDONESIA 78244
TELP. 0561 – 881725 FAX 0561 - 885206

8. Typical Fi-Fi Piping Arrangement

Page 6 of 6 Operation Manual Booklet