Service- and errorcodes MIWE Gärschrank with MNCS

For internal use only!

Servicecodes Gärschrank MNCS

0000 Sets the time / day


SETPOINT / ACTUAL 0…..6 = weekday
TEMPERATURE display 0 = Sunday…..6 = Saturday
TIMER display Setting the time:
TIMER UP / DOWN key

0001 Set date


Required for correct summertime / wintertime clock change.
Year on the TIMER display

Day on the SETPOINT / ACTUAL TEMPERATURE display

Month on the STEAM QUANTITY / PROGRAM NUMBER


display

0004 Automatic summertime / wintertime clock change


The time setting must be correct.
SETPOINT / ACTUAL 0 = no automatic clock change (factory setting).
TEMPERATURE display 1 = automatic clock change

0012 Additional timer


SETPOINT / ACTUAL 0 = not activated
TEMPERATURE display 1 = active (factory setting).

0014 Display with autostart


SETPOINT / ACTUAL 0 = If autostart is active, the display shows the next possible
TEMPERATURE display autostart time and, every 5 seconds, the current time
(factory settings).
1 = Only the next possible autostart time is displayed.

0015 Autostart reactivation


SETPOINT / ACTUAL 0 = not activated
TEMPERATURE display 30.....720 = minutes until automatic autostart
(factory setting = 120 minutes).

MIWE 03.2014 1
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

0016 Continue proofing after power cut


Time within which proofing will be continued without a fault message following a power cut.
SETPOINT / ACTUAL 0 = not activated
TEMPERATURE display 1.....900 = seconds until a fault message
(factory setting = 180 seconds).

0017 Export baking programs to USB flash drive


See 'Data exchange'.

0018 Import baking programs to USB flash drive


See 'Data exchange'.

0022 Cooling fan temperature


SETPOINT / ACTUAL 20.....50 = temperature in °C
TEMPERATURE display (factory setting = 45°C).

0023 Minimum cooling fan speed


SETPOINT / ACTUAL 0.....100 = speed in %
TEMPERATURE display (factory setting = 0).

0035 Analogue value display


SETPOINT / ACTUAL Channel
TEMPERATURE display number Value
Note
Top display (4-digit)
(3 digits)
Maximum temperature
In 0.1°C; display
-2 of circuit board
without decimal point
(can be reset)
-1 Mains frequency in Hz 50 or 60 Hz
In 0.1°C; display
0 PT1000 1 ( X19 50/51 )
without decimal point
In 0.1°C; display
1 PT1000 2 ( X20 52/53 )
without decimal point
In 0.1°C; display
2 PT1000 3 ( X21 54/55 )
without decimal point
In 0.1°C; display
3 PT1000 4 ( X22 56/57 )
without decimal point
In 0.1°C; display
4 PT1000 5 ( X22 58/59 )
without decimal point
5 Slot 1 ( X33 96/97 ) Display in digits

MIWE 03.2014 2
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

0..4095
Display in digits
6 Slot 2 ( X33 94/95 )
0..4095
Display in digits
7 Slot 3 ( X32 92/93 )
0..4095
Display in digits
8 Slot 4 ( X32 90/91 )
0..4095
Display in digits
9 Slot 5 ( X31 88/89 )
0..4095
Display in digits
10 Slot 6 ( X30 85/86 )
0..4095
Temperature of circuit In 0.1°C; display
11
board without decimal point
Internal voltage, MNCS In 0.1°C; display
12
DC without decimal point
In 0.1°C; display
13 Processor temperature
without decimal point
Conversion for plug-in cards:
Card type Item number Digits -> value
0 -> 0.0 V
0..1 V DC analogue MUSILV
4095 -> 5.0 V
input 504069.20
( linear )
0 .. 2047 -> low
24VDS
24 V DC digital input 2048 .. 4095 ->
504069.05
high
230VAC 0 .. 2047 -> high
230 V AC digital input 504069.04 2048 .. 4095 ->
or 504069.041 low
* 35 / 4 in mA
e.g. 1000 -> 8750
Current transformer 504069.33
mA
maximum of 20 A.

0036 MNCS digital value display


SETPOINT / ACTUAL Channel
TEMPERATURE display Digital value
number Frequency
(3-digit display
top setpoint Value ( 4-digit
or LED
display display)
ACTUAL)
(3 digits)
1 ( 2* ) X10 (door) 0/1 0 .. Hz
2 ( 3* ) X11 0/1 0 .. Hz

MIWE 02.2014 3
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

X13 (water
3 ( 0* ) 0/1 0 .. Hz
meter)
4 ( 1* ) X12 0/1 0 .. Hz
* up to version 0010
Channel number Digital value
Top setpoint (3-digit display
Value
display or LED
(3 digits) ACTUAL)
MNCP (power unit)
100 0/1
230V

Channel number Digital value


top setpoint (3-digit display
Value
display or LED
(3 digits) ACTUAL)
101 24V relay board: 1 0/1
102 24V relay board: 2 0/1
103 24V relay board: 3 0/1
104 24V relay board: 4 0/1
105 24V relay board: 5 0/1
106 24V relay board: 6 0/1
107 24V relay board: 7 0/1
108 24V relay board: 8 0/1
109 24V relay board: 9 0/1
110 24V relay board: 10 0/1
111 24V relay board: 11 0/1
112 24V relay board: 12 0/1
X52: 5/6 230V relay
113 0/1
board: 1
X53: 7/8 230V relay
114 0/1
board: 2
X54: 9/10 230V relay
115 0/1
board: 3
X55: 11/12 230V relay
116 0/1
board: 4

MIWE 03.2014 4
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

0041 Automatic AUTOSTART after OFF


SETPOINT / ACTUAL 0 = not activated (factory setting)
TEMPERATURE display 1 = active

0042 OFF at set time


SETPOINT / ACTUAL 24 = not activated (factory setting)
TEMPERATURE display 0.....23 = time at which the device automatically
switches OFF.

0046 Stopping a program in progress


SETPOINT / ACTUAL 0 = immediately (factory setting)
TEMPERATURE display 1 = with 1 second delay

0050 Unit of temperature display


SETPOINT / ACTUAL 0 = °C (degrees Celsius, factory setting).
TEMPERATURE display 1 = F (Fahrenheit)

0100 Setting range: Maximum setpoint temperature


SETPOINT / ACTUAL 0.....50 = maximum setpoint temperature which can be set
TEMPERATURE display in °C
(factory setting = 50 °C).

0101 Setting range: Minimum setpoint temperature


SETPOINT / ACTUAL 0.....50 = minimum setpoint temperature which can be set in
TEMPERATURE display °C
(factory setting = 0 °C).

0102 Temperature hysteresis


SETPOINT / ACTUAL 0.....10 = temperature in °C
TEMPERATURE display (factory setting = 1 °C).

0103 Ready for proofing at higher actual temperature


SETPOINT / ACTUAL 0 = setpoint temperature °C
TEMPERATURE display 1.....20 = °C higher actual temperature – proofing cabinet is
ready for proofing
(factory setting = 1 °C).

0105 Setting range: Maximum setpoint humidity


SETPOINT / ACTUAL 0.....99 = maximum setpoint humidity which can be set in
TEMPERATURE display % RH
(factory setting = 99% RH).

MIWE 02.2014 5
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

0106 Setting range: Minimum setpoint humidity


SETPOINT / ACTUAL 0.....99 = minimum setpoint humidity which can be set in
TEMPERATURE display % RH
(factory setting = 0% RH).

0107 Humidity hysteresis


SETPOINT / ACTUAL 0.....10 = in % RH
TEMPERATURE display (factory setting = 1).

0108 Ready for proofing at higher actual humidity


SETPOINT / ACTUAL 0 = setpoint humidity % RH
TEMPERATURE display 1.....99 = % RH higher actual humidity – proofing cabinet is
ready for proofing
(factory setting = 5% RH).

0110 Temperature display


SETPOINT / ACTUAL 0 = only setpoint values are displayed (factory setting)
TEMPERATURE display 1 = only actual values are displayed
2 = display alternates between setpoint and actual values

0120 Gong signal: Volume at end of proofing


SETPOINT / ACTUAL 0 = OFF
TEMPERATURE display 1.....100 = volume in % (factory setting = 60%).
ON / OFF key Test gong volume.

0121 Gong signal: Gong intervals at end of proofing


SETPOINT / ACTUAL 0.....60 = intervals for gong signal in seconds
TEMPERATURE display (factory setting = 10 seconds).

0122 Gong signal: Tone


SETPOINT / ACTUAL 0.....4 = tone selection (factory setting = 0).
TEMPERATURE display
ON / OFF key Test gong signal.

0123 Gong signal: Duration at end of proofing


SETPOINT / ACTUAL 1.....600 = gong signal duration in seconds
TEMPERATURE display (factory setting = 30 seconds).
999 = gong sounds continuously.

MIWE 03.2014 6
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

0125 Gong signal: Volume for faults


SETPOINT / ACTUAL 0 = OFF
TEMPERATURE display 1.....100 = volume in % (factory setting = 80%).
ON / OFF key Test gong volume.

0126 Gong signal: Gong intervals for faults


SETPOINT / ACTUAL 0.....60 = intervals for gong signal in seconds
TEMPERATURE display (factory setting = 7.5 seconds).

0206 Permissible violation of maximum room temperature


Proofing chamber humidification is deactivated if a preset acceptable violation of the
maximum room temperature is exceeded. This is to prevent further heating from steam.
SETPOINT / ACTUAL 0 = not activated (factory setting).
TEMPERATURE display 1.....20 = switch-off at violation in °C.

0207 Humidity hysteresis in standby


Hysteresis can be set for standby mode.
SETPOINT / ACTUAL 0 = small hysteresis; c. 2% RH (factory setting).
TEMPERATURE display 1 = large hysteresis; c. 20% RH.

0211 Steam cylinder rated current


SETPOINT / ACTUAL 0.....10.0 = A
TEMPERATURE display (factory setting = 3.6).

0212 Pumping factor


SETPOINT / ACTUAL 0.1.....10.0 = pump power
TEMPERATURE display 0.1 = low/slow pump;
10.0 = high/rapid pump
(factory setting = 1.0).

0213 Measuring time


SETPOINT / ACTUAL 0.....120 = time in seconds
TEMPERATURE display (factory setting = 84 seconds).

0214 Input with external steam


SETPOINT / ACTUAL 0 = high (factory setting)
TEMPERATURE display 1 = low
2 = not activated

MIWE 02.2014 7
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

0215 Empty steam cylinder after extended downtime


The water can be pumped out of the steam cylinder after an extended downtime.
SETPOINT / ACTUAL 0 = not activated (factory setting).
TEMPERATURE display 1....240 = downtime until water is pumped out in hours.

0540 Service code and settings reset


SETPOINT / ACTUAL 1 = service code reset
TEMPERATURE display 2 = settings reset

0541 Baking program reset


SETPOINT / ACTUAL 1 = all baking programs permanently deleted.
TEMPERATURE display

0545 Saving/loading factory settings


SETPOINT / ACTUAL 1 = saves current service codes as default file
TEMPERATURE display 2 = loads saved default file with service codes

0553 Boot loader update


Service code 553 can be accessed as soon as a USB flash drive with a new boot loader file
is inserted.
SETPOINT / ACTUAL 4-digit display: “bLup” (boot loader update) appears
TEMPERATURE display 1…..999 = version of current boot loader is
displayed.
START / STOP key The update process begins.
Monitoring with version display possible.

0554 Software update


Service code 554 can be accessed as soon as a USB flash drive with new firmware is
inserted. (In Beta versions also service code 11.)
Setting the current unit type in the latest version. Firmware is distinguished by unit type and
version.
SETPOINT / ACTUAL 1..…999 = unit type
TEMPERATURE display 1…..9999 = version

START / STOP key The update process begins.


START / STOP key + The update process begins. (With other unit type)
ON / OFF key

0555 Control restart


SETPOINT / ACTUAL 1 = control restart (REBOOT)
TEMPERATURE display

MIWE 03.2014 8
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

0560 Create information file on USB flash drive


Service code 560 can be accessed as soon as a USB flash drive is inserted.
SETPOINT / ACTUAL The unit type display goes out as soon as the USB flash drive is
TEMPERATURE display detected.
START / STOP key File generation is launched.

0561 Copies LL log to USB flash drive


SETPOINT / ACTUAL For internal MIWE use only.
TEMPERATURE display

0800 Display test


SETPOINT / ACTUAL All displays are switched on automatically in turn.
TEMPERATURE display
ON / OFF key Hold down to exit.

0801 Key test


SETPOINT / ACTUAL The keys can be used to switch off the illuminated displays.
TEMPERATURE display
ON / OFF key Hold down to exit.

0803 Node number


SETPOINT / ACTUAL 1.....255 = address in RS-485 network
TEMPERATURE display (factory setting = 1).

0804 CAN node number


SETPOINT / ACTUAL 0 = as node number (SC803) (factory setting)
TEMPERATURE display 1…..255 = address in CAN network

MIWE 02.2014 9
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

0807 Relay test


SETPOINT / ACTUAL Outputs RelTest
TEMPERATURE display Rel 1 (X26 70/71/72) 1
Rel 2 (X27 73/74/75) 2
Rel 3 (X28 76/77) 3
Rel 4 (X28 76/78) 4
Rel 5 (X28 76/79) 5
Rel 6 (X28 76/80) 6
Rel 7 (X29 81/82) 7
Rel 8 (X29 81/83) 8
Rel 9 (X29 81/84) 9
Rel 10 (14/11) 10
24V / 24mA door output ( X2 3/4 ) 11
( X5 9/10 ) 12
Cooling fan1 (X6 11/13) 13
Sensor supply ( X7 14/15 ) 14
Internal 15
Cooling fan2 (X8 18/20) 16
RED status (X9 21/22) 17
YELLOW status (X9 23/24) 18
Internal POE 19
Phase control 1 (X15 38/39) 40
Phase control 2 (X15 40/41) 41
Phase control 3 (X18 48/49) 42
0-10V 1 (X16 42/43) 43
0-10V 2 (X16 44/45) 44
0-10V 3 (X17 46/47) 45
PWM cooling fan 1 (X6 12) 46
PWM cooling fan 2 (X8 19) 47

0808 Water meter test


SETPOINT / ACTUAL The solenoid valve can be opened. The water meter reading is
TEMPERATURE display displayed.

0815 Service and baking program lock


Lock baking programs and autostart times to prevent accidental/unauthorised changes.
SETPOINT / ACTUAL 0 = lock not activated (factory setting).
TEMPERATURE display 1 = lock active

0821 PT1000_1
SETPOINT / ACTUAL Adjustment: absolute +- 0.1 °C
TEMPERATURE display (factory setting = 0.0)

MIWE 03.2014 10
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

0822 PT1000_2
SETPOINT / ACTUAL Adjustment: absolute +- 0.1 °C
TEMPERATURE display (factory setting = 0.0)

0823 PT1000_3
SETPOINT / ACTUAL Adjustment: absolute +- 0.1 °C
TEMPERATURE display (factory setting = 0.0)

0824 PT1000_4
SETPOINT / ACTUAL Adjustment: absolute +- 0.1 °C
TEMPERATURE display (factory setting = 0.0)

0825 PT1000_5
SETPOINT / ACTUAL Adjustment: absolute +- 0.1 °C
TEMPERATURE display (factory setting = 0.0)

0831 PT1000_1
SETPOINT / ACTUAL Adjustment: relative +- 0.1 %
TEMPERATURE display (factory setting = 0.0)

0832 PT1000_2
SETPOINT / ACTUAL Adjustment: relative +- 0.1 %
TEMPERATURE display (factory setting = 0.0)

0833 PT1000_3
SETPOINT / ACTUAL Adjustment: relative +- 0.1 %
TEMPERATURE display (factory setting = 0.0)

0834 PT1000_4
SETPOINT / ACTUAL Adjustment: relative +- 0.1 %
TEMPERATURE display (factory setting = 0.0)

0835 PT1000_5
SETPOINT / ACTUAL Adjustment: relative +- 0.1 %
TEMPERATURE display (factory setting = 0.0)

0841 Misc_1
SETPOINT / ACTUAL Adjustment: absolute +- 0.1 °C
TEMPERATURE display (factory setting = 0.0)

MIWE 02.2014 11
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

0842 Misc_2
SETPOINT / ACTUAL Adjustment: absolute +- 0.1 °C
TEMPERATURE display (factory setting = 0.0)

0843 Misc_3
SETPOINT / ACTUAL 0.0 adjustment: absolute +- 0.1
TEMPERATURE display (factory setting = 0.0)

0844 Misc_4
SETPOINT / ACTUAL Adjustment: absolute +- 0.1 °C
TEMPERATURE display (factory setting = 0.0)

0845 Misc_5
SETPOINT / ACTUAL Adjustment: absolute +- 0.1 °C
TEMPERATURE display (factory setting = 0.0)

0846 Misc_6
SETPOINT / ACTUAL Adjustment: absolute +- 0.1 °C
TEMPERATURE display (factory setting = 0.0)

0851 Misc_1
SETPOINT / ACTUAL Adjustment: relative +- 0.1 %
TEMPERATURE display (factory setting = 0.0)

0852 Misc_2
SETPOINT / ACTUAL Adjustment: relative +- 0.1 %
TEMPERATURE display (factory setting = 0.0)

0853 Misc_3
SETPOINT / ACTUAL Adjustment: relative +- 0.1 %
TEMPERATURE display (factory setting = 0.0)

0854 Misc_4
SETPOINT / ACTUAL Adjustment: relative +- 0.1 %
TEMPERATURE display (factory setting = 0.0)

0855 Misc_5
SETPOINT / ACTUAL Adjustment: relative +- 0.1 %
TEMPERATURE display (factory setting = 0.0)

MIWE 03.2014 12
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

0856 Misc_6
SETPOINT / ACTUAL Adjustment: relative +- 0.1 %
TEMPERATURE display (factory setting = 0.0)

0959 Overvoltage fault


SETPOINT / ACTUAL 0 = yes
TEMPERATURE display 1 = no
(only deactivate if transformer checked and network tolerance
really is 10%)

0970 Sets IP address


ETPOINT 0 – 3 = IP address
TEMPERATURE display 4 – 7 = network mask
8 – 11 = gateway
Display 0.....255 = value input
PROGRAM PHASE

0977 CAB password (last 3 digits/characters)


SETPOINT / ACTUAL 0…..999
TEMPERATURE display

0978 CAB password, first 3 digits/characters


SETPOINT / ACTUAL 0…..999
TEMPERATURE display

0980 Continuous test


SETPOINT / ACTUAL 0 = no (factory setting)
TEMPERATURE display 1 = yes

0990 LL log, timer


SETPOINT / ACTUAL 0.....999 = time in seconds
TEMPERATURE display (factory setting = 60 seconds).

0991 LL log, days


SETPOINT / ACTUAL 0 = not activated (factory setting)
TEMPERATURE display 1.....30 = in days

MIWE 02.2014 13
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

0995 Key click


Keys sound when pressed
SETPOINT 0 = no (factory setting).
TEMPERATURE display 1 = yes

Errorcodes Gärschrank MNCS


19 – Power failure
Power supply has been interrupted. By owner-operator
• Check to make sure that the unit is properly
connected to the power supply.
• Switch the unit back on.

If the fault continues, contact MIWE service.

20 – Dual sensor for humidity / temperature defective


Temperature > 65°C By owner-operator
• Replace the dual sensor (see “Replacing the
dual sensor”).
If the fault continues, contact MIWE service.

21 – Dual sensor for humidity / temperature defective


Temperature < -10°C By owner-operator
• Replace the dual sensor (see “Replacing the
dual sensor”).
If the fault continues, contact MIWE service.

22 – Dual sensor for humidity / temperature defective


Humidity > 120% RH By owner-operator
• Replace the dual sensor (see “Replacing the
dual sensor”).
If the fault continues, contact MIWE service.

23 – Dual sensor for humidity / temperature defective


Humidity < 8% RH By owner-operator
• Replace the dual sensor (see “Replacing the
dual sensor”).
If the fault continues, contact MIWE service.

50 – Control temperature sensor defective


Ambient temperature of controls > 90 °C By MIWE service

MIWE 03.2014 14
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

51 – Control temperature sensor defective


Ambient temperature of controls < 5°C By owner-operator
• Switch on the unit and wait for the ambient
temperature of the controls to exceed 5°C.

If the fault continues, contact MIWE service.

52 – Warning: ambient temperature of controls too high


Ambient temperature of controls > 60°C By owner-operator
• Ensure that there is additional ventilation, for
example fans, when the device is installed.
• Lower the ambient temperature of the
controls by ventilating the bakery.
If the fault continues, contact MIWE service.

60 – Steam cylinder overcurrent or inlet valve constantly open


By MIWE service

61 – Water level in steam cylinder too low


Low water level or solenoid valve defective By owner-operator
• Open the water supply line.
If the fault continues, contact MIWE service.

62 – Steam cylinder defective


By MIWE service

88 – SD memory card not inserted


By MIWE service

89 – Real-time clock (RTC) is not working (bError_RTC)


The time is not correctly set. By owner-operator
• Set the correct time.
If the fault continues, contact MIWE service.

90 – Output driver reports overcurrent


Internal relays By MIWE service

90–98 – Circuit board fault


By MIWE service

MIWE 02.2014 15
Service- and errorcodes MIWE Gärschrank with MNCS
For internal use only!

91 – Output driver reports overcurrent


24V power module, relay module By MIWE service

92 – Output driver reports overcurrent


24V sensor supply By MIWE service

93 – Output driver reports overcurrent


24V TRIAC modules, digital input 1 By MIWE service

94 – Output driver reports overcurrent


24V POE By MIWE service

95 – Output driver reports overcurrent


24V cooling fan 1 By MIWE service

96 – Output driver reports overcurrent


24V cooling fan 2 By MIWE service

97 - Output driver reports undervoltage


bError_6816_PSF By MIWE service

98 - Output driver reports high temperature


bError_6816_TP By MIWE service

99 – Warning: ambient temperature of controls too high


Ambient temperature of controls > 65 °C Unit heaters switch off automatically.
By owner-operator
• Ensure that there is additional ventilation, for
example fans, when the device is installed.
• Lower the ambient temperature of the
controls by ventilating the bakery.
If the fault continues, contact MIWE service.

MIWE 03.2014 16