List of contents for . . .

because details make the difference

function description CM/ C1_07/C1_09

Page 2 - 3 Selection of a mode


Page 4 Indication of actual values
Page 5 - Steam mode 100°C
Page 6 - 7 Vario-steam mode 30-99°C
Page 7 - 8 Combi-steam mode 30-300°C
Page 8 - 9 Reheating mode 30-300°C
Page 10 Hot air mode 30-300°C
Page 11 Quenching system
Page 12 SC-automatic system
Page 12 - 15 Additional functions
Page 15 Total reset
Page 16 Function display
Page 17 - 19 Programming procedure
Page 19 - 20 Changing and storing of cooking values
Page 20 Deleting of single programs
Page 20 - 21 Program locking system
Page 22 - 26 Diagnostic program
Page 27 - 28 Function test

CM C1_09KD-S/Md 12/98 1
Function description CM (C1_O7/C1_09)
This Software Version can be used in electric-, as well as in
gas units.
To use this Software Version in gas units, it is necessary to install
a link permanently on connector X8 (of the CPU pcb) between ter-
minal 1 and 2 before changing the Software Version or carrying out
a Total Reset.
Version C1_07 can only be used in processor pcb without
extended memory
Version C1_09 can only be used in processor pcb with exten-
ded memory

1. Mode switch
After switching on the unit to any mode, the LED of the chosen
mode lights up and the green “on” indicator turns on.

STEAM O

HOT AIR
COMBI STEAM
VARIO STEAM
REHEATING
PROG C

1.1 On / off / on time, or power failure shorter than 4 sec.:


The last chosen function status will remain.

1.2 On / off / on time, or power failure longer than 4 sec.:


0.
The last chosen mode and interior cabinet temperature will be O

taken over. On the timer display “0.” will be displayed and the
buzzer sounds. If the timer was set to “d.” (continuous running),
before the power failure, the unit remains on “d.”.
O

In program mode the “Prog” LED lights up and on the program


number display “C” (cleaning program) will be shown.
C.

2 CM C1_09 KD-S/Md 12/98


1.3 Selection of cooking mode
A) Switch on Combi-Steamer to the desired mode with the dial:
Steam mode 100°C
Hot air mode 30 - 300 °C O

Combi mode 30 - 300 °C


Vario steam mode 30 - 99 °C
Reheating mode 30 - 300 °C
PROG = Program mode
„C“ = Cleaning program C.
„1 - 9“ Program numbers with maximum
„3“ steps

B) On the temperature display the selected temperature 180


will be shown, except in steam mode (100°C is preset) C F
By turning the temperature dial, the desired cooking cabinet O

temperature can be set.

C) The timer display shows „0.“ and the buzzer sounds, when 120.
the cabinet door is closed or „d.“ if the dial was set to this
position befor the unit was switched on. O

First set the dial to „0“-position, afterwards it is possible to


select a running time (1 - 120 min.) or to choose „d.“ for
continuous running.

12
D) Or by pressing the core temperature symbol first it is possi-
ble to select core temperature. 80
The upper core temperature display shows the actual
temperature of the meat probe. O

The lower core temperature display shows the preset core tem-
perature.
It is possible to select a core temperature between
20 - 99°C with the dial.

CM C1_09KD-S/Md 12/98 3
E) Indication of actual cooking values:
During running a cooking mode or a program, the
interior cabinet temperature push button will be pres-
sed, the following actual cooking values will be shown

The interior cabinet temperature display shows the actual


cabinet temperature 92
C F
O

The timer display shows the elapsed cooking time


On the core temperature display the actual core 87
temperature will be indicated (only if temperature is below
100°C). 16
O

During running a program, the actual program number will be


shown on the program number display e. g. „2.“
program number with dot. The actual program step (number
without dot) is switched off during this time 5.

4 CM C1_09 KD-S/Md 12/98


2. Steam mode 100°C

2.1 Basic condition steam saturation


Cooking cabinet temperature is preset to 100°C, without indication
on interior cabinet temperatur display

2.2 Preheating steam generator up to 85°C


stand-by-temperature
- Thermocouple B5 on steam heaters
Timer countdown starts after preheating of steam generator. 23.
Countdown of time is shown on front panel timer display with O

flashing dot.

2.3 Heating up of interior cabinet with steam generator


energy 100/50 %
- Thermocouple B4 bypass sensor

2.4 Above 92°C interior cabinet temperature, addition


of hot air energy is possible, 100/50%
- Thermocouple B 1 interior cabinet sensor

2.5 Quenching temperature is set to 70°C ex works


(possible range 50 - 120°C)
- Thermocouple B2 quenching sensor

2.6 Temperature control of steam generator


The steam generator temperature is measured by the thermocouple
B5 on steam heater. When the thermocouple reaches a temperatu-
re of 150°C, the steam heaters will be switched off immediately.
Steam heating will be switched on again when the temperature
drops below 150°C.

Indication “unit too hot” will come on after 2 minutes when the
temperature remains above 150°C, the thermocouple is defect or
the temperature of the steam generator is below -5°C.

In case of lack of water measured by electrode/water level control,


the “lack of water” display will come on with a delay of 30 sec.

2.7 Fan motor cycle control


Initial start of fan motor: clockwise/counter-clockwise
61/101/201 models: 112 sec. clockwise, 8 sec. break,
112 sec. counter-clockwise
102/202 models: 100 sec. clockwise, 20 sec. break,
100 sec. counter-clockwise

2.8 If actual interior cabinet temperature is more than 15°C above


preset temperature, the LED of the steam mode will flash.

2.9 Possible additional functions: Cool down

CM C1_09KD-S/Md 12/98 5
3. Vario-steam mode 30 - 99 °C

3.1 No steam saturation

3.2 Preheating steam generator up to 85°C


stand-by-temperature 23.
- Thermocouple B5 on steam heaters O

Timer countdown starts after preheating of steam generator.


Countdown of time is shown on front panel timer display with flas-
hing dot.

3.3 Heating up of interior cabinet with steam generator


energy 100/50%
- Thermocouple B1 interior cabinet sensor

3.4 Above 93°C hot air addition is possible (50% only)


- Thermocouple B1 interior cabinet sensor

3.5 Quenching temperature set to 70°C ex works


(possible range 50 - 120°C)
- Thermocouple B2 quenching sensor

3.6 Temperature control of steam generator


The steam generator temperature is measured by the thermocouple
B5 on steam heater. When the thermocouple reaches a temperatu-
re of 150°C, the steam heaters will be switched off immediately.
Steam heating will be switched on again when the temperature
drops below 150°C.

Indication “unit too hot” will come on after 2 minutes when the
temperature remains above 150°C, the thermocouple is
defect or the temperature of the steam generator isbelow -5°C.

In case of lack of water measured by electrode/water level control,


the “lack of water” display will come on with a delay of 30 sec.

3.7 Fan motor cycle control


Initial start of fan motor: clockwise/counter-clockwise
61/101/201 models: 112 sec. clockwise, 8 sec. break,
112 sec. counter-clockwise
102/202 models: 100 sec. clockwise, 20 sec. break,
100 sec. counter-clockwise

6 CM C1_09 KD-S/Md 12/98


3.8 Intermittent running of fan motor:
A) If the actual interior cabinet temperature is more than 5°C
longer than 2 min. above the preset temperature, the fan motor
runs intermittently, without indication on the front panel.

B) 110 sec. off, 10 sec. clockwise,

C) 110 sec. off, 10 sec. counterclockwise.

3.9 If actual interior cabinet temperature is more than 15°C above


preset temperature, the LED of vario-steam mode will flash.

3.10 Possible additional functions


Cool down

4. Combi-steam mode 30 - 300°C

4.1 Preheating steam generator up to 85°C


stand-by-temperature
- Thermocouple B5 on steam heaters 23.
O
Timer countdown starts after preheating of steam generator.
Countdown of time is shown on front panel timer display with
flashing dot.

4.2 Heating up of interior cabinet with hot air energy


100/50%
- Thermocouple B1 interior cabinet sensor

4.3 Supply of steam by steam generator 100/50%


- Thermocouple B4 bypass sensor

4.4 Quenching temperature set to 70°C ex works


(possible 50 - 120°C)
- Thermocouple B2 quenching sensor

4.5 If actual interior cabinet temperature is more than 15°C above


preset temperature, the LED of the combi-steam mode will flash.

CM C1_09KD-S/Md 12/98 7
4.6 Temperature control of steam generator
The steam generator temperature is measured by the thermocouple
B5 on steam heater. When the thermocouple reaches a temperatu-
re of 150°C, the steam heaters will be switched off immediately.
Steam heating will be switched on again when the temperature
drops below 150°C.

Indication “unit too hot” will come on after 2 minutes when the
temperature remains above 150°C, the thermocouple is
defect or the temperature of the steam generator is below -5°C.

In case of lack of water measured by electrode/water level control,


the “lack of water” display will come on with a delay of 30 sec.

4.7 Fan motor cycle control


Initial start of fan motor: clockwise/counter-clockwise
61/101/201models: 112 sec. clockwise, 8 sec. break,
112 sec. counter-clockwise
102/202 models: 100 sec. clockwise, 20 sec. break,
100 sec. counter-clockwise

4.8 Intermittent runnig of fan motor (temperature


range 30-99°C):
A) If the actual interior cabinet temperature is more than 5°C
longer than 2 min. above the preset temperature, the fan motor
runs intermittently, without indication on the front panel.

B) 110 sec. off, 10 sec. clockwise,

C) 110 sec. off, 10 sec. counterclockwise.

4.9 Possible additional functions


Cool down

5. Reheating mode 30°C - 300°C

5.1 Preheating steam generator up to 85°C


stand-by-temperature
- Thermocouple B5 on steam heaters
23.
O

Timer countdown starts after preheating of steam generator.


Countdown of time is shown on front panel timer display with flas-
hing dot.

8 CM C1_09 KD-S/Md 12/98


5.2 Heating up of interior cabinet by alternating operation of hot
air and steam energy from beginning, depending on the demand of
individual controlling sensor (priority changes every 8 sec.).
- Temperature control: Thermocouple B1
interior cabinet sensor - hot air energy
- Humidity control: Thermocouple B4
bypass sensor - steam energy
On gas units the hot air burner is active until the set temperature is
reached. The steam burner additionally is active in a time sequence
of 15 seconds (15 sec. on, 15 sec. off)

5.3 Quenching temperature is set to 70°C ex works


(possible range 50 - 120°C)
- Thermocouple B2 quenching sensor

5.4 If actual interior cabinet temperature is more than 15°C above


preset temperature, the LED of the reheating mode will flash.

5.5 Temperature control of steam generator


The steam generator temperature is measured by the thermocouple
B5 on steam heater. When the thermocouple reaches a temperatu-
re of 150°C, the steam heaters will be switched off immediately.
Steam heating will be switched on again when the temperature
drops below 150°C.
Indication “unit too hot” will come on after 2 minutes when the
temperature remains above 150°C, the thermocouple is defect or
the temperature of the steam generator is below -5°C.
In case of lack of water measured by electrode/water level control,
the “lack of water” display will come on with a delay of 30 sec.

5.6 Fan motor cycle control


Initial start of fan motor: clockwise / counter-clockwise
61/101/201 models: 112 sec. clockwise, 8 sec. break,
112 sec. counter-clockwise
102/202 models: 100 sec. clockwise, 20 sec. break,
100 sec. counter-clockwise

5.7 Intermittent runnig of fan motor (temperature


range 30-99°C):
A) If the actual interior cabinet temperature is more than 5°C
longer than 2 min. above the preset temperature, the fan motor
runs intermittently, without indication on the front panel.

B) 110 sec. off, 10 sec. clockwise,

C) 110 sec. off, 10 sec. counterclockwise.

5.8 Possible additional functions


Cool down

CM C1_09KD-S/Md 12/98 9
6. Hot air mode 30 - 300°C

6.1 Heating up of interior cabinet 100/50%


- Thermocouple B1 interior cabinet sensor

6.2 Quenching temperature is set to 90°C ex works


(possible range 50 - 120°C)
- Thermocouple B2 quenching sensor

6.3 During Hot air mode indication "lack of water" will not
be
shown.

6.4 Fan motor cycle control


Initial start of fan motor; clockwise/counter-clockwise
61/101/201 models: 112 sec. clockwise, 8 sec. break,
112 sec. counter-clockwise
102/202 models: 100 sec. clockwise, 20 sec. break,
100 sec. counter-clockwise

6.5 Intermittent runnig of fan motor (temperature


range 30-99°C):
A) If the actual interior cabinet temperature is more than 5°C
longer than 2 min. above the preset temperature, the fan motor
runs intermittently, without indication on the front panel.

B) 110 sec. off, 10 sec. clockwise,

C) 110 sec. off, 10 sec. counterclockwise.

6.6 If actual interior cabinet temperature is more than 15°C above


preset temperature, the LED of the hot air mode will flash.

6.7 Possible additional functions


Moistening (actual temperature range 120 - 250°C),

Cool down

10 CM C1_09 KD-S/Md 12/98


7. Quenching system CM
Quenching system for drain outlet of interior cabinet
Thermocouple B2, solenoid valve Y2

Changing of quenching temperature


The quenching temperatures are set to 70°C ex works
(exception: hot air mode 90°C ex works) and can be varried bet-
ween 50 and 120°C. The change of the quenching temperature can
be carried out on the control panel. O

Procedure:
7.1 Select mode on which you like to change quenching
temperature, LED of cooresponding symbol will illuminate.

7.2 Press and hold down interior cabinet temperature and core 70
temperature push button (for more than 10 sec.). Keep both
push buttons pressed during the whole procedure.
Memorized quenching temperature will be shown on actual and
70
preset core temperature display simultaneously O

7.3 With both push buttons still pressed turn the core temperature
dial to zero position. Now the required quenching temperature 80
can be selected (range between 50 and 120°C) with the core tem-
perature dial (e.g. 80°C). 70
7.4 On the upper core temperature display the new quenching tempe- O
rature (e.g. 80°C) will be shown.
On the lower core temperature display the old quenching tempera-
ture (e.g. 70°C) will be indicated.

7.5 With interior cabinet temperature and core temperature


push button still pressed, select the next desired cooking mode in
which the quenching temperature shall also be changed.
Continue as described in step 7.3 and 7.4.

7.5 Release both push buttons, to memorize all new quenching


temperatures.