Print Date: Mon Jul 27 10:34:21 CEST 2009 MODEL 550 Bravo MAINTENANCE MANUAL (Rev 22)

26-11-02(Original Issue)

CONTROL UNIT- MAINTENANCE PRACTICES

1. General
A. There are two fire detection control units (UT004, Left and UT002, Right) located in the tailcone
accessible through the tailcone baggage door.
B. Removal and installation procedures are typical for both units.
2. Fire Detection Control Unit Removal/Installation
A. Remove Fire Detection Control Unit (Refer to Figure 201).
(1) Disconnect electrical connector (PT004, Right or PT003, Left) from control unit.
(2) Remove screws securing control unit to structure.
B. Install Fire Detection Control Unit (Refer to Figure 201).
(1) Secure fire detection control unit to beam with screws.
(2) Connect electrical connector (PT004, Right or PT003, Left) to control unit and safety wire.
(3) Conduct fire detection system check for proper operation.

© 2009 Cessna Aircraft Company


Retain printed data for historical reference only. For future maintenance, use only current data. Page 1
Print Date: Mon Jul 27 10:34:21 CEST 2009 MODEL 550 Bravo MAINTENANCE MANUAL (Rev 22)
26-11-02(Original Issue)

Figure 201. Fire Detection Control Unit

Sheet 1 of 1

© 2009 Cessna Aircraft Company


Retain printed data for historical reference only. For future maintenance, use only current data. Page 2