HEALTHIER
AND SAFER
- Hans Hofmann -
MORE THAN 6 YEARS
OF RESEARCH,DEVELOP
INNOVATION OF LABORATORY
DESIGN SYSTEM.
CABINET
2 Doors Floor Cabinet 8 Drawers Floor Cabinet
Dimension (P x L x T) = 810mm x 600mm x 792mm Dimension (P x L x T) = 810mm x 600mm x 792mm
FEATURE
Structure Steel tube frame structure dengan system suspended.
Frame/structure : H frame Metal Hollow 60 x 40 x 1.2 - 1.7 mm
Finish by the epoxy resin powder coa ng.
Cabinet & Drawer All material cabinet body panel, door & drawer used 1.2mm thick
of cold-rolled steel sheet produc on
All the steel parts by picking, posphated treatment surface by epoxy resin powder coa ng.
Chemical Top Table Phenolic Resin 16mm, Chemical resistant, Ex Funder Max / Maica/ Trespa : Colour : Grey
Bitch, White & Black
Accessories 1 ea Service Duc ng Dengan material steel sheet, epoxy resin powder coa ng. Socket Electric
Ex berker or legran or mennekes with close cap
Socket Electric Ex berker or legran or mennekes with close cap
1 ea Polypropylene Sink, 1 ea Polypropylene Waste, 1 ea Polypropylene An Bo le Trap
1 ea Single Way Swivel Outlet Water Fi ng
Using a double track system (can be pulled up to 2 pulls) so that if desired, the drawer can be
opened wider. Equipped with ball bearing, so that the rail is not easily damaged even if opened
and closed many mes
Furniture Laboratory
FEATURE
Structure Steel tube frame structure dengan system suspended.
Frame/structure : H frame Metal Hollow 60 x 40 x 1.2 - 1.7mm
Finish by the epoxy resin powder coa ng.
Cabinet & Drawer All material cabinet body panel, door & drawer used 1.2mm thick
of cold-rolled steel sheet produc on
All the steel parts by picking, posphated treatment surface by epoxy resin powder coa ng.
Chemical Top Table Phenolic Resin 16mm, Chemical resistant, Ex Funder Max / Maica/ Trespa : Colour : Grey
Bitch, White & Black
Accessories 1 ea Service Duc ng Dengan material steel sheet, epoxy resin powder coa ng. Socket Electric
Ex berker or legran or mennekes with close cap
Socket Electric Ex berker or legran or mennekes with close cap
1 ea Polypropylene Sink, 1 ea Polypropylene Waste, 1 ea Polypropylene An Bo le Trap
1 ea Single Way Swivel Outlet Water Fi ng
Using a double track system (can be pulled up to 2 pulls) so that if desired, the drawer can be
opened wider. Equipped with ball bearing, so that the rail is not easily damaged even if opened
and closed many mes
Instruments Bench
FEATURE
Structure
Frame/structure : H frame Metal Hollow 50 x 100 x 1.2 mm Stainless Steel 304
Accessories Socket Electric Ex berker or legran or mennekes with close cap and grounding
Leveling Feet Heavy Duty
Using a double track system (can be pulled up to 2 pulls) so that if desired, the drawer can be
opened wider. Equipped with ball bearing, so that the rail is not easily damaged even if opened
and closed many mes
Accessories Furniture Laboratorium
Fauchet
Fume Hood
Exhaust Fans
Dedicated to ensure safety
In order to ensure safety, Seat fans are dedicated for extraction of gases,
vapours and fumes in toxic and corrosive environments.
Polypropylene Structure
Resistance to chemical corrosion in plastic fans depends primarily on the
thermoplastic material and compounding components used. We chose to use
a polypropylene structure. Polypropylene is a material resistant to most products
used in laboratories, strong mineral acids, caustic and ammoniac solutions, inorganic
saline solutions and organic and detergent products.
1 Air-conditioning unit 2 Air supply 3 Air exhaust 4 Outlet of air exhausted from the laboratory 5 Fume hood 6 Exhausted cabinet
7 Air flow controller /constant exhaust/ 8 Silencer 9 Air flow controller (controlled flap) 10 Air supply inlet 11 Local exhaust 12 Source bridge
HVAC stands for Heating Ventilation and Air-Conditioning, which are generally related with heating
and cooling. The HVAC is a system or machine that performs three functions main with three separate
channels namely heating, cooling and air ventilation.
The working principle of HVAC is to move air to the desired areas, either indoors, temperature,
humidity, ventilation, or in air purity.
The HVAC system controls about: The number of particles in the environmental air, the number of
microbes in the air environment and on the surface of the object.
- The formula for the suction power or the ability to suck air per hour
Q=VxN
N = Number of air changes per hour (ACH) / hourly air changes (Std 12-15)
Q = the rate of air
V = volume of space (W x W x H)
Index Every room is different. The more "dirty" the space, the greater the index value.
Example: If the room to be installed with an exhaust fan is a bedroom measuring 3m x 3m x 3m,
then V = 27m and N = 5, then the volume of water needed is 27m³ x 5 = 135m³ / hour.
note: negative pressure room, ach fresh air must be lower than ach exhaust. And vice versa
Labopur
Filtration Cabinet
OPERATING PROCESS
The fan harmful and toxic vapors from the cabinet. The charcoal
filter purifies the fumes before safely rejecting then in the environnement.
CONFORMITY
- Active charcoal filters adsortion capacity and filtration system are tested
and certified NF X 15-211.
- Electric fans are in confortunity with european specification CE.
ADVANTAGES
- Labopure’s technology.
- Adaptability to all types of cabinets, with 3 inlets for connection.
- Easy installation and connection.
- Warning light insures good functionning of the ventilation system.
- Front control window immediately indicates if the filter is inside and
well adapted to your needs.
- High efficiency active charcoal filter specialised and treated following
products stored in compliance with NF X 15-211.
- Dust-protecting pre-filter, efficiency 92% for particles over 3 um.
- Easy replacement of the active charcoal filter.
- The standard timer supplied with your recycling air box indicates the
total use of your box. After programming, every 60 hours, a sound alarm
invites you the check the saturation of the active charcoal filter.
Labopur TECHNICAL SPECIFICATIONS
- Steel frame 12/10th.
- Epoxy painting : white RAL 9010, blue RAL 5015.
- Soft and silent electrical fan : 220-240 volts - 20 watts, 0,1 A, 43 db (A)
(excluding air flow) - Airflow 86 m3/hour - Protection : Ip54.
- Inlet airflow diameter : 100mm.
Uses of Clinical / Research Grade Water
Water Purification
Fume Hood FGL Series
FEATURE
Structure Overall material used white PP(polypropylene) plates,seamless welding rod
through the same color treatment to ensure the cabinet strong and ghtness. Door handles and
hinges,by a PP injec on molding material produced. PP material laboratory furniture has excellent
corrosion resistance.
Made of PP, thickness 8 mm, Resistant to strong acid, alkali and an -corrosion.
Size
1200x850x2280mm 1500x850x2280mm 1800x850x2280mm
Chemical Top Table 1. Phenolic Resin 16mm, Chemical resistant, Ex Maica : Colour : Black
2. PP White Thickness 8mm
Accessories Fluorescent lamp, Air value,Base cabinet, Sash window max Opening: 850 mm,
Air Velocity: 0.4 - 0.6 m/s ,Noise ≤60 dB, Fluorescent Lamp: 30 W*1,
Blower Built-in Centrifugal blower, Front Window Manual, 6 mm
toughened glass, height adjustable .Power Supply: 220 V, 50 Hz,
Waterproof socket.
Application for
Life Science Laboratory
Cleanes - Durability - Regulation Acceptances
Leading the Safety
Sales Engineer :
Tsabita Adlila
Mobile : +62 811-1073546
Sales Engineer :
Fatarizky Muhamad
Mobile : +62 811-8173-546