You are on page 1of 4

XZ12 Series DIN

Two-Wire Transmitter
mTech’s DIN-Style Model XZ12
two-wire transmitter accepts all
standard process inputs from field
transmitters and transducers. Model
XZ12 offers the following state-of-
the-art two-wire transmitter signal
conditioning features and options.

• Easy-Access Zero and


Span Settings.
Potentiometer settings are located
on the front panel to allow for easy
set up, calibration and adjustment.

Model XZ12 Input Options


• Input/Output Power Isolation
Model XZ12 two-wire transmitters can accept the
following input types: and RFI/EMI Protection.
Optional RFI / EMI protection and
built-in input / output isolation
maintain a high level of accuracy
• Thermocouple in noisy environments.

• DC Current/Voltage

• AC Current/Voltage • Input Linearization Option.


Linearized 100 Platinum RTDs.

• RTD

• Resistance
XZ12 Specifications

Model XZ12-T Transmitter Specifications Model XZ12-D Transmitter Specifications


(continued)
Inputs
Thermocouple types: All Thermocouple Types Load Resistance
Span: 5 mV to 80 mV (±10% adjustable, Vsupply – 12 V
factory configured) RL= 20 mA (or 50 mA)
Zero: -20 mV to +20 mV (±10% adjustable,
factory configured)
Linearization: Midpoint adjustable
Performance
Accuracy: ±0.1% of span
(factory configured)
±0.25% of span for span<5 mV
Temperature Effect:
Output (-40 to 85°C) 0.01%/°C of span
Operating Temperature: -40 to 85°C
Standard: 4 –20 mA
Storage Temperature: -40 to 100°C
Optional: 10 – 50 mA
Response Time: 0.5 seconds for 98% change
CMRR: Better than 120 dB (60Hz)
Load Resistance Ripple: Less than 0.05% Vrms of span
Vsupply – 12 V
RL= RFI Protection (option): Input and Output connections AC
20 mA (or 50 mA)
de-coupled to ground
Performance
Accuracy: ±0.1% of span Power Supply
Temperature Effect: Power Supply: 12 – 60 Vdc
(-40 to 85°C) 0.01%/°C of span + 1µ V/°C
Cold Junction Error: ±0.1°C @ 23°C, drift ±0.03°C/°C Isolation
Operating Temperature: -40 to 85°C Isolation: Input/out put isolated to 500 Vrms
Storage Temperature: -40 to 100°C (tested to 1.2K Vrms)
Response Time: 0.5 seconds for 98% change
CMRR: Better than 120 dB (60Hz) Classification
Ripple: Less than 0.05% Vrms of span Classification: General Purpose CSA approval pending
RFI Protection (option): Input and Output connections AC
de-coupled to ground
Dimensions
Size: WxHxL = 0.89”W x 3.15”H x 5.41”L
T/C Burnout Detection (22.55mm x 80mm x 137.5mm)
Direction: Upscale (standard)
Weight: 6.5 ounces (184.3 grams)
Downscale (optional, field changeable)

Power Supply Model XZ12-A Transmitter Specifications


Power Supply: 12 – 60 Vdc
Inputs
Isolation Frequency Range: 50 – 400 Hz
Isolation: Input/output isolated to 500 Vrms Span: 100 mVrms minimum – 300 Vrms
(tested to 1.2K Vrms) maximum or 20 mArms minimum
-5 Arms maximum
Classification (±10% adjustable, factory configured)
Classification: General Purpose CSA approval Zero: 5 mVrms minimum – 300 Vrms
pending maximum or 0 Arms minimum
-5 Arms maximum
Dimensions (±10% adjustable, factory configured)
Size: WxHxL = 0.89”W x 3.15”H x 5.41”L Burden Voltage: 150 mVrms maximum
(22.55mm x 80mm x 137.5mm) (current input)
Weight: 6.5 ounces (184.3 grams) Input Impedance: 1M minimum
(voltage input)
Model XZ12-D Transmitter Specifications
Output
Inputs Standard: 4 – 20 mA
Span: 5 mV minimum – 150 V maximum or Optional: 10 – 50 mA
1.0 mA minimum – 5 A maximum
(±10% adjustable, factory configured)
Zero: -10 V minimum – 150 V maximum or
Load Resistance
Vsupply – 12 V
0 A minimum – 5 A maximum RL= 20 mA (or 50 mA)
(±10% adjustable, factory configured)
Burden Voltage: 150 mV maximum
(current input) Performance
Input Impedance: 1M minimum Accuracy: ±0.25% of span
(voltage input) Temperature Effect:
(-40 to 85°C) 0.02%/°C of span
Output
Standard: 4 – 20 mA
Optional: 10 – 50 mA
XZ12 Specifications

Model XZ12-A Transmitter Specifications Model XZ12-V Transmitter Specifications


(continued) (continued)

Performance (continued) Power Supply


Operating Temperature: -40 to 85°C Power Supply: 12 – 60 Vdc
Storage Temperature: -40 to 100°C
Response Time: 0.5 seconds for 98% change
CMRR: Better than 120 dB (60Hz)
Isolation
Isolation: Input/output isolated to 500 Vrms
Ripple: Less than 0.05% Vrms of span
(tested to 1.2K Vrms)
RFI Protection (option): Input and Output connections AC
de-coupled to ground
Classification
Classification: General Purpose CSA approval pending
Power Supply
Power Supply: 12 – 60 Vdc
Dimensions
Size: WxHxL = 0.89”W x 3.15”H x 5.41”L
Isolation (22.55mm x 80mm x 137.5mm)
Isolation: Input/output isolated to 500 Vrms
Weight: 6.5 ounces (184.3 grams)
(tested to 1.2K Vrms)

Classification Model XZ12-R Transmitter Specifications


Classification: General Purpose CSA approval pending
Inputs
Dimensions Resistance: 3-Wire Resistance Potentiometer or
Size: WxHxL = 0.89”W x 3.15”H x 5.41”L Slidewire 0-100 through 0-10K
(22.55mm x 80mm x 137.5mm) Span: 100 minimum – 10K maximum
Weight: 6.5 ounces (184.3 grams) (±10% adjustable, factory configured)
Zero: 0 minimum – 10K maximum
Model XZ12-V Transmitter Specifications (±10% adjustable, factory configured)
Excitation Voltage: 80 – 500 mV
Inputs Bias Current: 60 µA – 800 µA
RTD: 3-Wire Resistance Bulb Sensor
Pt100, Ni120, Cu10 Output
Span and Zero: 10 - 500 (adjustable to ±10%, Standard: 4 – 20 mA
factory configured) Optional: 10 – 50 mA
Minimum span (10 )
Pt100 – 26°C Load Resistance
Ni120 - 18°C Vsupply – 12 V
Cu10 - 260°C RL=
20 mA (or 50 mA)
Excitation Current: Constant current of 0.3 – 0.45 mA
maximum
Leadwire Resistance Effect: Negligible up to 20% of nominal
Performance
Accuracy: ±0.1% of span
resistance
Temperature Effect:
Linearization (ZL option): Pt100 only ±0.2% of span
(-40 to 85°C) 0.01%/°C of span
(factory configured)
Operating Temperature: -40 to 85°C
Storage Temperature: -40 to 100°C
Output Response Time: 0.5 seconds for 98% change
Standard: 4 – 20 mA CMRR: Better than 120 dB (60Hz)
Optional: 10 – 50 mA Ripple: Less than 0.05% Vrms of span
RFI Protection (option): Input and Output connections AC
Load Resistance de-coupled to ground
Vsupply – 12 V
RL= 20 mA (or 50 mA) Power Supply
Power Supply: 12 – 60 Vdc
Performance
Accuracy: ±0.1% of span Isolation
Temperature Effect: Isolation: Input/output isolated to 500 Vrms
(-40 to 85°C) 0.01%/°C of span + 1M / °C (tested to 1.2K Vrms)
Operating Temperature: -40 to 85°C
Storage Temperature: -40 to 100°C
Response Time: 0.5 seconds for 98% change
Classification
Classification: General Purpose CSA approval pending
CMRR: Better than 120 dB (60Hz)
Ripple: Less than 0.05% Vrms of span
RFI Protection (option): Input and Output connections AC Dimensions
de-coupled to ground Size: WxHxL = 0.89”W x 3.15”H x 5.41”L
(22.55mm x 80mm x 137.5mm)
Weight: 6.5 ounces (184.3 grams)
Side View Front View

(supports both 35mm and G DIN rail mounting)

Ordering Information
Wiring Diagrams
When ordering, specify the following:

XZ12-____-____-____-____-____
input output option 1 option 2 option 3

Input: T = Thermocouple, (specify type: B, J, K, E,


R, S, T or N and Range in F or C)
D = DC current or voltage
(specify zero and span)
A = AC current or voltage
(specify zero and span)
V = RTD (specify type: Pt100, Ni120, or Cu10)
R = Resistance (specify span and zero,
0 through 10K )

Output: 4 – 20 mA or 10 – 50 mA

Options:
RFI Protection: -ZR
Pt100 linearization: -ZL (XZ12-V only)
Downscale burnout: -ZB (XZ12-T only)
Reverse Output: -ZJ
Represented By:

M EASUREMENT TECHNOLOGIES, LTD.


1900 Industrial Blvd., Suite 200
Colleyville, TX 76034 USA
Tel: +817-442-9930
Fax: +817-442-9990
Email: sales@mtech.biz
Web Site: www.mtech.biz Specifications are subject to change without notice
XZ12 Rev 1/081302