server IP

Description Front view


The server IP device is part of the devices of the hotel offer and must be used when
designing or installing systems with over 100 rooms, or areas with over 100 MH201 1
installed.

Default configuration
Network configuration IP = 192.168.1.51
Netmask: 255.255.255.0 2
DHCP and DNS default range
in the “MyHOME_Suite” software vers. 2.0.91: 192.168.1.52 – 192.168.5.49 3
Password OPEN: 12345

Technical data
Power supply: 18 – 30 Vdc
Absorption: 55 mA max DC
Minimum consumption: 1.3 W
Maximum consumption: 3.3 W
Holding Date and time without power supply: 48 hours
Operating temperature: 5 – 45 °C 4

Standards, Certifications, Marks Legend


EN 60669-2-1 1. RJ45 connector for Ethernet LAN 10/100 Mbit
EN 50491-5-1 2. Mini-USB connector for the configuration using the PC and software update
EN 50428
3. LED notifications
System LED: it comes on when connecting the power supply, and then it
goes off.
Dimensional data
When it later comes back on steady, it means that the device is
Size: 6 DIN modules working correctly
Speed LED: speed of connection to the network:
ON = 100 Mbit
Configuration OFF = 10 Mbit
The device must be configured using the “MyHOME_Suite” software. Link LED: when on, it indicates that the Ethernet network has been found
4. Power supply connection clamps (recommended 346020)

MM00857-a-EN 15/01/2015

1
BUS-SCS F458
server IP

Wiring diagrams

Typical diagram of a system with less than 100 areas (rooms + common areas) and one supervision PC.

Hotel Rooms
ROOM 99 ROOM 100

MH201 MH201

Switch layer 3

MH201 MH201

ROOM 3 ROOM 4

MH201 MH201

Switch layer 3

MH201

ROOM 1 ROOM 2

MH201 MH201

Switch layer 3

MH201 MH201

Hotel management PMS interface


supervision software

Switch layer 3

Layer 3 switch or Router

Dedicated BTicino/Legrand VLAN

Ethernet network

MM00857-a-EN 15/01/2015

2
BUS-SCS F458
server IP

Wiring diagrams

Typical diagram of a system with 100 to 500 areas (rooms + common areas) and one supervision PC.

Hotel Rooms
ROOM 499 ROOM 500

MH201 MH201

Switch layer 3

MH201 MH201

ROOM 99 ROOM 100

MH201 MH201

Switch layer 3

MH201 MH201

ROOM 1 ROOM 2

MH201 MH201

Switch layer 3

MH201 MH201

Hotel management PMS interface


supervision software

Switch layer 3

Layer 3 switch or Router

230 V

PR I

346020
PRI: 220 - 240V~
175-165mA
50/60Hz
1-2: 27Vdc
600mA

DC
1- 2
Power supply
346020
IP SERVER
F458
Dedicated BTicino/Legrand VLAN

Ethernet network

MM00857-a-EN 15/01/2015

3
BUS-SCS F458
server IP

Wiring diagrams

Typical diagram of a system with up to 500 areas (rooms + common areas) and up to 10 supervision PCs.

Hotel Rooms
ROOM 499 ROOM 500

MH201 MH201

Switch layer 3

MH201 MH201

ROOM 99 ROOM 100

10° PC
Hotel management
supervision software
MH201 MH201

Switch layer 3

MH201 MH201

ROOM 1 ROOM 2
1° PC
Hotel management
supervision software
Supervision server

MH201 MH201

Switch layer 3

MH201 MH201

PMS interface

Switch layer 3

Layer 3 switch or Router


230 V

PR I

346020
PRI: 220 - 240V~
175-165mA
50/60Hz
1-2: 27Vdc
600mA

DC
1- 2
Power supply
346020
IP SERVER
F458
Dedicated BTicino/Legrand VLAN

Ethernet network

MM00857-a-EN 15/01/2015

You might also like