Note: All affected precast girders must be active and statically determinately supported.
Setting Description
Action Code of the selected Action. It is possible to switch to another action without
leaving and reentering the input function.
Action will be The action will be skipped in the calculation process if the option is selected.
skipped (Option)
Input1 > Tendon Tendon series to be processed (not necessary if tendons defined with RmSet)
From/To/Step
Input2 > RmSet Name of the RmSet or Assembly containing the tendons to be processed
or Assembly (not necessary if tendons directly defined in Input1).
Note: If tendons are specified via RmSet/Assembly as well as directly in
Input1, both definitions will be considered; i.e. all tendons defined in the
RmSet/Assembly, and additionally all tendons specified in Input1
irrespective of being part of the RmSet/Assembly will be processed.
Input3 > Factor Factor for reducing the effective elasticity modulus of the concrete in the
for Emod calculation of effective prestressing forces (losses due to elastic shortening).
This allows for taking into account that formwork removal is done before the
nominal modulus of elasticity (28 days modulus) has been reached.
Default: 1.0 (nominal modulus of the concrete material is effective)
Output1 > Load Name of the created load case, where the results of the calculation will be
case name stored.
Note: If the load case has not been previously defined in the load case
definition function, it will get the flag "NonPermanent" and no load case
category label for the load manager. I.e. it is strongly recommended that the
load case be previously defined in the load case definition menu with
appropriate flags.
Related reference
Choice of RmSet/tendon series
mk:@MSITStore:C:\Program%20Files\Bentley\RMBridge\v11.04.00.17\rmev10\rm9e... 29/6/2020
Action > PreTens Page 2 of 2
mk:@MSITStore:C:\Program%20Files\Bentley\RMBridge\v11.04.00.17\rmev10\rm9e... 29/6/2020