Professional Documents
Culture Documents
Where
P=MAXIMUM ALLOWABLE OPERATING PRESSURE( PSI)
D=OUTSIDE DIAMETER OF PIPE(INCH)
S= ALLOWABLE STRESS VALUE (PSI) FROM TABLE A-1
E=QUALITY FACTOR FROM TABLE A-1A OR A-1B(JOINT EFFICIENCY)
Y= COEFFICIENT FROM TABLE 301.1.1
C=CORROSION ALLOWANCE(INCH)
WORKING TEMPERATURE = 0
F
Page 2 OF 3 536762237.xlsx
Client SAUDI ARAMCO
Subject PIPE WALL THICKNESS CALCULATION BI/JO.
Based on ASME B 31.3 Drawing No..
Computer ZAHID Chk'd. By App'd By Date 29-Oct-2013 Rev. A
CALCULATIONS:
THE PIPE WALL THICKNESS PER CODE B31.3 IS,
PIPE W.T, t = PXD = 816 = 0.029 Inch.
2 ( SE + PY) 28440.8
THE MINIMUM PIPE THICKNESS REQUIRED CONSIDERING CORROSION AND
THREADING ALLOWANCES IF ANY
PIPE W.T, tn = tm
0.875
PIPE W.T, tn = 0.1699 Inch
THE SELECTED PIPE WALL THICKNESS WILL BE 0.179 INCH. i.e SCHEDULE 80.
Page 2 OF 3 536762237.xlsx
CALCULATION AND PIPE WALL THICKNESS PER ASME B31.3
Page 3 of 4 536762237.xlsx
CALCULATION AND PIPE WALL THICKNESS PER ASME B31.3
Page 4 of 4 536762237.xlsx