1 CALCULO DE PRESION DE DISEÑO 2.

CALCULO DE ESPESOR

P DISENO= 2*S*t (F*L*J*T) t= Pdiseno*Do


Do 2*S

DATOS:

S= Esfuerzo de fluencia Pdiseno= 1000


t= Espesor Do= 20.00
Do= Diametro exterior S= 37450.00
F= factor de diseno
L= factor de ubicacion
J= Factor de junta t= 0.26702269692924
T= factor de correcion por temp.
12.5
0.0625
DATOS: 0.03337783711615
0.36290053404539
Tuberia 20" API 5L X52

S= 52000.00
t= 0.375
Do= 20.00
F= 0.72
L= 0.90
J= 1.00
T= 1.00

PRESION 1263.6 psi


psi
pulg

pulg
API Standard para tubería 5LX:
– Specified Minimum Yield Strength (p
–API 5LX Grade X42
–API 5LX Grade X46
–API 5LX Grade X52
–API 5LX Grade X56
–API 5LX Grade X60
–API 5LX Grade X65
–API 5LX Grade X70
–API 5LX Grade X80
–API 5LX Grade X90
ard para tubería 5LX:
nimum Yield Strength (psi)
42,000 psi
46,000 psi
52,000 psi
56,000 psi
60,000 psi
65,000 psi
70,000 psi
80,000 psi
90,000 psi
 Factor de ubicación (Location):
Class 1 Deserted L= 1.0
Class 2 Village L = 0.
Class 3 City L = 0.
Class 4 City (densely populated) L = 0.
ASME RECOMMENDED VALUES:
Class 1 L= 0.72
Class 2 L = 0.60
Class 3 L = 0.50
Class 4 L = 0.40
FACTOR DE JUNTA O SOLDADURA:
Seamless F = 1.00
Electric welded F = 1.00
Submerged arc welded F = 1.00
Furnace butt welded F = 0.60
FACTOR DE CORRECCION DE TEMPERATURA PARA
GAS:
Hasta 250ºFT = 1.00
300T = 0.97
350T = 0.93
400T = 0.91
450T = 0.87
tion):
L= 1.00
L = 0.90
L = 0.70
L = 0.55

ATURA PARA LINEAS DE