You are on page 1of 1

SCHEDULE OF COLUMNS

C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 25mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm

THIRD FLOOR

LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS
TO
1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150

ROOF BEAM

300
#20 #20
250

250

250

250

250

250

250

250

250

250

250

250

250

250

250

250
200

200

200
#16 #16 #16 #20 #16 #16 #20 #16 #16 #16 #16 #16 #16 #16 #16 #16 #16 #16 #16 #16
400 250 400 500 400 400 400 400 400 400 400 400 500 400 400 250 400 400 400 400

6-#16 4-#16 6-#16 8-(2#20) 6-#16 6-#16 10-#20 6-#16 6-#16 6-#16 6-#16 4-#20 + 4-#16 4-#20 + 2-#16 6-#16 6-#16 4-#16 6-#16 6-#16 6-#16 6-#16
C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 25mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 25mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm

SECOND FLOOR

LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS
TO
1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150

THIRD FLOOR

300

300
#20 #20 #20 #20 #20
250

250

250

250

250

250

250

250

250

250

250

250
200

200

200
#16 #16 #20 #16 #16 #16 #20 #20 #16 #16 #16 #20 #16 #16 #16 #16 #20
400 250 500 400 400 400 400 300 400 400 400 500 400 400 250 400 400

6-#16 4-#16 8-(2#20) 6-#16 4-#20 + 2-#16 4-#20 + 2-#16 10-#20 4-#20 4-#20 + 2-#16 6-#16 4-#20 + 4-#16 8-(2#20) 6-#16 6-#16 4-#16 4-#20 + 2-#16 8-#20
C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm

UPPER GROUND
FLOOR

LINKS LINKS LINKS LINKS LINKS LINKS LINKS LINKS


TO
1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150

SECOND FLOOR
FLOOR

300

300

300
250 #20 #20 #20 #20 #20

250

200

200

200
#16 #16 #20 #20 #16 #16 #16 #16
400 400 300 400 300 400 400 450

4-#20 + 2-#16 4-#20 + 2-#16 4-#20 10-#20 4-#20 + 4-#16 4-#20 + 2-#16 6-#16 4-#20 + 6-#16
C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm

LOWER GROUND
FLOOR

LINKS LINKS LINKS LINKS LINKS


TO
1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150

UPPER GROUND
FLOOR
300

300

300
#20 #20 #20
250

250

#16 #16 #20 #20 #16


400 400 300 400 300

4-#20 + 2-#16 4-#20 + 2-#16 4-#20 C21 : Fy41510-#20


, COVER = 40mm 4-#20 + 4-#16
C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm C21 : Fy415 , COVER = 40mm

FOUNDATION

LINKS
LINKS LINKS LINKS 1@50, 8@80, REST @ 150 LINKS
TO
1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150 1@50, 8@80, REST @ 150

LOWER GROUND
300

FLOOR #20
300

300
#20 #20
250

250

400
#16 #16 #20 #20
400 400 300 10-#20 300

4-#20 + 2-#16 4-#20 + 2-#16 4-#20 8-#20

COLUMN
C1 C4 C6 C7 C8 C11 C12 C13 C14 C15 C19 C23 C25 C26 C27 C28 C30 C32 C33 C34 C35 C36 C37 C38
MARKED

WALL FOOTING SCHEDULE STAIR REINFORCEMENTS SCHEDULE ISOLATED FOOTING SCHEDULE


BOTTOM REINFORCEMENT TOP REINFORCEMENT EMBEDMENT BOTTOM REINFORCEMENT TOP REINFORCEMENT ANTICRACK BOTTOM REINFORCEMENT TOP REINFORCEMENT EMBEDMENT
MARK WIDTH THICKNESS TYPE MARK LENGTH WIDTH THICKNESS TYPE
TRANSVERSE LONGITUDINAL TRANSVERSE LONGITUDINAL DEPTH MARK TRANSVERSE LONGITUDINAL TRANSVERSE LONGITUDINAL BENT BARS TRANSVERSE LONGITUDINAL TRANSVERSE LONGITUDINAL DEPTH

STAIRS-01 10mm @ 300mm 12mm @ 150mm 10mm @ 300mm 10mm @ 300mm 10mm @ 300mm 16mm @ 200mm 16mm @ 200mm 16mm @ 400mm 16mm @ 400mm
F-1 1400 1400 350 CONCENTRIC 900
WF-1 800 350 16mm @ 200mm 16mm @ 400mm 16mm @ 400mm 16mm @ 400mm CONCENTRIC STRIP 900 10mm @ 300mm 16mm @ 120mm 10mm @ 300mm 10mm @ 240mm 10mm @ 240mm
STAIR-02
F-2 1000 1000 300 16mm @ 300mm 16mm @ 300mm 16mm @ 400mm 16mm @ 400mm CONCENTRIC 700
STAIRS-03 10mm @ 300mm 12mm @ 150mm 10mm @ 300mm 10mm @ 300mm 10mm @ 300mm
WF-2 800 300 16mm @ 300 16mm @ 400mm 16mm @ 400mm 16mm @ 400mm CONCENTRIC STRIP 700
STAIR-04 10mm @ 300mm 16mm @ 120mm 10mm @ 300mm 10mm @ 240mm 10mm @ 240mm
WALLS SCHEDULE
WF-3 1400 300 16mm @ 300 16mm @ 400mm 16mm @ 400mm 16mm @ 400mm ECCENTRIC STRIP 700
MARK THICKNESS LONGITUDINAL BARS TRANSVERSE REINFORCEMENTS

12mm @ 300 12mm @ 400mm 12mm @ 400mm 12mm @ 400mm STEPPED 10mm SPACED 1@50, 8@100, REST @ 200
WF-4 1000 200 700
ECCENTRIC 12mm @ 150mm @ L/6 ENDS, 12mm @ 200mm @ MIDDLE 2L/3
W-1 250
(add closed ties at for longitudinal bars @ MIDDLE 2L/3)
CHECK ELEVATOR
MF-1 VERIFY ON PLAN 350 16mm @ 200mm 16mm @ 200mm 16mm @ 300mm 16mm @ 300mm MAT
REQUIREMENT W-2 200 12mm @ 200mm @ L/6 ENDS, 12mm @ 300mm @ MIDDLE 2L/3 10mm SPACED 1@50, 5@100, REST @ 200

STAIR-FOOTING 500 250 16mm @ 200mm 16mm @ 200mm - - CONCENTRIC STRIP 200

CIVIL ENGINEER IMPORTANT NOTES OWNER / CLIENT PROJECT TITLE SHEET CONTENTS REVISIONS PROJECT STATUS PROJECT NO.
AS SHOWN
IN PURSUANCE WITH THE PROVISIONS ON RA 9266, SEC 33, DRAWINGS AND
SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS DULY SIGNED,
PO RESIDENCE FOR BUILDING PERMIT
STAMPED OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE

DE CHAVEZ DESIGNS
ENGR. JOSEPH B. PONCE INTELLECTUAL PROPERTY AND DOCUMENTS OF THE ARCHITECT, WHETHER
THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT SHALL BE
DRAWN BY: HAPEE DATE: SHEET NO.
UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID LOCATION
INTERNATIONAL
Unit 18 & 19, Flr 17, Robinsons Victoria Tower C, Timog
REGISTERED CIVIL ENGINEER
DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS MRS. LUZBELLA PO
Corner Panay Avenue, Barangay Paligsahan, Quezon City, OR BUILDINGS, WHETHR EXECUTED IN PART OF IN WHOLE, WITHOUT THE REVISED BY: DATE:
Metro Manila PRC ID# 0161332 PTR: 0782747 OWNER / CLIENT BLK 11, LOT 19, MARINA DRIVE, PENINSULA DE PUNTA FUEGO,
Contact :02-7943-2840
dechdez.international@gmail.com
arkidomdevcorp@gmail.com DATE: 01/15/2021 PLACE: QUEZON CITY
WRITTEN CONSENT OF THE ARCHITECT OR AUTHOR OF THE SAID
DOCUMENTS BARANGAY BALAYTIGUE, NASUGBU, BATANGAS, CALABARZON
CHECKED BY: DATE: S-8

D:\2021-03-16_ParaDraft\2021-04-09_ENGR. JOSEPH\2021-04-10_PO\CAD\2021-05-05_PO-STRUCTURAL-OUT-11.dwg, 5/5/2021 2:52:01 AM