Design Features
• Intuitive user interface featuring an advanced backlit
display and Chinese language option
• Comprehensive data logging in non-volatile memory
with real-time clock
ELB Detection System
• Manual reset option to maintain Process Shutdown (PSD) for Pipeline Monitoring
position until human intervention allows a return to and Valve Control
normal operation
• Pressure monitoring with RoD and RoR calculation
• Configurable PSD position to Open, Close, or Stay-in-place
• Configuration and data retrieval via Rotork Bluetooth®
Setting Tool or PC (using Rotork Insight 2™)
• Will operate on 9-28 VDC supply voltage
• Local controls OPEN, CLOSE, LOCAL / REMOTE / STOP
• Remote control available via either hard-wired connections
or Modbus® serial communication protocol
• Partial stroke available
• Provision for up to six remote inputs
• Optional position sensor input
• Up to four configurable solenoid outputs
• Rotork designed hazardous area enclosure
• Can be mounted either on the actuator or remotely
• Compatible with a variety of actuator types
The enclosure is approved to IP68. Using a Rotork Bluetooth® Delays RoD / RoR trip until alarm condition is present for at
Setting Tool Pro, no covers need to be removed for least a specified amount of time.
commissioning, adjusting, analysis, or accessing data logs. Time adjustment from 0 - 1,800 seconds, default 30 sec.
Independent Rate of Pressure Drop (RoD) and Note: All functions may be individually disabled to allow
Rate of Pressure Rise (RoR) the customer to capture pressure data using the datalogger
RoD/RoR slope check can be set to occur every sample, over a period of weeks, and then use this data to determine
or at any multiple of samples (1-60). appropriate trip set points.
Real time clock / calendar with backup power • When a second sensor is configured for error checking
via supercapacitor the first sensor, should the two pressures deviate from
each other by more than the allowable alarm setting,
the indication relay shall be triggered.
Alarms
Indication relays triggered by: Fault relay triggered by:
• Alert level - high pressure set point* • Alarm level - high pressure set point*
• Alert level - low pressure set point* • Alarm level - low pressure set point*
• Alert level - rate of drop (RoD) set point* • Alarm level - rate of drop (RoD) set point*
• Alert level - rate of rise (RoR) set point* • Alarm level - rate of rise (RoR) set point*
• Hardware fault • An active PSD condition
• Memory error • High differential pressure across the valve
• Pressure transmitter out of range
• Two pressure transmitters out of sync.* All triggers may be individually disabled in the
configuration software.
• Over voltage on battery supply power*
*Configurable
Typical Configuration
Solar Array
Electronic Line Break (ELB) Scope & Battery
( 9–28 VDC )
Network – Modbus Power Input
• Status polling & Conditioning
• Remote control Datalogger
LCD Display Non-Volatile
Remote Control Input Memory
• Open 10
20 30
40 50 60 70
80
90
• Close 0 100
DCB • PSD
Local configuration
PLC • Remote Reset
• Setting tool
RTU • Partial Stroke
• Bluetooth
• Remote Maintain
• Bluetooth
Customer Indication
• Monitor Relay Local Open
• Fault Relay Remote Close
• 2 Reconfigurable
Relays
Limit Switch
Box
SOV1 SOV2
Energise to Energise to
Open Close
Pressure Pressure
Sensor 1 Sensor 2
(optional)
DOWNSTREAM UPSTREAM
MAIN VALVE
Dimensions (mm)
197 197 Ø 8.5 Ø 8.5
Maximum Weight is 9kg
197 Ø 8.5
172
172172
CABLE ENTRY
CABLE ENTRY CABLE ENTRY
CABLE ENTRY
CABLE ENTRY CABLE ENTRY
CABLE ENTRY
CABLE ENTRY
(MAINS SUPPLY)
(MAINS SUPPLY)
CABLE ENTRY
(MAINS SUPPLY)
329329
on our website. email mail@rotork.com Fluid Power Actuators and Control Systems
Gearboxes and Gear Operators
Precision Control and Indication
Projects, Services and Retrofit
www.rotork.com
PUB127-001-00 As part of a process of on-going product development, Rotork reserves the right to amend Rotork is a corporate
and change specifications without prior notice. Published data may be subject to change. member of the Institute
Issue 01/18 For the very latest version release, visit our website at www.rotork.com of Asset Management
The name Rotork is a registered trademark. Rotork recognises all registered trademarks.
Published and produced in the UK by Rotork. POW TG0818