You are on page 1of 14

SIZE DWG NO SH REV

A4 113A7969 1 D

Item Item
Devices Designation
PID TG
Solenoid valve for VA18-1 control.
0425 20AA-1 0983 Characteristics: Normal : 1 to 3 open ; 2 closed.
35 W | 125 VDC
Solenoid valve for VA22-1 control.
0425 20AB-1 0922 Characteristics: Normal : 1 to 3 open ; 2 closed.
35 W | 125 VDC
Compressor Bleed Solenoid Valve
0417 20CB-1 1071
Characteristics: Normal : B to C Open ; A closed
Fuel pump clutch solenoid
0424 20CF-1 0601 Characteristics: Normal : NO
160W(max) | 100-125VDC
Trip Solenoid Valve for Gas Control Valve (VGC-1)
0422 20FGC-1 0509 Characteristics : Normal : NO
125 VDC
Fuel Gas Stop Valve Solenoid Valve
0422 20FGS-1 0507 Characteristics : Normal : NO
125 VDC
Liquid fuel stop gas solenoid
0424 20FL-1 1019
Characteristics: Normal : NO
Solenoid valve. Command the VA99-32 valve
0494 20IA-31 E021 Characteristics: Normal : 1 to 2 closed.
12 W | 125 VDC |
purge fuel liquid solenoid valve
0424 20PF-100 0961
Characteristics : Normal : port OH4 closed
Solenoid valve for VA13-1 control.
Characteristics: Normal : 1 to 3 open ; 2 closed.
0477 20PG-1 0918
35 W | 125 VDC
Settings: A Needle-Valve is installed upstream of 20PG-1 in order to adjust VA13-1 Time Opening at 30 seconds.
Solenoid valve for VA13-2 control.
Characteristics: Normal : 1 to 3 open ; 2 closed.
0477 20PG-2 0918
35 W | 125 VDC
Settings: A Needle-Valve is installed upstream of 20PG-1 in order to adjust VA13-1 Time Opening at 30 seconds.
Solenoid valve for VA19-1 control.
0477 20PL-1 918T Characteristics: Normal : 1 to 3 open ; 2 closed.
35 W | 125 VDC
Torque Converter Fill / Drain Solenoid Valve
0421 20TU-1 0605
Characteristics: Normal : NC
Turbine compressor IGV solenoid valve
0469 20TV-1 1019
Characteristics: Normal : NO
Motor Valve Off-Line Compressor Water Wash
0442 20TW-1 0953 Characteristics: 92 W | 115 VAC | 50 Hz | 1 PH |
Fail safe to close
Motor Valve Turbine Water Wash
0442 20TW-2 0983 Characteristics: 230 W | 115 VAC | 50 Hz | 1 PH |
Fail safe to close
Motor Valve On-Line Compressor Water Wash
0442 20TW-3 0953 Characteristics: 92 W | 115 VAC | 50 Hz | 1 PH |
Fail safe to close
Fuel Gas Vet solenoid Valve
0422 20VG-1 0911 Characteristics: Normal : NO
125 VDC
Vent Solenoid Valve of inter-valve cavity VA13-1 and VA13-2.
0477 20VG-2 0918 Characteristics: Normal : NO
125 W | 125 VDC
Solenoid valve for Water Injection Control valve VC4-1
0462 20WN-1 A035
Characteristics : Normal : NO
Motor space heater for 88AB-1
0425 23AB-1 1047
Characteristics: 0.05 kW | 230 VAC | 50 Hz | 1 PH |
Anti-condensation heater for motor 88BT-1
0436 23BT-1 1605
Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH |
Anti-condensation heater for motor 88BT-2
0436 23BT-2 1605
Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH |
Cranking Motor Space Heater
0421 23CR-1 0603
Characteristics: 180 W | 230 VAC | 50 Hz | 1 PH |

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 1
SIZE DWG NO SH REV
A4 113A7969 2 D

Item Item
Devices Designation
PID TG
Cranking Motor Space Heater
0421 23CR-2 0603
Characteristics: 180 W | 230 VAC | 50 Hz | 1 PH |
Cranking Motor Space Heater
0421 23CR-3 0603
Characteristics: 180 W | 230 VAC | 50 Hz | 1 PH |
Accessory compartment heater
0436 23HA-1 1137
Characteristics: 18 kW | 400 VAC | 50 Hz | 3 PH |
Heater hydraulic oil pump motor
0434 23HQ-1 0628
Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH |
Acoustic TG enclosure Heater
0436 23HT-1 1605
Characteristics: 18 kW | 400 VAC | 50 Hz | 3 PH |
Air inlet water injection compartment heater
0436 23JS-3 1605
Characteristics : 5 kW | 400 VAC | 50 Hz | 3 PH |
Air inlet water injection compartment heater
0436 23JS-4 1605
Caractéristiques : 5 kW | 400 VAC | 50 Hz | 3 PH |
Motor space heater for 88QA-1
0416 23QA-1 1006
Characteristics: 0.05 kW | 230 VAC | 50 Hz | 1 PH |
Immersion heater Lube Oil Tank
0416 23QT-1 0938
Characteristics: 10,2 kW | 400 VAC | 50 Hz | 3 PH |
Immersion heater Lube Oil Tank
0416 23QT-2 0938
Characteristics: 10,2 kW | 400 VAC | 50 Hz | 3 PH |
Anti-condensation heater of 88QV-1
0416 23QV-1 A098
Characteristics: 0.05 kW | 230 VAC | 50 Hz | 1 PH |
Turning Gear Motor Space Heater
0421 23TG-1 0603
Characteristics: 0.05 kW | 230 VAC | 50 Hz | 1 PH |
Anti-condensation heater for motor 88TK-2
0417 23TK-1 1233
Characteristics: 0.05 kW | 230 VAC | 50 Hz | 1 PH |
Anti-condensation heater for motor 88TK-2
0417 23TK-2 1233
Characteristics: 0.05 kW | 230 VAC | 50 Hz | 1 PH |
Anti-condensation heater for motor 88WN-1
0462 23WN-1 A035
Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH |
Water injection compartment heater
0436 23WR-1 1605
Caractéristiques : 3 kW | 400 VAC | 50 Hz | 3 PH
Water injection compartment heater
0436 23WR-2 1605
Caractéristiques : 3 kW | 400 VAC | 50 Hz | 3 PH
Thermostat, lower temperature in accessory compartment
0436 26HA-1 1137 Characteristics: Normal : NO; measure range : 2 to 50C° (35,6 to 122°F)
Settings : 15°C
Thermostat, low temperature in acoustic enclosure
0436 26HT-1 1605 Characteristics: Normal : NO ; measure range : 2 to 50C° (35,6 to 122°F)
Settings : 15°C
Water injection compartment heater
0436 26WR-1 1605
Settings : +10°C mini
0415 28FD-10 1121 Flame detector chamber 10
0415 28FD-11 1121 Flame detector chamber 11
0415 28FD-4 1121 Flame detector chamber 4
0415 28FD-5 1121 Flame detector chamber 5
Diagnostic ignition exciter switch
0415 30SG-1 1213 Characteristics : Normal : NO
125 VDC
GT enclosure ventilation damper limit switch
0436 33BT-1 1605 Characteristics: Normal : NO
Settings: damper closed : limit switch activated and contact closed
GT enclosure ventilation damper limit switch
0436 33BT-2 1605 Characteristics: Normal : NO
Settings: damper closed : limit switch activated and contact closed
11 stage compressor Bleed Valve Limit Switch
0417 33CB-1 1022 Characteristics: Normal : NO
Settings: Valve open : limit switch activated, contact closed
11 stage compressor Bleed Valve Limit Switch
0417 33CB-2 1022 Characteristics: Normal : NO
Settings: Valve open : limit switch activated, contact closed
11 stage compressor Bleed Valve Limit Switch
0417 33CB-3 1022 Characteristics: Normal : NO
Settings: Valve open : limit switch activated, contact closed

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 2
SIZE DWG NO SH REV
A4 113A7969 3 D

Item Item
Devices Designation
PID TG
11 stage compressor Bleed Valve Limit Switch
0417 33CB-4 1022 Characteristics: Normal : NO
Settings: Valve open : limit switch activated, contact closed
Liquid fuel stop valve limit switch (bc)
0424 33FL-1 0511 Characteristics: Normal: NO
Settings: Valve closed : switch actuated, contact closed
Water injection compartment ventilation damper limit switch
0436 33JS-1 1605 Characteristics: Normal : NO
Settings: damper closed : limit switch activated and contact closed
Water injection compartment ventilation damper limit switch
0436 33JS-2 1605 Characteristics: Normal : NO
Settings: damper closed : limit switch activated and contact closed
purge fuel liquid valve limit switch VP-1
0424 33PF-1 0961 Characteristics : Normal : NO
Settings : Valve closed : switch actuated and contact closed
purge fuel liquid valve limit switch VP-2
0424 33PF-2 0961 Characteristics : Normal : NO
Settings : Valve closed : switch actuated and contact closed
VA13-1 Close Position Limit Switch.
0477 33PG-1 0918 Characteristics: Normal: NO
Settings: Valve closed : switch actuated, contact closed.
VA13-1 Open Position Limit Switch.
0477 33PG-2 0918 Characteristics: Normal: NO
Settings: Valve open : switch actuated, contact closed
VA13-2 Close Position Limit Switch.
0477 33PG-3 0918 Characteristics: Normal: NO
Settings: Valve closed : switch actuated, contact closed.
VA13-2 Open Position Limit Switch.
0477 33PG-4 0918 Characteristics: Normal: NO
Settings: Valve open : switch actuated, contact closed
Torque Converter Solenoid Valve Limit Switch
0421 33TC-1 0605 Characteristics: Normal : NO
Settings: Switch activated with 20TU-1 de energized – Contact closed
Torque Converter Low Torque Limit Switch
0421 33TM-5 0605
Settings: Setup at 2 tr (range 0-31 tr)
Torque Converter High Torque Limit Switch
0421 33TM-6 0605
Settings: Setup at 28 tr (range 0-31 tr)
Load compartment ventilation damper limit switch
0436 33VG-1 1605 Characteristics: Normal : NO
Settings: damper closed : limit switch activated and contact closed
Limit Switch on Solenoid Valve 20VG-1
0422 33VG-11 0911 Characteristics: See specifications
Settings: Valve open :limit switch activated and contact closed
Load compartment ventilation damper limit switch
0436 33VG-2 1605 Characteristics: Normal : NO
Settings: damper closed : limit switch activated and contact closed
VC4-1 control valve limit switch
0462 33WN-1 A035 Characteristics: Normal: NO
Settings: Valve full opened = limit switch actuated, contact closed.
VC4-1 control valve limit switch
0462 33WN-2 A035 Characteristics: Normal: NO
Settings: Valve full closed = limit switch actuated, contact closed.
Vibration Sensor
0415 39V-1A 1218
Characteristics: For 25,4 mm/s (1 in/s), 150 ± 4,5 mV peak
Vibration Sensor
0415 39V-1B 1218
Characteristics: For 25,4 mm/s (1 in/s), 150 ± 4,5 mV peak
Vibration Sensor
0415 39V-2A 1218
Characteristics: For 25,4 mm/s (1 in/s), 150 ± 4,5 mV peak
Vibration Sensor
0415 39V-3A 1218
Characteristics: For 25,4 mm/s (1 in/s), 150 ± 4,5 mV peak
Vibration Sensor
0415 39V-3B 1218
Characteristics: For 25,4 mm/s (1 in/s), 150 ± 4,5 mV peak
Vibration Sensor
0415 39VS-11 0235 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 3
SIZE DWG NO SH REV
A4 113A7969 4 D

Item Item
Devices Designation
PID TG
Vibration Sensor
0415 39VS-12 0235 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)
Vibration Sensor
0415 39VS-31 1160 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)
Vibration Sensor
0415 39VS-32 1160 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)
Break glass unit accessory compartment
0426 43CP-1 1605
Characteristics: Normal : NO
Break glass unit GT compartment
0426 43CP-2 1605
Characteristics: Normal : NO
Break glass unit accessory compartment
0426 43CP-3 1605
Characteristics: Normal : NO
Break glass unit GT compartment
0426 43CP-4 1605
Characteristics: Normal : NO
Break glass unit load compartment
0426 43CP-5 1605
Characteristics: Normal : NO
0424 43FUOP 1103 valve VP-1 and VP-2 push button
0442 43TW-1/PB 1105 Off-Line Water Wash Push button
0442 43TW-2/PB 1105 Turbine Water Wash Push button
Thermostatic fire detector Accessory compartment
0426 45FA-1A 1104
Characteristics: Normal : NO Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector Accessory compartment
0426 45FA-1B 1104
Characteristics: Normal : NO Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector Accessory compartment
0426 45FA-2A 1104
Characteristics: Normal : NO Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector Accessory compartment
0426 45FA-2B 1104
Characteristics: Normal : NO Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector Turbine compartment
0426 45FT-1A 1103
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Turbine compartment
0426 45FT-1B 1103
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Turbine compartment
0426 45FT-2A 1154
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Turbine compartment
0426 45FT-2B 1154
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Turbine compartment
0426 45FT-3A 1154
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Turbine compartment
0426 45FT-3B 1154
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Load compartment
0426 45FT-8A 1160
Characteristics: Normal : NO Closed : 385 ± 14°C (725 ± 25°F)
Thermostatic fire detector Load compartment
0426 45FT-8B 1160
Characteristics: Normal : NO Closed : 385 ± 14°C (725 ± 25°F)
Thermostatic fire detector Load compartment
0426 45FT-9A 1160
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Load compartment
0426 45FT-9B 1160
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Gas detector Gas Auxiliary compartment
0474 45HA-1 1153
Characteristics: Range : 0 – 20% LEL
Gas detector in Auxiliary Compartment
0474 45HA-2 1153
Characteristics: Range : 0 – 20% LEL
Gas detector Gas in Auxiliary Compartment.
0474 45HA-3 1153
Characteristics: Range : 0 – 20% LEL
Gas detector Gas in Gas cabinet Module.
0474 45HA-4 1605
Characteristics: Range : 0 – 20% LEL
Gas detector Gas in Gas cabinet Module.
0474 45HA-5 1605
Characteristics: Range : 0 – 20% LEL
Gas detector Gas in Gas cabinet Module.
0474 45HA-6 1605
Characteristics: Range : 0 – 20% LEL
Gas detector Turbine Compartment
0474 45HT-1 1154
Characteristics: Range : 0 – 20% LEL

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 4
SIZE DWG NO SH REV
A4 113A7969 5 D

Item Item
Devices Designation
PID TG
Gas detector Turbine Compartment
0474 45HT-2 1154
Characteristics: Range : 0 – 20% LEL
Gas detector Turbine Compartment
0474 45HT-3 1154
Characteristics: Range : 0 – 20% LEL
Gas detector Turbine Compartment ventilation duct
0474 45HT-4 1605
Characteristics: Range : 0 – 20% LEL
Gas detector Turbine Compartment ventilation duct
0474 45HT-5 1605
Characteristics: Range : 0 – 20% LEL
Gas detector Turbine Compartment ventilation duct
0474 45HT-6 1605
Characteristics: Range : 0 – 20% LEL
Emergency Stop Button accessory compartment
0426 5E-1 1104
Characteristics: Normal : NC
Emergency Stop Button accessory compartment
0426 5E-2 1104
Characteristics: Normal : NC
Pressure switch of the air circuit
0494 63AF-31 E021 Characteristics: Normal : NC
Settings : opening : 3 ± 0.25 bar (43.5 ± 4 PSI)
GT compressed air inlet filter low pressure switch
Characteristics: Normal : NC
0471 63CA-1 A040
Settings: Increase closed at : 6 bars ± 0,5 bar
Decrease opened at : 5,5 bars ± 0,5 bar
GT inlet air system differential pressure switch
0471 63CS-2A A040 Characteristics: Normal : NC
Settings: Increase open at : 23 mbar ± 0,5 mbar
GT inlet air system differential pressure switch
0471 63CS-2B A040 Characteristics: Normal : NC
Settings: Increase open at : 23 mbar ± 0,5 mbar
Liquid fuel pressure upstream of stop valve
Characteristics: Normal: NO
0424 63FL-2 0926
Settings: DEC opened = 35 ± 1 psig
INC closed = 40 ± 2 psig
Hydraulic filter differential Pressure Alarm
Characteristics: Normal : NC
0434 63HF-1 0926
Settings: Inc open at 4,13 ± 0,2 bar (60 ± 3 psi)
Dec close at 2,75 ± 1,03 bar (40 ± 15 psi)
Low hydraulic supply press. Aux hydraulic Pump start
Characteristics: Normal : NO
0434 63HQ-1 0926
Settings: Inc closed at 100 ± 3,1 bar (1450 ± 45 psi )
Dec open at 93 ± 1,7 bar (1350 ± 25 psi)
Fuel filter differential pressure alarm
0424 63LF-3 0992 Characteristics: NORMAL: NC
Settings: INC opened = 15 ± 1 psi
Pressure switch on VA13-1 & VA13-2 intervalves space.
Characteristics: Normal: NC
0477 63PG-1 0918
Settings: Increase open at 3,10 ± 0,13 bar (45 ± 2 psi)
For information, decrease close at 2,75 ± 0,13 bar (45 ± 2 psi)
Pressure switch on liquid fuel purge air.
Characteristics: Normal: NO
0477 63PL-21 918T
Settings: Increase close at 7 ± 0,25 bar (101 ± 4 psi)
For information decrease open at 5,6 ± 0,25 bar (81 ± 4 psi).
Low Lube Oil Pressure Alarm
Characteristics: Normal : NO
0416 63QA-2 0926
Settings: Dec. Open : 2,8 ± 0,07 bar (40,6 ± 1 psig)
(For Information : Inc. Close : 3,1 ± 0,14 bar ( 45 ± 2 psig))
Differential pressure switch Main Lube Oil Filter
Characteristics: Normal : NC
0416 63QQ-1 0926
Settings: Inc. Open : 1,03 ± 0,068 bar (15 ± 0,1 psig)
(For Information : Dec. Close : 0,9 ± 0,2 bar (13 ± 3 psig))
Mist eliminator lube oil filter differential pressure switch
0416 63QQ-10 A098 Characteristics: Normal : NC
Settings: Inc. open : 80 ± 3 mbar
Torque converter filter differential pressure
0416 63QQ-8 0916 Characteristics: Normal : NC
Settings: Inc. Open : 1,5 ± 0,2 bar (21,75 ± 3 psi)

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 5
SIZE DWG NO SH REV
A4 113A7969 6 D

Item Item
Devices Designation
PID TG
Low Lube Oil Pressure generator side
Characteristics: Normal : NO
0416 63QT-2A ALT.
Settings: Dec. Open : 0,55 ± 0,021 bar (8 ± 0,3 psig)
(For Information : Inc. Close :0,62 ± 0,035 bar (9 ± 0,5 psig))
Turbine shell and exhaust frame blower discharge pressure switch
0417 63TK-1 A053 Characteristics: Normal : NO
Settings: Closed above 15 ± 3 inch H2O
Turbine shell and exhaust frame blower discharge pressure switch
0417 63TK-2 A053 Characteristics: Normal : NO
Settings: Closed above 15 ± 3 inch H2O
Gas cabinet ventilation pressure switch
0436 63VL 1605 Characteristics: Normal : NO
Settings: increase close at 25 ± 3 mm CE
Water injection Pump inlet pressure switch Characteristics: Normal: NO
0462 63WN-1 A035
Settings: Dec Open at 10.00 ± 0.20 PSI
Water injection Pump outlet pressure switch
0462 63WN-2 A035 Characteristics: Normal: NO
Settings: Dec Open at 580.000 ± 10.000 PSI
Water injection filter differential pressure switch
0462 63WN-3 A035 Characteristics: Normal: NC.
Settings : Inc Open factory set at 17 ± 2 PSID.
0424 65FP 0533 Liquid fuel pump (by pass valve) servo valve
0422 65GC-1 0541 Gas control valve servo valve
Level switch in the tank 501BA
0494 71FA-31 E021 Characteristics: Normal : NO
Settings: Opening on low level
Level switch in the aux tank
0494 71FA-32 E021 Characteristics: Normal : NO
Settings: Opening on low level
High level lube oil tank
0416 71QH-1 1038 Characteristics: Normal : NC
Settings: Incr. Open on high level. See lube oil schematic MLItem 416 for setting
Low level lube oil tank
0416 71QL-1 1038 Characteristics: Normal : NO
Settings: Decr. Open on low level. See lube oil schematic MLItem 416 for setting
Flow divider magnetic pickup
0424 77FD-1 0992
Settings: Gap : 0.23 ± 0.025 mm (0.009 inch ± 0.001 inch)
Flow divider magnetic pickup
0424 77FD-2 0992
Settings: Gap : 0.23 ± 0.025 mm (0.009 inch ± 0.001 inch)
Flow divider magnetic pickup
0424 77FD-3 0992
Settings: Gap : 0.23 ± 0.025 mm (0.009 inch ± 0.001 inch)
Speed Sensor
0415 77HT-1 0546
Settings: Air-gap : 1,27 ± 0,127 mm (0,05 ± 0,005 inch)
Speed Sensor
0415 77HT-2 0546
Settings: Air-gap : 1,27 ± 0,127 mm (0,05 ± 0,005 inch)
Speed Sensor
0415 77HT-3 0546
Settings: Air-gap : 1,27 ± 0,127 mm (0,05 ± 0,005 inch)
Speed Sensor
0415 77NH-1 0546
Settings: Air-gap : 1,27 ± 0,127 mm (0,05 ± 0,005 inch)
Speed Sensor
0415 77NH-2 0546
Settings: Air-gap : 1,27 ± 0,127 mm (0,05 ± 0,005 inch)
Speed Sensor
0415 77NH-3 0546
Settings: Air-gap : 1,27 ± 0,127 mm (0,05 ± 0,005 inch)
Vibration Sensor
0415 77RP-11 0235 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)
Atomizing air booster motor
0425 88AB-1 1047
Characteristics: 15 kW | 2925 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor – Acoustic enclosure
0436 88BT-1 1605
Characteristics: 15 kW | 1460 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor – Acoustic enclosure
0436 88BT-2 1605
Characteristics: 15 kW | 1460 rpm | 400 VAC | 50 Hz | 3 PH |
Electrical Cranking Motor
0421 88CR-1 0603
Characteristics: 1000 kW | 2973 rpm | 6,6 kV | 50 Hz | 3 PH |

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 6
SIZE DWG NO SH REV
A4 113A7969 7 D

Item Item
Devices Designation
PID TG
Electric motor of the PFA-30 pump
0494 88FA-30 E021
Characteristics: 0,46 kW | 1500 rpm | 230 VAC | 50 Hz | 1 PH |
Electric motor of the PFA-31 pump
0494 88FA-31 E021
Characteristics: 0,37 kW | 1500 rpm | 400 VAC | 50 Hz | 3 PH |
Electric motor of the PFA-32 pump
0494 88FA-32 E021
Characteristics: 0,37 kW | 1500 rpm | 400 VAC | 50 Hz | 3 PH |
Flow divider starting motor
0424 88FM 0613
Characteristics: 0,37 kW | 1400 rpm | 400 VAC | 50 Hz | 3 PH |
(auxiliary) hydraulic supply pump motor
0434 88HQ-1 0628
Characteristics: 15 kW | 2925 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor – Air Atomization Water Injection compartment
0436 88JS-1 1605
Characteristics: 0.5 kW | 1400 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor – Air Atomization Water Injection compartment
0436 88JS-2 1605
Characteristics: 0.5 kW | 1400 rpm | 400 VAC | 50 Hz | 3 PH |
Auxiliary Lube oil pump motor
0416 88QA-1 1006
Characteristics: 90 kW | 3000 rpm | 400 | 50 Hz | 3 PH |
Emergency Lube Oil Pump Motor
0416 88QE-1 1007
Characteristics: 7,5 kW | 1750 rpm | 125 V | - Hz | DC |
Lube Oil Mist Eliminator Motor
0416 88QV-1 A098
Characteristics: 7,5 kW | 3000 rpm | 400 VAC | 50 Hz | 3 PH |
Turning Gear Electrical Motor
0421 88TG-1 0538 Characteristics: 30 kW | 725 rpm | 400 VAC | 50 Hz | 3 PH |
Settings: Not applicable
Turbine Exhaust Frame Cooling Fan Vent Motor
0417 88TK-1 1233
Characteristics: 45 kW | 2900 rpm | 400 VAC | 50 Hz | 3 PH |
Turbine Exhaust Frame Cooling Fan Vent Motor
0417 88TK-2 1233
Characteristics: 45 kW | 2900 rpm | 400 VAC | 50 Hz | 3 PH |
Torque adjuster drive motor
0421 88TM-1 0605
Characteristics: 1,5 kW | 3000 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor Load compartment.
0436 88VG-1 1605
Characteristics: 7,5 kW | 1450 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor Load compartment.
0436 88VG-2 1605
Characteristics: 7,5 kW | 1450 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor – Gas compartment
0436 88VL-1 1605
Characteristics: 0.37 kW | - rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor – Gas compartment
0436 88VL-2 1605
Characteristics: 0.37 kW | - rpm | 400 VAC | 50 Hz | 3 PH |
Water injection system Pump motor
0462 88WN-1 A035
Characteristics: 55 kW | 3000 rpm | 400 VAC | 50 Hz | 3 PH |
0422 90SR-1 0541 Speed ratio/stop valve servo valve
0469 90TV-1 0540 Inlet Guide Vane Servovalve
Electro-pneumatic converter for VC4-1 control valve
0462 90WN-1 A035 Settings : 4,00 ± 0,20 mA for 0,00 ± 0,010 BAR (0 mm)
20,00 ± 0,20 mA = 2,40 ± 0,010 BAR (19 mm)
Ignition exciter
0415 95SG-13 1213
Characteristics : 150 VA | 115 VAC (or 230 VAC) | 15 kV | 150 VA
Ignition exciter
0415 95SG-14 1213
Characteristics : 150 VA | 115 VAC (or 230 VAC) | 15 kV | 150 VA
0415 95SP-13 1214 Spark plug for combustion chamber 13
0415 95SP-14 1214 Spark plug for combustion chamber 14
Atomizing air main compressor differential pressure transmitter
0425 96AD-1 0926 Settings: 4 ± 0.05 mA for 0 bar
20 ± 0.05 mA for 6 bar (87 psi)
Pressure transmitter
0492 96AP-1A 0559 Settings: 4 mA ± 0,02 mA for 0,800 bar (23,6 in of Hg)
20 mA ± 0,10 mA for 1,200 bar (35,4 in of Hg)
Pressure transmitter
0492 96AP-1B 0559 Settings: 4 mA ± 0,02 mA for 0,800 bar (23,6 in of Hg)
20 mA ± 0,10 mA for 1,200 bar (35,4 in of Hg)
Pressure transmitter
0492 96AP-1C 0559 Settings: 4 mA ± 0,02 mA for 0,800 bar (23,6 in of Hg)
20 mA ± 0,10 mA for 1,200 bar (35,4 in of Hg)
Compressor Discharge Pressure Transmitter
0417 96CD-1A 0557 Settings: 4 ± 0.05 for 0 bar ( 0 psi )
20 ± 0.05 for 21 bar ( 304.5 psi )

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 7
SIZE DWG NO SH REV
A4 113A7969 8 D

Item Item
Devices Designation
PID TG
Compressor Discharge Pressure Transmitter
0417 96CD-1B 0557 Settings: 4 ± 0.05 for 0 bar ( 0 psi )
20 ± 0.05 for 21 bar ( 304.5 psi )
Compressor Discharge Pressure Transmitter
0417 96CD-1C 0557 Settings: 4 ± 0.05 for 0 bar ( 0 psi )
20 ± 0.05 for 21 bar ( 304.5 psi )
Pressure transmitter
0492 96CS-1 0559 Settings: 4 mA ± 0,02 mA for 0,0000 bar
20 mA ± 0,10 mA for 0,0274 bar (11 in of H2O)
GT air inlet system differential pressure transmitter
0471 96CS-3 A040 Settings: 4 ± 0,05 mA for 0 mbar
20 ± 0,05 mA for 24,9 mbar
Exhaust Pressure Transmitter
0422 96FG-1 0557 Settings: 4 ± 0,05 mA for 0 bar ( 0 psi)
20 ± 0,1 mA for 35 bar (510 psi)
Fuel Gas inter-valve Pressure Transmitter
0422 96FG-2A 0557 Settings: 0 ± 0,05V for 0 bar (0 psi)
5 ± 0,05 V for 34,5 bar (500 psi)
Fuel Gas inter-valve Pressure Transmitter
0422 96FG-2B 0557 Settings: 0 ± 0,05V for 0 bar (0 psi)
5 ± 0,05 V for 34,5 bar (500 psi)
Fuel Gas inter-valve Pressure Transmitter
0422 96FG-2C 0557 Settings: 0 ± 0,05V for 0 bar (0 psi)
5 ± 0,05 V for 34,5 bar (500 psi)
Mass flow transmitter
0422 96FM-1 0639 Settings: Factory Calibrated : 4 ± 0,05 mA for 0 kg/s ( 0 lms/s)
20 ± 0,1 mA for 10 kg/s ( 22 lbm/s)
Gas control valve LVDT
0422 96GC-1,2 0509
Settings: 0,7 ± 0,01 VAC for 0 mm
Lube Oil header Pressure transducer
0416 96QA-2 0926 Settings: 4 ± 0,05 mA for 0 bar (0 psi)
20 ± 0,1mA for 7 bar (101,5 psi)
Low Lube Oil Pressure transmitter generator
0416 96QT-2B ALT. Settings : 4 ± 0,05 mA for 0 bar (0 psig)
20 ± 0,1 mA for 1,72 bar (25 psig)
Dew point and temperature transmitter
Settings: Outlet 1 : 4 ± 0,05 mA for –50°C
0471 96RH A040 20 ± 0,05 mA for +50°C
Outlet 2 : 4 ± 0,05 mA for 0% RH
20 ± 0,05 mA for 100 % RH
Stop Ratio Fuel Gas (VSR-1) LVDT
0422 96SR-1,2 0507
Settings: 0.7 ± 0,01 VAC for 0 mm
GT air filter clogging differential pressure transmitter
0471 96TF-1 A040 Settings: 4 ± 0,05 mA for 0 mbar
20 ± 0,05 mA for 25 mbar
Torque Converter IGV Position Transmitter
0421 96TM-1 0605 Settings: 4 ± 0,05 for 0 tr
20 ± 0,05 for 31 tr
Inlet Guide Valve LVDT
0469 96TV-1 0548
Settings: 0,7 ± 0,01 VAC for 34°
Inlet Guide Vane Actuator LVDT (Linear variable displacement transmitter)
0469 96TV-2 0548
Settings: 0,7 ± 0,01 VAC for 34°
Vibration Sensor
0415 96VC-11 0235 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)
Vibration Sensor
0415 96VC-12 0235 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)
Flow transmitter of the Water injection flow meter FM1-1
0462 96WF-4 A035 Settings : 4 ± 0,05 mA for 0 m3/h
20 ± 0,1 mA for 15 m3/h
Atomizing air precooler air discharge thermocouple.
0425 AAT-1A 0637
Characteristics: Type K
Atomizing air precooler air discharge thermocouple.
0425 AAT-2A 0637
Characteristics: Type K

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 8
SIZE DWG NO SH REV
A4 113A7969 9 D

Item Item
Devices Designation
PID TG
Control oil hydraulic accumulator
0434 AH1-1 0502 Characteristics: Capacity : 2,5 gal | Nitrogen
Settings: 51,7 ± 1 bar (750 ± 15 psi)
Control oil hydraulic accumulator
0434 AH1-2 0502 Characteristics: Capacity : 2,5 gal | Nitrogen
Settings: 51,7 ± 1 bar (750 ± 15 psi)
Water injection compartment inside temperature measurement
0436 AT-JC-1 1605 Characteristics: type K
Settings: +15°C / +8°C
Load compartment temperature
0436 AT-LC-1 0637
Characteristics: PT100 | 100 ohms at 0°C | 0,385 ohm / °C |
Turbine compartment temperature
0436 AT-TC-1 0637
Characteristics: PT100 | 100 ohms at 0°C | 0,385 ohm / °C |
Thermocouple temperature Bearing bushing n°1
0415 BT-J1-1A,1B 0235
Characteristics: Type K
Thermocouple temperature Bearing bushing n°1
0415 BT-J1-2A,2B 0235
Characteristics: Type K
Thermocouple temperature Bearing bushing n°2
0415 BT-J2-1A,1B 0235
Characteristics: Type K
Thermocouple temperature Bearing bushing n°2
0415 BT-J2-2A,2B 0235
Characteristics: Type K
Thermocouple temperature Bearing bushing n°3
0415 BT-J3-1A,1B 0235
Characteristics: Type K
Thermocouple temperature Bearing bushing n°3
0415 BT-J3-2A,2B 0235
Characteristics: Type K
Thermocouple temperature pad n°2 of thrust bearing n°1
0415 BT-TA1-2A,2B 0235
Characteristics: Type K
Thermocouple temperature pad n°5 of thrust bearing n°1
0415 BT-TA1-5A,5B 0235
Characteristics: Type K
Thermocouple temperature pad n°8 of thrust bearing n°1
0415 BT-TA1-8A,8B 0235
Characteristics: Type K
Thermocouple temperature pad n°2 of counter thrust bearing n°1
0415 BT-TI1-2A,2B 0235
Characteristics: Type K
Thermocouple temperature pad n°5 of counter thrust bearing n°1
0415 BT-TI1-5A,5B 0235
Characteristics: Type K
Thermocouple temperature pad n°9 of counter thrust bearing n°1
0415 BT-TI1-9A,9B 0235
Characteristics: Type K
Main atomizing air compressor.
0425 CA1 0607
Characteristics: Centrifugal | 2,7kg/s | 6500 rpm
Booster Atomizing Air Compressor.
0425 CA2 1047
Characteristics: Volumetric | 510m3/h | 6200 rpm
Thermocouple temperature air outlet of compressor
0415 CT-DA-1 0637
Characteristics: Type K
Thermocouple temperature air outlet of compressor
0415 CT-DA-2 0637
Characteristics: Type K
Thermocouple temperature air inlet of compressor
0415 CT-IF-1 0637
Characteristics: Type K
Thermocouple temperature air inlet of compressor
0415 CT-IF-2 0637
Characteristics: Type K
Cranking Motor Stator Ph1 Temp Sensor 1
0421 ET-CRS-11/R 0603
Characteristics: Pt100-3 wires | 100 ohms at 0 °C | 0,385 ohm / °C | Range –50 to +260 °C
Cranking Motor Stator Ph1Temp Sensor 2
0421 ET-CRS-12/R 0603
Characteristics: Pt100-3 wires | 100 ohms at 0 °C | 0,385 ohm / °C | Range –50 to +260 °C
Cranking Motor Stator Ph2 Temp Sensor 1
0421 ET-CRS-21/R 0603
Characteristics: Pt100-3 wires | 100 ohms at 0 °C | 0,385 ohm / °C | Range –50 to +260 °C
Cranking Motor Stator Ph2 Temp Sensor 2
0421 ET-CRS-22/R 0603
Characteristics: Pt100-3 wires | 100 ohms at 0 °C | 0,385 ohm / °C | Range –50 to +260 °C
Cranking Motor Stator Ph3 Temp Sensor 1
0421 ET-CRS-31/R 0603
Characteristics: Pt100-3 wires | 100 ohms at 0 °C | 0,385 ohm / °C | Range –50 to +260 °C
Cranking Motor Stator Ph3 Temp Sensor 2
0421 ET-CRS-32/R 0603
Characteristics: Pt100-3 wires | 100 ohms at 0 °C | 0,385 ohm / °C | Range –50 to +260 °C
0477 FA3-1 918T Liquid fuel purge air filter.
0425 FA4-1 0983 Atomizing air actuation air filter.
0477 FA6-1 1015 Filter on actuation air of fuel gas purge air valves.
0462 FA8-2 A035 Strainer on control air supply circuit

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 9
SIZE DWG NO SH REV
A4 113A7969 10 D

Item Item
Devices Designation
PID TG
Flow divider
0424 FD1-1 0613
Characteristics: Volumetric | 883 l/min | 1650 Hz | 1650 tr/min
0424 FF2-1 1014 HP fuel filter
0424 FF2-2 1014 HP fuel filter
0494 FF31-1 E021 Filter before the pumps
0434 FH2-1 1051 Hydraulic supply filter
0434 FH2-2 1051 Hydraulic supply filter
0424 FH3 0992 Hydraulic supply filter-liquid fuel servo
0469 FH6-1 0548 IGV controller assembly hydraulic oil supply filter
0422 FH7-1 0911 Servo hydraulic supply filter of Gas fuel control & stop valve
0422 FH8-1 0991 Gas Fuel Control Valve (VGC-1) Servo Hydraulic Oil Supply Filte
Water injection flow meter
0462 FM1-1 A035
Characteristics: Flow range : 4,4 to 176 GPM
Resistive temperature device connected to 96FM-1
0422 FT-MG-1/R 0639
Characteristics: Type : PT100
0462 FW1-1 A035 High Pressure Water injection main filter
0462 FW1-2 A035 Water injection system low pressure strainer
0421 HM1 0605 Torque Converter and Reversing Gear
Actuator assembly, Inlet Guide Vane System
0469 HM3-1 0548
Settings: Actuator operation limits : 32° to 86°
0425 HX1-1 1003 Atomizing air precooler.
Lube Oil Thermocouple #1 Bearing Drain
0416 LT-B1D-1A,1B 0637
Characteristics: Type K
Lube Oil Thermocouple #2 Bearing Drain
0416 LT-B2D-1A,1B 0637
Characteristics: Type K
Lube Oil Thermocouple #3 Bearing Drain
0416 LT-B3D-1A,1B 0637
Characteristics: Type K
Lube Oil Thermocouple #1 Bearing Drain
0416 LT-BT1D-1A,1B 0637
Characteristics: Type K
ALT./ Lube Oil generator #1 Bearing Drain Resistance Temperature Detector
0416 LT-G1D-1
GEN. Characteristics : PT100 | 100 Ohms à 0°C |
ALT./ Lube Oil generator #2 Bearing Drain Resistance Temperature Detector
0416 LT-G2D-1
GEN. Characteristics : PT100 | 100 Ohms à 0°C |
Lube oil tank resistance temperature detector
0416 LT-OT-1A 0938
Characteristics: Type K
Lube oil tank resistance temperature detector
0416 LT-OT-2A 0938
Characteristics: Type K
Lube oil temperature turbine header thermocouple
0416 LT-TH-1A,1B 0637
Characteristics: Type K
Lube oil temperature turbine header thermocouple
0416 LT-TH-2A,2B 0637
Characteristics: Type K
Lube oil temperature turbine header thermocouple
0416 LT-TH-3A,3B 0637
Characteristics: Type K
0422 MG1 0512 Gas fuel nozzle
0422 MG2-1 0639 Gas fuel metering tube-orifice
Main fuel Pump
0424 PF1 0611
Characteristics: Volumetric | 870.5 l/min | 68.9 bar | 1550 tr/min
Unloading pump
0494 PFA-30 E021
Characteristics: Volumetric type | 25 l/min |
Dosing pump
0494 PFA-31 E021
Characteristics: Volumetric and piston pump | 25 l/h (6.60 Gal/h) | 10 bar (145 psi) | 1500 tr/min
Dosing pump
0494 PFA-32 E021
Characteristics: Volumetric and piston pump | 25 l/h (6.60 Gal/h) | 10 bar (145 psi) | 1500 tr/min
Main hydraulic supply pump
0434 PH1 0627 Characteristics: Volumetric – positive displacement 65 l/min (17,1 GPM) |105 bar (1500 psi) | 1422 tr/min (1422
RPM)
Auxiliary hydraulic supply pump
0434 PH2 0628
Characteristics: Volumetric 45,4 l/min (12 GPM) | 105 Bar (1500 psi) |1450 tr/min (1450 RPM)
Breather valve of 501BA tank
0494 PSV-31 E021 Characteristics: Normal : NC
Settings: Overpressure : 0.15 bar; Vacuum : 0.01 bar
0462 PW1-1 A035 Pump unit
Light warning accessory compartment
0426 SLI-1 1104
Characteristics: 230 UPS – 50 Hz

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 10
SIZE DWG NO SH REV
A4 113A7969 11 D

Item Item
Devices Designation
PID TG
Fire alarm : flashing light unit
0426 SLI-1A 1605
Characteristics: 24VDC
Fire alarm : flashing light unit
0426 SLI-1B 1605
Characteristics: 24VDC
Fire alarm : horn and flashing light unit load
0426 SLI-1C 1605
Characteristics: 24VDC
Light warning accessory compartment
0426 SLI-2 1104
Characteristics: 230 UPS – 50 Hz
Fire alarm : horn and flashing light unit load
0426 SLI-2C 1605
Characteristics: 24VDC
Fire alarm : horn and flashing light unit load
0426 SLI-3C 1605
Characteristics: 24VDC
Thermocouple temperature exhaust tunnel
0415 TT-IB-1 0637
Characteristics: Type K
Thermocouple temperature external position after first wheel
0415 TT-WS1A0-1 0637
Characteristics: Type K
Thermocouple temperature external position after first wheel
0415 TT-WS1A0-2 0637
Characteristics: Type K
Thermocouple temperature internal position before first wheel
0415 TT-WS1FI-1 0637
Characteristics: Type K
Thermocouple temperature internal position before first wheel
0415 TT-WS1FI-2 0637
Characteristics: Type K
Thermocouple temperature external position after second wheel
0415 TT-WS2AO-1 0637
Characteristics: Type K
Thermocouple temperature external position after second wheel
0415 TT-WS2AO-2 0637
Characteristics: Type K
Thermocouple temperature external position before second wheel
0415 TT-WS2FO-1 0637
Characteristics: Type K
Thermocouple temperature external position before second wheel
0415 TT-WS2FO-2 0637
Characteristics: Type K
Thermocouple temperature external position after third wheel
0415 TT-WS3AO-1 0637
Characteristics: Type K
Thermocouple temperature external position after third wheel
0415 TT-WS3AO-2 0637
Characteristics: Type K
Thermocouple temperature external position before third wheel
0415 TT-WS3FO-1 0637
Characteristics: Type K
Thermocouple temperature external position before third wheel
0415 TT-WS3FO-2 0637
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-1 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-10 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-11 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-12 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-13 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-14 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-15 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-16 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-17 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-18 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-19 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-2 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-20 0623
Characteristics: Type K

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 11
SIZE DWG NO SH REV
A4 113A7969 12 D

Item Item
Devices Designation
PID TG
Thermocouple temperature GT exhaust
0415 TT-XD-21 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-22 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-23 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-24 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-3 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-4 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-5 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-6 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-7 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-8 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-9 0623
Characteristics: Type K
Gas fuel purge air valve.
0477 VA13-1 0918
Characteristics: Normal: NC
Gas fuel purge air valve.
0477 VA13-2 0918
Characteristics: Normal: NC
False start drain valve-combustion wrapper
0424 VA17-1 1026
Settings: Normal : NO
False start drain valve-exhaust frame
0424 VA17-2 1026
Settings: Normal : NO
False start drain valve-exhaust plenum
0424 VA17-5 1026
Characteristics: Normal : NO
Atomizing air compressor by pass valve.
0425 VA18-1 1070
Characteristics: Normal: NC
Liquide fuel purge air valve.
0477 VA19-1 918T
Characteristics: Normal : C to L opened ; U closed
Compressor Bleed valve 11th stage
0417 VA2-1 1022
Characteristics: Normal : NO
Compressor Bleed valve 11th stage
0417 VA2-2 1022
Characteristics: Normal : NO
Booster atomizing air compressor isolating valve.
0425 VA22-1 0922
Characteristics: Normal: NO
Compressor Bleed valve 11th stage
0417 VA2-3 1022
Characteristics: Normal : NO
Compressor Bleed valve 11th stage
0417 VA2-4 1022
Characteristics: Normal : NO
Pneumatic valve
0494 VA99-31 E021
Characteristics: Normal : NO
Pneumatic valve
0494 VA99-32 E021
Characteristics: Normal : NC
Pneumatic valve
0494 VA99-33 E021
Characteristics: Normal : NO
0434 VAB1 0947 Hydraulic system air bleed valve (main)
0434 VAB2 0947 Hydraulic system air bleed valve (aux.)
By pass control valve
0424 VC3 0516 Characteristics: Normal : NO
Stroke : 1,125 in
0462 VC4-1 A035 Water injection flow control valve
Liquid fuel nozzle check valve
0424 VCK1-1T14 0961 Characteristics: Normal: NC
Cracking press : 8,27 ± 0,34 Bar (120 ± 5 psig)
Liquid fuel nozzle purge air check valve.
0477 VCK2-1T14 918T Characteristics: Normal: NC
Cracking pressure 0.34 ± 0.07 bar (4.93 ± 1 psi).
0434 VCK3-1 0947 Hydraulic pump check valve for main pump

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 12
SIZE DWG NO SH REV
A4 113A7969 13 D

Item Item
Devices Designation
PID TG
0434 VCK3-2 0947 Hydraulic pump check valve for auxiliary pump
Turbine Shell and Exhaust Frame Blower Check Valve
0417 VCK7-1 1233
Characteristics: Normal : NC
Turbine Shell and Exhaust Frame Blower Check Valve
0417 VCK7-2 1233
Characteristics: Normal : NC
Gas control valve
0422 VGC-1 0509 Characteristics: Normal : NC
stroke maxi : 44,5 ± 0,5 mm
0469 VH3-1 0540 Trip relay, hydraulic, IGV
VSR security discharge valve
0422 VH5-1 0507
Characteristics: Normal : NO
VGC trip valve
0422 VH5-2 0509
Characteristics: Normal : NO
0434 VM4 1052 Hydraulic filter transfer valve
0424 VP-1 0961 Fuel liquid purge multiport valve
0424 VP-2 0961 Fuel liquid purge multiport valve
Bearing header pressure regulator valve
0416 VPR2-1 1023 Characteristics: Normal : NC
Settings: Set point : 1,72 + 0,13 /-0 bar (25 + 2 /-0 psi)
Filter regulator
0494 VPR30-31 E021 Characteristics: Normal : NO
Settings: 4 bar (58 psi)
Hydraulic supply pump (PH1) compensator
0434 VPR3-1 0627
Settings: Setting : 1500 +20/-0 psig
Filter pressure regulator on actuation air of gas fuel purge air valve.
0477 VPR44-1 0918
Settings: 2,3 +0/-0,2 bar (33,35 +0/-2,9 psi)
Filter pressure regulator on actuation air of gas fuel purge air valve.
0477 VPR44-2 0918
Settings: 2,3 +0/-0,2 bar (33,35 +0/-2,9 psi)
Filter pressure regulator on actuation air of liquid fuel purge air valve.
0477 VPR54-1 0918
Settings: 3,27 +1,7/-0 bar (47,5 +2,7/-0 psi)
Water injection VC4-1 transfer valve air pressure regulation
0462 VPR62-1 A035 Characteristics: Normal: NC
Settings: Setting: 35.00 ± 5.00 PSI
Water injection stop valve pressure regulator
0462 VPR62-11 A035 Characteristics: Normal : NC
Settings: 6,9 ± 0.340 bar (100 ± 4,9 psi)
Instrumentation air filter pressure regulator on VA22-1 actuation.
0425 VPR68-1 0922
Settings: 3,79 ± 0,13 bar (55 ± 2 psi)
Quick exhaust valve
0462 VQE1-1 A035
Characteristics: Normal : NC
Main lube oil pump pressure relief valve
0416 VR1 1016 Characteristics: Normal : NC
Settings: Opening at 6,89 + 0,13/-0 bar (100 + 2/-0 psi)
Main hydraulic supply pump pressure relief valve
0434 VR21 0947
Settings: 1650 ± 20 psi
Auxiliary hydraulic supply pump pressure relief valve
0434 VR22 0947
Settings: Setting : 1650 ± 20 psig
Pressure relief valve on liq. Fuel piping
0424 VR27 0992 Characteristics: Normal: NC
Settings: Setting : 6 ± 0,2 bar (87 ± 2,9 psi)
Main fuel pump pressure relief valve
0424 VR4 0992 Characteristics: Normal : NC
Settings: Setting : 82,7 ± 1,72 bar (1200 ± 25 psi)
PFA-31 Pump relief pressure valve
0494 VR60-31 E021 Characteristics: Normal : NC
Settings: Opening at 12 ± 1 bar (174 ± 14,5 psi)
PFA-32 Pump relief pressure valve
0494 VR60-32 E021 Characteristics: Normal : NC
Settings: Opening at 12 ± 1 bar (174 ± 14,5 psi)
Fuel oil stop valve
0424 VS1 0511
Characteristics: Normal : NC
Water injection stop valve
0462 VS2-1 A035
Characteristics: Normal : NC
Fuel gas stop/speed ratio valve
0422 VSR-1 0507
Characteristics: Normal : NC | stroke maxi : 88,67 mm ( 3,5 in)

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 13
SIZE DWG NO SH REV
A4 113A7969 14 D

Item Item
Devices Designation
PID TG
Bearing header temperature regulator valve
0420 VTR1 1035 Characteristics: Normal: E to B open, C closed.
Settings: Starts to open at Oil T° = 130 ± 3.6 F.
Atomising air precooler air discharge temperature regulator valve
0420 VTR2-1 1027 Characteristics: Normal: B to E open, C closed.
Settings: T° air = 225 ± 3.6 F
Resistance thermometer detector Support legs water temperature
0420 WT-TL-1 0637
Characteristics: Platinum PT100 | 100 Ohm at 32°F | 0,214 Ohm / °F | -58 to 500 °F
Resistance thermometer detector Support legs water temperature
0420 WT-TL-2 0637
Characteristics: Platinum PT100 | 100 Ohm at 32°F | 0,214 Ohm / °F | -58 to 500 °F

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 14

You might also like