GENERATOR

MPPT SHORE POWER


COLOR CONTROL CONNECTION
MAIN DC DISTRIBUTION victron energy
BLUE POWER

victron energy
BLUE POWER
AC Input Inverting AC Loads
victron energy
0W 435W

SmartSolar charge controller


victron energy
-

75%
+
PV-Charger
victron energy

950W
MPPT 100 | 50 BLUE POWER

340W
DC Power
25.6V 13.2A -155W
MEGA
xxxA Load+ SHORE POWER

! i IP43
ISOLATION TRANSFORMER OR
Battery 12/24V 50A GALVANIC ISOLATOR SHOULD BE
OFF MEGA V+

Absorbtion
xxxA Load+ GND
PV 100Vmax 50A INSERTED HERE IF NEEDED,
INCLUDING NECESSARY

Float
Bulk
BREAKERS.

MAINSWITCH-1 MEGA color control BATTERY PV


xxxA Load+
ON + - - +

MEGA
xxxA Load+ PV ARRAY

VE.Direct-1

VE.Direct-2

VE.Direct
VE.Bus

ETHERNET
VRM
MEGA WORLD
PRE-MAIN-FUSE xxxA Load+
1A FUSE
name name

ANL

THERMAL CIRCUIT BREAKER


0 OFF 0 OFF 0 OFF 0 OFF

60 AMPERE
600A

285060F
A
B
T
PV BREAKERS

D
A
L
100mA FUSE
SE
T MPPT+ ISOLATORS
RE

OFF

MultiPlus Batt +

MEGA
ON 400A

MAINSWITCH-2
MultiPlus Batt +
AC POWER SOURCE MAIN INCOMING
CHANGE OVER SWITCH AC BREAKERS
MULTIPLUS 5KW/24V/230V AC INVERTER/CHARGER
BMV-712 SMART
BMV-712 SMART
BATTERY MONITOR
victron energy
BLUE POWER

MAIN V

AGM BATTERIES VE.Direct


SETUP SELECT

0
Shore Gen
victron energy name name

BLUE POWER
0 OFF 0 OFF 0 OFF 0 OFF
www.victronenergy.com

SUPPLIED UTP CABLE victron energy


AGM 12-230 BLUE POWER

charger inverter
AGM Super Cycle Battery mains on
I on
inverter on

CENTRAL NEGATIVE.BusBAR
AC in 1 AC out 1
bulk overload
AC out 2 O off
absorption low battery
charger only
float temperature

.battery charger .sinewave inverter .transfer switch

MultiPlus Battery
.powerassist .parallel
connectable
.three phase
connectable

VOLT
24 |5000 |120

AMP
VA
AC transfer capacity: 100A | Inverter 230V

CE

victron energy CCGX-


BLUE POWER
Load-
Load-
AGM 12-230 Load-
AGM Super Cycle Battery AC DISTRIBUTION
Load- FROM MULTIPLUS

Load-
1 N 1 N
Load-
victron energy
BLUE POWER name name name name name name name name
ADxxxxx xxA/I n0.03A ADxxxxx xxA/I n0.03A

MPPT- Bx
T
test regularly Bx
T
test regularly

0 0 OFF 0 OFF 0 OFF 0 0 OFF 0 OFF 0 OFF

MultiPlus Batt-
AGM 12-230
earth fault indicator earth fault indicator

TEMP SENSE MCB/RCD MCB/RCD


AGM Super Cycle Battery MultiPlus Batt-
Conn-A+P AC IN 2 N 2 N

MultiPlus Case GR Conn-D+P AC OUT-2


Conn-C+P AC OUT-1 MULTIPLUS MULTIPLUS
SHUNT IS MOUNTED OUTPUT-1 OUTPUT-2
Conn-B VE.Bus
victron energy DIRECT ON BUSBAR
BLUE POWER
Conn-E Temp
+B2
+B1
Conn-G Batt+
No Break load-1
Conn-G Batt+ No Break load-2
AGM 12-230 No Break load-3
AGM Super Cycle Battery Conn-F Batt-
Switched load-1
Conn-F Batt- Switched load-2
Drawing BJE-252A
Conn-L Case ground Switched load-3

Recommended AC Out-2 cable/breaker size MultiPlus Recommended AC Out-1 cable/breaker size MultiPlus Recommended DC cable/fuse size MultiPlus Recommended AC IN WARNING
cable/breaker size MultiPlus
AC Out-2 only is available when power is With Power assist the MultiPlus can add 0-5 m cable length: 4 x 50SQmm 230 VOLT IS EXTREMELY HAZARDOUS
present on AC IN. During battery operation 5KW to the output load when needed. 5-10 m cable length: 4 x 95SQmm AC IN must be protected by a circuit DO NOT TOUCH ANY LIFE WIRED
it will be disconnected. AC Out-2 supports Together with the adjustable 100A input Cable length stands for the distance between the breaker rated at 100A max or less. This PARTS OF THE INSTALLATION !!!
up to 50A. An Earth leakage device with this all adds up to the max sum of input battery connections and the MultiPlus connections depends heavily on the size of the WHEN IN DOUBT, ALWAYS CONSULT
breaker or a combination MCB/RCD must and output current of 100+21=121A. An !!! Recommendations are without other loads in the connected power source.The input current YOUR VICTRON DEALER !!!
be installed on the output. Cable size must Earth leakage device with breaker or a system and these also should be taken into must be adjusted to fit the size of the
be adjusted accordingly. combination MCB/RCD must be installed account for proper main battery, main fuse & main connected power source.
on the output. Cable size must be adjusted switch cables !!! The breaker and cable size for AC IN
accordingly. Fuse size should be 1 x 400A. should be adjusted accordingly.