You are on page 1of 1

MPPT PV BREAKERS/ISOLATORS PV ARRAY

COLOR CONTROL
MAIN DC DISTRIBUTION victron energy
BLUE POWER

victron energy
BLUE POWER
AC Input Inverting AC Loads
victron energy
0W 435W

SmartSolar charge controller


-

75%
+
PV-Charger
victron energy

950W
MPPT 100 | 50
340W
DC Power name name
25.6V 13.2A -155W
MEGA
xxxA Load 1+
0 OFF 0 OFF 0 OFF 0 OFF
! i IP43

Battery 12/24V 50A


OFF MEGA V+

Absorbtion
xxxA Load 2+ GND
PV 100Vmax 50A

Float
Bulk
MAINSWITCH-1 MEGA color control BATTERY PV
xxxA Load 3+
ON + - - +

MEGA
xxxA Load 4+

VE-direct-1

VE-direct-2

VE BUS

ETHERNET

VE-direct
GENERATOR
VRM
MEGA WORLD
PRE-MAIN-FUSE xxxA Load 5+
1A FUSE

ANL

THERMAL CIRCUIT BREAKER


40 AMPERE
600A

285040F
A
B
T

D
A
L
100mA FUSE
SET MPPT+
RE

OFF

MEGA
200A Quattro Batt +

ON

MAINSWITCH-2 MEGA
200A Quattro Batt +
MAIN INCOMING
AC BREAKERS
QUATTRO 5KW/24V/230V AC INVERTER/CHARGER TOWARDS
BMV-712 SMART QUATTRO
BMV-712 SMART
BATTERY MONITOR
victron energy
BLUE POWER

MAIN V

AGM BATTERIES VE-direct


SETUP SELECT
victron energy
BLUE POWER

victron energy name name

BLUE POWER
0 OFF 0 OFF 0 OFF 0 OFF

SUPPLIED UTP CABLE


www.victronenergy.com
SHORE POWER
AGM 12-230 victron energy
BLUE POWER
CONNECTION
AGM Super Cycle Battery charger inverter ISOLATION TRANSFORMER OR
AC in 1 AC out 1
mains on
I on
inverter on GALVANIC ISOLATOR SHOULD BE
bulk overload
AC in 2 AC out 2
absorption
O off
low battery
INSERTED HERE IF NEEDED,
CENTRAL NEGATIVE BUSBAR float
charger only
temperature INCLUDING NECESSARY
BREAKERS.
.battery charger .sinewave inverter .transfer switch

Quattro Battery
.powerassist .parallel
connectable
.three phase
connectable

VOLT
24 |5000 |120

AMP
AC transfer capacity: 2x100A | Inverter 230V

VA
victron energy CE

BLUE POWER CCGX- VE.Bus-1 VE.Bus-2

Spare-
Load 1- BATTERY

AGM 12-230 Load 2-


IN
1
IN
1
OUT
1
OUT
1-2
OUT
2
_ _
BATTERY IN
2
IN
2

AGM Super Cycle Battery L N L N L


BATTERY
+ +
L N

AC DISTRIBUTION

NEUTRAL

NEUTRAL
LINE

LINE

LINE

LINE
BATTERY
Load 3-

NEUTRAL
GND TRICKLE
V-SENSE T-SENSE AUX1 AUX2 RELAY CHARGE K1 K2

GROUND

GROUND
AC IN-1 AC OUT-1 AC OUT-2
+ - + - + - + - + - S1 S2

ON

1
S1
2
S2
+

TRICKLE
CHARGE
NC NO COM NC NO COM
AC IN-2 GROUND
FROM QUATTRO
Load 4-

Load 5-
victron energy 1 N 1 N

BLUE POWER

MPPT- name
ADxxxxx xxA/I n0.03A
name name name name
ADxxxxx xxA/I n0.03A
name name name

Bx
T Bx
T
test regularly test regularly

0 0 OFF 0 OFF 0 OFF 0 0 OFF 0 OFF 0 OFF


Quattro Batt-
AGM 12-230 TEMP SENSE
earth fault indicator earth fault indicator

AGM Super Cycle Battery Quattro Batt- Conn-J+O AC IN-2 MCB/RCD MCB/RCD
Conn-A+P AC IN-1
Quattro Case GR Conn-D+P AC OUT-2 2 N 2 N

Conn-C+P AC OUT-1
SHUNT IS MOUNTED Conn-B VE Bus QUATTRO QUATTRO
DIRECT ON BUSBAR OUTPUT-1 OUTPUT-2
victron energy Conn-E Temp
BLUE POWER
+B1
Conn-G Batt+
No Break load-1
Conn-G Batt+ No Break load-2
AGM 12-230 No Break load-3
AGM Super Cycle Battery Conn-F Batt-
Switched load-1
Conn-F Batt- Switched load-2
Drawing BJE-251A
Conn-L Case ground Switched load-3

Recommended AC Out-2 cable/breaker size Quattro Recommended AC Out-1 cable/breaker size Quattro Recommended DC cable/fuse size Quattro Recommended AC IN-1 & AC IN-2 WARNING
cable/breaker size Quattro
AC Out-2 only is available when power is With Power assist the Quattro can add 5KW 0-5 m cable length: 4 x 50SQmm 230 VOLT IS EXTREMELY HAZARDOUS
present on AC IN-1 or AC IN-2. During to the output load when needed. Together 5-10 m cable length: 4 x 95SQmm AC IN-1 & AC IN-2 both must be protected DO NOT TOUCH ANY LIVE WIRED
battery operation it will be disconnected. with the adjustable 100A input this all adds Cable length stands for the distance between the by a circuit breaker rated at 100A max or PARTS OF THE INSTALLATION !!!
AC Out-2 supports up to 50A and is up to the max sum of input and output battery connections and the Quattro connections !!! less. This depends heavily on the size of WHEN IN DOUBT, ALWAYS CONSULT
adjustable. An Earth leakage with breaker current of 100+21=121A. An Earth leakage Recommendations are without other loads in the the connected power source.The input YOUR VICTRON DEALER !!!
or a combination MCB/RCD must be with breaker or a combination MCB/RCD system and these also should be taken into currents must be adjusted to fit the size of
installed on the output. Cable size must be must be installed on the output. Cable size account for proper main battery, main fuse & main the connected power source. The breaker
adjusted accordingly. must be adjusted accordingly. switch cables !!! and cable size for both AC IN-1 & AC IN-2
Fuse size should be 1 x 400A or 2 x 200A should be adjusted accordingly.