You are on page 1of 2

PENDING ITEMS AND ITEMS NOT FOUND ON RIG ST#1

1. INSTALLED REJECTED FIRE FIGHTING PUMP FROM ST#3, FIXING SAME “ON GOING”.
2. CHANGED 13 5/8'' ANNULAR BOP ELEMENT WITH NEW ONE, TESTED SAME W/ 3500
PSI BUT HAD LEAK FROM CLOSING CHAMBER TO RESERVOIR TANK, DISASSEMBLED
ANNULAR BOP AND FOUND INTERNAL O-RING SEAL BETWEEN ITS PISTON AND
CLOSING CHAMBER DAMAGED AND WAITING OTHER NEW SEALS F/ CAIRO "ON
GOING".
3. EMERGENCY ENGINE NEEDS TOP OVERHAULLING, OPEN.
4. NEED CERTIFICATES OF UT WALL THICKNESS FOR (STANDPIPE LINES, STAND
PIPEMANIFOLD), OPEN.
5. NEED NEW FILTRATION UNIT COMPATIBLE WITH POTABLE WATER TANK
"IMPORTANT FOR HYGIENE", OPEN.
6. FIX AIR LEAK IN CLUTCH OF DRAWWORK SYSTEM, OPEN.
7. BOP TEST PUMP WITHOUT TEST CHART RECORDER & HAD NO CERTIFICATE, OPEN.
8. TOP DRIVE M/UP TRQ NOT MATCHED WITH MANUAL RIG TONG TRQ, OPEN.
9. INSTALLING LAST LINE OF DIVERTER VENT LINES & EXTEND VENT LINE FROM MGS TO
FLARE PIT, OPEN.
10.FIX AIR LEAK IN CASING STABBING BOARD & REMOTE CONTROL PANEL AT RIG
FLOOR., OPEN
11.WHILE TESTING MP#3 WITH 3500 PSI, HAD LEAK FROM WASH PIPE & ALSO HAD
PRESS DROP 200 PSI IN 20 MIN, CHANGING WASH PIPE AND CHECKING MUD
PUMP#3, ON GOING.
12.CAT-IV CERTIFICATES FOR (ROTARY TABLE),
13.CAT WAIK, AIR RECIEVER TANK ON RIG FLOOR) W/OUT LIFTING LUGS.
14.ST-01 CSG LINKS & 13 3/8” CSG SLIPS & SPIDERS ON ST-03.
15.SHORTAGE IN SHAKER & MUD CLEANER SCREENS.

1
16.SHORTAGE IN 5" DP (HAVE ONLY 190 JTS).
17.NO 13 3/8" CUP TESTER & 9 5/8’’ CUP TESTER AVAILABLE ON RIG SITE
18.NON SPARKING TOOLS TO BE AVAILABLE (HAMMER- WRENCHES)
19.FORKLIFT WITH CLAMP ATTACHEMENT TO SECURE PIPES
20.NO OIL SPILL KIT AVAILABLE ON RIG SITE
21.NO AVAILABLE STANDARD STRETCHER IN CASE OF EMERGENCY AT HEIGHT
22.NO TRI-POD AVAILABLE ON RIG SITE.
23.NEED DROPPED OBJECTSURVEY BY 3RD PARTY CO
24.NEED THREE PORTABLE RADIOS
25.STANDARD CHECMICAL BIG BAG LIFTER WITH CRANE
26.FORK LIFT & CHEMICALS BARREL LIFTER
27.GENERAL MAINTENANCE FOR DAMAGED BAD CONDITION CARAVANS IN FLY CAMP,
GENERAL BATHROOM & CHAIRS FOR MEETING ROOM
28.AIR CONDITIONER FOR DRILLER CABIN
29.NEED STANDARD LIFE LINES TO BE INSTALLED OVER CARAVANS
30.WORKSHOP, GENERATOR HOUSE, D.TANK MISSING ANTI-FALLING SYSTEM.

ST#1 RIG SUPERVISOR

KAREEM HASSAN