NDT REPORT

Report No : UT.181 Inpection Date : Januay 11, 2018


Order No : 1011MTR NDT Method : Ultrasonic Test
On behalf of : PT. MATRA Material : SS
Test part : PUMP SHAFT Surface condition : As machined
Location : PT. MATRA Bandung Qty : 3 pcs
Test Procedure : ASTM-114 Inspector/Level : Dadang H./II
TEST PARAMETERS
Ultrasonic Unit Search Unit Ref. Std.
SIUI Freq. (Mhz) : 2.5 V1
ctc 9005 Dia. (mm) : 20 V2
Angle (°) : 0

TEST RESULT

Ultrasonic Test was carried out on the Pump Shaft to determine the presence of relevant indications such as
cracks, lamination, macro inclusions or others discontinuities.
The test was initiated from radial and axial direction (diameter and longitudinal of shaft)

NO DESCRIPTION QTY RESULT DISPOSITION

1 Top Pump Shaft 1 ea No Relevant Indication Accepted


2 Intermediate Pump Shaft 1 ea No Relevant Indication Accepted
3 Pump Shaft 1 ea see below Accepted

pos-2 pos-3
LEVEL III/ENG.-COMMENT

pos-1

UT Illustration of Lower Pump Shaft

Pos-1 Full ultrasonic reflection-max amplitudo


Pos-2 Full ultrasonic reflection-max amplitudo
Pos-3 utrasonic attenuation-reducing amplitudo 10%

LEVEL III/ENG.-COMMENT

Ultrasonic attenuation due to some cases, its can be light hardfacing, grain direction /form changes
Changing material accoustic impedance or ultrasonic scaterring etc.
Need to further investigation to determine life time.
But the ultrasonic test does not indicate any relevant UT Indication, it is Accepted.

Inspected by Reviewed by Approved by

Dadang Hermawan Aripin Tanjung Customer


January 11, 2018 January 11, 2018