Plot No 234,11th Main 3rd Cross ,3rd PhasePeenya Industrial Area Bangalore-560 058

MAGNETIC PARTICLE EXAMINATION REPORT


REPORT No : D212 / 06.08.2019

QTY 05 Nos. W.O.NO:- D212

Customer : M/s L & T Valves Limited

P ONO :
Item Description : BONNET FORGING

Drawing No : LT346165F

Stage of test: : Proof machined


Material Specification: :ASTM A 105
Requirement : MPI
Equipment Used :Magna Flux Yoke Type
Type of Current :DC/AC
Type of Magnetization :Non Fluorescent 7C Black Powder - Kerosene Base.
Pole Spacing :4"-6"
Magnetisation Technique :Yoke
Methode of Exam :Continuous &Wet Method
Ref STD Specification :ASTM A275 & ASME B16.34 Appendix 2 & NDE 002 Rev. 8
Area of Inspection : 100 % covered

TEST RESULT
Under the above conditions of testing, No Relevant indication observed. Accepted

TESTED BY

(SHIVASHANKER.H.S)
ASNT Level II UT,MPT,LPT