Unit Control Panel

Auto operation display Cooling operation display Dry operation display

Fan operation display Up and down airflow display

Left and right airflow display Sleep operation display Turbo operation display

On timer operation display Off timer operation display Lock operation display

Room Temp/Set Temp Set Timer display Specification


Testing information display Fan speed display

Operation buttons
Auto: Automatically choose the operation mode by sensing the difference between the actual
ambient room temperature and the set temperature on the remote controller.
The fan speed is automatically controlled.
INDOOR
Cool: Enables you to enjoy the cooling effect at your
preferred setting temperature (Temperature range:17oC~30oC). Model No Unit 42KFJ024718 42KFJ036518 42KFJ042518 42KFJ055518
Dry: Enables you to set the desired temperature at low fan speed which provides you with
the dehumidifying surroundings (Temperature range:17oC~30oC). In Dry mode, Performance rating Btu/h 24000 33000 42000 55000
6 you can not select Fan speed and Sleep mode. (For cooling models only)
(Temperature setting range:17oC~30oC) Input W 164 300 300 300
Fan only: Permits fan operation without cooling. In this case, however,
Indoor fan motor
TEST Speed(turbo/hi/med/lo) r/min - /575/540/440 -/600/550/480 -/600/550/480 630/615/580/530
R U N N IN G the setting temperature is not displayed and you can not adjust the set temperature.
L OCK ADJUST button function: Indoor air flow m /h
3
1100 1700 1700 2300
1. Temperature adjust: Press the and to adjust the temperature in a range of
FA N A U X IL IA RY 7 17o C~30o C. Indoor noise level (hi/low) db(A) 47/42 52/48 52/48 58/53
O N /O F F M O D E A DJUST S P E E D F U N C T IO N 2. Timer adjust: Adjust the timer on/off time under the Timer setting mode(0~24hrs).
Dimension(WXDXH) mm 500x290x1700 540x410x1825 540x410x1825 610x390x1925
3. Auxiliary function selection: Select the desired auxiliary function by pressing
and button.
Indoor unit Packing(WXDXH) mm 1805x615x415 1935x655x555 1935x655x555 2045x745x545
4. Under the Test Running mode, press to check information about T1, T2, T3,
T4(For Cooling models only), P4 , P5, P7, P9(For Cooling models only), Net/Gross weight kg 37/49 54/68 56/70 67/80
P10, P11 and P12 . If no protection function occurs, the code is shifted.
5. Under malfunction condition: Press the and to check the malfunction code E1, Controller Remote Control
1 2 3 4 5 E2, E3, E4(For cooling modles only), E5, E10, E13 or E14 It displays HS while defrosting.
6. Under any of the above circumstance, if keep pressing the and without releasing, Operating Temperature Cooling °C ≥17 ≥17 ≥17 ≥17
the setting changes 4 times per second.

OUTDOOR

FAN SPEED button: This button is used to select the desired fan speed. Each time you push the button, a fan speed is shifted in the direction Model No 38KFJ024718 38KFJ036518 38KFJ042518 38KFJ055518
of the arrow:
Power supply Ph-v-Hz 1Ph,220-240v~50Hz 3Ph,380v ~50Hz 3Ph,380v ~50Hz 3Ph,380v ~50Hz
NOTE: You cannot select fan speed under AUTO and DRY mode. The fan motor operates at pre-set AUTO speed under AUTO mode and at LOW speed Input W 168 162 290 148
under DRY mode. Fan speed displays: The display is separated into 3 zones. Outdoor fan motor
When setting the speed, the corresponding zone will illuminate Speed r/min 900 860 830 800
3 3
Dimension(WxDxH) mm 845x320x700 900x315x860 990x345x965 900x350x1170
2 2
Select LOW fan speed and the first zone will illuminate; 1 1 Outdoor unit Packing(WxDxH) mm 965x395x755 1043x395x915 1120x435x1100 1032x443x1307
Select AUTO fan speed and zones 1~2 will illuminate;
Select HIGH fan speed and zones 1~3 will illuminate. Net/Gross weight kg 48/51 62/66 88/93 103/108
Once selected, after 2 seconds the zones will illuminate gradually based on the speed selected.
For example, HIGH fan speed will show the display illuminating quickly from zone to zone. Refrigerant Type R22 R22 R22 R22
Note: when the indoor fan is stopped, nothing will display.
Type/Quantity Charge Volume kg 1.4 1.9 1.65 3.9
5 AUXILIARY FUNCTION button: Use this button to select or cancel the auxiliary feature. Press this button, Max. pipe length m 20 20 20 20
then press the ADJUST and button to select the desired feature. Each time the button is pressed, the mode is Refrigerant Piping
shifted in the direction of the arrow: button: Max. difference in level m 10 10 10 10
If press button: If press
Once the desired feature is established, press the AUXILIARTY FUNCTION button again to register.
Above design & specifications are subject to change without prior notice.
NOTE: The above illustration is for explanation purpose only. The features are different depending on models

For more details, please contact our Carrier India sales office:
Factory & Corporate Office: Carrier Airconditioning & Refrigeration Ltd, Kherki Daula Post, Narsingpur, Gurgaon 122004,
Tel: 0124-4825500. Sales Offices:– Delhi/NCR: 0124-4707311/4707333 Ghaziabad: 0120-4183260 Lucknow:
0522-2202346 /2230598 Chandigarh: 0172-5007548/ 5007550 Jaipur: 0141-5113444/5113999 Indore: 0731-4070378
W e a r e c o n f i d e n t t o s t a n d & d e l i v e r.

Septtember 2014
Mumbai: 022-61700700 Ahmedabad: 079-40267777 Pune: 020-67045100 Kolkata: 033-40201300 Chennai:
044-42222888 Bangalore: 080-43442000 Hyderabad: 040-41100222 Cochin: 0484-4029001/0

CIN: U74999HR1992FLC036104/ Website: www.carrierindia.com/ E-mail: bssindia@carrier.utc.com

The Manufacturer reserves the right to change any product specifications without prior notice
©All Rights Reserved Carrier
Salient Easy-cleaned panel Self-diagnosis &
Auto-protection
Anti-Rust Cabinet Auto Restart
Function
Independent
Dehumidification
Fresh Air LCD Dynamic Display

Features The Air Inlet Grill & Filter is easy to clean, easy to
remove and can be washed with cold water.
Gives immediate information on the error occurred in
the unit and in the Auto mode the machine
automatically chooses the operation mode by sensing
The Anti-rust coating on the cabinet makes cleaning
of the air outlet and louver very easy
Power Failure during operation will stop the unit
completely. For the unit with this feature, when
the power restores, the unit starts automatically with
It helps in controlling the high humidity levels and
it also improves the indoor air quality significantly
The air conditioner have a pump in the indoor unit,
the pump sucks the fresh air from outside, and the indoor
polluted airflow out of the room via the air presure.
LCD Dynamic Display Eye catching digital LCD
panel presents modern home appliance feature.

difference between actual ambient room temperature all previous settings preserved by the memory function.
and the set temperature on remote controller.
The fan speed is automatically controlled.