You are on page 1of 1

Issued 17 Mar 2004.

Translated 10 May 2004, page 1 of 1


LX1-X_self_test_routine.doc, author : Steffen Krüger
Spezielle Studiotechnik GmbH
Tel: +49 (0)2154 4840 0
Fax: +49 (0)2154 4840 350
Email: s.krueger@behringer.de

Self-Test Routine X-
Procedure for service technicians 27.05.2004
1. Software version
• To view software version press „MODULE“ Switch test
during power on. The text „BEHRINGER X-V- 1. STORE
AMP V1.xx” will be scrolled across the
display. 2. NOISE G.

• Restore factory presets by pressing keys 3. COMPR.


„STORE“ and „TAP“ together during power 4. DOWN
on. After the reset, display shows “0”.
5. MODUL
2. Function check of operational
6. UP
elements in self-test mode
7. DELAY
• Press and hold keys „NOISEG“, „MODUL“,
„REVERB“ during power on. 8. REVERB

• LED test pattern A -> press “TAP” 9. - not used -

• LED test pattern B -> press “TAP” 10. TAP

• Display shows „P“ for switch contact test. 11. PEDAL switch
Press each switch, including footswitches and
pedal switch.
Note: after switch test set pedal to fully “open” Encoder test
• Display shows „E“ for encoder function test. 1. Gain
Turn both encoders. 2. FX / AMPS
• Pedal calibration. Display shows „PU“. Push
pedal fully down (closed) to end of travel.
Display shows „PL“. Bring pedal back to fully Switch combinations:
open. Again, display shows „PU“. Press pedal (press and hold together during power on)
switch.
Factory test (System 1) NoiseG+Modul+Reverb
• Display shows „d2, d3“ Internal DSP Tests
carried out. Audio test Delay + Compressor
Revision test Modul
• Display shows „A1“: Digital Zero -> TAP to
continue LED Test Compr+Modul+Delay
• Display shows „A2“: Audio Bypass -> TAP to Pedal Calibration Delay+Reverb
continue
• Display shows „A3“: 42 dB Gain -> TAP to
continue
• Display shows „A4“: 0 dB Sine ca. 1kHz ->
TAP to continue (For software V1.26 onwards,
pedal calibration at this point)
• Press „TAP“ und „REVERB“ together, display
shows „CL“ -> Reset.