Partial Volume For Horizontal Cylindrical Tank (Determination of Maximum Operating Liquid Level) Partial Volume For Cylinder
Partial Volume For Horizontal Cylindrical Tank (Determination of Maximum Operating Liquid Level) Partial Volume For Cylinder
From Pressure Vessel Handbook, by Eugene F.Megyesy, 11th Edition. Pg. 419
So, total length of fixed ullage dip tube = Di - partial height + Flange height + Shell thk.+ Gasket
= 1530-1195+215+13+3
= 566 mm