You are on page 1of 1

Design Computation for Cofferdam

TOP OF SHEET FILE


Properties of Type II Sheet Pile ( L = 12m.)

S = 874cm³/m (12m. ) = 10.488x10-3m3


S.Y = 295MPa
IX = 152.9 cm²/m
wt. = 48kg/m.
CRANEWAY
H2O

w =1000kg/m³

w = 400mm.
WATER LEVEL P1 h = 400mm.
SAND t = 10.5mm.
RIVER BED

s= 1600kg/m³
TOP OF PILE CAP
P2
P3
BOT. OF PILE CAP
0
Moment center
P1 = Water Pressure
DESIGN COMPUTATIONS P2 = Soil Pressure Rectangular
P3 = Soil Pressure Triangular
let h = 5 m.
w = 1000kg/m³
= 9,810 N/m³ ( Mass density of Water )

P1 = 9,810 N/m³ x 5.0m. ( 5x0.4)


= 98,100 N / 2
= 49,050 N

P2 = 9,810 x 4.10 ( 4.10 x 0.4 )


= 65,962 N

P3 = 1,600 kg x 9.81x 4.10 ( 4.1x0.4 )


= 105,539.9N / 2
= 52,769.95 N

ƩM0 = P1h1 + P2h2 + P3H3

h1 = 4.1 + 5 3 = 5.767m.
h2 = 4.12 = 2.05m.
h3 = 4.1 =1.367m.
3

ƩM0 = 49.050 (5.767) + 65,962.44(2.05) + 52,770(1.367)


= 490,229.97 N.m

ƒ = MS

= x 490,230 N.m 10.488 x10-³m³

ƒ = 46,741,988 N/m2 < 295MPa Ok Safe

Safety Factor = 6.31


1 OF 4

You might also like