Professional Documents
Culture Documents
PROJECT CODE-DB-MRB-AR-____
000
PERSPECTIVE VIEW 01 PERSPECTIVE VIEW 02
DATE:__________
FOR CONSTRUCTIONMAR 2021
BIM VERIFIED REVIEWED BY NOTE:
BIM DC · THIS DETAIL SHALL BE REVIEWED TOGETHER
PERSPECTIVE VIEW 03 AUTHOR LA
WITH ARCHITECTURAL, STRUCTURAL, BIM,
MECHANICAL, ELECTRICAL & PLUMBING
· SITE TO COORDINATE WITH THE DESIGN
IDD TEAM FOR ANY DISCREPANCY PRIOR TO
BENNETH
IMPLEMENTATION.
GE
PROJECT TITLE / LOCATION ARCHITECT ENGINEER OWNER'S REPRESENTATIVE OWNER SHEET CONTENTS NO. DATE REVIEWED BY REVISIONS SHEET NO.
These drawings shall be read in
conjunction with structural, - GATE DETAILS (GARBAGE ROOM AREA) - - -
ME-PIC SHERWIN 3/22/21
IVORYWOOD RESIDENCES mechanical, electrical, plumbing/ DMCI PDI - - - - IVW
FILE_PATH
PROJECT CODE-DB-MRB-AR-____
E
000
R
T
E
T
N
E
C
R
R E L
E T N
A
A
T E C
43 41
N N
42
M E
P
E O
C
L
N
N
R A
E A
C
T
E N
E
M P
O
E
KAMIA (D) LAUAN (C) PILLOW BLOCK UCP 207
12-BAY ( 6+2 ) 12-BAY ( 6+2 ) 6000 35mm
C
143 Units / 160 Slots 143 Units / 176 Slots
300 4100 300 1150 150
L
50mmx100mmx2mm thk
150 50 4000 50 150 1000 150
A
TUBULAR STEEL IN QDE
R
UP
N
FLORES (E) 150 1000 1000 1000 1000 150 950 50 PAINT FINISH (COLORMATCH
A
PALMIRA (B)
6° RAMP
6° RAMP
DN
E
DN
TOILET
(5.50 SQM) COFFEE AREA
GAME AREA
BAR
C
(11.00 SQM)
KITCHEN
(6.00 SQM)
12-BAY ( 6+2 )
SAVEMORE
UP
12-BAY ( 6+2 )
143 Units / 134 Slots
BARREL BOLT (GATE)
UP
LOUNGE AREA
T
IVORYWOOD RESIDENCES
(435.00 SQM)
UP
GATE)
N
7° RAMP
M
UP
O
7° RAMP
E
E
UP
P
GATE HEIGHT
E
25mmx25mmx2mm thk
E
O
M
N
TUBULAR STEEL IN QDE
100 500
T
PAINT FINISH (COLORMATCH
C
PROPOSED UTILITY
E
A
AREA GATE WITH EXISTING ENTRANCE
N
.
R
R.O.W
GATE)
A
M
ADELFA (F) ANAHAW (A)
20.00
L
11-BAY ( 6+1 ) 11-BAY ( 6+1 )
SECOND GATE
131 Units / 62 Slots 131 Units / 62 Slots
50mmx100mmx2mm thk
2250
TUBULAR STEEL IN QDE
2400
03 KEY PLAN
E
L A N A C N E P O
1650
MS-AR-01 SCALE 1:250 MTS (A1) MAIN ENTRANCE
- WITH EXISTING ENTRANCE
N
1:500 MTS(A3) KOREAN ROAD
GATE)
T
41 42 43 25mmx25mmx2mm thk
E
TUBULAR STEEL IN QDE
R
6000 BASE (GATE) PAINT FINISH (COLORMATCH
150
150 1150 300 4100 300 DRIVEWAY FFL WITH EXISTING ENTRANCE
150 1000 150 50 4000 50 150 GATE)
150 150
25mmx25mmx2mm thk FOOT BOLT (GATE)
RC COLUMN, PAINTED FINISH IVORYWOOD UTILITY GATE
(COLOR AND DESIGN MATCH TUBULAR STEEL IN QDE
WITH EXISTING) PAINT FINISH (COLORMATCH 04 REAR ELEVATION
EXISTING WITH EXISTING ENTRANCE MS-AR-01
- SCALE 1:25 MTS (A1)
EXISTING UTILITY AREA GATE) 1:50 MTS(A3)
GARBAGE ROOM EXISTING DRIVEWAY (SAVEMORE)
CONCRETE MOLDINGS, 950 1000
EXISTING FENCE PAINTED FINISH
(IVORYWOOD) (MATCH WITH EXISTING) 100 750 100 100 800 100
50mmx100mmx2mm thk 400 7 EQ DIMENSIONS
TUBULAR STEEL IN QDE 25 350 25
PAINT FINISH (COLORMATCH
WITH EXISTING ENTRANCE
100
100
G1 G2 A A
WL WL GATE)
950 4000 GATE HEIGHT
600
400
600
600
400
600
100 100
1000 1000 1000 1000 B B
100 100
600
50 950 50 4000 50 25mmx25mmx2mm thk
TUBULAR STEEL IN QDE
100
100
EXISTING WALKWAY 1000 4100 A A
PAINT FINISH
TUBULAR STEEL GATE IN (COLORMATCH WITH
QDE PAINT FINISH (VERIFY EXISTING ENTRANCE
APPROVED COLOR) GATE) WALL
SCONCE
2400
IVORYWOOD GARBAGE ROOM
DATE:__________
2250
2250
2250
2250
1050
1050
03 UTILITY GATE PLAN
A B A A B A
1650
MS-AR-01 SCALE 1:25 MTS (A1) 50mmx100mmx2mm thk
-
MAR 2021
1:50 MTS(A3)
TUBULAR STEEL IN QDE
1550
1550
25mmx25mmx2mm thk 41 42 43
TUBULAR STEEL IN QDE PAINT FINISH (COLORMATCH
PAINT FINISH (COLORMATCH 6000 WITH EXISTING ENTRANCE
WITH EXISTING ENTRANCE 150 GATE)
1150 300 4100 300
GATE) RC COLUMN, PAINTED
150 1000 150 50 4000 50 150 FINISH (COLOR AND
50mmx100mmx2mm thk 50 950 150 1000 1000 1000 1000 150 DESIGN MATCH WITH
TUBULAR STEEL IN QDE
50
BASE (GATE)
EXISTING)
150
600
600
PAINT FINISH (COLORMATCH DRIVEWAY FFL
WITH EXISTING ENTRANCE
GATE) G1 G2 WALL SCONCE
100
100
950 4000 A A
150
GATE HEIGHT
100 750 100 100 800 100
FOR CONSTRUCTION
100 500
2250
UTILITY AREA
LEGEND
TOTAL WIDTH FOR 4 PANELS: 4000mm
1650
DRIVEWAY FFL
BIM VERIFIED REVIEWED BY NOTE:
BIM DC · THIS DETAIL SHALL BE REVIEWED TOGETHER
50mmx100mmx2mm TUBULAR STEEL IVORYWOOD UTILITY GATE 25mmx25mmx2mm TUBULAR STEEL AUTHOR LA
WITH ARCHITECTURAL, STRUCTURAL, BIM,
MECHANICAL, ELECTRICAL & PLUMBING
IN QDE PAINT FINISH (COLORMATCH 03 FRONT ELEVATION IN QDE PAINT FINISH (COLORMATCH IDD
· SITE TO COORDINATE WITH THE DESIGN
WITH EXISTING ENTRANCE GATE) MS-AR-01 SCALE 1:25 MTS (A1) WITH EXISTING ENTRANCE GATE) BENNETH
TEAM FOR ANY DISCREPANCY PRIOR TO
- 1:50 MTS(A3) GE IMPLEMENTATION.
PROJECT TITLE / LOCATION ARCHITECT ENGINEER OWNER'S REPRESENTATIVE OWNER SHEET CONTENTS NO. DATE REVIEWED BY REVISIONS SHEET NO.
These drawings shall be read in
conjunction with structural, - GATE DETAILS (GARBAGE ROOM AREA) - - -
ME-PIC SHERWIN
DMCI PDI 3/22/21
IVORYWOOD RESIDENCES mechanical, electrical, plumbing/ - - - - IVW
FILE_PATH
MA. SEVERINA M. SORIANO ENGINEER_NAME DENNIS O. YAP sanitary and fire protection
- - - - EE-PIC PAOLO 22MAR21
SITE DEVELOPMENT engineering drawings. DEVELOPER M-SD-05
The Architect shall be notified of - - - -
any discrepancy found and shall
KOREAN ROAD PTR NO.: 8122904 DATE: 1/8/2020 PTR NO.: - DATE: - CTC NO.: 04368506 DATE: 1/16/2020 DMCI PDI DRAWN BY: SHERWIN CHECKED BY: PAOLO - - -
ACACIA ESTATES,TAGUIG CITY REG NO.: 7654 TIN: 111-026-159 REG NO.: - TIN: - PLACE: MAKATI CITY TIN: 207-521-035
be resolved prior to construction
DATE DRAWN: MAR 2021 DATE CHECKED:MAR 2021 - - - RIC ANA -
-
DRAWING_SOURCE
ENCOM NO: PM-2021-02-09 INSTALLATION OF GATE AT IVORYWOOD GARBAGE AREA REF_DWG_DATE
PROJECT CODE-DB-MRB-AR-____
000
41 42 43
6000 12mm thk FOOTING REBARS
1100 SPACED @ 200mm O.C.
300 1000 300 4100 300 10mm Ø LATERAL TIES SPACED AT 1100
300 800 BOTHWAYS
150 150 150 3@0.05m; 3@ 0.10m ; 5 @ 0.15m 800 300
REST @ 0.20m (BOTHWAYS) 300mm thk RC FOOTING
150 150 150 @1000mm DEPTH
400
400
10mm Ø LATERAL TIES SPACED AT
12mm thk FOOTING REBARS 3@0.05m; 3@ 0.10m ; 5 @ 0.15m
SPACED @ 200mm O.C. REST @ 0.20m (BOTHWAYS)
1100
1100
300
300
BOTHWAYS
300
300
400
400
C1F1 C1F1 C1F2
300
RC COLUMN @ 3000 PSI RC COLUMN @ 3000 PSI
2500
2500
REST @ 0.20m (BOTHWAYS)
DATE:__________
300
MAR 2021
300mm thk RC FOOTING 300mm thk RC FOOTING
@1000mm DEPTH @1000mm DEPTH
02 C1 PLAN
MS-ST-01 SCALE 1:25 MTS (A1)
- 1:50 MTS(A3)
1000
1000
SPACED @ 200mm O.C. SPACED @ 200mm O.C.
BOTHWAYS BOTHWAYS
FOR CONSTRUCTION
300
300
04 C1F1 SECTION 06 C1F2 SECTION
Column and Foundation is Adequate. MS-ST-01
- SCALE 1:25 MTS (A1) MS-ST-01
- SCALE 1:25 MTS (A1)
1:50 MTS(A3) 1:50 MTS(A3)
3.19.21
BIM VERIFIED REVIEWED BY NOTE:
BIM DC · THIS DETAIL SHALL BE REVIEWED TOGETHER
WITH ARCHITECTURAL, STRUCTURAL, BIM,
Marven AUTHOR LA MECHANICAL, ELECTRICAL & PLUMBING
· SITE TO COORDINATE WITH THE DESIGN
IDD TEAM FOR ANY DISCREPANCY PRIOR TO
BENNETH IMPLEMENTATION.
GE
PROJECT TITLE / LOCATION ARCHITECT ENGINEER OWNER'S REPRESENTATIVE OWNER SHEET CONTENTS NO. DATE REVIEWED BY REVISIONS SHEET NO.
These drawings shall be read in
conjunction with structural, - GATE DETAILS (GARBAGE ROOM AREA) - - - ME-PIC SHERWIN 3/22/21
IVORYWOOD RESIDENCES mechanical, electrical, plumbing/ DMCI PDI - - - -
22MAR21` IVW
FILE_PATH