TECHNICAL SPECIFICATION

1.
NEREST
NO
ITEM DISCRIBTION Location DELIVERY QTY.
.
DATE
Communication 1- Tower elevation from 60- 65 m 120 DAY
tower 2- Type of the towers Quadruple, Compliant with
international standards.
3- All Tower accessories from DC lighting and
lightening rod etc..
4- Foundation Design with casting the foundation.
5- It withstands a wind speed of 165 km / h and at
full load 120 km / h and that the movement at Maysan
1 the summit does not exceed 0.5 - 1 degree. Al-Kahla 1
6- The towers must bear the weight of 500 kg. J.P
7- The towers must have a walkway break 360 or
270 degrees around the tower, and the distance
between one walkway break and another is
from 15-20 meters.
8- The towers should be painted with two color
white and red and the type of paint Jotun.

Communication 1- Tower elevation from 70-80 m. 120 DAY


tower 2- Type of the towers Quadruple, Compliant with
international standards.
3- All Tower accessories from DC lighting and
lightening rod etc... .
4- Foundation Design with casting the foundation.
5- It withstands a wind speed of 165 km / h and at
Maysan
full load 120 km / h and that the movement at
Castle
2 the summit does not exceed 0.5 - 1 degree. Saleh
1
6- The towers must bear the weight of 500 kg. BVSI
7- The towers must have a walkway break 360 or
270 degrees around the tower, and the distance
between one walkway break and another is
from 15-20 meters.
8- The towers should be painted with two color
white and red and the type of paint Jotun.