Professional Documents
Culture Documents
ALIAMAG
Converter For Electromagnetic Flowmeter
Model AMC3200DF Series
GENERAL
ALIAMAG The AMC3200DF Series converter features in dual
frequency excitation. The reduced noise and improved signal to noise
ratio make it more idea for slurry measurement in various industries
such as papermaking and chemistry. The unit features multiple display
parameters including flow rate, flow total, diagnostics, programming
and troubleshooting. It's equipped with bluetooth, HART and MODBUS
communication functions.
FEATURES
Dual Frequency Excitation Method
Three line LCD display Flow Rate / Totalizer
Accuracy of +/-0.4% value of reading
Bi-directional flow measurement, current and pulse output
Explosion Proof, Ex d ia [ia] q llC T6
Bluetooth / MODBUS / HART communication
Converter can be rotated at four directions for easy installation
STANDARD SPECIFICATION
Excitation : Dual Frequency Excitation Keypad : 3 Internal keys for programming
Display : 3 Lines LCD with illumination and display control
Line 1 : 9 Digit totalizer for forward flow Data Storage : Operation parameters and totalizer
: 9 Digit totalizer for reverse flow figures are stored by EEPROM for more
: 9 Digit totalizer for difference than 10 years
Line 2 : 5 Digit flowrate / velocity / % / mA / Hz Low Flow Cutoff : 0-9.9%
Line 3 : Parameter / Query / Clr tot / Query LOG Damping : 0-99 Seconds
Alarm, Guidance Density Setting : 0.001-9.999 g/cm3
Totalizer Unit : t, kg, g, lb, Ston, Lton, m3, L, mL, Igal, gal, Self Diagnosis : The following error messages are
Mgal, bbl, ft3, a-ft displayed if failure occurs
Time Unit : sec, min, hour, day -Abnormal sample
Measuring Range : Min. 0-0.15 m/s -Pulse width
: Max. 0-15 m/s -Overanged output
Accuracy : +/-0.4% of reading (Velocity≥1.0 m/s) -Internal error
: +/-0.002 m/s (Velocity: 0.3…1.0 m/s) -Overflow
Repeatability : +/-0.2% of reading -Empty pipe
Current Output : 4-20 mA (Isolated) Cable Entry : Standard: M20 Option: 1/2" NPTF
Load : Max. 500 Protection Class : IP67, Explosion Proof, Ex d ia [ia] q llC T6
Pulse Output : Open collector Ambient Temperature : -25~65 °C
Rating : 3-30 VDC, 50 mA Max. Material : Aluminum Alloy
Pulse Rate : 1)Scaled pulse (mL/Pulse, L/Pulse, Other) Power Supply : 90-260 VAC, 50/60 Hz
: 2)Frequency: 0-5000 Hz : 24 VDC +/-10% (Option)
Pulse Width : 50% of band width Power Consumption : 6-8 W (Dependent on sensor size)
Alarm : High / Low with open collector output Weight : 4.5 kg
Rating : 3-30 VDC, 50 mA Max. Mounting : Bracket on 2" pipe
Communication : Bluetooth (Android) Standard AMF Collocation Type : AMF900, AMF601, AMF500
: RS485 (MODBUS Protocol) Standard Sensor Size : DN50-DN450
: HART signal (Compatible) Optional
DIMENSIONS
190 mm
3
∑ 123. 456 m
120mm
40mm 40mm
>
>
ENT
23 mm
23 mm
WIRING DIAGRAM
I+ I- P+ P- R+ R- L N
90-260 VAC
50/ 60 Hz
X Y A C B
ACCURACY
+1.6
+1.2
+0.8
E +0.4
R
R 0.0
O
R
-0.4
%
-0.8
-1.2
-1.6
1 2 4 6 8 10 12
Velocity (m/s)
300
200
M 150
E
T 100
R
E 60
30
10
AMC3200DF Series
Example: AMC3200DF-AC-CP-EX-HT/PT