WARNING
If critical situations that could lead to user’s death or serious injury is assumed by
mishandling of the product:
-Always take precautions to ensure the overall safety of your system, so that the whole system
remains safe in the event of failure of this product or other external factor.
-Do not use this product in areas with inflammable gas. It could lead to an explosion.
-Exposing this product to excessive heat or open flames could cause damage to the lithium battery
or other electronic parts.
-Battery may explode if mistreated. Do not recharge, disassemble or dispose of fire.
CAUTION
If critical situations that could lead to user’s injury or only property damage is assumed
by mishandling of the product.
-To prevent excessive exothermic heat or smoke generation, use this product at the values less than
the maximum of the characteristics and performance that are assured in these specifications.
-Do not dismantle or remodel the product. It could cause excessive exothermic heat or smoke
generation.
-Do not touch the terminal while turning on electricity. It could lead to an electric shock.
-Use the external devices to function the emergency stop and interlock circuit.
-Connect the wires or connectors securely.
The loose connection could cause excessive exothermic heat or smoke generation.
-Do not allow foreign matters such as liquid, flammable materials, metals to go into the inside of the
product. It could cause excessive exothermic heat or smoke generation.
-Do not undertake construction (such as connection and disconnection) while the power supply is on.
It could lead to an electric shock.
Copyright / Trademarks
-This manual and its contents are copyrighted.
-You may not copy this manual,in whole or part,without written consent of Panasonic Electric Works.,Ltd.
-Windows and Windows NT are registered trademarks of Microsoft Corporation in the
United States and/or other countries.
The setting for logging the integral power (instantaneous value and difference value) hourly is
automatically generated only by checking the station numbes of eco-power meters to be used.
Any other settings cannot be specified with this software.
Use a web browser to specify other settings.
This chapter describes the method to log the amount of power of eco-power meters.
Note) Only Internet Explorer (Ver. 6 or later) can be used for the web browser.
Table of Contents
Before You start
2.2 Preparation.................................................................................................2-3
2.2.1 Logging in DLU .......................................................................................... 2-3
2.2.2 Adjusting the Clock .................................................................................... 2-4
Note:
- This software supports DLU Version 2.4 or later. Note that it cannot be used with Version 2.3 or older.
- The above settings are fixed in this software.
- Although the setting is transferred, the IP address of DLU does not change.
To change the setting, open the setting screen of the DLU unit with the web browser (IE).
- This software does not have a function to read out the set contents after saving them. Therefore, leave
notes such as writing down the set contents separately.
Installation
Execute “dlust_v100.exe” to install the DLU Setting Tool software.
1-2
1.1.1 Starting DLU Setting Tool Software
Double-click "Dst.exe" in the installed foler to start the DLU setting tool software.
The following screen is displayed.
1.1.2 Procedure
1. Check the unit numbers of the devices to be connected to the DLU.
(The default is set to use an eco-power meter.)
Note:
- If the number of selected circuits exceeds the registerable number (250) when clicking the OK button,
an error message will appear, and the dialog cannot be closed.
2. Specify the IP address of the DLU to transfer setting data. (Default: 192.168.1.5)
Once the transfer successfully completes, a message “Transfer has been completed” is displayed.
Note:
- Data cannot be transferred when DLU is in RUN mode. Change the mode to STOP mode to transfer
data.
- The clock data in a PC is transferred to the DLU at the same time of setting.
- When transferring the setting, the DLU setting data (dataDstKW.wdl) is generaged in the folder where
this setting tool software has been installed.
- If settings exist in the DLU, note that the settings other than the IP address are all cleared and replaced
with a new setting data.
1-3
1.1.3 Example of Setting
This example shows the setting with the DLU setting tool software on the following system.
[Procedure]
1. Check the station numbers to be used (1 to 3).
Note) If the number of selected circuits exceeds the registerable number (250) when clicking the OK
button, an error message will appear, and the dialog cannot be closed.
2. Specify the IP address of the DLU to transfer setting data, and click “Transfer Settings” button.
1-4
Chapter 2
Setting Method Using Web Browser
2.1 Purposes
- Records the integral power consumption of eco-power meters as the difference value
- Creates one logging file per day. (24 records in one file)
System chart
CSV files
2-2
2.2 Preparation
- Connect the DLU and a PC with an Ethernet cable.
- Set the IP address of the PC to “192.168.1.*”. (except 192.168.1.5)
- Confirm that the switch of the DLU is at the “STOP” position and the “MODE” LED is flashing.
2. As the following screen is displayed, input the user name and password.
2-3
2.2.2 Adjusting the Clock
- As for the clock in the DLU, indefinite data has been set at the factory.
Set the correct time and date before using the DLU.
2-4
2.3 Setting
Main setting items for storing data of eco-power meters
2-5
2.3.2 Setting Triggers (Every One Hour)
(2) Set the cycle for logging data of eco-power meters and the timing of updating the files.
2. Select “Fixed Cycle” for the trigger type, and select “1 hour” for the cycle. Then click “Apply”.
2. Select “The Appointed Time” for the trigger type, and select “0:0:5 every day” for the cycle.
Then click “Apply”.
2-6
2.3.4 Setting Logging Files
(3) Set the file name, trigger to be used for logging interval/file update, number of records and
number of generations.
2. Set “File name”, “Logging Trigger”, “No. of Records” and “No. of Generations”. Then click
“Apply”.
It is not necessary
to set these items.
1. Select the file No. 1 of “Device Registration to a Logging File”, and click “Go”.
2. Set the items such as “Target”, “Logging Type” and “Data Format”. Then click “Apply”.
2-7
2.3.6 Saving the Setting Data in DLU
The specified contents will be effective by recording them in the DLU.
2. Clicking “Save Settign Data to DLU” displays the confirmation message. Click “OK”.
2-8
2.4 Operation
After the completion of setting, change the DLU to the run mode, and confirm if it communicates
with the eco-power meter correctly.
2-9
2.4.1 Changing DLU to Run Mode
(1) Change the DLU to the run mode, and start logging data.
3. If the DLU enters the run mode and the LEDs on the DLU are as below, the DLU communicates
properly.
- If the number of registered points is few, the LEDs almost light up.
- If any setting such as communication condition is incorrect, the ERROR
LED lights up.
[Supplementary note]
When clicking "Update to latest information”, the monitoring value will be updated.
2-10
2.4.3 Checking the Logging File
(3) Check if the file is actually generated in the DLU.
2. Click the file number to check. (See the sample of result in 1.3.4)
[Supplementary note]
- Files that do not reach the specified number of records are “(-----CURRENT-----)”.
- A file can be downloaded by right-clicking on it and selecting “Save Target As”.
2-11