3.

Non-System Based Design


Descriptions & ITAAC AP1000 Design Control Document

3.6 Reactor Coolant Pressure Boundary Leak Detection

Design Description

The reactor coolant pressure boundary leakage detection monitoring provides a means of detecting and
quantifying the reactor coolant leakage. To detect unidentified leakage inside containment, the following
diverse methods are provided to quantify and assist in locating the leakage:

• Containment Sump Level


• Reactor Coolant System Inventory Balance
• Containment Atmosphere Radiation

Leakage detection monitoring is accomplished using instrumentation and other components of several
systems.

1. The diverse leak detection methods provide the nonsafety-related function of detecting small leaks
when RCS leakage indicates possible reactor coolant pressure boundary degradation.

Inspection, Tests, Analyses, and Acceptance Criteria

Table 3.6-1 specifies the inspections, tests, analyses, and associated acceptance criteria for the leak
detection equipment.

Tier 1 Material 3.6-1 Revision 19


3. Non-System Based Design
Descriptions & ITAAC AP1000 Design Control Document

Table 3.6-1
Inspections, Tests, Analyses, and Acceptance Criteria

Design Commitment Inspections, Tests, Analyses Acceptance Criteria

1. The diverse leak detection See Tier 1 Material sections: See Tier 1 Material sections:
methods provide the nonsafety-
i) See Tier 1 Material, i) See Tier 1 Material,
related function of detecting small
Table 2.3.10-4, Item 7a for the Table 2.3.10-4, Item 7a for the
leaks when RCS leakage indicates
sump level measuring instruments sump level measuring instruments
possible reactor coolant pressure
WLS-034 and WLS-035. WLS-034 and WLS-035.
boundary degradation.
ii) See Tier 1 Material, ii) See Tier 1 Material, Table 3.5-6,
Table 3.5-6, Item 1 for the Item 1 for the containment
containment atmosphere atmosphere radioactivity monitor
radioactivity monitor PSS-RE027. PSS-RE027.
iii) See Tier 1 Material, iii) See Tier 1 Material,
Table 2.1.2-4, Items 5a, 7a, and 10 Table 2.1.2-4, Items 5a, 7a, and 10
for the pressurizer level measuring for the pressurizer level measuring
instruments RCS-195A, instruments RCS-195A,
RCS-195B, RCS-195C, and RCS-195B, RCS-195C, and
RCS-195D. RCS-195D.
iv) See Tier 1 Material, iv) See Tier 1 Material,
Table 2.1.2-4, Items 5a and 7a for Table 2.1.2-4, Items 5a and 7a for
the RCS hot and cold leg the RCS hot and cold leg
temperature instruments RCS- temperature instruments RCS-
121A, RCS-121B, RCS-121C, 121A, RCS-121B, RCS-121C,
RCS-121D, RCS-122A, RCS-121D, RCS-122A,
RCS-122B, RCS-122C, RCS-122B, RCS-122C,
RCS-122D, RCS-131A, RCS-122D, RCS-131A,
RCS-131B, RCS-131C, RCS-131B, RCS-131C,
RCS-131D, RCS-132A, RCS-131D, RCS-132A,
RCS-132B, RCS-132C, and RCS-132B, RCS-132C, and
RCS-132D. RCS-132D.
v) See Tier 1 Material, v) See Tier 1 Material,
Table 2.1.2-4, Items 5a, 7a, and 10 Table 2.1.2-4, Items 5a, 7a, and 10
for the RCS pressure instruments for the RCS pressure instruments
RCS-140A, RCS-140B, RCS- RCS-140A, RCS-140B, RCS-
140C, and RCS-140D. 140C, and RCS-140D.
vi) See Tier 1 Material, vi) See Tier 1 Material,
Table 2.3.2-4, Item 13 for the Table 2.3.2-4, Item 13 for the
letdown and makeup flow letdown and makeup flow
instruments CVS-001 and instruments CVS-001 and
CVS-025. CVS-025.
vii) See Tier 1 Material, vii) See Tier 1 Material,
Table 2.3.10-4, Item 10 for the Table 2.3.10-4, Item 10 for the
reactor coolant drain tank level reactor coolant drain tank level
instrument WLS-002. instrument WLS-002.

Tier 1 Material 3.6-2 Revision 19