Professional Documents
Culture Documents
HCAC-CA-F01
Design and specifications are subject to change without notice. Pictures and diagrams are for reference only and are subject to change without notice.
All rights reserved by Qingdao Hisense HVAC Equipment Co.,Ltd.
BUSINESS
LAYOUT
Multimedia
TV and Display Devices
Internet TV Operation
Mobile Communication Devices
Optical Communication
Devices
Chip
Household
Appliances
Refrigerator
Freezer
Air-conditioner
Washing Machine
Kitchen Appliance
IT Smart Systems
Smart City
Smart Community
Smart Transportation
Smart Business
Medical Electronic Devices
Smart Home System and Service
Official Sponsor of the Title Sponsor of Hisense 300 Team Supplier to Official Partner of Official Sponsor of Official Partner of
Australian Open NASCAR Xfinity Series and Team Red Bull Racing UEFA EURO 2016 the 2018 FIFA World Cup UEFA EURO 2020
Sponsor of Joe Gibbs Racing
Russia
R&D
R&D
R&D
R&D
R&D
R&D
Americas Yangzhou
Middle Xi'an R&D
R&D Shanghai
South Asia Chengdu
East Asia Huzhou
Thailand Wuhan R&D
Cambodia Vietnam
Guiyang R&D
R&D Changsha
R&D
R&D Center 18
Africa
Branch of CAC 11
266,000 m 2
40+
Manufacturing Area Production Line
MANUFACTURING
BASE
09 10
Outdoor Unit Connection Tables
11 17
Indoor Unit Heat Recovery
Ventilator
19 21
Control System Accessory
22
Feature Explanation
CONTENTS
High Intelligence High Intelligence
A variety of controllers can be chosen for the central air conditioning systems, which enable you easy and Hi-Smart F series unit can be connected to the air conditioning central control systems, such as Smart
intelligent control of your air conditioners. You can choose the one which best suits for your air conditioning Touch, Hi-Mit and Hi-Dom system. It’s available to manage all the air conditioners easily and conveniently.
management.
Smart Touch
Outdoor Unit
Indoor Unit
Hi-Mit
Outdoor Unit
Indoor Unit
Hi-Dom
Outdoor Unit
01 02
The indoor unit can be interlocked with various types of input signals such as room card, window sensor, fire Hi-Smart F series unit can also be connected with the building management system based on the Modbus
alarm signal etc. by using dry contact signal. Thus the air conditioner can be automatically operated de- communication protocol.
pending on situation.
Communication Bus
Modbus
High Reliability High Reliability
-5℃ -16.5℃
More Stable Energy-saving Fully Lubrication Fast Start Note: When the ambient temperature is between -5℃ and 10℃, the units (AMW-18HGFAE2, AMW-24/28HGFAE3) is in intermittent operation under cooling mode.
without Heating Belt
03 04
Condensate Water Leakage Protection
Brand-new Corrugated IPM Cooling Device
There are built-in water-leakage float switches inside the indoor units. When the condensate water reach-
es a certain level, alarming warning will be displayed on the controllers and indoor units will shut down au-
A brand-new cooling device is adopted to cool the IPM, which has a large heat exchange area by using
tomatically.�
corrugated shape, ensuring the reliability of IPM. Thanks to this device, the outdoor unit can work at a
higher frequency to improve the cooling capacity output especially the outdoor temperature is extremely
high.
Alarm
vs
Normal
Auto Restart
The system is capable to operate back to previous last setting when power supply is restored from sudden
power cut-off.
High Flexibility High Flexibility
As a central air conditioning system solution, Max. 4 indoor units can be connected to 1 outdoor unit. It
would drastically reduce the space required for placing a number of outdoor units compared with the single
split unit. �
L1 L2 L3 L4 H1
Pipe length:
≤20m ≤20m ≤25m ≤30m ≤30m
L1, L2, L3, L4
H2
05 Height difference between
≤5m ≤5m ≤5m ≤7.5m ≤7.5m 06
IDUs: H2
12 models from 3 types of indoor units are lined up in the capacity ranged from 2.0kW to 7.1kW, which will
satisfy the wide range of requirements from private apartments, large shops and hotels. Also they can be
combined freely with connection ratio from 70% to 135%, which increases the freedom of design greatly. Automatic Error Correction
The system will automatically detect whether the EEV of the outdoor unit is connected with the right indoor
unit according the presetting, and automatically adjust the corresponding relationship, which is very conve-
nient for installation and communication.
Convenient Maintenance
Convenient Installation
Exclusive Hi-Checker is an plug and play service
Automatic detection
No welding is required for the piping work and all the connec- tool for system monitoring purposes. Whereby through computer
tions are connected via flare-nuts, which is very convenient and various parameters can be monitored in real-time
cost-saving. Besides, no need to charge additional refrigerant if which made troubleshooting and maintenance
the pipe length less than 40m*. much more simple.
≤40m
No welding No additional refrigerant
* Take the outdoor unit AMW-36/42HGFAE4 as an example. charging
Hi-Checker Outdoor unit Indoor Unit
Best Comfort Best Comfort
There are multiple temperature sensors equipped in the system, including one temperature sensor inside To keep up with the indoor quality requirements, the indoor units can offer auto dehumidification function
the wired controller, which will be very useful to adjust indoor unit capacity output accurately according to and it can be achieved by choosing a humidity sensor with control range from 35% to 90%.
actual indoor load. What’s more, the setting accuracy of wired controller is ±0.5℃, making the indoor tem-
perature always steady.
℃ 30
Room Temp.
29
Too hot 28
27
Comfortable Airflow
Outdoor Unit Night Quiet Mode
07 08
A 3D airflow panel with LED temperature and humidity display
is available as an optional accessory for the low-height For areas where there are strict limitations to sound levels, the outdoor unit sound level can be reduced
ducted indoor units. The 3D louvers on the panel can offer during the night time to meet the requirement by doing corresponding setting. Max.6 dB(A) can be reduced
+20%
even airflow and wide airflow coverage to keep every corners under night quiet mode.
of your room cool or warm.
0° 8hrs 9hrs*
Peak Temp
-45° 45°
60°
Night Mute Mode
AirPure (Optional) Min. 6dB(A)
35dB(A)
The indoor unit can be equipped with AirPure kit, which 8:00 12:00 16:00 20:00 0:00 4:00 8:00
can release lots of negative ions, about 20 million pcs/cc.
*The night mute mode can last for 8hrs, 9hrs or 10hrs according to the setting. Temp Change Curve
These negative ions are carried throughout the room Take AMW-24HGFAE3 as an example Noise Change Curve
When the unit is under cooling operation or heating operation above -10℃*, it can start immediately when
powered on, no need to be preheated, achieving quickly cool and heat.
Anti-Bacteria and Formaldehyde Anti-mold Odor PM2.5 Anti-allergen
Anti-Virus Removal Removal Purification * For the outdoor unit AMW-18HGFAE2, preheating of the outdoor unit is not needed at -5℃ and above ambient temperature.
Outdoor Units Connection Tables
NOTES:
1200mm 1.The nominal cooling capacity and heating capacity are based on the following conditions:
Cooling Operation Conditions: Indoor Air Inlet Temperature: 27℃ DB(80℉ DB), 19.0℃ WB(66.2℉ WB)
Outdoor Air Inlet Temperature: 35℃ DB(95℉ DB)
Heating Operation Conditions: Indoor Air Inlet Temperature: 20℃ DB(68℉ DB).
Outdoor Air Inlet Temperature: 7℃ DB(45℉ DB), 6℃ WB(43℉ WB)
Air Supply Air Return 2.The above noise values are measured in an anechoic chamber so that reflected sound should be taken into consideration during actual operation.
Indoor Unit Indoor Unit
Console Type
Console Type
ECO 0.5
Standard Standard Optional Optional Optional
kW 3.5 5.0
Capacity
Btu/h 11900 17100
Cooling
13 Power Input W 14 23
14
Standing on the floor Hanging on the wall
kW 4.0 5.6
Capacity
13600 19100
Cool Mode Heating
Btu/h
Power Input W 14 23
Air Inlet
Air Inlet Air Inlet Drain Pipe mm OD. 18 OD. 18
Side
NOTES:
Back
1.The nominal cooling capacity and heating capacity are based on the following conditions:
Cooling Operation Conditions: Indoor Air Inlet Temperature: 27℃ DB(80℉ DB), 19.0℃ WB(66.2℉ WB)
Air Outlet Outdoor Air Inlet Temperature: 35℃ DB(95℉ DB)
Bottom
Side
Heating Operation Conditions: Indoor Air Inlet Temperature: 20℃ DB(68℉ DB).
Outdoor Air Inlet Temperature: 7℃ DB(45℉ DB), 6℃ WB(43℉ WB)
2.The above noise values are measured in an anechoic chamber so that reflected sound should be taken into consideration during actual operation.
Indoor Unit Indoor Unit
ECO
Standard Standard Optional Optional
the tap of a button in the controller, which is very controller, and the wall mounted unit will work in the Rated Current A 0.28 0.34 0.34
convenient and saves the cost of manual cleaning, lowest fan speed to ensure a quiet environment.
Air Flow m3/min 5.8/6.0/7.5/8.2/8.7/9.2 5.8/6.0/7.5/8.2/8.7/9.2 9.5/10.2//10.8/11.7/12.3/13.2
while ensuing a clean environment.
Noise Level dB(A) 24/25/30/32/33/35 24/25/30/32/33/35 30/32/34/35/37/39
Note: The self-cleaning function need to be activated by the wired Sleep Mode:
controller HYXE-VC01 at present. Sweet dream will come true under sleep mode, Net mm 270×845×203 270×845×203 315×960×230
Dimension
during which the setting temperature will be (H×W×D)
Packaging mm 375×943×310 375×943×310 430×1058×328
Ⅰ changed automatically for more comfort.
Heating Net kg 8.5 8.5 11.5
Weight
Gross kg 12.0 12.0 16.5
Flexible Installation
Connection Type - Flare-nuts
Refrigerant and condensated water outlet direction
Gas mm 12.7 12.7 12.7
Ⅳ Ⅱ can be left, right or rear as the installation situation Piping
Before After
Dry Frost requires. Liquid mm 6.35 6.35 6.35
NOTES:
1.The nominal cooling capacity and heating capacity are based on the following conditions:
Ⅲ Cooling Operation Conditions: Indoor Air Inlet Temperature: 27℃ DB(80℉ DB), 19.0℃ WB(66.2℉ WB)
Right
Defrost Outdoor Air Inlet Temperature: 35℃ DB(95℉ DB)
Heating Operation Conditions: Indoor Air Inlet Temperature: 20℃ DB(68℉ DB).
Back Outdoor Air Inlet Temperature: 7℃ DB(45℉ DB), 6℃ WB(43℉ WB)
4 processes for deep cleaning Left 2.The above noise values are measured in an anechoic chamber so that reflected sound should be taken into consideration during actual operation.
Heat Recovery Ventilator Heat Recovery Ventilator
Product Dimensions
Fan motor Air Return
Air Exhaust Indoor dirty
Dirty air exhaust air exhaust
Electric
Control
Box
Model L L1 W W1 W2 H C N H1
Air Intake-- Blowing-in--
Outdoor fresh Clean air blown indoor
air intake HKF-15B2EC 665 723 580 514 290 265 90 Φ144 20
Compact Body, Convenient Installation
HKF-25B2EC 250 250 190 57 57 59 63 63 68 85 65 60 0.66 0.56 0.52 2×0.069 2×0.055 2×0.049 32 31 28 30
220-240V
HKF-35B2EC 350 350 270 55 55 57 62 62 65 100 75 65 0.76 0.75 0.71 2×0.083 2×0.079 2×0.075 34 33 31 35
/50HZ
HKF-50B2EC 500 500 400 56 56 58 63 63 65 130 110 100 1.82 1.71 1.52 2×0.189 2×0.157 2×0.124 39 38 36 40
Control System Control System
Wireless
Wired Controller Central Controller Central Control Adapter
Controller
Model Model
HCCS-H160H2C1YM
HYXM-VB01 HYXE-VA01 HYXE-VC01 HYXE-J01H HYXE-S01H HYE-W01 HYJ-J01H HYJM-S01H HYJE-H01H HCPC-H2M1C
HCCS-H160H2C1NM
Picture Picture
Size (mm) 86×90 120×120 86×86 120×120 120×70 Size 145×55 120×120 220×148 - - -
Max. connectable indoor units 6 16 6 16 16 Max. connectable indoor units - 128 160 32 160 64
Cooling/Heating/Auto Cooling/Heating/Auto
Dehumidification Dehumidification
Health(AirPure) Health(AirPure)
Hi-Motion Hi-Motion
Mute Mute
Sleep Sleep
Hi-Dom Adapter
HCCS-H160H2C1NM DC 12V 180×115.4×64.5 160
(Electricity Allocation Unavailable)
Humidity Sensor HCHR-S01E Low-height Ceiling Ducted Unit, Console, Wall Mounted Unit Dry Contact Interface AirPure (Optional)
The unit can be controlled by an external input signal. Achieving air purification by equipping with AirPure kit.
Optional
Hi-Motion HCM-S01E Low-height Ceiling Ducted Unit, Console, Wall Mounted Unit
Hi-Motion (Optional) Humidity Sensor (Optional)
Hi-Motion is an human presence sensor which enables Indoor units compatible with humidity sensor accessory
Low-height Ceiling Ducted Unit AME-07/09/12* auto ON/OFF, auto fan and temperature setting based could access to Auto Dehumidification function on the
HP-CB-NA Optional on human activity. Optional indoor unit.
3D Airflow Panel