You are on page 1of 16

Qingdao Hisense HVAC Equipment Co.,Ltd.

Hisense Tower, Qingdao, China

http://www.hisense-vrf.com export@hisensehitachi.com @HisenseVRFGlobal Hisense VRF Hisense VRF

HCAC-CA-F01

Design and specifications are subject to change without notice. Pictures and diagrams are for reference only and are subject to change without notice.
All rights reserved by Qingdao Hisense HVAC Equipment Co.,Ltd.
BUSINESS
LAYOUT
Multimedia
TV and Display Devices
Internet TV Operation
Mobile Communication Devices
Optical Communication
Devices
Chip

Household
Appliances
Refrigerator
Freezer
Air-conditioner
Washing Machine
Kitchen Appliance

IT Smart Systems
Smart City
Smart Community
Smart Transportation
Smart Business
Medical Electronic Devices
Smart Home System and Service

Real Estate &


Modern Services
Real Estate
High-end Plaza Chains

SINCE 1969 Mould Design and Manufacturing


Finance
Trade
Hisense Group is a well-known large-scale electronic information industry group company.
Based on technology and focusing on innovation-oriented culture, its scientific and efficient
technological innovation system makes Hisense always be at the forefront of the counterparts.
Hisense brand family has continued to grow with Toshiba, Gorenje and ASKO. Multi-brand
operations will be defined according to Group's Strategy Management Department.
Hisense has started a long-term sports marketing strategy to increase brand awareness worldwide.
GLOBAL VOICE After the successful sponsorship of UEFA EURO 2016 and 2018 FIFA WORLD CUP, Hisense has made
clear its focus on football. And now, Hisense becomes the official partner of UEFA EURO 2020.

2014 2015 2016 2018 2020

Official Sponsor of the Title Sponsor of Hisense 300 Team Supplier to Official Partner of Official Sponsor of Official Partner of
Australian Open NASCAR Xfinity Series and Team Red Bull Racing UEFA EURO 2016 the 2018 FIFA World Cup UEFA EURO 2020
Sponsor of Joe Gibbs Racing

Russia

R&D

R&D
R&D
R&D
R&D

R&D Western Europe Central Asia


R&D
R&D Eastern
R&D Europe CHINA Qingdao R&D

R&D
Americas Yangzhou
Middle Xi'an R&D
R&D Shanghai
South Asia Chengdu
East Asia Huzhou
Thailand Wuhan R&D

Cambodia Vietnam
Guiyang R&D
R&D Changsha

Shunde R&D R&D Shenzhen


Jiangmen
Production Base 14

R&D
R&D Center 18

Africa
Branch of CAC 11
266,000 m 2
40+
Manufacturing Area Production Line
MANUFACTURING
BASE

Qingdao Hisense HVAC Equipment Co., Ltd. is a wholly owned


subsidiary of Qingdao Hisense Hitachi Air-conditioning Sys-
tems Co., Ltd., who is a joint-venture of Hisense and Hitachi
(changed to Johnson Control Hitachi in 2015) and was estab-
lished in 2003.
6,000,000units/year 16,700 m /70+ 2

It integrates technology development for commercial and Production Capacity Laboratory


residential central air conditioners, product manufacturing, 02
marketing and service as a whole. With the full support of all the
shareholders such as Hisense and Johnson Control Hitachi,
Hisense VRF is committed to becoming the market leader in the 01
industry.

With solid technical innovation strength, Hisense VRF has


participated in the formulation and revision of 25 national stan-
dards, industry standards and association standards, and has 03
420 authorized patents in the field of CAC and heat pump prod-
ucts. Since 2008, 58 technologies have reached the advanced
level through authorized certification. Now Hisense VRF has
become a leading CAC enterprise in China.

Note: The above data is valid before Dec. 31th, 2019.


01 03 CUSTOMIZE
High Intelligence High Reliability
BETTER
LIFE
05 07
High Flexibility Best Comfort

09 10
Outdoor Unit Connection Tables

11 17
Indoor Unit Heat Recovery
Ventilator

19 21
Control System Accessory

22
Feature Explanation

CONTENTS
High Intelligence High Intelligence

Various Controllers Choice Air Conditioning Central Control Solution

A variety of controllers can be chosen for the central air conditioning systems, which enable you easy and Hi-Smart F series unit can be connected to the air conditioning central control systems, such as Smart
intelligent control of your air conditioners. You can choose the one which best suits for your air conditioning Touch, Hi-Mit and Hi-Dom system. It’s available to manage all the air conditioners easily and conveniently.
management.

Indoor Unit Indoor Unit Indoor Unit

Smart Touch
Outdoor Unit
Indoor Unit

Hi-Mit
Outdoor Unit
Indoor Unit

Hi-Dom

Outdoor Unit

01 02

Interlocking Solution Using Dry Contact Integration Solution with BMS

The indoor unit can be interlocked with various types of input signals such as room card, window sensor, fire Hi-Smart F series unit can also be connected with the building management system based on the Modbus
alarm signal etc. by using dry contact signal. Thus the air conditioner can be automatically operated de- communication protocol.
pending on situation.
Communication Bus

Light Curtain Alarm Equipment


Outdoor Unit

Indoor Unit Indoor Unit Indoor Unit


Fire and Smoke Alarm:
Outdoor units automatically turn
off when alarm is activated to Modbus
ensure user's safety.

Outdoor Unit Indoor Unit


Key-card:
The indoor unit turns
on only when key-card
is inserted.
Modbus

Window Contact Design: Outdoor Unit Indoor Unit


The indoor unit turns on only when
windows are closed

Modbus
High Reliability High Reliability

Reliability Is Guaranteed Thanks Wide Operation Range


to the Rotary Compressor
Extended operation range creates wider application potential. Hi-Smart F series unit can operate stably in
The rotor compressor adopts the Hisense exclu- a wide ambient temperature range: from -5*℃DB to 48℃ DB in cooling mode and from -16.5℃ WB to18℃
sive technology of six-pulse heating which can WB in heating mode.
ensure effective oil lubrication. Thus the com-
pressor can work in a more stable state. What’s DB WB
more, with this technology, the heating belt out-
48℃ 18℃
side the compressor can be cancelled, saving
the power consumption of heating belt in standby
mode.

-5℃ -16.5℃

Cooling Mode Heating Mode

More Stable Energy-saving Fully Lubrication Fast Start Note: When the ambient temperature is between -5℃ and 10℃, the units (AMW-18HGFAE2, AMW-24/28HGFAE3) is in intermittent operation under cooling mode.
without Heating Belt

03 04
Condensate Water Leakage Protection
Brand-new Corrugated IPM Cooling Device
There are built-in water-leakage float switches inside the indoor units. When the condensate water reach-
es a certain level, alarming warning will be displayed on the controllers and indoor units will shut down au-
A brand-new cooling device is adopted to cool the IPM, which has a large heat exchange area by using
tomatically.�
corrugated shape, ensuring the reliability of IPM. Thanks to this device, the outdoor unit can work at a
higher frequency to improve the cooling capacity output especially the outdoor temperature is extremely
high.

Alarm
vs
Normal

With float switch Without float switch


No need to warry about water leakage. No warning for water leakage risk,
and the indoor ceiling may be destroyed.

Auto Restart

The system is capable to operate back to previous last setting when power supply is restored from sudden
power cut-off.
High Flexibility High Flexibility

Space-saving Installation Long Piping Capability

As a central air conditioning system solution, Max. 4 indoor units can be connected to 1 outdoor unit. It
would drastically reduce the space required for placing a number of outdoor units compared with the single
split unit. �

L1 L2 L3 L4 H1

AMW-18 AMW-24 AMW-28 AMW-36 AMW-42


Content
HGFAE2 HGFAE3 HGFAE3 HGFAE4 HGFAE4

Pipe length:
≤20m ≤20m ≤25m ≤30m ≤30m
L1, L2, L3, L4

Height difference between


Split Unit Hi-Smart F series ≤7.5m ≤7.5m ≤7.5m ≤10m ≤10m
ODU and IDU: H1

H2
05 Height difference between
≤5m ≤5m ≤5m ≤7.5m ≤7.5m 06
IDUs: H2

Flexible Combination with Various Indoor Units Total pipe length:


≤35m ≤50m ≤60m ≤70m ≤70m
L1+L2+L3+L4

12 models from 3 types of indoor units are lined up in the capacity ranged from 2.0kW to 7.1kW, which will
satisfy the wide range of requirements from private apartments, large shops and hotels. Also they can be
combined freely with connection ratio from 70% to 135%, which increases the freedom of design greatly. Automatic Error Correction

The system will automatically detect whether the EEV of the outdoor unit is connected with the right indoor
unit according the presetting, and automatically adjust the corresponding relationship, which is very conve-
nient for installation and communication.

Convenient Maintenance
Convenient Installation
Exclusive Hi-Checker is an plug and play service
Automatic detection
No welding is required for the piping work and all the connec- tool for system monitoring purposes. Whereby through computer
tions are connected via flare-nuts, which is very convenient and various parameters can be monitored in real-time
cost-saving. Besides, no need to charge additional refrigerant if which made troubleshooting and maintenance
the pipe length less than 40m*. much more simple.

≤40m
No welding No additional refrigerant
* Take the outdoor unit AMW-36/42HGFAE4 as an example. charging
Hi-Checker Outdoor unit Indoor Unit
Best Comfort Best Comfort

Precise Temperature Control Humidity Sensor (Optional)

There are multiple temperature sensors equipped in the system, including one temperature sensor inside To keep up with the indoor quality requirements, the indoor units can offer auto dehumidification function
the wired controller, which will be very useful to adjust indoor unit capacity output accurately according to and it can be achieved by choosing a humidity sensor with control range from 35% to 90%.
actual indoor load. What’s more, the setting accuracy of wired controller is ±0.5℃, making the indoor tem-
perature always steady.

℃ 30
Room Temp.
29

Too hot 28

27

Comfortable 26 Small temp. fluctuation


25
Setting Temp.
24
Too cool
Conventional
23
Hisense Hi-Smart F Series Before After
22 Time

Comfortable Airflow
Outdoor Unit Night Quiet Mode
07 08
A 3D airflow panel with LED temperature and humidity display
is available as an optional accessory for the low-height For areas where there are strict limitations to sound levels, the outdoor unit sound level can be reduced
ducted indoor units. The 3D louvers on the panel can offer during the night time to meet the requirement by doing corresponding setting. Max.6 dB(A) can be reduced
+20%
even airflow and wide airflow coverage to keep every corners under night quiet mode.
of your room cool or warm.

0° 8hrs 9hrs*

Peak Temp
-45° 45°
60°
Night Mute Mode
AirPure (Optional) Min. 6dB(A)
35dB(A)

The indoor unit can be equipped with AirPure kit, which 8:00 12:00 16:00 20:00 0:00 4:00 8:00
can release lots of negative ions, about 20 million pcs/cc.
*The night mute mode can last for 8hrs, 9hrs or 10hrs according to the setting. Temp Change Curve
These negative ions are carried throughout the room Take AMW-24HGFAE3 as an example Noise Change Curve

with air-conditioned air flow whereby obtaining air condi-


tioning and air purification simultaneously.
*Available for the low-height ceiling ducted unit and console unit. Fast Start, No Need Preheating for ODU

When the unit is under cooling operation or heating operation above -10℃*, it can start immediately when
powered on, no need to be preheated, achieving quickly cool and heat.
Anti-Bacteria and Formaldehyde Anti-mold Odor PM2.5 Anti-allergen
Anti-Virus Removal Removal Purification * For the outdoor unit AMW-18HGFAE2, preheating of the outdoor unit is not needed at -5℃ and above ambient temperature.
Outdoor Units Connection Tables

Model Name AMW-18HGFAE2 AMW-24HGFAE3 AMW-28HGFAE3 AMW-36HGFAE4 AMW-42HGFAE4 Model 1 by 2 1 by 3 1 by 4

Power Supply - 220V/50Hz/1Ph 07+07 07+09


AMW-18HGFAE2 07+12 09+09
kW 5.60 7.00 8.00 10.00 11.50
Capacity 09+12 12+12
Cooling Btu/h 19100 23900 27300 34100 39200 07+16 07+18 07+07+07 07+07+09
Power Input kW 1.42 1.94 2.28 3.05 3.60 07+24 09+16 07+07+12 07+07+16
AMW-24HGFAE3 09+18 12+12 07+09+09 07+09+12
kW 6.30 8.00 9.00 11.2 12.50
Capacity 12+16 07+12+12 09+09+09
Heating Btu/h 21500 27300 30700 38200 42700
09+09+12 07+12+12
Power Input kW 1.47 1.90 2.25 3.12 3.50 07+16 07+18 07+07+07 07+07+09
Noise Level (Cooling/Heating) dB(A) 50/53 51/53 52/54 55/57 56/58 07+24 09+18 07+07+12 07+07+16
09+16 12+12 07+07+18 07+09+09
Type - Twin Rotary Compressor
09+24 12+18 07+09+12 07+09+16
Compressor Drive Type - DC Drive AMW-28HGFAE3
12+16 16+16 07+09+18 07+12+12
09 Refrigerant Type - R410A 12+24 07+12+16 09+09+09 10
Q'ty pcs 09+09+12 09+09+16
1 1 1 1 1
12+12+12
Fan Air Flow Volume m3/min 45 45 46 80 80
07+16 07+18 07+07+16 07+07+18 07+07+07+07 07+07+07+09
Power Input W 80 80 80 138 138 07+24 09+24 07+07+24 07+09+18 07+07+07+12 07+07+07+16
H mm 670 670 670 800 800 12+12 12+16 07+09+16 07+12+12 07+07+07+18 07+07+07+24
12+18 12+24 07+09+24 07+12+18 07+07+09+09 07+07+09+12
Net Dimension W mm 900 900 900 950 950
16+16 16+18 07+12+16 07+16+16 07+07+09+16 07+07+09+18
D mm 320 320 320 320 320 16+24 18+18 07+07+09+24 07+09+09+09
07+12+24 09+09+12
AMW-36HGFAE4
H mm 735 735 735 946 946 18+24 07+16+18 09+09+18 07+09+09+12 07+09+09+16

Packaging Dimension W 09+09+16 09+12+12 07+09+09+18 09+09+09+09


mm 1070 1070 1070 1070 1070
09+09+24 09+12+18 09+09+09+12 09+09+09+16
D mm 440 440 440 472 472
09+12+16 12+12+12 09+09+09+18 09+12+12+12
Net kg 49 57 57 72 72 09+12+24 12+12+18
Weight
Gross kg 53 61 61 75 75 12+12+16 12+16+16
12+18 12+24 07+07+24 07+09+16 07+07+07+16 07+07+07+18
Connection Type - Flare-nuts
16+16 16+24 07+09+18 07+09+24 07+07+07+24 07+07+09+09
Piping Gas mm 12.7 12.7 12.7 12.7 12.7 18+18 18+24 07+12+12 07+12+16 07+07+09+12 07+07+09+16
Liquid mm 6.35 6.35 6.35 6.35 6.35 24+24 07+12+18 07+12+24 07+07+09+18 07+07+09+24

Max. Piping Length 07+16+16 07+16+18 07+09+09+09 07+09+09+12


m 20 20 25 30 30
07+16+24 07+18+18 07+09+09+16 07+09+09+18
Max. Total Piping Length m 35 50 60 70 70
07+18+24 09+09+12 07+09+09+24 07+09+12+12
Height Difference Between ODU/IDU m 7.5 7.5 7.5 10 10 09+09+16 09+09+18 07+09+12+16 07+09+12+18
Height Difference Between IDU/IDU m 5 5 5 7.5 7.5 AMW-42HGFAE4 09+09+24 09+12+12 07+09+12+24 07+12+12+12
09+12+16 09+12+18 07+12+12+16 07+12+12+18
Refirgerant Chargeless Length m 20 30 30 40 40
09+12+24 09+16+16 09+09+09+09 09+09+09+12
Cooling ℃ DB -5~48 -5~48 -5~48 -5~48 -5~48 09+16+18 09+16+24 09+09+09+16 09+09+09+18
Operation Range
Heating ℃ WB -16.5~18 -16.5~18 -16.5~18 -16.5~18 -16.5~18 12+12+16 12+12+18 09+09+09+24 09+09+12+12
12+12+24 12+16+16 09+09+12+16 09+09+12+18
NOTES:
12+16+18 16+16+16 09+12+12+12 09+12+12+16
1.The nominal cooling capacity and heating capacity are based on the following conditions: 2.The above noise values are measured in an anechoic chamber so that reflected
09+12+12+18 12+12+12+12
Cooling Operation Conditions: Indoor Air Inlet Temperature: 27℃ DB(80℉ DB), 19.0℃ WB(66.2℉ WB) sound should be taken into consideration during actual operation.
Outdoor Air Inlet Temperature: 35℃ DB(95℉ DB)
12+12+12+16
Heating Operation Conditions: Indoor Air Inlet Temperature: 20℃ DB(68℉ DB).
Outdoor Air Inlet Temperature: 7℃ DB(45℉ DB), 6℃ WB(43℉ WB)
Indoor Unit Indoor Unit

Low-height Ducted Type


Low-height Ducted Type
1200
mm
ECO 0.5
Standard Optional Optional Optional Optional

Slim Design & Space Saving Smart Temperature Control


With a height of 192mm, the unit can be installed The indoor temperature can be checked using the
inside the narrow ceiling, and it can save ceiling temp. sensors in the controllers as well as from the
spaces for higher room height without compromis- air inlet of the indoor unit. There maybe a significant
ing user’s comfort and satisfaction. difference between ceiling and floor temperature.
Two temp. sensors can optimize indoor air tem-
perature for a more comfortable environment.

192 Model Name AME-07HGFADCW AME-09HGFADCW AME-12HGFADCW AME-16HGFADCW AME-18HGFADCW AME-24HGFADCW


mm
Power Supply - 220V/50Hz/1Ph

kW 2.0 2.5 3.5 5.0 6.0 7.1


Capacity
Btu/h 6800 8500 11900 17100 20500 24200
Cooling
11 Power Input W 50 50 70 90 100 100 12
Rated Current A 0.25 0.25 0.33 0.42 0.50 0.50

Fresh Air Intake Capacity


kW 2.3 2.8 4.0 5.6 7.0 8.0

Btu/h 7800 9600 13600 19100 23900 27300


There is a fresh air hole reserved in the unit, which Heating
will allow 10% free fresh air introductory, providing Power Input W 50 50 70 90 100 100

fresh air to the indoors continuously. Flexible Installation


Rated Current A 0.25 0.25 0.33 0.42 0.50 0.50
Two levels of static pressure can be adjusted to
Air Flow m3/min 4.7/5.5/7.0 4.7/5.5/7.0 4.8/5.7/9.0 8.0/8.8/14.5 8.7/9.3/16.5 8.7/9.3/16.5
meet the needs of different installation situations.
Noise Level dB(A) 24/26/30 24/26/30 24/27/34 26/29/35 27/30/37 27/30/37
Fresh Air
Duct ESP Pa 10/30 10/30 10/30 10/30 10/30 10/30

Net mm 192×700×447 192×1180×447


Air Supply Dimension
(H×W×D)
Packaging mm 270×925×574 270×1406×574

Net kg 15.8 15.8 16.8 24.4 24.6 24.6


Standard DC Drain Pump Weight
Gross kg 19.0 19.0 20.0 29.0 29.0 29.0
A DC drain pump with 1200mm pump head is fitted
Connection Type - Flare-nuts
as standard. It can greatly simplify the installation of
Air Return
drain piping and reduce the ceiling thickness. Be- Gas mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88
Piping
sides, the operation is more quiet and energy-sav- Liquid mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35
Duct
ing compared with the conventional AC drain pump.
Drain Pipe mm O.D. 32 O.D. 32 O.D. 32 O.D. 32 O.D. 32 O.D. 32

NOTES:

1200mm 1.The nominal cooling capacity and heating capacity are based on the following conditions:
Cooling Operation Conditions: Indoor Air Inlet Temperature: 27℃ DB(80℉ DB), 19.0℃ WB(66.2℉ WB)
Outdoor Air Inlet Temperature: 35℃ DB(95℉ DB)
Heating Operation Conditions: Indoor Air Inlet Temperature: 20℃ DB(68℉ DB).
Outdoor Air Inlet Temperature: 7℃ DB(45℉ DB), 6℃ WB(43℉ WB)
Air Supply Air Return 2.The above noise values are measured in an anechoic chamber so that reflected sound should be taken into consideration during actual operation.
Indoor Unit Indoor Unit

Console Type
Console Type

ECO 0.5
Standard Standard Optional Optional Optional

Flexible Air Supply Mode, Flexible Installation Options


More Comfort Airflow Despite of the suitability of floor installment for con-
The unit is equipped with 3 air inlets and 2 air out- sole units, it is still available for wall mounting too.
lets, which provides flexible air supply modes. For a sleek look, the unit could also be installed
During the cooling operation, the vane adjusts up- semi-concealed or totally concealed to be used as
wards to direct the cool air towards the ceiling. concealed floor units.
When heating, the vane directs the warm air down-
wards to balance the room temperature especially
for floor. �

Model Name AMK-12HGFAKCD AMK-16HGFAKCD


Heat Mode
Power Supply - 220V/50Hz/1Ph

kW 3.5 5.0
Capacity
Btu/h 11900 17100
Cooling
13 Power Input W 14 23
14
Standing on the floor Hanging on the wall

Rated Current A 0.2 0.2

kW 4.0 5.6
Capacity
13600 19100
Cool Mode Heating
Btu/h

Power Input W 14 23

Rated Current A 0.2 0.2

Air Flow (L/M/H) m3/min 8.2/6.8/5.3 10.1/9.0/7.3

Noise Level (L/M/H) dB(A) 30/34/39 37/41/43


Direct mounted Semi-concealed into wall Completely concealed
Net mm 630×700×225
Dimension
(H×W×D)
Packaging mm 725×790×315
4 Way Piping Connection Net kg 17.1 17.1
Weight
Both refrigerant and drainage pipes are freely to
Gross kg 21.0 21.0
connect in 4 directions.�
Connection Type - Flare-nuts
Air Outlet

Gas mm 12.7 12.7


Piping
Liquid mm 6.35 6.35

Air Inlet
Air Inlet Air Inlet Drain Pipe mm OD. 18 OD. 18

Side
NOTES:
Back
1.The nominal cooling capacity and heating capacity are based on the following conditions:
Cooling Operation Conditions: Indoor Air Inlet Temperature: 27℃ DB(80℉ DB), 19.0℃ WB(66.2℉ WB)
Air Outlet Outdoor Air Inlet Temperature: 35℃ DB(95℉ DB)
Bottom
Side
Heating Operation Conditions: Indoor Air Inlet Temperature: 20℃ DB(68℉ DB).
Outdoor Air Inlet Temperature: 7℃ DB(45℉ DB), 6℃ WB(43℉ WB)
2.The above noise values are measured in an anechoic chamber so that reflected sound should be taken into consideration during actual operation.
Indoor Unit Indoor Unit

Wall Mounted Type


Wall Mounted Type

ECO
Standard Standard Optional Optional

High-efficiency DC Fan Motor 6 Fan Speed


The power consumption of the unit with DC fan 6 indoor fan speeds are available to meet the
motor can be reduced greatly in comparison to the needs of different indoor conditions.
old AC product. The minimum power consumption
is only 20W, which is reduced by 60%. It can Rest Working Exercise
achieve low-cost operation.

60% Model Name AMS-09HGFATD AMS-12HGFATD AMS-16HGFATD

Power Supply - 220V/50Hz/1Ph

kW 2.5 3.5 5.0


Power Input Capacity
Reduced by
Btu/h 8500 11900 17100
Cooling
15 Power Input W 20 20 30
16
1 Fan Speed 2 Fan Speed 3 Fan Speed 4 Fan Speed 5 Fan Speed 6 Fan Speed Rated Current A 0.28 0.28 0.31

kW 2.8 4.0 5.6


Self-cleaning Function Multiple Comfort Modes Capacity
Btu/h 9500 13600 19100
Featured with self-cleaning technology, the evapo- Quiet Mode: Heating
rator can be self-cleaned automatically just with Quiet mode is available just by one-touch in the Power Input W 20 30 30

the tap of a button in the controller, which is very controller, and the wall mounted unit will work in the Rated Current A 0.28 0.34 0.34
convenient and saves the cost of manual cleaning, lowest fan speed to ensure a quiet environment.
Air Flow m3/min 5.8/6.0/7.5/8.2/8.7/9.2 5.8/6.0/7.5/8.2/8.7/9.2 9.5/10.2//10.8/11.7/12.3/13.2
while ensuing a clean environment.
Noise Level dB(A) 24/25/30/32/33/35 24/25/30/32/33/35 30/32/34/35/37/39
Note: The self-cleaning function need to be activated by the wired Sleep Mode:
controller HYXE-VC01 at present. Sweet dream will come true under sleep mode, Net mm 270×845×203 270×845×203 315×960×230
Dimension
during which the setting temperature will be (H×W×D)
Packaging mm 375×943×310 375×943×310 430×1058×328
Ⅰ changed automatically for more comfort.
Heating Net kg 8.5 8.5 11.5
Weight
Gross kg 12.0 12.0 16.5
Flexible Installation
Connection Type - Flare-nuts
Refrigerant and condensated water outlet direction
Gas mm 12.7 12.7 12.7
Ⅳ Ⅱ can be left, right or rear as the installation situation Piping
Before After
Dry Frost requires. Liquid mm 6.35 6.35 6.35

Drain Pipe mm O.D. 18 O.D. 18 O.D. 18

NOTES:

1.The nominal cooling capacity and heating capacity are based on the following conditions:
Ⅲ Cooling Operation Conditions: Indoor Air Inlet Temperature: 27℃ DB(80℉ DB), 19.0℃ WB(66.2℉ WB)
Right
Defrost Outdoor Air Inlet Temperature: 35℃ DB(95℉ DB)
Heating Operation Conditions: Indoor Air Inlet Temperature: 20℃ DB(68℉ DB).
Back Outdoor Air Inlet Temperature: 7℃ DB(45℉ DB), 6℃ WB(43℉ WB)

4 processes for deep cleaning Left 2.The above noise values are measured in an anechoic chamber so that reflected sound should be taken into consideration during actual operation.
Heat Recovery Ventilator Heat Recovery Ventilator

Airflow System HKF-15B2EC

Product Dimensions
Fan motor Air Return
Air Exhaust Indoor dirty
Dirty air exhaust air exhaust
Electric
Control
Box

Fan motor Blowing-in


Air Inlet Fresh air
Outdoor fresh enter house
air inlet
Air Exhaust-- Air Return-- Indoor
Dirty air exhausted dirty air exhausted
HKF-15B2EC~HKF-50B2EC

Model L L1 W W1 W2 H C N H1
Air Intake-- Blowing-in--
Outdoor fresh Clean air blown indoor
air intake HKF-15B2EC 665 723 580 514 290 265 90 Φ144 20
Compact Body, Convenient Installation

Thanks to its super compact body, the heat recovery 270


mm
ventilator can be easily installed in the narrow ceiling, Technical Parameters
which can save the ceiling space for higher room height Air Volume m3/h Enthalpy Efficiency Enthalpy Efficiency External Static Input Current A Input Power KW Noise Level dB(A) Weight
(Summer) (Winter) Pressure Pa Power
without compromising user’
s comfort and satisfaction. Model Supply kg
High Middle Low High Middle Low High Middle Low High Middle Low High Middle Low High Middle Low High Middle Low
600
17 mm HKF-15B2EC 150 150 110 58 58 60 65 65 69 85 70 65
220-240V
0.38 0.36 2×
0.31 0.041 2× 2× 30 29 28 25
18
/50HZ 0.038 0.029

Centralized Control System HKF-25B2EC~HKF-50B2EC


The heat recovery ventilator can be connected to the air-conditioning centralized control system together with Product Dimensions
Hi-Smart F series, which achieves the linkage with air conditioning system and centralized control. Thus the op-
eration is more convenient and more intelligent.�
Electric
Control
Box

Total heat exchanger


Outdoor unit Air Return--
Air Exhaust--
Indoor dirty
Dirty air exhausted
air exhausted
Model L L1 W W1 W2 H C G N H1

HKF-25B2EC 745 675 600 656 315 270 90 19 Φ144 110

HKF-35B2EC 745 675 805 861 480 270 90 19 Φ144 110


Air Intake-- Blowing-in--
Outdoor fresh Clean air HKF-50B2EC 825 755 905 961 500 270 96 19 Φ194 110
air intake blown indoor
Computer
centralized Indoor unit Indoor unit
control Technical Parameters
Air Volume m3/h Enthalpy Efficiency Enthalpy Efficiency External Static Input Current A Input Power KW Noise Level dB(A) Weight
(Summer) (Winter) Pressure Pa Power
Model Supply kg
High Middle Low High Middle Low High Middle Low High Middle Low High Middle Low High Middle Low High Middle Low

HKF-25B2EC 250 250 190 57 57 59 63 63 68 85 65 60 0.66 0.56 0.52 2×0.069 2×0.055 2×0.049 32 31 28 30
220-240V
HKF-35B2EC 350 350 270 55 55 57 62 62 65 100 75 65 0.76 0.75 0.71 2×0.083 2×0.079 2×0.075 34 33 31 35
/50HZ
HKF-50B2EC 500 500 400 56 56 58 63 63 65 130 110 100 1.82 1.71 1.52 2×0.189 2×0.157 2×0.124 39 38 36 40
Control System Control System

Feature Functions Feature Functions

Wireless
Wired Controller Central Controller Central Control Adapter
Controller
Model Model
HCCS-H160H2C1YM
HYXM-VB01 HYXE-VA01 HYXE-VC01 HYXE-J01H HYXE-S01H HYE-W01 HYJ-J01H HYJM-S01H HYJE-H01H HCPC-H2M1C
HCCS-H160H2C1NM

Picture Picture

Hi-Mit Hi-Dom Modbus

Size (mm) 86×90 120×120 86×86 120×120 120×70 Size 145×55 120×120 220×148 - - -

Max. connectable indoor units 6 16 6 16 16 Max. connectable indoor units - 128 160 32 160 64

Cooling/Heating/Auto Cooling/Heating/Auto

Dehumidification Dehumidification

Fan speed Fan speed

Louver setting Louver setting

Temperature setting Temperature setting

Operation monitoring Operation monitoring

24-hour timer 24-hour timer


19 20
7-day timer 7-day timer

Holiday setting Holiday setting

Main-sub control Main-sub control

Check function Check function

Air filter cleaning reminding Air filter cleaning reminding

Error code history display Error code history display

Auto test run Auto test run

Indoor/Outdoor PCB checking Indoor/Outdoor PCB checking

Self diagnostic function Self diagnostic function

Back light Back light

Built-in temperature sensor Built-in temperature sensor

Wireless control available Wireless control available

Health(AirPure) Health(AirPure)

Hi-Motion Hi-Motion

ECO(energy saving) ECO(energy saving)

Mute Mute

Sleep Sleep

Window contact design Window contact design

3D-air flow 3D-air flow

Self cleaning Self cleaning

Remarks: Available Unavailable Remarks: Available Unavailable


Control System Feature Explanation

Specification 1200 Quiet Mode


850mm Drain Pump (Standard)
mm
Drain Pumps help to discharge condensate water from Indoor units can offer very low sound pressure levels
Dimension Connectable during operation.
Standard the indoor unit smoothly.
Name Model Power Supply (L×W×D) Indoor Units
mm Quantity

Smart Touch Controller HYJM-S01H AC 1Φ, 220~240V/50Hz 220×148×53 64

Hi-Mit Adapter HYJE-H01H AC 1Φ, 110~240V/50Hz 215×137×38 32 Sleep Mode


Standard Filter
Washable long life synthetic fibre return air filters are The setting temperature will be changed automatically for
Hi-Dom Adapter Standard included with the unit. sweet and comfort sleep.
(Electricity Allocation Available) HCCS-H160H2C1YM DC 12V 180×115.4×64.5 160

Hi-Dom Adapter
HCCS-H160H2C1NM DC 12V 180×115.4×64.5 160
(Electricity Allocation Unavailable)

Modbus Adapter HCPC-H2M1C DC 12V 240×204×70 64


Eco Mode
Standard Wired Controller ECO When this function is activated, the temperature setting is
Note: Max. 160 indoor units can be connected to one Hi-Dom adapter, and max. 32 Hi-Dom adapters can be connected to one computer central control system. Standard
only in limited range, so as to save energy.

21 Accessory 3D Air-flow Panel


Selectable airflow settings from normal, 3D and super 0.5
0.5℃ Adjustable Temperature
Temperature can be increased or decreased by ±0.5 ℃
22
long distance mode are available thanks to the 3D
Optional to customize to your level of comfort.
air-flow panel.

Type Model Applicable Models Picture

Fresh Air Intake


Built-in Float Switch
As an optional part for Low-height Ceiling Ducted Unit Alarm Indoor units that are compatible to introduce fresh air
Wireless Controller HYE-W01 Thanks to the float switch, a warning alarm will turn up
As a standard part for Console and Wall Mounted Unit into rooms with either an optional adapter or direct con-
when condensate water can not be drained smoothly.
nection to the air return segment of the unit.

Wireless Reciever HYRE-V02H Low-height Ceiling Ducted Unit

Humidity Sensor HCHR-S01E Low-height Ceiling Ducted Unit, Console, Wall Mounted Unit Dry Contact Interface AirPure (Optional)
The unit can be controlled by an external input signal. Achieving air purification by equipping with AirPure kit.
Optional

AirPure HJK-ELZB Low-height Ceiling Ducted Unit, Console

Hi-Motion HCM-S01E Low-height Ceiling Ducted Unit, Console, Wall Mounted Unit
Hi-Motion (Optional) Humidity Sensor (Optional)
Hi-Motion is an human presence sensor which enables Indoor units compatible with humidity sensor accessory
Low-height Ceiling Ducted Unit AME-07/09/12* auto ON/OFF, auto fan and temperature setting based could access to Auto Dehumidification function on the
HP-CB-NA Optional on human activity. Optional indoor unit.
3D Airflow Panel

HP-EB-NA Low-height Ceiling Ducted Unit AME-18/22/24*

You might also like