Data sheet

Customer item no.:


Communication dated: Number: ES 8001054817
Doc. no.: Quick quote Item no.: 100
Quantity: 1 Date: 23/03/2021
Page: 1 / 12

Amacan PA4 700-470/606UTG1 Version no.: 1

Operating data
Requested flow rate 1000.000 l/s Actual flow rate 1005.747 l/s
Requested developed head 4.00 m Actual developed head 4.05 m
Pumped medium Water, surface water Efficiency 81.1 %
River water Power absorbed 49.00 kW
Not containing chemical and Pump speed of rotation 980 rpm
mechanical substances which NPSH required 6.94 m
affect the materials Minimum water level t1 with 1385.0 mm
Ambient air temperature 20.0 °C suction umbrella
Fluid temperature 20.0 °C Minimum water level t1 1776.0 mm
Fluid density 998 kg/m³ without suction umbrella

Fluid viscosity 1.00 mm²/s Design Single system 1 x 100 %


Max. power on curve 75.61 kW Performance test No
Min. allowable flow rate 771.325 l/s tolerances to ISO 9906 class
Head at min flow rate 7.04 m 2B

Design
Pump standard Submersible motor pump in Propeller nominal diameter 470.0 mm
discharge tube, international Blade pitch angle 19.0 °
execution Free passage size 100.0 mm
Precleaning by screen DN of discharge tube DN 700
distance between screen bars: 40.0 mm Direction of rotation from drive Clockwise
Design Close-coupled submersible Bearing type Anti-friction bearings
Orientation Vertical Lubrication type Grease
Shaft seal 2 mech. seals in tandem Temperature sensor PT100 With
arrangement with oil reservoir inboard
Manufacturer Burgmann Temperature sensor PT100 Without
Type MG mts
Material code SIC/SIC/NBR Color Ultramarine blue (RAL 5002)
Mechanical seal leakage float switch in leakage KSB-blue
chamber
Wear ring execution grooved casing wear ring
Increased Clearance With

Driver, accessories
Driver type Electric motor Number of poles 6
Model (make) KSB Starting mode Direct/Star-delta possible
Motor const. type KSB Sub. motor Connection mode Delta
Frequency 50 Hz Motor cooling method Surface cooling
Rated voltage 400 V Motor version U
Rated power P2 60.00 kW Cable design Rubber hose
Available reserve 22.45 % Cable entry Sealed along entire length
Rated current 118.0 A Power cable S1BN8-F 4G16
Starting current ratio 5 Number of power cables 2
Insulation class H according IEC 34-1 Control cable S1BN8-F 10G1.5
Motor enclosure IP68 Number of control cables 1
Cos phi at 4/4 load 0.84 Moisture sensor With
Motor efficiency at 4/4 load 87.3 % Cable length 10.00 m
Temperature sensor PTC resistor
Motor winding 400 / 690 V
Data sheet

Customer item no.:


Communication dated: Number: ES 8001054817
Doc. no.: Quick quote Item no.: 100
Quantity: 1 Date: 23/03/2021
Page: 2 / 12

Amacan PA4 700-470/606UTG1 Version no.: 1

Materials G1
O-Ring (412) Nitrile rubber NBR
Notes 1 Lip seal (421) Nitrile rubber NBR
precleaning by screen Casing wear ring (502.1) 1.4027+QT
Pump bowl (112) Cast iron EN-GJL-200 Motor housing (811) Grey cast iron EN-GJL-250
Bellmouth (138) Cast iron EN-GJL-200 Motor hous cover (812) Grey cast iron EN-GJL-250
Shaft (210) Chrome steel 1.4021+QT800 Motor cable (824) Chloroprene rubber
Axial propeller (ECB) (23-9) GX2CRNIMOCUN25-6-3-3 Hexagon socket head cap CrNiMo steel A4
1.4517 screw (914)
Bearing bracket (330) Grey cast iron EN-GJL-250 Material standard International (ISO, EN)
Bearing housing (350) Grey cast iron EN-GJL-250
Bearing cover (360) Grey cast iron EN-GJL-250

Packaging
Packaging category B1 Wooden or plywood case, Packaging for storage Indoor
cover provided with Outdoor storage at -40°C to +50°C for up to 3 month s. Packet
polyproylene cellular sheet, must be covered. No corrosion protection, only transport
outdoor storage up to 3 protection.
months
Packaging for transport Truck
IPPC Standard ISPM 15 Yes

Nameplates
Nameplates language International Duplicate nameplate With

Installation parts
Installation type DU Discharge tube, with Suction screen: Yes
discharge nozzle above floor Recommended - not included
and open intake chamber in our scope of devlery
Scope of supply Pump without support cable Bottom guide rib Without
Discharge tube
not included in KSB's scope
of supply.
Compact data sheet

Customer item no.:


Communication dated: Number: ES 8001054817
Doc. no.: Quick quote Item no.:100
Quantity: 1 Date: 23/03/2021
Page: 3 / 12

Amacan PA4 700-470/606UTG1 Version no.: 1

8
Qmin
Qmin Qmin Operating data
6 Pumped medium Water, surface water
Total developed head

[m] River water


4 Not containing chemical and
mechanical substances which
2
23.0
affect the materials
9.0
19.0
Ambient air temperature 20.0 °C
400 500 [l/s] 600 700 800 900 1000 1100 1200 1300 Fluid temperature 20.0 °C
13
Actual flow rate 1005.747 l/s
[m]
Actual developed head 4.05 m
NPSH req.

10
Efficiency 81.1 %
Power absorbed 49.00 kW
6
400 500 [l/s] 600 700 800 900 1000 1100 1200 1300
Pump speed of rotation 980 rpm
Operating pressure (for 1.00 bar.g
80
indicated duty conditions)
[%]
Efficiency

Min. allow. mass flow 769.78 kg/s


60
Minimum water level t1 with 1385.0 mm
suction umbrella
400 500 [l/s] 600 700 800 900 1000 1100 1200 1300
Minimum water level t1 without 1776.0 mm
80
suction umbrella
[kW]
Design Single system 1 x 100 %
Power Input

50

20
400 500 [l/s] 600 700 800 900 1000 1100 1200 1300
Driver, accessories
Flow Driver type Electric motor
Frequency 50 Hz
Design Rated voltage 400 V
Pump standard Submersible motor pump in Rated power P2 60.00 kW
discharge tube, international Available reserve 22.45 %
execution Rated current 118.0 A
Design Close-coupled submersible Starting current ratio 5
Orientation Vertical Insulation class H according IEC 34-1
Shaft seal 2 mech. seals in tandem Motor enclosure IP68
arrangement with oil reservoir Temperature sensor PTC resistor
Material code SIC/SIC/NBR Motor winding 400 / 690 V
Propeller nominal diameter 470.0 mm Starting mode Direct/Star-delta possible
Blade pitch angle 19.0 ° Cable design Rubber hose
Free passage size 100.0 mm Cable length 10.00 m
DN of discharge tube DN 700
Direction of rotation from drive Clockwise
Temperature sensor PT100 With Installation parts
inboard Installation type DU Discharge tube, with
Temperature sensor PT100 Without discharge nozzle above floor
mts and open intake chamber
Scope of supply Pump without support cable
Suction screen: Recommended Yes
Materials G1 - not included in our scope of
Pump bowl (112) Cast iron EN-GJL-200 devlery
Bellmouth (138) Cast iron EN-GJL-200 Bottom guide rib Without
Shaft (210) Chrome steel 1.4021+QT800
Axial propeller (ECB) (23-9) GX2CRNIMOCUN25-6-3-3
1.4517
Material standard International (ISO, EN)
Performance curve

Customer item no.:


Communication dated: Number: ES 8001054817
Doc. no.: Quick quote Item no.:100
Quantity: 1 Date: 23/03/2021
Page: 4 / 12

Amacan PA4 700-470/606UTG1 Version no.: 1

8
Qmin
Qmin Qmin

6
Total developed head

[m]

2
23.0
9.0
19.0

400 500 [l/s] 600 700 800 900 1000 1100 1200 1300
13

[m]
NPSH req.

10

6
400 500 [l/s] 600 700 800 900 1000 1100 1200 1300

80

[%]
Efficiency

60

400 500 [l/s] 600 700 800 900 1000 1100 1200 1300
80

[kW]
Power Input

50

20
400 500 [l/s] 600 700 800 900 1000 1100 1200 1300
Flow
Curve data
Speed of rotation 980 rpm Efficiency 81.1 %
Fluid density 998 kg/m³ Power absorbed 49.00 kW
Viscosity 1.00 mm²/s NPSH required 6.94 m
Flow rate 1005.747 l/s Curve number K4200310s
Requested flow rate 1000.000 l/s Impeller diameter 470.0 mm
Total developed head 4.05 m Blade pitch angle 19.0 °
Requested developed head 4.00 m
Speed curve

Customer item no.:


Communication dated: Number: ES 8001054817
Doc. no.: Quick quote Item no.:100
Quantity: 1 Date: 23/03/2021
Page: 5 / 12

Amacan PA4 700-470/606UTG1 Version no.: 1

8
Qmin

6
Total developed head

[m]

980 1/min

0
0 200 [l/s] 400 600 800 1000 1200
13

[m]
NPSH req.

10

6
0 200 [l/s] 400 600 800 1000 1200

80

[%]
Efficiency

60

0 200 [l/s] 400 600 800 1000 1200


80

[kW]
Power Input

50

20
0 200 [l/s] 400 600 800 1000 1200
Flow
Curve data
Fluid density 998 kg/m³ Total developed head 4.05 m
Viscosity 1.00 mm²/s Requested developed head 4.00 m
Flow rate 1005.747 l/s Effective impeller diameter 0.0 mm
Requested flow rate 1000.000 l/s
Motor data sheet

Customer item no.:


Communication dated: Number: ES 8001054817
Doc. no.: Quick quote Item no.:100
Quantity: 1 Date: 23/03/2021
Page: 6 / 12

Amacan PA4 700-470/606UTG1 Version no.: 1

Motor data
Motor manufacturer KSB Starting mode Direct/Star-delta possible
Motor size 60T Power cable S1BN8-F 4G16
Motor construction type KSB Sub. motor Number of power cables 2
Motor material Grey cast iron EN-GJL-250 Power cable Ø min. 22.5 mm
Efficiency class not classified Power cable Ø max. 23.9 mm
Rated voltage 400 V Control cable S1BN8-F 10G1.5
Frequency 50 Hz Number of control cables 1
Motor power 60.00 kW Ctrl. cable diameter, min. 15.9 mm
Rated current 118.0 A Ctrl. cable diameter, max. 16.9 mm
Rated speed 976 rpm Cable standard VDE
Starting current ratio 5 Switching frequency 10.00 1/h
Curve data
The no-load point is not a guarantee point within the meaning of IEC 60034
Load 0.0 % 25.0 % 50.0 % 75.0 % 100.0 %
P2 0.00 kW 15.00 kW 30.00 kW 45.00 kW 60.00 kW
n 1000 rpm 994 rpm 988 rpm 982 rpm 976 rpm
P1 2.90 kW 18.43 kW 34.44 kW 51.43 kW 68.73 kW
I 48.2 A 55.0 A 72.0 A 94.0 A 118.0 A
Eta 0.0 % 81.4 % 87.1 % 87.5 % 87.3 %
cos phi 0.09 0.48 0.69 0.79 0.84
Motor data sheet

Customer item no.:


Communication dated: Number: ES 8001054817
Doc. no.: Quick quote Item no.:100
Quantity: 1 Date: 23/03/2021
Page: 7 / 12

Amacan PA4 700-470/606UTG1 Version no.: 1

1000
[rpm]
n
970
0 10 [kW] 20 30 40 50 60

180
eta

160 80 0.8 80

140 cos phi


P1

120 60 0.6 60

100

80 40 0.4 40
I

60 [kW] [1] [%]

40 20 0.2 20

[A]

20

0 0 0.0 0
0 10 [kW] 20 30 40 50 60
mechanical pow er P2
Installation plan

Customer item no.:


Communication dated: Number: ES 8001054817
Doc. no.: Quick quote Item no.:100
Quantity: 1 Date: 23/03/2021
Page: 8 / 12

Amacan PA4 700-470/606UTG1 Version no.: 1

80

ø 40

2190
ø 711
45°
8

2150
ø 385
420

ø 675
1500 ø 600
ø 710 1)

ø 1100

Dimensions of the discharge tube


735

430 1) Suction umbrella ;


option for reducing the minimum water level

ø 585

ø 585

Drawing is not to scale Dimensions in mm

Motor Connections
Motor manufacturer KSB Rated pressure disch. PN 6
Motor size 60T
Motor power 60.00 kW
Number of poles 6
Speed of rotation 976 rpm Weight net
Pump, Motor, Cable 925 kg
Total 925 kg

The discharge line must be connected to the discharge tube without transmitting
any stresses or strains.
Dimensions without tolerances, middle tolerances to: ISO 2768-mH
Connection dimensions for pumps: EN735
Installation plan

Customer item no.:


Communication dated: Number: ES 8001054817
Doc. no.: Quick quote Item no.:100
Quantity: 1 Date: 23/03/2021
Page: 9 / 12

Amacan PA4 700-470/606UTG1 Version no.: 1

X DN2 max 400


DN2 min 400
650

650

1)
ø 711 230

min 2400 10
2)
45°
7) 1200
1385 Bottom guide rib

420
ø 710 380 1) Venting Tube
ø 1100
B - B
1050 650
2) Minimum water level t1

3) Inflow, v max.= 1m/s


5)
3)
1500
4) Foundation Holes
0-10' 0

5) Bottom guide rib


4) 0 45'
860 6) (Without pump)
420
960 860
ø 600 7) 1.1x water level, max 2x t1

6)
200 200
610 Foundation Holes
1160
300 Support plate-dischrge column

250
930
200

Drawing is not to scale

General arrangement drawing, installation example


Installation plan

Customer item no.:


Communication dated: Number: ES 8001054817
Doc. no.: Quick quote Item no.:100
Quantity: 1 Date: 23/03/2021
Page: 10 / 12

Amacan PA4 700-470/606UTG1 Version no.: 1

DU Discharge tube, with discharge nozzle above floor and


open intake chamber

Design of the intake chamber wall surfaces (to prevent vortex formation)

The flow-straightening vane is indispensable for the inlet conditions of the pump set. It prevents the development of a
submerged vortex (floor vortex) which could cause a drop in performance, for example. In addition, the floor and wall
surfaces of the intake chamber should be designed as a rough concrete surface. Rough surfaces minimise the
separation of boundary layers that may cause wall and floor vortices.

Flow-straightening vane and intake chamber


▪ The anti-vortex vanes in the bellmouth must be aligned
with the flow-straightening vane.

▪ The lifting lug is oriented in the same direction as the antivortex


vanes in the bellmouth.
Installation plan

Customer item no.:


Communication dated: Number: ES 8001054817
Doc. no.: Quick quote Item no.:100
Quantity: 1 Date: 23/03/2021
Page: 11 / 12

Amacan PA4 700-470/606UTG1 Version no.: 1

Loss diagram

Minimum fluid level diagram Minimum fluid level diagram


Open intake chamber Open intake chamber
(version without suction umbrella) (version with suction umbrella)

Supplementary drawing for losses diagramm and minimum water level


Installation plan

Customer item no.:


Communication dated: Number: ES 8001054817
Doc. no.: Quick quote Item no.:100
Quantity: 1 Date: 23/03/2021
Page: 12 / 12

Amacan PA4 700-470/606UTG1 Version no.: 1

DU Discharge tube, with discharge nozzle above floor and


open intake chamber

Calculation formulas:
H = Hgeo + ∆ Hv
∆ Hv
▪ Loss in the elbow hV Kr (see diagram)
▪ Loss in the riser (pipe friction)
▪ HV System (valves, etc. )
HV Systemmust be determined for the specific system.

You might also like