Professional Documents
Culture Documents
Standard Codes Reviewer
Standard Codes Reviewer
6 Unit area per person for waiting areas or standing rooms. 0.28 sqm.
Minimum spacing of rows of seats from back to back for a public assembly
10 0.83 mtr.
building.
13 Standard width of a seat without dividing arms for places of assembly. 60 cms.
15 Minimum headroom created by any projection from the ceiling. 2.00 mts.
17 Minimum dimension of landings in direction of travel for class A & B stairs. 112 cms.
19 Minimum height of a handrail above the upper surface of the tread. 76 cms.
28 Minimum width of a fire escape stair for existing stairs. 55.9 cms.
29 Minimum width of landing for a fire escape stair for existing stairs. 55.9 cms.
30 Minimum tread for a fire escape stair for small buildings. 15.25 cms.
31 Maximum rise of fire escape stair for a small building. 30.5 cms.
32 Maximum rise of fire escape stair for existing stairs. 22.9 cms.
33 Maximum height between landings for a fire escape stair for existing stairs. 3.66 mts.
34 Minimum headroom clearance for a fire escape stair for existing stairs. 2.13 mts.
35 Minimum headroom clearance for a fire escape stair for small buildings. 1.98 mts.
Maximum travel distance between room door intended as exit access and exit
39 30 mts.
with sprinkler system for institutional use.
Maximum travel distance from the door of any room to exit for hotels with
40 30 mts.
sprinkler.
Maximum travel distance from the main entrance door to exit for apartments with
41 31 mts.
sprinkler.
42 Minimum increase in width for an aisle per linear meter. 2.5 cms.
Minimum width of an aisle serving an occupant of 60 or more serving one side for
43 91 cms.
a public assembly building.
Minimum width of an aisle serving an occupant of 60 or more serving two sides
44 1.00 mtr.
for a public assembly building.
Minimum width of an aisle serving an occupant of below 60 for a public assembly
45 76 cms.
building.
Courtrooms with an occupant load of more than 100 are classified under what
53 Assembly
classification of occupancy.
Armories with an occupant load of more than 100 are classified under what
54 Assembly
classification of occupancy
Rooms where baled, bundled or piled materials segregated into desired sizes or
56 Picking rooms.
groups.
58 Buildings or structures used for the storage of explosives, shells, projectile, etc. Explosive magazine
61 Descriptive of any substance that ignites spontaneously when exposed to air. Phyrophoric
68 The temperature at which a liquid is transformed or converted into vapor. Boiling Point
The minimum temperature at which any material gives off vapor in sufficient
71 Flash Point
concentration to form an ignitable mixture with air.
A gas, fume or vapor used for the destruction or control of insects, fungi, vermin,
72 Fumigant
germs, rodents or other pests.
73 Minimum width of any driveway in and around a lumber yard / piles. 4.50 mts.
74 Minimum height of fence for a lumber yard for exterior storage of lumbers. 1.80 mts.
75 Maximum width of sumps for the retention of oil and petroleum products. 3.70 mts.
76 For Refineries, distilleries, and chemical plants, the minimum height for a fence. 1.50 mts.
Minimum travel distance from any individual room subject to occupancy by not
77 15.00 mts.
more 6 persons.
78 Maximum distance of travel from the high hazard area to an exit. 23.00 mts.
Minimum distance of an incinerator from any structure used other than a single
79 3.00 mts.
family dwelling.
88 Minimum stair width for a class B stair serving an occupant load of less than 50. 91 cms.
Length of a nosing or effective projection over the level immediately below it for
89 25 mm
tread below 25 cms in dimension.
91 A combustible liquid is any liquid having a flash point at or above. 37.8 oC (100 oF)
The time duration that a material or construction can withstand the effect of
92 Fire resistance rating
standard fire test is known as.
Any material which by its nature or as a result of its reaction with other elements
93 Cryogenic
produces a rapid drop in temperature of the immediate surrounding.
94 Classified as mercantile occupancies, the travel distance from exits shall be. 30.50 mts.
96 Under what classification of occupancy does home for the aged fall. Institutional
102 Minimum clear width of aisles for a Class 'A' store. 1.50 mts.
103 Minimum clear width of an exit access through a covered mall. 3.66 mts.
105 Standard inner radius of a curved stair in business occupancies. 763 cms.
108 Minimum width of stair for Class 'B' stairs serving more than 50 persons. 112 cms.
109 Minimum width of stair for Class 'B' stairs serving 50 persons and below. 91 cms.
111 Minimum width of a stair width for Class 'A' stairs. 25 mm.
112 Maximum height between landings for a Class 'B' stairs. 3.70 mts.
113 Minimum width of landings in direction of travel for Class 'A / B' stairs. 112 cms.
117 Maximum height between landings for Class 'A' ramp. No limit
118 Maximum height between landings for Class 'B' ramp. 3.66 mts.
120 Minimum width for fire escape for existing stairs. 55.9 cms.
Minimum horizontal dimension of any landing of platform for existing stairs for
121 55.9 cms.
fire escape.
122 Maximum rise for a fire escape for very small buildings. 30.5 cms.
123 Maximum height between landings for fire escape for existing stairs. 3.66 mts.
Class of fire involving ordinary combustible materials, such as wood, papers, cloth,
126 Class A
rubber, and plastics.
A tank, vat or container of flammable or combustible liquid in which articles or
127 materials are immersed for the purpose of coating, finishing, treating or similar Dip Tank
processes.
132 Under what classification of occupancy does town halls fall? Business
134 Minimum tread for a fire escape stair for existing stairs. 22.9 cms.
135 Maximum spacing of rungs for a fire escape ladder. 30.5 cms.
Class III combustible liquids shall mean any liquid having a flash point at how many
137 60 oC
degrees Celsius?
138 In standard seating, the minimum spacing from back to back. 0.83 mtr.
139 Minimum space from the back of chair to the front of the chair behind. 30 cms.
140 Maximum slope for aisles for public assembly structures. (1:8) 12.5%
141 Size of standpipe provided for each stage for public assembly building. 63.5 mm.
Where exterior corridors or balconies are provided as means of exit, they shall
143
open to the
76.25 mts.
144 outside and shall be spaced ___ meters apart. (Educational)
146 Maximum height from the floor for a rescue window for educational occupancies. 82 cms.
Minimum width of corridors, aisles, and ramps for exits in hospitals and nursing
147 2.44 mts.
homes.
Minimum width of corridors, aisles, and ramps for exits in residential-custodial
148 1.83 mts.
care.
Any room for sleeping in institutional occupancies if subdivided shall have a
149 465 sqm.
maximum area of how many square meters?
Includes buildings or groups of building under the same management in which
150 Hotel
there are more than 15 sleeping accommodations for hire.
Includes buildings containing three or more living units independent cooking and
151 bathroom facilities, whether designed as rowhouse, apartment house, tenement, Apartment Buildings
garden apartment, or by any other name.
152 Minimum number of stories of apartment buildings requiring fire alarm system. 3
CELLULOSE NITRATE/NITRO
155 Highly combustible/explosive cmpd. (nitric aid + cellulose)
CELLULOSE
COMBUSTIBLE, FLAMMABLE
157 Materials easily set on fire
OR INFLAMMABLE
158 Free burning fiber (cotton, oakum, hay, straw, etc.) COMBUSTIBLE FIBER
160 Liquid w/c causes fire when in contact w/ organic matter/chemicals CORROSIVE LIQUID
164 Raising temperature, cooling & condensing to produce a nearly purified substance DISTILLATION
166 Finely powdered substance when mixed w/ air and ignited will cause explosion. DUST
Extremely hot, luminous bridge formed by the passage of electric current across a
167 Electrical Arc
space between 2 conductors due to the incandescence of the conducting vapor
168 Hot piece or lump partially burned, still oxidizing w/o the manifestation of flames Ember
174 Portion of road/publicway kept opened/unobstructed for fire fighting units. Fire Lane
177 Minimum temperature a material gives off vapor to form ignition Flashpoint
182 Box/cabinet where fire hoses, valves and other equipment ware stored. Hose BOX
183 Cylindrical device where fire hose is wound and connected Hose Reel
Industrial process of heating materials to remove solvents/moisture, and fuse INDUSTRIAL BAKING &
185
certain salts to form uniform glazing on the surface of treated materials DRYING
186 Piece of metal or conductor used to bypass a safety in an electrical system JUMPER
187 Intended use/purpose of a building OCCUPANCY
Any person occupying/using a building (or portions) by virtue of lease
188 OCCUPANT
contract/permission with the owner/administrator
Type of burner where pressurized fuel is discharged to combustion chamber PRESSURIZED/FORCED DRAFT
193
which includes fans for introduction of air. BURNING EQUIPMENT
194 building/structure; 50 or more people congregate/gather/assemble PUBLIC ASSEMBLY BUILDING
195 street, alley, strip of land unobstructed from ground to sky intended for public use Public Way
Vertical pipes to which firehoses can be attached on each floor; includes system
201 STANDPIPE SYSTEM
where water is made available to outlets as needed.
202 Passage hall/antechamber between outlet doors and interior parts of building VESTIBULE
203 Vertical space/passage extending from floor to floor, base to top of the building VERTICAL SHAFT
Pipeline system filled with water and connected to a constant water supply for the
210 COMBINATION STANDPIPE
use of Fire Service and occupants of the building solely for suppression purposes.
213 pipes not filled with water; water is introduced thru Fire Service connections Dry Standpipe
Building, structure or facilities used for the storage of explosives, shells, projectile
214 EXPLOSIVE MAGAZINE
and ammunition
217 Time duration a material can withstand the effect of hundred fire test FIRE RESISTANCE RATING
A wall designed to prevent the spread of fire w/ fire resistance rating of not less
218 FireWall
than 4 hours and structurally stable.
219 Time w/c flame will spread over the surface of a burning material. Flame Spread Rating
Land covered with dry grass, cogon, reeds, brush and other highly combustible
221 HAZARDOUS FIRE AREA
growth that fires are likely to occur and hard to suppress.
Air compartment or chamber w/ one or more ducts are connected to form part of
228 plenum
an air distribution system.
229 density and volume of smoke developed within a certain period of time. SMOKE DEVELOPED RATING
min. horizontal dimension – not less than 2.00m / - inner courts shall be
234 Size & Dimensions of Courts
connected to a street or yard, or by a passageway – 1.20m min.
1. School Rooms – 3.00 cu.m w/ 1.00 sq.m of floor area per person Air Space Requirements in
237 2. Workshops, Factories, Offices – 12.00 cu.m of air space per person; Determining the Size of
3. Habitable rooms – 14.00 cu.m of air space per person. Rooms
– eaves over required windows not less than 750mm. minimum over from the side
238 & rear property lines / – sum of areas of openings must not exceed 50 % of sum of Location on Property
areas of walls
239 at least 10% of floor area (not provided w/ artificial ventilation system) Window Openings
a. Ventilation or vent shafts – horizontal cross-sectional area not < 0.10 sq.m per
240 meter height of shaft Vent Shafts
b. Air Ducts – 0.30 sq.m w/ at least dimension of 300mm
a. Footings – at least 2.40m below grade along national roads, may project not >
300mm beyond Property line. Projection into Alleys or
242
b. Foundations – not < 600mm below the grade, may encroach 500mm into public Streets
sidewalk areas
243 Min. of 3.00m above the established sidewalk grade Arcades
– not less than 2.40m above pavement or GL shall not, when fully opened, project
246 Doors & windows
beyond PL except fire exit doors
a. Public Street or alley less than 3.60m in width shall be truncated at the corner
“Chaflan”
247 Corner Bldgs. with Chaflans
b. If arcaded bldg, no chaflan reqtd notwithstanding the width of public street,
12.00m
1. Access – not < 600mm sq. or in diameter, min clear headroom of 800mm
2. Area Separation – enclosed attic space of combustible construction shall be Roof Construction and
253
divided into horizontal area max of 250 sq.m. area, 750 sq.m. in area for attic with Covering
Fire-extinguishing system.
1. Number of Exits
Above 1st storey – 10 occupant – 2 exits
Mezzanine – 185 sq.m area or more than 18m in dimension – 2 exits
500-999 – 3 exits
254 2. Exits – if only 2 exits required, shall be placed distance apart not < 1/5 of the
perimeter area.
3. Distance of Exits – w/o sprinkler – 45m from exterior exit door, w/ sprinkler
60m
4. Doors
a. Swing – exit door shall swing to exit travel in hazardous areas w/ 50 or more
occupant load
b. Double acting doors – view panel of not < 1,300 sq. cm.
c. Width and Height – not < 900mm in width, not < 2.00m in height, opening – 90
degrees and exit way clear width not < 700mm
5. Door Leaf Width – max of 1.20
6. Corridors and Exterior Exit Balconies
a. Width – not < 1.10m
b. Dead Ends – max 6.00m in length
7. Stairways
a. Width – serving an occupant load of more than 50 shall not be < 1.10m,
occupant load of 50 or less may be 90m (900mm) wide, private stairways serving
an occupant load of < 10 may be .75m (750mm)
b. Rise and Run. Rise – max 0.20m (200mm), Run - 0.25m (250mm)
c. Winding Stairways – narrower side of the thread 150mm – 300mm
d. Circular Stairways – used as exit w/ min width of run not < 250mm
e. Landings – straight run – max of 1.20m, vertical
f. Distance bet landings – max of 3.60m vertical distance landings.
g. Handrails – not < 800mm nor more than 900mm.
h. Stairway to Roof – if 4 or more storeys in height
i. Headroom – clearance 2.00m
8. Ramps – width – 1.10m min
9. Exit Outlets, Courts, Passageways
a. Slope – exit courts max of 1:10, exit passageway max of 1:8
b. Openings – on exit court not < 3.00m protected by fire assemblies not < ¾ hour
fire resistive. Except openings > 3.00m may be unprotected
c. Exit signs illumination – not < 10.7 lux at the floor level
10. Aisles
a. Width – not < 800mm if serving one side, not < 1m if serving both sides, side
aisles shall not < 1.10m
b. Exit Distance
1. Groups H, I occupancies w/o seats, line of travel to exit door by an aisle is not >
45.00m
2. Exit doors clear width 1.70m if 30 seats bet aisles and 1m distance of seat back
to back
c. Slope – max of 1:8
1. Every storey, basement or cellar w/ 200sq.m or more w/c is used for habitation,
etc. w/c has an occupant load of more than 20.2. Dressing, rehearsal rms.,
workshops or factories w/ occupant load of more than 10 or assembly halls w/
256 Fire-Extinguishing Systems
occupant load of more than 500, if the next doors of rooms are more than 30.00m
from safe dispersal area.3. Photographic x-ray, nitrocellulose films and
inflammable articles
1. Construction and Test – shall be wrought iron of GS w/ fittings, connections to
withstand 20 kg per sq.cm of water pressure
2. Size – 900 liters water per minute
3. Number Required – every bldg 4 or more storeys where any floor above 3rd
floor is 950m or less, equipped w/ 1 dry standpipe.
4. Siamese Connections:
b. Dry Standpipes – for bldgs.
257 2 way 100mm dry standpipe
w/ 4 or more storeys
3 way 125mm
4 way 150mm
Siamese inlet (located on street front) Not < 300mm nor more than 1.20m above
grade
5. Outlets – standpipe 63mm outlet not more than 1.20m above each floor level,
with 2 way standpipes 63mm outlet above the roof (all with gate valves)
1. Size – Interior wet standpipes deliver 190 liters/water per minute under 2.0 kg
per sq.cm water pressure
2. Outlets – 38mm valve each storey located not < 300mm nor more than 1.20m
above the floor.
258 c. Wet Standpipes
3. Water Supply – street main not < 100mm in diameter
4. Pressure and Gravity Tanks – 1500 liters/water per minute for not < 10 minutes
5. Fire pumps – capacity not < 1000 liters per minute w/ pressure not < 2 kg per
sq.cm connected to street main w/ not < 100mm diameter
1. Sheds, greenhouses, and the like not exceeding 6sq.m. in floor area
2. Addition of open terrace/patios not exceeding 20sq.m 2. Building Permits
259 3. Window Grilles (Exceptions)
4. Garden pools for water plants/aquarium not exceeding 500mm in depth. a. Minor Constructions:
5. Erection of garden walls other than walls not exceeding 1.80m
1. Width
1.1 Sidewalks of 2m w/ planting strip of 800mm in width separating curb &
sidewalk
1.2 Arcades shall be cantilevered from bldg. line, horizontal distance bet the curb
line & the outermost face of bldg not < 500mm
1.3 Combined open & arcaded sidewalks w/ planting strip not < 800mm in width
262 Arcades & Sidewalks
separating bet arcaded portion and open portion of sidewalk
2. Driveways, Entrances and Exits
2.1 Entrances and Exits of Building abutting sidewalks shall be made of either
ramps or steps
2.1.1 Steps shall have treads not < 300mm. Min no. of steps shall be (2), w/ risers
not exceeding 100mm
1.1. Primary Lines – min vertical clearance of 10m from the crown of road
1. Location of Poles and
pavement, 7.5m from the top of the shoulder/sidewalk
263 Clearances of Power Lines
1.2. Secondary Lines – min vertical clearance of 7.5m from the crown of road
along Public Roads.
pavement
2. Clearance of Supporting
a. Fire Hydrants – not < 5m
264 Structures such as Poles,
b. Curbs – not < 150mm from curb away from the roadway
Towers and others
a. Clearances Over Roof – Conductors have clearance not< 2.5m from highest pt.
265 3. Clearance of Service Drops
of roofs
4.1 New Building – load demand 200KVA or above provided w/transformer vault
4.2 Location – ventilated to outside air
4.3 Walls, Roof and Floor. Reinforced concrete not < 150mm, masonry/brick not Provisions for Transformer
266
less than 200mm, 300mm load bearing hollow concrete blocks. Inside wall and Vaults
roof surface constructed of HCB shall have a coating of cement/gypsum plaster
not < 20mm. Concrete floor not < 100mm thick.
5.1 Ventilation Openings
5.1.1. Size – not < .006sq.mm per KVA of transformer capacity in service, except
267 the net are shall not be < 0.1sqm for any capacity under 50KVA Ventilation Openings
5.1.2. Drainage – vaults w/ more than 100KVA transformer capacity shall be
provided w/ drain
6.1 Transformers Used w/ Capacitors – KVA rating shall not be < 135% of capacitor
268 Capacitors
rating
1.1 Hoistway pits clearance of not < 600mm remains bet the underside of car &
bottom of pit.
1.2 Min number of hoisting ropes shall be 3 for traction elevators and 2 for
drumtype elevators.
269 Elevators
1.3 Min diameter of hoisting & counterweight ropes shall be 30mm
1.4 Elevators w/ over-load relay and reverse polarity relay.
1.5 In high rise apts. or residential condos of more than 5 stories, at least 1
passenger elevator shall be kept on 24 hour constant service.
2.1 Angle of inclination shall not exceed 35 degrees from the horizontal
2.2 Width bet balustrades shall not be < 558 mm nor more than 1.20m. The width
270 Escalators
shall not exceed the width of the steps by more than 330mm.
2.3 Rated speed, not more than 38mpm.
3.1 Location
3.1.1 Main Bldg. is not made up of fire resistive materials, boilers shall be located
outside w/ distance not < 3.00m outside the wall of main bldg. & bldg. housing the
boiler
3.1.2 No part of the boiler shall be closer than 1m from any wall
3.2 Smokestacks - shall able to withstand a wind load of 175km per hour & shall
rise at least 5m above the eaves of any bldg. w/in a radius of 50m.
271 Boilers & pressure Vessels
3.3 Boilers more than 46sq.m. heating surface shall be provided w/ 2 means of
feeding water, 1 steam driven and 1 electrically driven, 1 pump and 1 injector.
3.4 2 check valves shall be provided bet any feed pump and boiler
3.5 Boilers rms. shall have at least 2 separate exits.
3.6 Each boiler shall at least 1 safety valve. Having more than 46.sq.m pressure of
water heating surface/generating capacity exceeding 97kg. per hour, 2 or more
safety valves are required.
4.1 68-74 degrees F temperature and humidity for comfortable cooling, 4.57 to
7.60 MPM temperature at an air movement.
4.2 Not more than 136kgs of refrigerant shall be stored in a machine rm.
4.3 Where ammonia is used into a tank of water at least 1 gallon of water shall be Refrigeration and Air
272
provided for every .04536kg of ammonia in the system. Conditioning
4.4 Refrigerant piping crossing a passageway in any bldg. shall not < 2.3m above
the floor.
4.5 Window type AC (Air Con) shall not be < 2.13m from the ground
5.1 To maintain water pressure in all floors of a bldg./structure, the ff. systems
may be used:
273 5.1.1 Overhead tank supply – may be installed above the roof w/ a vent and an 5. Water pumping for
overflow pipe leading to a storm drain and be fully covered. Bldg./Structures
5.1.2 Pneumatic Tank – unfired pressure vessel
6.1 Piping 100mm in diameter and above shall be flanged. Small diameter pipes –
may be screwed6.2 Color coding of Piping:Steam Division High Pressure – White
Exhaust System – BuffWater Division Fresh Water, low pressure - Blue Fresh
274 Water, high pressure - Blue Salt water piping – GreenOil Division Delivery – Brass Pipings
or Bronze Discharge – YellowPneumatic Division All piping GrayGas Division All
piping – BlackFuel Oil Division All piping – BlackRefrigerating Division Pipes – Black
Fittings - Black
275 erected @ sidewalks/walkways not < 2.40m in height above curb line. Fence
277 G.I wire gauge 16,38mm mesh nylon net; canvas 5. Protective Nets/Screen
6.1 Temporary walkway adjacent to the street line not more than 1.20m wide (for
the use of pedestrians). Where the road right of way is 5m or less, no temporary
walkway shall be allowed
278 6.2 Width of walkway shall not < 1.20m but more than 1/3 the width of the 6. Walkways & Railings
sidewalk.
6.3 Walkways capable of supporting uniform live load of 650kg per sq.m.
6.4 Railings – not < 1m in height
7.1 Every Trench, 1.50m or more in depth, provided w/ means of exit at least 7.50
279 7. Precautionary Measures
of its length
10.1 Where more than 200 workers are employed, a properly first-aid room shall
282 10. Sanitation & First Aid
be provided w/ a physician/nurse.
11.1 Passageways, stairways and corridors – average light intensity not < 2 foot
283 candles. 11. Temporary Light & Power
11.2 Locations where tools & or machinery are used – 5 foot candles.
284 shall be screened/protected on all sides not < 1.80m height 12. Hoist Towers
16.1 Used as hoistways/elevator shaftways be protected all sides, expect the side
used for loading & unloading. Protection shall be in barricades not < 1.20m high
288 Floor Openings
near the edges of openings, guard rails not < 910mm high placed not < 600mm.
16.2 Solid barriers not < 910mm high
17.1 Guard Rails - Top rail not < 910mm high above the platform level. An
intermediate rail shall be provided bet the top rail & the platform. Guard rails
shall have supports not more than 2.40m apart, shall be constructed to withstand
289 a horizontal force of 30kgs. per meter 17. Guard Rails & Toe Boards
17.2 Toe Boards – shall extend not < 150mm above the platform level. Toe Boards
of Wood shall not < 25mm nominal thickness w/ supports not more than 1.20m
apart, Metal shall not < 3.175mm thick w/ supports not more than 1.20m apart.
18.1 Chutes for removal of materials & debris shall be provided in demolition
operations w/ are more than 6m above pt. of material to be removed
18.2 Intervals of 7.60m or less w/ substantial stops to prevent descending matl’s
18.3 Chutes w/c at an angle 45 degrees from the horizontal be enclosed on all 4
sides
290 18. Chutes
18.4 Chutes w/c at an angle 45 degrees from the horizontal may be left open on
the upper side
18.5 Openings into matl’s/debris are dumped are dumped at the top of a chute
shall be protect by a substantial guardrail extending @ least 1.90m above the level
of the floor
unoccupied space bet bldg. lines & lot lines other than yard: free, open and
unobstructed from the ground upward.
a. Inner court – bounded on all sides/around its periphery by bldg. lines.
b. Open court – bounded by 3 sides by bldg. lines w/ 1 side bounded by another
open space
c. Through court – bounded on 2 opposite sides by bldg. lines w/ the other
292 opposite sides bounded by other open space. Courts
• Every court shall have a width not < 2.00m for 1 and 2 storey bldgs. This may
reduced to not < 1.50m in cluster living units (quadruplexes, rowhouses) for 1 or 2
storeys in height w/ adjacent courts w/ area not < 3.00m. Irregularly shaped lots
like triangular shall be < 3.00m
• Bldgs more than 2 storeys in height, min width of the court shall be increased at
the rate of 300mm
Yards for Commercial, Industrial, Institutional & Recreational Buildings
ROAD RIGHT OF WAY FRONT SIDE REAR
30M & above 10m 3m
293 25-29m 8m 3m
20-24m 6m
10-19m 4m 2m
Below 10m 2m
2.1 Mixed occupancies, parking requirements shall be the sum of 100% dominant
2. Parking Requirement
294 use & 50% of each of the non-dominant
Computation:
2.2 20% of parking requirements may be provided w/in premises
2.40x5.00m perpendicular or
295 Average automobile parking size diagonal, 2.00x6.00m for
parallel
1.2 Low Income Single Detached living units in housing project areas w/ individual
lots not more than 100sq.m Pooled parking at 1 slot/10 living units1.3 Multi family
units w/ unit floor of: a. Up to 50sq.m 1 slot/8 living units b. Above 50sq.m to
100sq.m 1 slot/4 living units c. More than 100sq.m 1 slot/living unit1.4 Hotels 1
slot/10 rooms1.5 Residential Hotels & Apartels 1 slot/5 rooms1.6 Motels 1
slot/unit1.7 Neighborhood shopping center 1 slot/100 sq.m of shopping floor
area1.8 Markets 1 slot/150 sq.m of shopping floor area1.9 Restaurants, fast-food
centers, bars and beerhouses 1 slot/30 sq.m of customer area1.10 Nightclubs,
supperclubs and theater-restaurants 1 slot/20 sq.m of customer area1.11 Office
Bldgs 1 slot/125 sq.m of gross floor area1.12 Pension/Boarding/Lodging houses 1 Parking & Loading Space
297
slot/20 beds1.13 Other Bldgs in Business/Commercial Zones 1 slot/125 sq.m of Requirements
gross floor area 1.14 Public assembly bldgs such as theaters, cinemas, etc. 1
slot/50 sq.m spectator area1.15 Places of Worship & Funeral Parlors 1 slot/50
sq.m of congregation area1.16 Schools Elementary, Secondary, Vocational & Trade
schools 1 slot/10 classrooms College & Univ. 1 slot/5 classrooms1.17 Hospitals 1
slot/25 beds1.18 Recreational Facilities Bowling Alleys 1 slot/4 alleys Amusement
Centers 1 slot/50 sq.m of gross floor area Clubhouses, beach houses and the like 1
slot/100 sq.m of gross floor area1.19 Factories, manufacturing establishments,
mercantile bldgs, warehouses and storage bins 1 car slot/1,000 sq.m of gloss floor
area1.20 Tourist bus parking areas 2 bus slots/hotel or theater restaurant
1. A Filipino citizen and Good Moral Character
2. Duly registered Architect or Civil Engineer QUALIFICATIONS OF
298
3. Member of Accredited organization of not less than 2 years BUILDING OFFICIAL
4. At least 5 years diversified experience in building design and construction
1. Public Buildings
2. Traditional Indigenous Family
299 Exemptions of Bldg. Permit
Dwellings – native materials
Cost doesn’t exceed P15,000
303 Minimum spacing for seats in a chair type measurement from back to back. 0.85 mtr.
306 In standard seating, the minimum spacing of rows measured from back to back. 0.84 mtr.
308 Minimum area of a double acting door view panel. 1,300 sqmm / 1.30 sqm.
Minimum number of exit for floors above the first storey having an occupant load
312 2
of more than 10
315 Maximum floor area for an attic made of combustible materials. 250.00 sqm
316 Maximum center to center spacing of a draft curtain sprinkler. 1.80 mts.
317 Maximum floor area for an attic made of incombustible materials. 750.00 sqm.
324 Minimum air space between walls of a masonry chimney above the roof. 2" / 50 mm
326 Maximum rise of one row of seat to the next. 400 mm / 0.40 mtr.
Minimum number of exit for stands within a building serving an occupant load of
327 3
300.
328 Minimum height of a guard rail located in front of the grandstand. 0.90 mtr
330 Minimum spacing for seats with backrests measured from back to back. 0.75 mtr.
331 Minimum spacing for seats without backrests measured from back to back. 0.60 mtr.
332 Minimum width of an exit door in an aisle. 1.70 mts.
336 Minimum width of an aisle serving only one side. 800 mm / 0.80 mtr.
337 Open space requirement for an interior lot. 50% of lot area
338 Open space requirement for a corner lot or a through lot. 10% of lot area
339 Bounded on all sides or around its periphery by building lines. Inner court
344 Air space requirement for a school room per person. 3.00 cum.
345 Air space requirement for a habitable room per person. 14.00 cum.
346 Minimum area of opening of an air duct. 300 sqmm / 0.30 sqm
Maximum projection beyond the property line of a footing along the national road
347 300 mm
and at least 2.40 mts. In depth.
348 Minimum clearance of a canopy or a marquee from the sidewalk. 3.00 mts.
349 Minimum stair width for occupant load of less than 50. 0.90 mtr.
350 Minimum width of a temporary walkway. 1.20 mts.
352 Vacant space left between the building and lot lines less than 2.00 mts in width. Setback
354 Minimum width of a passageway connecting a street and a court. 1.20 mts.
355 Standard air space requirement per person for factories. 12.00 cum.
357 Air supply per person per minute for auditoriums. 0.30 cum
Minimum horizontal clearance of the curb line to the outermost edge of the
360 300 mm
marquee.
361 Minimum clearance of the lowest portion of an awning to the ground. 2.40 mts.
363 Minimum live load bearing capacity of a construction canopy. 600 kgs./sqm.
365 Minimum wind load capacity for roofs for vertical projection. 120 kgs./sqm.
366 Maximum height of a handrail above the stair thread. 0.90 mtr.
367 Minimum ceiling height for naturally ventilated rooms. 2.70 mts.
368 Minimum height of a handrail above the stair thread. 0.80 mtr.
Maximum distance of any portion of a building from the nozzle of a 23 mts fire
375 6.00 mts.
hose.
377 Minimum extension of a proscenium wall above the roof. 1.20 mts.
385 Minimum distance of a sign from any electrical post or telephone wires. 1.00 mtr.
386 Minimum open space requirement for a corner lot. 10% of lot area
388 Maximum slope for an entrance or exit ramp. One is to ten (1:10)
391 Office building parking ratio. 1:125 sqm. Of gross floor area
395 Maximum distance of a handicapped parking from the facility being served. 60.00 mts.
397 Theaters, cinemas, auditoria, and stadia parking ratio. 1:50 sqm. Of spectators' area
Minimum number of wheelchair seating space for 51-300 seating capacity for
398 4
auditoriums.
401 Maximum distance of an accessible elevator from the entrance of a building. 30.00 mts.
402 Minimum height of signs on walls and doors for the disabled to see comfortable. 1.40 mts.
405 Maximum height of signs on walls and doors for the disabled to see comfortably. 1.60 mts.
406 Minimum width of a parking slot for the disabled. 3.70 mts.
Minimum ceiling height from 3rd floor to succeeding floors with artificial
408 2.10 mts.
ventilation.
Maximum width reduced by handrails and doors fully opened to balconies and
414 200 mm
corridors
415 Minimum width of stairs serving more than 50 occupants. 1.10 mts.
417 Maximum reduction in width of a stair due to trims and handrails. 100 mm
423 Maximum number of seats between the wall and the aisle. 7
Maximum distance between the back of each seat to the front of the seat behind
424 300 mm
it.
426 Maximum projection of a penthouse or other projections above the roof. 8.40 mts
427 Maximum ratio of a penthouse area to that of the supporting roof. one third (1/3)
429 Minimum thickness of rubble stone masonry chimney for residentials. 300 mm
432 minimum thickness of front and side smoke chamber walls. 200 mm
433 Minimum number of storeys requiring one (1) or more dry standpipes. 4
434 Minimum volume of water a dry standpipe should provide. 900 liters/minute
435 Diameter of a dry standpipe requiring a two-way Siamese connection. 4" (100mm)
436 Diameter of a dry standpipe requiring a three-way Siamese connection. 5" (125mm)
437 Diameter of a dry standpipe requiring a four-way Siamese connection. 6" (150mm)
438 Minimum volume of water an interior wet standpipe should provide. 190 liters/minute
442 Maximum distance of a hose nozzle to any portion of a building. 6.00 mts.
444 Maximum projection into a sidewalk of a sign 4.50 mts. above grade. 1.00 mtr.
445 Minimum vertical clearance from the bottom of a signage to an arcaded sidewalk. 5.00 mts.
447 Number of days of work abandonment of stoppage for a building permit to expire. 120 days
448 Width of planting strip for sidewalks 2.00 mts in width. 0.80 mtr.
449 Minimum horizontal distance of the curb line to the outermost face of an arcade. 500 mm
452 Slope of driveway to sidewalk where the height of curb is 200 mm and above. One is to Eight (1:8)
Minimum vertical clearance of primary lines from the crown of the pavement
453 10.00 mts.
when crossing the highway.
Minimum vertical clearance of primary lines from top of sidewalk when installed
454 7.5 mts.
along the side of the highway.
455 Vertical clearance of secondary lines from sidewalks along or crossing the street. 7.5 mts.
456 Minimum clearance of conductors from the highest point of a roof. 2.50 mts.
461 Vertical clearance of a service drop communication line when crossing a street. 5.50 mts.
466 Unit area per occupant for offices and garages. 9.30 sqm.
467 Unit area per occupant for class rooms. 1.80 sqm.
468 Unit area per occupant for stores - retail sales rooms upper floors. 5.60 sqm.
469 Unit area per occupant for nurseries for children. 3.25 sqm.
470 Unit area for stores -retail sales room for basement and ground floor. 2.80 sqm.
472 Unit area per occupant for aircraft hangars without repairs. 46.50 sqm.
473 Unit area per occupant for warehouses and mechanical equipment room. 28.00 sqm.
474 Unit area per occupant for theaters and the like. 0.65 sqm.
477 Parking requirement for multi family living unit of 50 sqm floor area. 1slot/8 units
478 Parking requirement for multi family living unit above 100 sqm floor area. 1 slot/unit
479 Parking requirement for multi family living unit for 50-100 sqm floor area. 1 slot/4 units
482 Minimum parking requirement for the handicapped. 1 slot/50 parking slots
484 Parking requirement for elementary, secondary, and vocational schools. 1 slot/10 classrooms
490 Maximum distance of handicapped parking from the structure served. 60.00 mts.
492 Maximum height of a water closet from the floor. 0.50 mts.
496 Least dimension for a parking slot for the disabled. 3.70 mts.
One or more habitable rooms which are occupied or which are intended or
500 designated to be occupied by one family with facilities for cooking , sleeping, Dwelling unit
living, and eating.
That portion of the foundation of a structure which spreads and transmits loads
501 Footing
directly to the ground or soil.
A room or suite of two or more rooms, designed and intended for , or occupied by
503 Apartment
one family for living, sleeping, eating, and cooking purposes.
A stationary open hearth or brazier, either fuel-fired or electric, used for food
504 Barbecue
preparation.
A portion of the seating space of an assembly room, the lowest part of which is
505 Balcony
raised 1.20 mts or more above the level of the main floor.
506 The pipe which connects a flue-burning appliance to a chimney. Chimney connector
A hearth and fire chamber or similarly prepared place in which a fire may be made
507 Fireplace
and which is built in conjunction with a chimney.
A horizontal structural piece which supports the end of the floor beams or joists or
508 Girder
walls over opening.
513 The unit area per occupant for hotels. 18.60 sqm.
514 The unit area per occupant for dining establishments. 1.40 sqm.
515 The unit area per occupant for theaters. 0.65 sqm.
518 Offices shall be provided how many cubic meters of air per person? 12.00 cum.
Multiple living units of up to 6 units built on the same lot shall have an access road
519 3.00 mts.
directly connecting said building to a public street a width of.
Sidewalks of 2 mts or more in width shall include on its outer side a planting strip
520 800 mm / 0.80 mtr.
of not less than how many millimeters in width?
Arcades shall be cantilevered from the building line over the sidewalk and the
521 horizontal clearance between the curb line and the outermost face of any part of 500 mm
the arcade shall not be less than.
522 Printing plants shall be classified under what type of occupancy. Business and mercantile
523 Power plants shall be classified under what type of occupancy. Industrial
525 Repair garages shall be classified under what type of occupancy. Storage and hazardous
527 Turnabout should also be provided at or whithin how many meters of dead end. 3.50 mts.
Under B.P. 344, a level area of not less than how many meters shall be provided at
529 1.80 mts.
the
530 top and bottom of any ramp.
531 Under what classification of occupancy does Mental Hospitals fall? Institutional
533 Under what classification of occupancy does Aircraft hagars fall? Business and mercantile
534 Under what classification of occupancy does cold storage and creameris fall? Industrial
535 Under what classification of occupancy does private garage fall? Accessory
536 Minimum loading slot requirement for Hospitals and hotels. 1 truck loading slot
537 Minimum travel distance from handicapped parking to facility being served. 60 mts.
Percentage required for number of parking if parking garages are available within
538 20%
200 meters of structure.
539 Parking requirement for amusement centers. 1/50 sqm of gross floor area
Parking requirement for multi-family living units of more than 100 sqm of living
542 1/living unit
unit area.
544 Parking requirement for places of worhip. 1/50 sqm of congregation are
Maximum projection of a balcony over a street of over 3 meters but not more
545 0.60 mtr.
than 6 mts.
Maximum height of 1st the floor for a 2-story wood structure with a height of 7
547 4.50 mts.
mts.
548 Maximum spacing of posts for 2-story wooden structure with a height of 8 mts. 4.50 mts.
549 Under what classification of occupancy does fences of over 1.80 mts in height fall? Accessory
550 Under what classification of occupancy does Aircraft repair hangars fall? Storage and hazardous
552 Under what classification of occupancy does wood working establishements fall? Storage and hazardous
553 Under what classification of occupancy does police and fire stations fall? Business and mercantile
How many meters above the floor is the comfortable reach of persons confined to
556 0.70 - 1.20 mts.
a wheelchair.
How many meterd is the comfortable clearance for knee and leg space under
557 0.74 mts.
tables for wheelchair users.
A raised rim of concrete, stone or metal which forms the edge of street, sidewalk,
562 Curb
etc.
The purpose of the NBC is to provide for all buildings and structures, a framework
563 of minimum
standards and requirements which is the
564 Under the NBC abutment on lot lines are allowed only in . Fire zones
Under the NBC, every corridor and exterior exit balcony servings as a required exit
565 for 1.20 mts
an occupant load of more than ten width shall not be less than
566 Under the NBC, the vertical distance between landings shall not be more than 3.60 mts
567 Under the NBC, open spaces for corners and through lots is a. 10%
569 Under the NBC, space required for interior lots is 50%
Under the NBC, the minimum dimension for court or near yard from the property
570 line 2.00 mts
to the face of the building is
Under the NBC, a building in R-1 zone shall comply with the open space
571 requirement 5.00 mts
in the form of
Under the NBC, clearance between established grade of the street and/ or
572 sidewalk 3.00 mts
and the lowest under surface of any part of the balcony shall not less than
Under the NBC, the interior lots shall have an access road with a minimum width
573 3.00 mts
of
Under the NBC, gasoline filling and service stations shall classified under what
574 business & mercantile
occupancy classification?
Under the NBC, display windows or wall signs within how many meters above the
575 3.00 mts
sidewalk
Under the NBC, areas where adequate parking lots/ multi-floor parking garages
are
576 available within 200 mts. of the proposed building / structures only what 20%
percent of
the parking requirements maybe provided within the premises?
Under the NBC, general units of measurement on consonance with the current
577 System International
worldwide practice follow the
578 Under the NBC, the minimum requirements for a parking space is 750 mm
579 Under the NBC, for Group A Dwellings, stairs shall have a clear width of at least 2.50x5.00
Under the NBC, mezzanine floors shall have a clear ceiling height not less than
580 how 1.80 mts
many?
581 Under the NBC, hospitals shall have one parking slot for every how many beds? 25
Under the NBC, all inner courts shall be connected to a street or yard either by a
582 pass 2.00 mts
with a minimum width of
Under the NBC, a dwelling shall occupy not more than how many percent of an
583 80%
inside non-corner single frontage lot?
584 Under the NBC, prisons shall be classified under what occupancy classification institutional
Under the NBC, cold storage shall be classified under what occupancy
585 storage& mercantile
classification?
Under the NBC, factories using not highly combustible materials shall be classified
586 industrial
under occupancy classification?
Under the NBC, window openings shall equal to at least of what percent of the
587 floor 10%
area of room?
Under the NBC, parking areas for the physically handicapped shall be within how
588 6.00 mts.
many meters in length?
Under the NBC, of only two exits are required, they shall be placed a distance
589 apart 1/5.
of not less than what fraction of?
Under the NBC, habitable rooms with natural ventilation shall have a minimum air
590 14 cu. mts.
space per person of
591 Under the NBC, the unit area per occupant of offices is 9.3 m2
Under the NBC, a mezzanine floor use other than for storage purposes shall have
592 at 185 sm.
least two stairways to an adjacent floor is the area greater than?
Under the NBC, residential hotels and apartels shall be provided with one parking
593 slot 5 units
for every how many units?
594 Under the NBC, for Group A Dwellings, stairs shall have 750 mm
595 Under the NBC, rooms for human habitation shall have a minimum size of 6 m2
Under the NBC, repair garages shall be classified under what occupancy
597 storage & hazardous
classification?
Under the NBC, power plants shall be classified under what occupancy
599 storage & hazardous
classification?
Under the NBC, printing plants shall be classified under what occupancy
600
classification?
Under the NBC, multiple living units of up to six units built on the same lot shall
601 3.00 mts.
have an access road directly connecting said building to a public street a width of
Under the NBC, offices shall provide how many cubic meters of air space per
602 12 cu. mts.
person?
Under the NBC, front yards for commercial buildings abutting a road right-of-
603 width 8 mts.
of 25-29 m shall be
Under the NBC, a building permit shall expire if work authorized is abandoned or
604 120 days
suspended at any time after commencement or a period of
605 Under the NBC, the unit area per occupants of theaters is 65 m2
606 Under the NBC, the unit area per occupant of dining establishments is 1.4 m2
607 Under the NBC, the unit area per occupant of hotels is 18.6 m2
Under the NBC, the fire station shall be classified under what occupancy
608 business & mercantile
classification?
Under the NBC, monasteries shall be classified under what occupancy residential, hotels &
609
classification? apartments
Under the NBC, air craft repair hangers shall be classified under what occupancy
610 storage & hazardous
classification?
Under the NBC, in mixed occupancies the parking requirements shall be the sum
611 of 50%
100% of the dominant use and what percent of the dominant uses?
Under the NBC, habitable rooms provided with artificial ventilation for buildings of
612 2.40 mts.
more than one-storey shall have a minimum ceiling height of the first storey at
Under the NBC, multiple living units of 16 to 25 units built on the same lot shall
613 have 3.00 mts.
an access road directly connecting said buildings to a public street a width of
Under the NBC, the entry ramp of the driveway connecting the roadway surface to
614 1/3 to ¼
the sidewalk shall have a slope ranging from
Under the NBC, every room intended for any use and not provided with artificial
615 ventilation system shall be provided with a window with a total free area of 10%
opening equal to at least how many percent of the floor area of the room?
616 Under the NBC, for Group A Dwellings, stairs shall have a minimum run of 200 mm.
617 Under the NBC, the unit area per occupant of laboratories is 4.6 m2
618 Under the NBC, the unit area per occupant of apartment is 28 sm.
Under the NBC, the term that shall mean the total number of persons that may
619 occupant load
occupy a building or a portion thereof at any one time is
620 Accessible parking should have a minimum width of _________ 3.70 mts.
Perpendicular and diagonal parking for average auto mobile should have a
621 2.50m x 5.00m
minimum _________
622 Parallel parking for average auto mobile should have a minimum __________ 2.15m x 6.00m
623 Jeepney / shuttle parking slot should have a minimum __________ 3.00m x 9.00m
624 Standard truck / bus parking slot must have a minimum __________ 3.60m x 12.00m
625 An articulated truck slot must be computed at a minimum of __________ 3.60m x 18.00m
628 What is the minimum requirement for Total Open Spaces for Through Lot? 10% open space
629 What is the minimum requirement for Total Open Spaces for Corner Lot? 10% open space
Mezzanine floor shall have a clear ceiling height not less than ________ above and
630 1.80m
below it.
632 What is the least dimension for Room (Human Habitations)? 2.00m
633 What is the minimum requirement for Total Open Spaces for Inside Lot? 20% open space
634 What is the minimum requirement for Total Open Spaces for End Lot? 50% open space
Habitable rooms provided with artificial ventilation shall have ceiling height not
636 2.40m
less than __________ measured from the floor to ceiling.
637 What is the minimum dimension for Accessible Elevator? 1.10m x 1.40m
Accessible elevator should be located not more than __________ from the
638 30 m.
entrance and should be easy to locate with the aid of signs.
639 Accessible water closet stalls shall have a minimum dimension of __________. 1.70m x 1.80m
Passenger train shall have at least __________ designated seats for disabled
640 6
person.
A bar which extends across at least ½ the width of each door leaf, which will open
642 Panic hardware
the door if subjected to pressure.
Who shall be the responsible for carrying out the provision of the Building Code as
645 Building Officials
well as the enforcement of orders?
646 A court bounded on all sides or around its periphery by building lines. Inner court
The fully enclosed component of the building / structure situated between the
648 establishment grade and the first of a typical floor of the building / structure’s Podium
tower component.
A portion of a yard for which the permitted limit of paving / hardscaping shall not
652 Courtyard
exceed 50% of the area of the yard.
The angle of inclination of an escalator shall not exceed __________ form the
655 30 degree
horizontal.
The rate and speed, measured along the angle of inclination, shall be not more
656 38 m./min.
than __________ meters per minute.
Hoistway pit for elevators shall be of such depth that when the car rest on the
658 fully compressed buffers, a clearance of not less than __________ remains 600 mm.
between the underside of the car and the bottom of the pit.
659 How many storey shall a dry stand pipe be equipped with it? 4 Storey
. What is the maximum total projection of balcony if the width of the streets are
660 1.50m
over 14.00 meters
662 What is the minimum road right-of-way width to be able to construct a basement? 10.00m
What is the minimum width of planting strip (for glass and shrubs) for each side of
664 200mm
the RROW?
Sidewalks of 2.00 meters or more width shall include on its outer side a planting
665 800mm
strip of not less than _________ in width.
667 Escalators width shall not exceed the width of the steps by more than __________ 330 mm
670 What is the minimum setback for residential-1? 4.50 x 2.00 x 2.00
What is the minimum setback for Commercial buildings if the RROW is 30.00m
671 8.00 x 5.00 x 5.00m
and above?
What is the minimum width of planting strip (for trees) for each side of the
672 300mm
RROW?
673 What is the minimum Total Open Space for Corner-through lot? . 5% open space
674 What is the minimum Total Open Space for Interior Lot? 50% open space
Roof – The wind load for roof shall be atleast __________ kg/m2 for vertical
675 120
projection.
Footing shall be of sufficient size and strength to support the load of the dwelling
676 and shall be at least __________ thick and __________ below the surface of the 250mm & 600mm
ground.
What is the required distance of ingress / egress of vehicles for commercial lot
677 50.00m
near major intersections?
A building permit issued under the provision of the Building Code shall expire and
679 become null and void if the building or work authorized therein is not commenced 12 months
within a period of _________
681 What is the Air Space requirement for a Habitable Rooms? 14.00m3
Any portion of building above the first floor projecting over the sidewalk beyond
682 Arcade
the first-storey wall used as protection for pedestrians against rain or sun.
That portion of the foundation of a structure which spreads and transmits loads
683 Footing
directly to the soil or the pile.
All the portions of the building or structure below the footing, the earth upon
684 Foundation
which the structure rests.
A horizontal structural piece which supports the end of the floor beams or joist or
685 Girder
walls over opening.
687 A corridor or passageway used in common by all the occupants within a building. Common Hall
The beam or girder placed over an opening in a wall, which supports the wall
688 Lintel
construction above.
A Lodging House is any building or portion thereof, containing not more than
689 5
__________ guest rooms where rent is paid in money, goods, labor, or otherwise.
690 The wall between the bottom of the window sill and the ground. Masonry Socalo
692 . A wall which supports any load other than its own weight. Bearing Wall
What is the Wheelchair Seating Capacity for an Auditoriums that has 51 -300
694 4
seating capacity?
698 All doors should have a minimum clear width of __________ 0.80 m.
Dropped curbs shall be sloped toward the road with a maximum gradient of
701 1:20
__________ to prevent water from collecting at the walkway.
703 Curb cut-outs should not have a gradient not more than __________ 1:12
704 What is the minimum dimension for Rest Stops on busy or lengthy walkways? 12.00m
Ramps shall be equipped with curbs on both side with a minimum height of
706 0.10 m
__________
The railing should incorporate a tapping rail to assist the blind; this should not be
707 0.35 m
greater than __________ above the adjacent surface.
Blighted Area; Eyesore; An area where the value of real estate tend to deteriorate
708 because of the dilapidated, obsolescent, and insanitary condition of the building Slum
within the area.
Entrance with vestibules shall be provided a level area with at least a __________
710 1.80m
depth and a 1.50m width.
The length of ramp should not exceed __________ if the gradient is 1:12, and shall
711 6.00m
provided with landing not less than 1.50m
712 What is the incremental setback per storey above the second floor level? 0.30m
713 Arcade pedestrian walkways shall have a clear height of __________ 3.00m
All pipe materials to be used in buildings/ structures shall conform to the standard
714 Bureau of Product Standards
specification of the __________ of the Department of Trade and Industry.
715 The live load at first floor shall be at least __________ kg/m2 200 kg/m2
716 The live load for the second floor shall be at least __________ kg/m2 150 kg/m2
Multi-floor parking garages may serve the 20% parking requirements of the
717 200
building / structure within __________ meter radius.
What is the minimum required parking slot for offices, commercial or mixed-use
718 1 car : 2 units
condominium buildings / structures if the unit gross area is 18 – 40 m2?
In BP 344, Handrails that required full grip should have a minimum dimension of
719 30 cm.
__________cm – 50 cm
In BP 344, The lowest point of a dropped curb should not exceed _________
720 25 mm.
height above the road or gutter.
721 Which does the building code regulate and control? Construction
Which is not part of the general powers and functions of the secretary of the
formulate guidelines on land-
722 Public Works, Transportation and Communication pertinent to the National
use planning and zoning
Building Code?
723 Who is responsible in carrying out the provisions of the National Building Code? Building Officials
What are the two cases which invalidates the building permit. I - when
construction does not commence with in one year from the date of its issue; II -
724 when construction is suspended for more than one year; III - when construction is I & IV
suspended for six months; IV - when construction is suspended or abandoned for
a period of 120 days :::
Which is a reason or ground for non-issuance, suspension or revocation of a errors found in plans and
725
building permit? specifications
726 What document is necessary in order to legally occupy a building? certificate of occupancy
727 Where is the measurement of site occupancy taken? gross floor area
728 Which is not a determinant in the limitation of maximum site occupancy? Use
729 What is the minimum height of ceilings for spaces that are naturally ventilated 2.7 m.
What is the minimum head room clearance for the third floor that is artificially
730 2.10 m.
ventilated?
731 The minimum window area for a 12 square meter naturally ventilated room. 1.2 m2
733 In order to positively drain a sidewalk, its slope shall be about ___. 1:50
Any new construction which increases the height or area of an existing building or
735 Addition
structure.
Which office issue certificate of height clearance for buildings located within
740 Air Trans. Office
approach and departure zones of airports?
741 Which is not required in applying for a building permit? Bussiness Permit
742 Which is the most important basic need of human settlement? Water
743 What is the minimum slope for accessible ramps for disabled? 1:12
Is a set of rules that specify the minimum acceptable level of safety for
744 constructed objects such as buildings and Building Codes
nonbuilding structures.
Under PD 1096 the executive officer of OBO appointed by the sectary to enforce
745 the provision of the code in the field Building official
as well as the enforcement or orders and decisions made pursuant thereto.
This wall is sometimes constructed over the center of the property line dividing
two terraced flats or row houses so
746 Party Walls
that one half of the wall is on each property. They are sometimes two abutting
walls built at different times.
751 Required number of water closets for females for an auditorium serving 16-35. 3
758 Ratio of water closets for female population for PrincipalWorship Places. 1:75
A key house agency that assist private developers to undertake Home Insurance & Guarantee
766
low and middle income mass housing production Corporation (HIGC)
770 BP 220: The parking requirement for multi-family dwelling is 1 slot/family dwelling
775 Maximum stair rise height for a class A stair. 0.19 mtr.
776 Maximum height between landings for class A stair. 2.75 mts.
778 Unit area per person for waiting areas or standing rooms. 0.28 sqm.
780 Travel distance to an exit without fire sprinkler system. 46.00 mts.
781 Travel distance to an exit with fire sprinkler system. 61.00 mts.
Minimum spacing of rows of seats from back to back for a public assembly
782 0.83 mtr.
building.
785 Standard width of a seat without dividing arms for places of assembly. 60 cms.
789 Minimum dimension of landings in direction of travel for class A & B stairs. 112 cms.
791 Minimum height of a handrail above the upper surface of the tread. 76 cms.
798 Maximum rise of any floor from the balcony floor to which an access door leads. 20.3 cms
800 Minimum width of a fire escape stair for existing stairs. 55.9 cms.
801 Minimum width of landing for a fire escape stair for existing stairs. 55.9 cms.
802 Minimum tread for a fire escape stair for small buildings. 15.25 cms.
803 Maximum rise of fire escape stair for a small building. 30.5 cms.
804 Maximum rise of fire escape stair for existing stairs. 22.9 cms.
805 Maximum height between landings for a fire escape stair for existing stairs. 3.66 mts.
806 Minimum headroom clearance for a fire escape stair for existing stairs. 2.13 mts.
807 Minimum headroom clearance for a fire escape stair for small buildings. 1.98 mts.
808 Number of exits for place of assembly for 600-1000 occupants. 3
Maximum travel distance between room door intended as exit access and exit
811 30 mts.
with sprinkler system for institutional use.
Maximum travel distance from the door of any room to exit for hotels with
812 30 mts.
sprinkler.
Maximum travel distance from the main entrance door to exit for apartments with
813 31 mts.
sprinkler.
814 Minimum increase in width for an aisle per linear meter. 2.5 cms.
Minimum width of an aisle serving an occupant of 60 or more serving one side for
815 91 cms.
a public assembly building.
818 Minimum width of an aisle for an educational use building. 1.80 mts.
819 Minimum width of an aisle for hospitals or nursing homes. 2.44 mts.
820 Minimum width of an aisle for custodial care institutions. 1.83 mts.
821 Minimum width of an aisle for business use structure. 112 cms.
Courtrooms with an occupant load of more than 100 are classified under what
825 Assembly
classification of occupancy.
Armories with an occupant load of more than 100 are classified under what
826 Assembly
classification of occupancy
Rooms where baled, bundled or piled materials segregated into desired sizes or
828 Picking rooms.
groups.
829 Buildings or structures 15 meters or more in height. High rise building
830 Buildings or structures used for the storage of explosives, shells, projectile, etc. Explosive magazine
833 Descriptive of any substance that ignites spontaneously when exposed to air. Phyrophoric
A process where a piece of metal is heated prior to changing its shape and
835 Forging
dimension.
The process of first raising the temperature to separate the more volatile from the
836 less volatile parts and then cooling and condensing the result vapor so as to Distillation
produce a nearly purified substance.
A finely powdered substance which, when mixed with air in the proper proportion
837 Dust
and ignited will cause an explosion.
840 The temperature at which a liquid is transformed or converted into vapor. Boiling Point
The minimum temperature at which any material gives off vapor in sufficient
843 Flash Point
concentration to form an ignitable mixture with air.
A gas, fume or vapor used for the destruction or control of insects, fungi, vermin,
844 Fumigant
germs, rodents or other pests.
845 Minimum width of any driveway in and around a lumber yard / piles. 4.50 mts.
846 Minimum height of fence for a lumber yard for exterior storage of lumbers. 1.80 mts.
847 Maximum width of sumps for the retention of oil and petroleum products. 3.70 mts.
848 For Refineries, distilleries, and chemical plants, the minimum height for a fence. 1.50 mts.
Minimum travel distance from any individual room subject to occupancy by not
849 15.00 mts.
more 6 persons.
850 Maximum distance of travel from the high hazard area to an exit. 23.00 mts.
Minimum distance of an incinerator from any structure used other than a single
851 3.00 mts.
family dwelling.
856 Maximum height required for a panic hardware installation. 112 cms.
859 Minimum width of a door for family day care homes. 61 cms.
860 Minimum stair width for a class B stair serving an occupant load of less than 50. 91 cms.
Length of a nosing or effective projection over the level immediately below it for
861 25 mm
tread below 25 cms in dimension.
863 A combustible liquid is any liquid having a flash point at or above. 37.8 oC (100 oF)
The time duration that a material or construction can withstand the effect of
864 Fire resistance rating
standard fire test is known as.
Any material which by its nature or as a result of its reaction with other elements
865 Cryogenic
produces a rapid drop in temperature of the immediate surrounding.
866 Classified as mercantile occupancies, the travel distance from exits shall be. 30.50 mts.
867 Under what classification of occupancy does pool rooms fall. Assembly
868 Under what classification of occupancy does home for the aged fall. Institutional
869 Under what classification of occupancy does court houses fall. Business
874 Minimum clear width of aisles for a Class 'A' store. 1.50 mts.
875 Minimum clear width of an exit access through a covered mall. 3.66 mts.
877 Standard inner radius of a curved stair in business occupancies. 763 cms.
880 Minimum width of stair for Class 'B' stairs serving more than 50 persons. 112 cms.
881 Minimum width of stair for Class 'B' stairs serving 50 persons and below. 91 cms.
883 Minimum width of a stair width for Class 'A' stairs. 25 mm.
884 Maximum height between landings for a Class 'B' stairs. 3.70 mts.
885 Minimum width of landings in direction of travel for Class 'A / B' stairs. 112 cms.
889 Maximum height between landings for Class 'A' ramp. No limit
890 Maximum height between landings for Class 'B' ramp. 3.66 mts.
Minimum horizontal dimension of any landing of platform for existing stairs for
893 55.9 cms.
fire escape.
894 Maximum rise for a fire escape for very small buildings. 30.5 cms.
895 Maximum height between landings for fire escape for existing stairs. 3.66 mts.
Class of fire involving ordinary combustible materials, such as wood, papers, cloth,
898 Class A
rubber, and plastics.
904 Under what classification of occupancy does town halls fall? Business
906 Minimum tread for a fire escape stair for existing stairs. 22.9 cms.
907 Maximum spacing of rungs for a fire escape ladder. 30.5 cms.
Class III combustible liquids shall mean any liquid having a flash point at how many
909 60 oC
degrees Celsius?
910 In standard seating, the minimum spacing from back to back. 0.83 mtr.
911 Minimum space from the back of chair to the front of the chair behind. 30 cms.
912 Maximum slope for aisles for public assembly structures. (1:8) 12.5%
913 Size of standpipe provided for each stage for public assembly building. 63.5 mm.
Where exterior corridors or balconies are provided as means of exit, they shall
915 76.25 mts.
open to the outside and shall be spaced ___ meters apart. (Educational)
917 Maximum height from the floor for a rescue window for educational occupancies. 82 cms.
Minimum width of corridors, aisles, and ramps for exits in hospitals and nursing
918 2.44 mts.
homes.
Includes buildings containing three or more living units independent cooking and
922 bathroom facilities, whether or by any other name.designed as rowhouse, Apartment Buildings
apartment house, tenement, garden apartment,
923 Minimum number of stories of apartment buildings requiring fire alarm system. 3
925 An Act to Ordain and Institute the Civil Code of the Philippines RA 0386
926 An Act to Regulate the Practice of Civil Engineering in the Phils. RA 0544
953 explosive compound produced by the reaction of nitric acid w/ cellulose material CELLULOSE NITRATE
954 plastic substance having cellulose nitrate as base PYROXYLIN
956 liquid causes fire when contact with organic matter CORROSIVE LIQUID
958 in air duct system; device to restrict the passage of smoke or fire DAMPER
959 first raising the temperature to separate the more volatile from the less DISTILLATION
minimum temperature at which materials give off vapor to form ignitable mixture
963 FLASH POINT
with air
964 a piece of metal is heated prior to changing its shapes or dimensions FORGING
966 a rocket or liquid propellant when fuels and oxiders combined HYPERGOLIC FUEL
967 materials that readily yields oxygen in quantities sufficient to support combustion OXIDIZING MATERIAL
968 descriptive of any substance that ignites spontaneously when exposed to air PYROPHORIC
970 melting or fusing of metallic ores to separate impurities from pure metals SMELTING
983 difference between developed and undeveloped area on circulation TYPE OF PAVEMENT
998 floor area requirement for single family dwelling unit 20 sqm
1003 minimum door clear height for mezzanine and bathroom 1.80 m
1024 minimum distance of roof eaves between two dwelling units 1.5
1025 minimum distance between two dwelling units (3-4 storeys) 6.00 m
1026 minimum roof eaves distance of two dwelling units (3-4 storeys) 2.00 m
1027 minimum distance between two dwelling units (more than 4 storeys) 10.00 m
1028 minimum horizontal distance of two dwelling units (more than 4 storeys) 6.00 m
1029 minimum roof eaves distance of two dwelling units (more than 4 storeys) 1.00 m
1031 minimum floor area for multi family dwellin units 36.00 sqm
1045 for 4 or more building storey in height w/ roof slope not greater than 1:3 one stairwell
1048 a public way intended to serve for pedestrians and emergency vehicles ALLEY
1049 a parcel of land bounded on the sides by the streets or alleys o pathways BLOCK
1050 a single family attached dwelling containing 3 or more separate living units CLUSTER HOUSING
1051 a wall w/c seperates two abutting living units as to resist the spread of fire FIREBLOCK
1052 a fireblock which extends vertically from the lowest portion of the wall FIREWALL
1053 a wall jointly used by two parties under easements agreement PARTYWALL
50 sqm/10 units 3
1069 parks and playground
sqm/additional unit
1073 required area of playgrounds/parks for every 1,000 sqm 100 sqm
1074 features that enable the disable person to make use of the primary function ACCESSIBLE
1077 the degree of inclination of the sloped surface expressed in ratio GRADIENT OF RAMP
1078 a sloped surface connecting two or more surface at different levels RAMP
1092 centerline height of topmost buttons of elevator and floor switches .90 m - 1.20 m
1096 level area at the top and bottom of any ramp 1.80 m
1103 height of the rim of the fountain from the floor 0.85 m
all on site work done from site preparation, excavation, foundation, installation in
1115 CONSTRUCTION
place of components of a building or structure
1116 any new construction which increases the height or the area of an existing bulding ADDITON
a change in the use or occupancy of the building or any portion thereof which has
1120 CONVERSION
different requirement
a secondary building located within the same premises the use of which is
1124 ANCILLARY BUILDING
incidental to that of the main building