D M A I C AVANTI WIND SYSTEMS

TEST FORM- RAIL SYSTEMS


EN 353-1 : 2002 CSA : Z259.2.1-98

20/05/2015 DIONES/PAULO
Date and year: Competent's name:
RIACHÃO ACA130415T07
Address of installation: Tower No./Serie Nº.:

RUNG FITTINGS ISSUE DESCRIPTION/ COMMENTS


OK not OK
1 Mounted at the beginning and end of each rail X

OK not OK
2 Mounted at least every 3rd step from bottom and up X

OK not OK
3 At each fitting the nut are tightened with 8 nm X

OK not OK
4 Fittings got proper shape without holes and cracks X

OK not OK
All hammerhead bolts are mounted with head marking indicating
5 X
proper head angel of 70° to the rail
OK not OK
6 General all fittings are found in good condition X

RAIL CONNECTIONS ISSUE DESCRIPTION/ COMMENTS


OK not OK
All rail connections has an air gap of minimum 1mm and no gaps
7 X
are larger than 4 mm / 0,1575 inc.
OK not OK
Each fish joint are proper mounted with two hammerhead bolts
8 X
at each rail end, and nuts tightened with 8 nm
OK not OK
All hammerhead bolts are mounted with head marking indicating
9 X
proper head angel of 70° to the rail
OK not OK
10 General all rail connections are found in good condition X

RAIL ISSUE DESCRIPTION/ COMMENTS


OK not OK
11 Are without sharp endings X

OK not OK
12 Has normal shape and no deep scratches, cracks or dents X

OK not OK
13 Looking from front, does the guide claque sit at the left side X

OK not OK
The guide claque has normal shape and no deep scratches,
14 X
cracks or dents
OK not OK
All hammerhead bolts are mounted with head marking indicating
15 X
proper head angel of 70° to the rail
OK not OK
16 General the whole rail arrangement are found in good condition X

GENERAL ISSUE DESCRIPTION/ COMMENTS


OK not OK
17 The rail and fittings are in clean condition X

OK not OK
18 Top and bottom stop are mounted and tightened with 8 nm X

OK not OK
19 Label and marking is legible X

OK not OK
Entire rail installation found with good and safe characteristics
20 X
(final approval)
OK not OK
Are hammerhead bolts and knots (self locking) in stainless
21 X
material
Properly mounted End-stop(s) with 8 nm torque in the OK not OK
22 X
hammerhead bolts are needed
Final Test/Overall Disposition: Is the ladder in overall in good condition? Signature of competent:

Yes Needs Repair Replace


X

Competent inspection may only be performed by AVANTI or Competent person certified by AVANTI. Each 12th month competent inspection has to be carried out, and this filled form must be filed for
possible later reference.

No.: S-3 Form Date of Effect: 2010-06-30 04/ 2010-06-30/KER


Approved by: OJ