Model: CHDDR-AC

Description: Electro-
Electro-hydraulic, self-
self-propelled, mast feed, dual head roof control
drill. Drillheads mounted on extending, swinging and lifting booms.

Dimensions -- JHF Dwg. No. 13-


13-07-
07-98

Length.........................................................................................
Length......................................................................................... 7,200 mm
Walkthru HDDR:
Width (Across Chassis) ..................................................... 2,900 mm
Chassis Height...................................................................
Height................................................................... 1,500 mm
Minimum Operating Height..........................................................
Height.......................................................... 2,100 mm
Maximum Operating Height.........................................................
Height......................................................... 5,000 mm
Underclearance...........................................................................
Underclearance........................................................................... 300 mm
Weight.........................................................................................
Weight......................................................................................... 30,513 Kg
Ground Pressure.........................................................................
Pressure......................................................................... 0.156 Mpa
Maximum Climbing Gradient..............................................
Gradient.............................................. 14º
Maximum Operating Gradient (uphill).........................................
(uphill)......................................... 14º 14º
Maximum Operating Gradient (downhill).....................................
(downhill)..................................... 14º
Minimum Roadway Width for Perpendicular Rib Drilling.............. Drilling.............. 4,000 mm (with “A”
height mast)
Minimum Roadway Width for Angle Rib Drilling .......................... 3,500 mm (with “A”
height mast)

SPECIFICATIONS

Chassis
Heavy duty walk through chassis.
Tram compartment with hydraulically adjustable canopy located in the front middle of the
chassis
T-style TRS (Temporary Roof Support) system with two stage support cylinder:
Extended height ................................................................ 5.00 m
Retracted height ................................................................ 2.10 m
Manually adjustable, TRS beam pad spacing.
Extended beam width ........................................................ 3.66 m
Retracted beam width ....................................................... 3.05 m
M.S.H.A certified load rating .............................................. 18,000 kg
TRS to have lifting and tilting capability for tramming.
Positioning controls located under tram canopy at front of chassis.
Three (one laminated) parts and service manuals.
Optional: Ansul 9.1kg manually actuated, dry chemical fire suppression system.
Zoned lubrication system.
Paint: White

Page 2 of 5
March 2006

Drive System
Fletcher continuous miner type crawler drive system. Hydraulic release, spring set wet
disc park brakes.
Drive reduction enclosed completely within crawler frame, consisting of high speed
planetary, and integral final drive gearbox.
Hydraulic bent axis, variable displacement piston tram motors.
Automatic displacement control that optimizes speed torque output
Motion control valves for dynamic braking
406mm wide x 2,616mm long crawler pads with grease cylinder take-up, and
mechanical shim pack.
Tram speed 0 to 27.0 m/min.
Ground pressure 0.156 Mpa

Dust System

The machine is to be equipped for dry/wet drilling, and will be supplied for use with
22.23 mm (7/8 inches), and 28.58 mm (1 1/8inches) hexagon drill steels.

Dry Drilling System.


M.S.H.A. certified, vacuum type system for hollow shaft drill steels.
Fletcher manual dump dust collectors.
Roots high performance, positive displacement blowers with a capacity of 1.7 cum /
min.
Vacuum at drillhead.....................................................................
drillhead..................................................................... 381-457 mm of Hg
Vacuum regulated by an adjustable relief valve mounted at blower intake.
Separate system for each boom.
Drill hole size 25.4 mm diameter to 42 mm diameter (Depending on the size of the
drill bit and associated drill steel).

Drilling System
Fletcher deep chuck rotary drill heads. Torque 500 Nm @ 138 bar. Rotation speed
approx 450 rpm
On/off bolt torque control for pre-set drill torque output, and minimum thrust.
Two independent boom mounted mast feed drilling systems with hydraulic dropmast
Mast feed drilling system with masts and controls turned inboard.
Thrust..........................................................................................
Thrust.......................................................................................... Variable 0 - 4,500 kg
Mast type....................................................................................
type.................................................................................... Titan AX Mast
Feed length, one time.................................................................
time................................................................. 2,270mm
Mast height collapsed.................................................................
collapsed................................................................. 1,650 mm
Mast height extended..................................................................
extended.................................................................. 2,810 mm
Hydraulic Drill Guide
Feed rate....................................................................................
rate.................................................................................... Variable 0 - 11 m/min
Mast tilt.......................................................................................
tilt....................................................................................... 90° toward the rib, 5º
inboard
Fore/Aft Tilt …………………………………………………………..
Minimum separation of drillheads................................................
drillheads................................................ 1,000 mm
Maximum separation of drillheads...............................................
drillheads............................................... 7,000 mm
Boom extend...............................................................................
extend............................................................................... 600 mm

Page 3 of 5
March 2006

Boom raise ................................................................................. 2,100 mm retract,


2.5m boom extend

Drill operator platform, canopy and materials tray on each boom with automatic
leveling and fore and aft tilt override control.
305 mm Operator platform lift.
Maximum platform elevation of 2.5m above ground.
Driller canopies mounted on two-stage, hydraulically adjustable, telescopic, square
support posts. Canopies are MSHA certified.
Feed package valve.
Hydraulic disconnect bars located at driller stations.

Electrical System
Electrical system to be approved by DGMS Dhambad for use in Indian gassy coal
mines. Electrics to be suitable for an operating voltage 1100AC, 3 phase, 50 Hz.
This to include all electric motors (2 x 37 Kw @1450 rpm), lights, permissible
electrical enclosures, motor controls, cable reel, high temperature shutdown, oil level
shutdown, and switch enclosures.

Hydraulic System
Maximum working pressure........................................................
pressure........................................................ 240 bar
Pressurized hydraulic tank with breather.
System capacity..........................................................................
capacity.......................................................................... 450 litres
System fluid................................................................................
fluid................................................................................ Fireresistant
Quintalubric
Hand operated fill pump with screened in-take.
Filtration: magnetic suction separator, Pall high pressure filters on each high flow
pump circuit.
Hose fittings................................................................................
fittings................................................................................ JIC
Fitting in hydraulic components and control valves.....................
valves..................... SAE O-ring
Manuli hoses with minimum operating pressure rating of 241 bar (3,500 psi).
Pumps: dual commercial P350/315 series, 117.3 l/min and 28.4 l/min.
25.4 mm hoses on high flow circuit.
Pressure gauge on each pump section.
Main relief valve.

Options included
“W” strap holder mounted on ATRS (Note: will affect centre bolt spacing)
Manual Fire suppression system
Front Stabilizer cylinders
Rear Stabilizer cylinders
Wet drilling system with water pressure regulator, strainer, shut-off valves.

Page 4 of 5
March 2006

FEEDER BREAKER - SPECIFICATIONS


General
Overall Length 10,528 mm
Overall Width 3,149mm
Operating Height
(Max) 1,981 mm
Level Hopper
Capacity 12.46 m3
Approximate Weight 31,752 kg
Conveyor Chain
Flights 63.5 mm x 139.7 mm Solid Alloy Steel
Conveyor Speed 15 - 41 meters/minute
Radial Piston Hydraulic Low Speed
Drive Motor High Torque
Breaker  
Running Pick Force 4264 kg force
Pick Force Maximum 36,287 kg force
Breaker Speed 67 RPM
Drive Motor- 150kW/1140v/AC/50Hz/TEFC
Crawlers
Tram Speed 14.33 m/min
Drive Fairfield W12 Torque Hub
Overall Length 2,451 mm
Center-to Center
Distance 2,007 mm
Pad Width 381 mm
Ground Pressure 174.44 kPa
Hydraulic
Conveyor/Tram
Pump- Axial Piston, Variable Displacement
Tram Motors Char Lynn 4000 series, 19in3/rev
662.4 litre Capacity, with low oil level
Reservoir switch
Electrical
Breaker Motor 150kW/1140v/AC/50Hz/1750rpm/TEFC
150kW/Single/1140v/AC/50Hz/mine
Starter duty
IP65 rating, adequate for low pressure
Enclosure