You are on page 1of 5

SIMATIC

FC24 - <offline>
"BUA_bundle alignment" bundle alignment
Name: FC_8 Family:
Author: ETRS Version: 0.0
Block version: 2
Time stamp Code: 07/11/2016 01:07:10 PM
Interface: 08/15/1997 02:46:30 PM
Lengths (block/logic/data): 00314 00166 00002

Name Data Type Address Comment


IN 0.0
OUT 0.0
IN_OUT 0.0
TEMP 0.0
RETURN 0.0
RET_VAL 0.0

Block: FC24 Bündelausrichter Radimat

bundle alignment Radimat

Network: 1 Ausgänge Bündelausrichter

outputs bundle aligment

---------------------------------------
A u s g ä n g e a n s t e u e r n
o u t p u t c o n t r o l
---------------------------------------

Seite von
SIMATIC

Network: 2 Bündelausrichter

release for bundle alignment

T21
BUA delay
bag
bundle
alignment
on
"BUA_T_21"
S_ODT
M225.2
IN-bundle
transp.tra
nsfer
pos.
occupied
"BUT_E_
occupied" S

DB40.DBW42
"Timer_ BI
RAD".
STAT21 TV BCD
&
R Q

M123.7
Radimat ON
"RAD_M_
123.7"

M125.1
Machine
Start/Stop >=1
"START"

DB106.DBX1
1.1
BUA
bundle
alignement M224.7
forward OUT-bundle
- backward alignment
"TC_Test_ on
Code". & (BUNDLE)
ANTR_Nr10 /
Alignment
M84.0 motor on
general (REEL)
fault "BUA_A_on"
alignment =
"BUA_FM"

T20
BUA delay
bag
bundle
alignment
is
advanced
"BUA_T_20"
S_ODT
S

DB40.DBW40
"Timer_ BI
RAD".
STAT20 TV BCD

R Q

Seite von
SIMATIC

Network: 3 Testcodes 10 rücksetzen

reset testcode 10 reset

>=1
DB102.DBX2
.3
Radimat
emergency
stop or
safety
switch
actuated
"FM_
Faults".
FLT_20

DB102.DBX3
.1
Compressed
air DB106.DBX1
Radimat P 1.1
< 4,5 bar BUA
"FM_ bundle
Faults". alignement
FLT_26 forward
- backward
M84.0 "TC_Test_
general Code".
fault ANTR_Nr10
alignment R
"BUA_FM"

Network: 4 Störungen Bündelausrichter

faults bundle aligment

-----------------------------------------------
S t ö r u ng e n // M e l d u n g e n
f a u l t // m e s s a g e s
-----------------------------------------------

Seite von
SIMATIC

Network: 5 Störung Bewegung Bündelausrichter

motion control bundle alignment

&
M224.7
OUT-bundle
alignment
on
(BUNDLE)
/
Alignment
motor on
(REEL)
"BUA_A_on"

M224.6
IN-bundle
alignment
in front
position
"BUA_E_ >=1
front_pos"

&
M224.7
OUT-bundle
alignment
on
(BUNDLE)
/
Alignment
motor on
(REEL)
"BUA_A_on"

M224.6
IN-bundle
alignment
in front
position
"BUA_E_ &
front_pos"

&
M123.7
Radimat ON
"RAD_M_
123.7"

M125.1
Machine
Start/Stop >=1
"START"

M59.4
Picture
33 -
individual
drive
test mode
RADIMAT T142
"Maske_33" BUA delay
fault
T1 movement
RAD delay bundle
Radimat alignment
pressure "BUA_T_
build-up 142"
time S_ODT
"RAD_T_1" S
BI
S5T#1S500M
S TV BCD

R Q

Seite von
SIMATIC

Network: 6 Störung Bewegung Bündelausrichter

motion control bundle alignment

&
M221.3 DB102.DBX9
OUT-acknow .6
ledge Fault
fault movement
"0_A_ackn_ bundle
flt" alignment
at
T142 trasfer
BUA delay table
fault Radimat
movement "FM_
bundle Faults".
alignment FLT_79
"BUA_T_ >=1 SR
142" T142
BUA delay
M104.0 fault
Aux. flag movement
general bundle
conditions alignment
to FAULT "BUA_T_
RESET 142" S
"RAD_M_
104.0" R Q

Network: 7 Sammelstörung Bündelausrichter

general fault bundle alignement

&
DB102.DBX9
.6
Fault
movement
bundle
alignment
at M84.0
trasfer general
table fault
Radimat alignment
"FM_ "BUA_FM"
Faults". =
FLT_79

Seite von

You might also like