0mm
PE Outer/Inner Sheath, Steel Wire Armored
Application: Direct Buried in High Humidity Areas or Directly in Water
Cable cross-section and dimensions
2
GYFTY33-24 G.652D(2.0mm)inner sheath 2.0mm
PE Outer/Inner Sheath, Steel Wire Armored
Application: Direct Buried in High Humidity Areas or Directly in Water
Cable cross-section and dimensions
4
Description
CABLE, rated cable that consists of loose tubes stranded around the non-metal central
strength member(FRP). The loose tube with PBT plastic material, containing 6 fibers and
filled with a suitable water tightness jelly, at the same time, the longitudinal water tightness
for wet core with cable filling compound, strictly guaranteed the water blocking & moisture
proof, meets the Water Penetration IEC 60794-1-2-F5B(remove armored layer). The cable
is completed with outer PE sheath sheath and inner PE sheath, steel wire armored, main
application environment: direct buried in high humidity areas or directly in water. The loose
tube sheathing is made of high modulus plastics (PBT). The individual fibers are secondary
coated into the loose tube with suitable excess length and the tube is filled with tube filling
compound. Precision design and optimum control of excess length of the fibers in the tube to
ensure suited strain on the fibers, individually or collectively.
1. Operating Conditions
Item Parameter
Installation -25℃ to +70℃
Temperature Operation -25℃ to +70℃
Transportation -25℃ to +70℃
IEC 60794-1-2-F5B
Water Penetration 3m sample, 1m height, 24 h, No water leakage
Refer to IEC 60794-1-2-F5B, remove armored layer
Main Application Environment Direct buried in high humidity areas or in water
Lifespan ≥25 years
2. Fiber characteristics
This single mode optical fiber cable shall comply with the requirements of this
specification, ITU-T G.652D.
5
Table 2.1 G.652D fiber characteristics
FiberHome’s G.652D fiber characteristics meets ITU-T G.652D standard
6
3. Fiber and Loose Buffer Tube Identification
The color code of the loose buffer tubes and the individual fibers within each loose
buffer is displayed in tables 3.1 for the loose buffer tubes and 3.2 for the individual
fibers.
Position Color
1 Blue
2 Orange
3 Green
4 Brown
Position Color
1 Blue
2 Orange
3 Green
4 Brown
5 Grey
6 White
1) Manufacturer: FIBERHOME
2) Cable Type: GYFTY33
3) Cable Cores: 24FO
4) Fiber Type: G.652D
5) Client name: SATTELITAL
6) Manufacturing year: 2021
7) Length Mark: 0001m (for example: 0001m, 0002m, 0003m…)
7
4.2 Cable Packing
Standard length of cable shall be 6000/10,000m per reel with a tolerance of -3%/+3%.
Other cable lengths are also available if requested by customer.
Both ends of the cable shall be sealed with suitable plastic caps to prevent the entry of
moisture during shipping, handling and storage.
The cable ends shall be securely fastened to the reel to prevent the cable from
becoming loose in transit or during placing operations.
The inner end of the cable is housed into a slot on the side of the reel without extra
cable length for testing.
Circumference battens or wood-fiber board shall be secured with bands to protect the
cable during normal handling and shipping.
8
4.3.2 Other shipping mark is also available if requested by customer.
4.3.3 The cable shall be shipped on reels designed to prevent damage to the
cable during shipment and installation.
4.3.4 The arbor holes provided in the reels shall be approximately 105 mm with
a wood or steel hub in the arbor hole (in lieu of fiberboard).