Professional Documents
Culture Documents
1 2 3 4 5 6 7 8 9 10 11 12
REV DATE MADE APPVD. EXPLANATION
A 1.11.2017 FIRASHN Positions A, B1, B2, Q moved. Pos XX removed
Abt. 4017
A A
B1 Ae1 Ae2 D1 A
1080
1080
600
240
110
350
630
0
Savety valve blow out pipe Abt. 1752 ASSEMBLY TOLERANCES FOR FOUNDATIONS
THE FOLLOWING GENERAL TOLERANCES ARE TO BE FOLLOWED DURING
ASSEMBLY OF BASE PLATES OR ANCHOR BOLTS TO THE CONCRETE BED:
Ae2 CENTER LINE DISTANCE INSIDE ONE ANCHOR BOLT GROUP 2
DIAGONAL DIMENSION INSIDE ONE ANCHOR BOLT GROUP 3
Ae1 2417 ELEVATION POSITION FOR ANCHOR BOLTS 10
B CENTER LINE DISTANCE BETWEEN ANCHOR BOLT GROUPS 5 B
2255 STRAIGHTNESS OF BASE PLATES 2
CENTER LINE DISTANCE BETWEEN BASE PLATES 5
ELEVATION POSITION FOR BASE PLATES 5
1800
1117
JB
Abt. 2700
GENERAL TOLERANCE FOR TERMINAL POINTS: 20
L1 C
1255
Aa1 WEIGHT INFORMATION TABLE
DRY WEIGHT: 3200
C R C
MAX. WEIGHT: 9200
100
905
260
B B
30 0
692 Q
+Z +Z 852
B2
1653
720
460
460
1110
2014
2144
G2
-Y
D +X G2 Ad Q B2 C1 K G4 D
X11
X12
NOTE:
Ae3
Tank heating valves as loose supply.
Related piping and supports not in ALA scope
of supply.
E G4 E
1772 3D-View ( 1:50 )
1572
1272 x x x x x x x x x X12 LEVEL INDICATOR
K x x x x x x x x x X11 LEVEL INDICATOR
114 130
x x x x x x x x x R INSTRUMENT AIR D=10mm
Fixed leg Sliding leg Service space 1000 mm
x x x x x x x x x Q ECO RISER DN50 PN40
x x x x x x x x x L1 MANHOLE
E C ( 1:10 ) 0,1 0,1 0,1 0,1 0,1 0,1 1,5 7,5 25,6 K STEAM HEATING DN25 PN40
0,1 0,1 0,1 0,1 0,1 0,1 1,5 7,2 25 G4 CONDENSATE RETURN DN25 PN40
F 0,1 0,1 0,1 0,1 0,1 0,1 -3 -0,8 25 G2 BLOW DOWN DN25 PN40
F
1 1 1 0,1 0,1 0,1 3 0 29 D1 VENTING DN25 PN40
x x x x x x x x x C1 DRAIN G " (f)
1850
1752
1558
1 /1 1:30 A2 8030-19M A
Rev.
1 2 3 4 5 6 7 8 9 10 11 12