Professional Documents
Culture Documents
15.4 Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO add dismantled RRU2100 3 sector 26
15.5a Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO cascade WRFU 4 sector 4
15.6a Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO cascade WRFU 5 sector 14
15.7a Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO cascade WRFU 6 sector 4
16.1a Upgrade L18 SIMO to MIMO existing RRU license only & L21 MIMO existing RRU license 3 sector 1
16.1b Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & L21 MIMO cascade WRFU 3 sector 7
16.2a Upgrade L18 SIMO to MIMO add new RRU & L21 MIMO new RRU 3 sector (3G reduce to 3 sector) 21
Wireless SOW- 3779 sites(76 Scenarios )
Scenario Site Qty
17.1 Upgrade L18 SIMO use dismantled RRU license only & L21 SIMO to MIMO existing RRU license 3 sector 4
2.4 Upgrade L1800 1T3S to 2T6S & Upgrade L2100 SISO to 2T6S 11
2.5 Upgrade L1800 1T3S to 2T6S & Upgrade L2100 2T3S to 2T6S 1
2.6 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SIMO to 2T6S 1
2.7 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SISO to 2T6S 63
2.8 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 2T3S to 2T6S 82
3.2 Add L2100 SISO WRFU 3 Sector 51
3.2a Add L2100 SISO WRFU 3 Sector (with UBBP) 2
3.2a.1 Add L2100 SISO WRFU 3 Sector (add dismantled BBP) 2
3.2b Add L2100 SISO WRFU 2 Sector 1
3.3 Add L2100 SISO RRU 3 Sector 3
3.4 Add L2100 SISO WRFU 4 Sector 76
3.5 Add L2100 SISO WRFU 5 Sector 64
3.6 Add L2100 SISO WRFU 6 Sector 18
4.2 Add L2100 SISO WRFU 3 Sector (Existing L18 MIMO) 19
4.2a Add L2100 SISO WRFU 1 Sector (Existing L18 MIMO) 1
4.2b Add L2100 SISO WRFU 3 Sector (with UBBP) (Existing L18 MIMO) 2
4.2b.1 Add L2100 SISO WRFU 3 Sector (add dismantled BBP) (Existing L18 MIMO) 1
4.3 Add L2100 SISO RRU 3 Sector (Existing L18 MIMO) 6
4.4 Add L2100 SISO WRFU 4 Sector (Existing L18 MIMO) 47
4.4b Add L2100 SISO RRU 4 Sector (Existing L18 MIMO) 1
4.5 Add L2100 SISO WRFU 5 Sector (Existing L18 MIMO) 59
4.6 Add L2100 SISO WRFU 6 Sector (Existing L18 MIMO) 37
5.1 Add L2100 SIMO RRU License only 13
5.2 Add L2100 SIMO 3 Sector New RRU 20
5.3 Add L2100 SIMO 3 Sector Cascade WRFU 1
5.4 Add L2100 SIMO 5 Sector New RRU 1
6.1 Add L2100 SIMO RRU License only (Existing L18 MIMO) 54
6.2 Add L2100 SIMO cascade WRFU only 4 sector (Existing L18 MIMO) 2
7.1 Add L2100 MIMO 3 Sector Cascade WRFU 9
7.1a Add L2100 MIMO add new RRU 3 Sector 91
7.1b Add L2100 MIMO 3 Sector Cascade WRFU (add UBBP) 1
8.1 Add L1800 SIMO 3 Sector New RRU 267
8.1a Add L1800 SIMO 3 Sector use dismantled RRU 62
8.2 Add L1800 SIMO 3 sector on existing GRFU/MRFU 1
8.3 Add L1800 SIMO 2 Sector New RRU 1
9.1 Add L1800 MIMO 3 Sector add dismantled RRU 9
Scenario 1.1 Upgrade L1800 1T3S to 2T6S & Add New L2100 1T6S
UBBPe4
FANc
UPEUd
UBBPd4
UPEUd
UBBPd4
UBBPe4 UMPTb1 UBBPe4 UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
UBBPe4
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
UBBPe4
FANc
FANc
UPEUd
UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 1.4 Upgrade L1800 1T3S to 2T6S & Upgrade L2100 (SISO) 1T3S to 1T6S
1st Condition:Existing RFU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R
UBBPe4
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
UBBPe4
FANc
FANc
UPEUd
UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 1.6 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SIMO to 1T6S
1st Condition:Existing RFU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R
UBBPe4
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
UBBPe4
FANc
FANc
UPEUd
UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 1.7 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SISO to 1T6S
1st Condition:Existing RFU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R
UBBPe4
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
UBBPe4
FANc
FANc
UPEUd
UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 1.8 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 MIMO to 1T6S
1st Condition:Existing RFU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R
UBBPe4
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
UBBPe4
FANc
FANc
UPEUd
UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 2.4 Upgrade L1800 1T3S to 2T6S & Upgrade L2100 SISO to 2T6S
UBBPe4
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
UBBPe4
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
UBBPe4
FANc
FANc
UPEUd
UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 2.7 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SISO to 2T6S
1st Condition:Existing RFU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R
UBBPe4
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
UBBPe4
FANc
FANc
UPEUd
UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 2.8 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 2T3S to 2T6S
1st Condition:Existing RFU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R
UBBPe4
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
UBBPe4
FANc
FANc
UPEUd
UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 3.2 Add L2100 SISO WRFU 3 Sector
FANc
UPEUd
WBBP
FANc
UPEUd
UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add 2 pcs WRFU 80W(if any)
Dismantle WRFU 40W board, Packing and Deliver
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
to WH(if any)
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
80W
80w
BOTTOM OF RACK
BOTTOM OF RACK
Scenario 3.2a Add L2100 SISO WRFU 3 Sector (with UBBP)
FANc
UPEUd
WBBP UBBPe4
FANc
UPEUd
UBBPd UMPTb1
UBBPd UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
Move SFP cable to UBBPe4 (1800M to port 0,1,2,
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK
BOTTOM OF RACK
Scenario 3.2a.1 Add L2100 SISO WRFU 3 Sector (add dismantled BBP)
FANc
UPEUd
WBBP UBBP
FANc
UPEUd
UBBPd UMPTb1
UBBPd UMPTb1 Add new 1 pcs UBBP/LBBP at slot 2 or other idle slot(slot 0 to 3)
Move L2100 SFP cable to UBBP/LBBP (port 0,1,2)
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK
BOTTOM OF RACK
Scenario 3.4 Add L2100 SISO WRFU 4 Sector
FANc
UPEUd
WBBP UBBPe4
FANc
UPEUd
UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK
BOTTOM OF RACK
Scenario 3.5 Add L2100 SISO WRFU 5 Sector
FANc
UPEUd
WBBP UBBPe4
FANc
UPEUd
UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK
BOTTOM OF RACK
Scenario 3.6 Add L2100 SISO WRFU 6 Sector
FANc
UPEUd
WBBP UBBPe4
FANc
UPEUd
UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK
BOTTOM OF RACK
Scenario 4.2b Add L2100 SISO WRFU 3 Sector (with UBBP) (Existing L18 MIMO)
FANc
UPEUd
WBBP UBBPe4
FANc
UPEUd
UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK
BOTTOM OF RACK
Scenario 4.2b.1 Add L2100 SISO WRFU 3 Sector (add dismantled BBP) (Existing L18 MIMO)
FANc
UPEUd
WBBP UBBPd4
FANc
UPEUd
UBBPd4 UMPTb1
UBBPd4 UMPTb1 Add new 1 pcs UBBPd4 at slot 2 or other idle slot(slot 0
to 3)
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK
BOTTOM OF RACK
Scenario 4.4 Add L2100 SISO WRFU 4 Sector (Existing L18 MIMO)
FANc
UPEUd
WBBP UBBPe4
FANc
UPEUd
UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK
BOTTOM OF RACK
Scenario 4.4b Add L2100 SISO RRU 4 Sector (Existing L18 MIMO)
FANc
UPEUd
WBBP UBBPe4
FANc
UPEUd
UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)
BOTTOM OF RACK
BOTTOM OF RACK
Scenario 4.5 Add L2100 SISO WRFU 5 Sector (Existing L18 MIMO)
WBBP WBBP
FANc
FANc
UPEUd
UPEUd
UBBPe4
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0 UBBPe4 UMPTb1
to 3)
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK BOTTOM OF RACK BOTTOM OF RACK
Scenario 4.6 Add L2100 SISO WRFU 6 Sector (Existing L18 MIMO)
WBBP WBBP
FANc
FANc
UPEUd
UPEUd
UBBPe4
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0 UBBPe4 UMPTb1
to 3)
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK BOTTOM OF RACK BOTTOM OF RACK
Scenario 5.2 Add L2100 SIMO 3 Sector New RRU
L2100 RRU3959a
BTS3900A
BTS3900A L1800 RRU3959a 2T2R
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
WBBP
Install new 3 pcs L2100 RRU3959 and
FANc
WBBP
UPEUd
UPEUd
DCDU
DCDU
FMU
FMU
BOTTOM OF RACK
BOTTOM OF RACK
BTS3900A BTS3900A
L1800 RRU3959a L1800 RRU3959a
TCU 2T2R TCU 2T2R
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU
PDU PDU
FANc
UPEUd
UPEUd
UBBPe4 UBBPe4
WBBP UMPT WBBP UMPT
DCDU DCDU
FMU FMU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK BOTTOM OF RACK
BTS3900A
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R L2100 RRU3959a
SLPU
SLPU 2T2R
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
WBBP
Add new 1 pcs UBBPe4 at slot 2
FANc
WBBP
UPEUd
UBBPe4
UPEUd
BOTTOM OF RACK
BOTTOM OF RACK
BTS3900A BTS3900A
L1800 RRU3959a L1800 RRU3959a
TCU 2T2R TCU 2T2R
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU
PDU PDU
FANc
UBBPe4
UPEUd
UPEUd
UBBPe4 UBBPe4
Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0 to 3)
WBBP UMPT WBBP UMPT
add new 4 or 6 pcs WRFU(80W),then Casecade RFU for each sector
Dismantle WRFU board, Packing, and Deliver to WH
DCDU DCDU
FMU FMU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK BOTTOM OF RACK BOTTOM OF RACK
BTS3900A
BTS3900A
TCU
TCU
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
Add new RFC Cabinet (if any)
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
Add new 3 or 4 or 6 pcs WRFU,then Casecade RFU for WBBP UMPT
WBBP UMPT
each sector
DCDU DCDU
DCDU
FMU
FMU
G1800 MRFU
G1800 MRFU
G1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 MRFU
G1800 MRFU
G1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
L2100 RRU3959a
BTS3900A
BTS3900A 2T2R
TCU
TCU
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
Install new 3 pcs L2100 RRU3959 and
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
connect to UBBPe4 (port 3,4,5) WBBP UMPT
WBBP UMPT
Dismantle WRFU board, Packing, and Deliver to WH
DCDU
DCDU
FMU
FMU
G1800 MRFU
G1800 MRFU
G1800 MRFU
G1800 MRFU
G1800 MRFU
G1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK
BOTTOM OF RACK
BTS3900A
BTS3900A
TCU
TCU
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
UBBPe4
Add new RFC Cabinet
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
Add 1 pcs new UBBPe4 in slot 1 WBBP UMPT
WBBP UMPT
Add new 3 pcs WRFU,then Casecade RFU for each sector
DCDU DCDU
DCDU
FMU
FMU
G1800 MRFU
G1800 MRFU
G1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 MRFU
G1800 MRFU
G1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
L1800 RRU3959a
BTS3900A
BTS3900A L2100 RRU3959a 2T2R
L2100 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
UBBPe4
Install new 3 pcs L1800 RRU3959 and
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
connect to UBBPe4 (port 0,1,2) WBBP UMPT
WBBP UMPT
Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3)
DCDU
DCDU
FMU
FMU
BOTTOM OF RACK
BOTTOM OF RACK
L1800 RRU3959a
BTS3900A
BTS3900A L2100 RRU3959a 2T2R
L2100 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
UBBPe4
Install new 3 pcs L1800 RRU3959(from H3I) and
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
connect to UBBPe4 (port 0,1,2) WBBP UMPT
WBBP UMPT
Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3)
DCDU
DCDU
FMU
FMU
BOTTOM OF RACK
BOTTOM OF RACK
BTS3900A
BTS3900A L2100 RRU3959a
L2100 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
UBBPe4
Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3)
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT
DCDU
DCDU
FMU
FMU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BOTTOM OF RACK
BOTTOM OF RACK
L1800 RRU3959a
BTS3900A
BTS3900A 2T2R
L2100 RRU3959a TCU
TCU 2T2R SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
UBBPe4 UBBPe4
UBBPe4
FANc
UBBPe4
Install new 2 pcs L1800 RRU3959(from H3I) and
FANc
UBBPe4
UPEUd
UBBPe4
UPEUd
UBBPe4
connect to UBBPe4 (port 0,1,2) UBBPe4 UMPT
UBBPe4 UMPT
Add UBBPe4 in slot 4
DCDU
DCDU
FMU
FMU
BOTTOM OF RACK
BOTTOM OF RACK
L1800 RRU3959a
BTS3900A
BTS3900A L2100 RRU3959a 2T2R
L2100 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
UBBPe4
Install new 3 pcs L1800 RRU3959(from H3I) and
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
connect to UBBPe4 (port 0,1,2) WBBP UMPT
WBBP UMPT
Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3)
DCDU
DCDU
FMU
FMU
BOTTOM OF RACK
BOTTOM OF RACK
BTS3900A
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
FANc
UPEUd
RFU for each sector UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT
DCDU DCDU
DCDU
FMU
FMU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BTS3900A
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
FANc
UPEUd
RFU for each sector UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT Add new RFC Cabinet(if any)
DCDU DCDU
DCDU
FMU
FMU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
L2100 RRU3959a
BTS3900A
BTS3900A L1800 RRU3959a 2T2R
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
FANc
UPEUd
connect to UBBPe4 (port 3,4,5) UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT Dismantle WRFU board, Packing, and Deliver to WH
DCDU
DCDU
FMU
FMU
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BOTTOM OF RACK
BOTTOM OF RACK
L2100 RRU3959a
BTS3900A
BTS3900A L1800 RRU3959a 2T2R
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
FANc
UPEUd
connect to UBBPe4 (port 3,4,5) UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT Dismantle WRFU board, Packing, and Deliver to WH
DCDU
DCDU
FMU
FMU
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BOTTOM OF RACK
BOTTOM OF RACK
L2100 RRU3959a
BTS3900A 2T2R
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
FANc
UPEUd
connect to UBBPe4 (port 2,3,4,5) UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT Dismantle WRFU board, Packing, and Deliver to WH
DCDU
DCDU
FMU
FMU
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BOTTOM OF RACK
BOTTOM OF RACK
L2100 RRU3959a
BTS3900A 2T2R
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
UBBPe4
FANc
UPEUd
connect to UBBPe4 (port 2,3,4,5) UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT √ Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3)
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BOTTOM OF RACK
BOTTOM OF RACK
L2100 RRU3959a
BTS3900A 2T2R
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
UBBPe4
FANc
UPEUd
connect to UBBPe4 (port 2,3,4,5) UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT √ Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3)
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BOTTOM OF RACK
BOTTOM OF RACK
L2100 RRU3959a
BTS3900A
BTS3900A L1800 RRU3959a 2T2R
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
FANc
UPEUd
connect to UBBPe4 (port 3,4,5) UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT Dismantle WRFU board, Packing, and Deliver to WH
DCDU
DCDU
FMU
FMU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK
BOTTOM OF RACK
BTS3900A
BTS3900A
TCU
TCU 2-P Antenna 2-P Antenna SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
Combiner Combiner
FANc
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
1T2R 1T2R WBBP UMPT
WBBP UMPT 1T2R 1T2R 1T2R
RFU RFU RFU RFU RFU
DCDU DCDU
DCDU
FMU
FMU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BTS3900A
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 1T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
FANc
UPEUd
connect to UBBPe4 (port 0,1,2) UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT Dismantle L1800M 1T2R RRU, Packing, and Deliver to WH
DCDU
DCDU
FMU
FMU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK
BOTTOM OF RACK
BTS3900A
BTS3900A
TCU
TCU 2-P Antenna 2-P Antenna SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
Combiner Combiner
FANc
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
1T2R 1T2R WBBP UMPT
WBBP UMPT 1T2R 1T2R 1T2R
RFU RFU RFU RFU RFU
DCDU DCDU
DCDU DCDU Install new 2 pcs GRFU/MRFU,then FMU
FMU
Casecade
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
TCU TCU
SLPU SLPU
FANc
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPT WBBP UMPT
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
TCU TCU
SLPU SLPU
FANc
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPT WBBP UMPT
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
TCU TCU
SLPU SLPU
FANc
UBBPe4
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPT WBBP UMPT
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
TCU TCU
SLPU SLPU
FANc
UBBPe4
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPT WBBP UMPT
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU
Combiner Combiner
PDU PDU
FANc
RRU RRU
UBBPe4
RRU RRU
UPEUd
UPEUd
UBBPe4 UBBPe4
WBBP UMPT WBBP UMPT
DCDU DCDU
FMU Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3) FMU
TCU TCU
SLPU SLPU
FANc
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPT WBBP UMPT
Add new RFC Cabinet(if any)
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
FANc
FANc
UPEUd
RFU RFU UBBPe4
UPEUd
UBBPe4
WBBP UMPT WBBP UMPT
√ Add 3 pcs L1800 new RRU
√ Dismantle GRFU/MRFU DCDU
DCDU
FMU √ Install Install 3 or 4 or 6 pcs WRFU,then FMU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100WRFU
Casecade RFU for each sector
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
FANc
FANc
UPEUd
RFU RFU UBBPe4
UPEUd
UBBPe4
WBBP UMPT WBBP UMPT
√ Add 3 pcs L1800 RRU(from H3I)
√ Dismantle GRFU/MRFU DCDU
DCDU
FMU √ Install Install 3 or 4 or 5 or 6 pcs WRFU,then FMU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100WRFU
Casecade RFU for each sector
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
FANc
2T2R
RFU
FANc
RFU RRU
RRU
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT
√ Add 3 pcs L1800 and 3 pcs L2100 RRU(from H3I)
√ Dismantle GRFU/MRFU and WRFU DCDU
DCDU
FMU
FMU √ Connect L1800 RRU fiber to UBBPe4 (port 0,1,2),L2100 RRU
fiber to UBBPe4 (port 3,4,5)
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BOTTOM OF RACK
BOTTOM OF RACK
BTS3900A
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
FANc
UPEUd
Casecade RFU for each sector UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT
DCDU
DCDU
FMU
FMU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
BOTTOM OF RACK
BOTTOM OF RACK
BTS3900A
BTS3900A L2100 RRU3959a
L2100 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
FANc
FANc
UPEUd
Casecade RFU for each sector UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT
DCDU
DCDU
FMU
FMU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BOTTOM OF RACK
BOTTOM OF RACK
FANc
2T2R
RFU
FANc
RFU RRU
RRU
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT
√ Add 3 pcs L1800 and 3 pcs L2100 RRU(from H3I)
√ Dismantle GRFU/MRFU and WRFU DCDU
DCDU
FMU
FMU √ Connect L1800 RRU fiber to UBBPe4 (port 0,1,2),L2100 RRU
fiber to UBBPe4 (port 3,4,5)
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BOTTOM OF RACK
BOTTOM OF RACK
BTS3900A BTS3900A
L1800 RRU3959a
TCU 2T2R
TCU Combiner
SLPU Combiner SLPU
FANc
FANc
√ Dismantle GRFU/MRFU
UPEUd
UBBPe4
UPEUd
UBBPe4
√ Install Install 4 pcs WRFU,then WBBP UMPT
WBBP UMPT
Casecade RFU for each sector
Dismantle GRFU/MRFU, Packing, and Deliver to WH DCDU DCDU
DCDU DCDU
FMU FMU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BTS3900A BTS3900A
L1800 RRU3959a
TCU 2T2R
TCU Combiner
SLPU Combiner SLPU
FANc
FANc
√ Dismantle GRFU/MRFU
UPEUd
UBBPe4
UPEUd
UBBPe4
√ Install Install 6 pcs WRFU,then WBBP UMPT
WBBP UMPT
Casecade RFU for each sector
Dismantle GRFU/MRFU, Packing, and Deliver to WH DCDU DCDU
DCDU DCDU
FMU FMU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BTS3900A BTS3900A
L1800 RRU3959a
TCU 2T2R
TCU Combiner
SLPU Combiner SLPU
FANc
FANc
√ Dismantle GRFU/MRFU
UPEUd
UBBPe4
UPEUd
UBBPe4
√ Install Install 6 pcs WRFU,then WBBP UMPT
WBBP UMPT
Casecade RFU for each sector
Dismantle GRFU/MRFU, Packing, and Deliver to WH DCDU DCDU
DCDU DCDU
FMU FMU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
FANc
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4 UMPT
UBBPe4 UMPT
√ Add 1 pcs UBBPe4 on slot 2
DCDU
DCDU
FMU
FMU
BOTTOM OF RACK
BOTTOM OF RACK
TCU TCU
SLPU SLPU
FANc
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPT WBBP UMPT
Add new RFC Cabinet
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
FANc
2T2R
RFU
FANc
RFU RRU
RRU
UPEUd
UBBPe4
UPEUd
UBBPe4
WBBP UMPT
WBBP UMPT
√ Add 3 pcs L1800 and 3 pcs L2100 new RRU
√ Dismantle GRFU/MRFU and WRFU DCDU
DCDU
FMU
FMU √ Connect L1800 RRU fiber to UBBPe4 (port 0,1,2),L2100 RRU
fiber to UBBPe4 (port 3,4,5)
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BOTTOM OF RACK
BOTTOM OF RACK
FANc
FANc
UPEUd
UBBPe4
UPEUd
UBBPe4 UMPT
UBBPe4 UMPT
√ Add 1 pcs UBBPe4 on slot 2
√ Add 3 pcs L1800 RRU(from H3I), Connect L1800 RRU DCDU
DCDU
FMU
FMU fiber to Slot 3 UBBPe4 (port 0,1,2)
BOTTOM OF RACK
BOTTOM OF RACK