SOP - H3I 3779 4G Expansion

Wireless SOW- 3779 sites(76 Scenarios )


Scenario Site Qty
1.1 Upgrade L1800 1T3S to 2T6S & Add New L2100 1T6S 1
1.2 Upgrade L1800 2T3S to 2T6S & Add New L2100 1T6S 29
1.4 Upgrade L1800 1T3S to 2T6S & Upgrade L2100 (SISO) 1T3S to 1T6S 95
1.6 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SIMO to 1T6S 3
1.7 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SISO to 1T6S 319
1.8 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 MIMO to 1T6S 100
10.1 Upgrade L2100 SISO to MIMO cascade WRFU 2 Sector 2
10.2 Upgrade L2100 SISO to MIMO cascade WRFU 3 Sector 443
10.3 Upgrade L2100 SISO to MIMO add dismantled RRU2100 3 Sector 6
10.3a Upgrade L2100 SISO to MIMO add New RRU 3 Sector 142
10.4a Upgrade L2100 SISO to MIMO add New RRU 4 Sector 19
10.5a Upgrade L2100 SISO to MIMO add New RRU 5 Sector 18
10.6a Upgrade L2100 SISO to MIMO add New RRU 6 Sector 13
11.1 Upgrade L2100 SIMO to MIMO existing RRU License Only 3 Sector 7
11.1a Upgrade L2100 SIMO to MIMO use dismentled RRU 3 Sector 3
12.1 Upgrade L1800 SIMO to MIMO cascade GRFU/MRFU 3 Sector 889
12.1a Upgrade L1800 SIMO to MIMO use dismantled RRU1800 3 Sector 5
12.2 Upgrade L1800 SIMO to MIMO existing MRFUd license only 3 Sector 1
12.2a Upgrade L1800 SIMO to MIMO existingRRU license only 3 Sector 3
12.3 Upgrade L1800 SIMO to MIMO cascade GRFU/MRFU 2 sector 2
13.1 Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & New L21 SISO 3 sector 1
13.2 Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & New L21 SISO 4 sector 2
13.3 Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & New L21 SISO 5 sector 7
13.4 Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & New L21 SISO 6 sector 1
14.1 Upgrade L18 SIMO to MIMO existing RRU & New L21 SIMO existing RRU 3 sector 1
15.1 Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & L21 SISO to MIMO cascade WRFU 3 sector 76
15.2 Upgrade L18 SIMO to MIMO new RRU & L21 SISO to MIMO cascade WRFU 3 sector 226
15.2a Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO cascade WRFU 3 sector 135
15.2b Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO add dismantled RRU2100 3 sector 64
15.3a Upgrade L18 SIMO to MIMO existing RRU license only & L21 SISO to MIMO cascade WRFU 3 sector 3
15.3b Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & L21 SISO to MIMO existing RRU license only 3 sector 1
15.3c Upgrade L18 SIMO to MIMO existing RRU license only & L21 SISO to MIMO existing RRU license only 3 sector 1

15.4 Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO add dismantled RRU2100 3 sector 26
15.5a Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO cascade WRFU 4 sector 4
15.6a Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO cascade WRFU 5 sector 14
15.7a Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO cascade WRFU 6 sector 4
16.1a Upgrade L18 SIMO to MIMO existing RRU license only & L21 MIMO existing RRU license 3 sector 1
16.1b Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & L21 MIMO cascade WRFU 3 sector 7
16.2a Upgrade L18 SIMO to MIMO add new RRU & L21 MIMO new RRU 3 sector (3G reduce to 3 sector) 21
Wireless SOW- 3779 sites(76 Scenarios )
Scenario Site Qty
17.1 Upgrade L18 SIMO use dismantled RRU license only & L21 SIMO to MIMO existing RRU license 3 sector 4
2.4 Upgrade L1800 1T3S to 2T6S & Upgrade L2100 SISO to 2T6S 11
2.5 Upgrade L1800 1T3S to 2T6S & Upgrade L2100 2T3S to 2T6S 1
2.6 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SIMO to 2T6S 1
2.7 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SISO to 2T6S 63
2.8 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 2T3S to 2T6S 82
3.2 Add L2100 SISO WRFU 3 Sector 51
3.2a Add L2100 SISO WRFU 3 Sector (with UBBP) 2
3.2a.1 Add L2100 SISO WRFU 3 Sector (add dismantled BBP) 2
3.2b Add L2100 SISO WRFU 2 Sector 1
3.3 Add L2100 SISO RRU 3 Sector 3
3.4 Add L2100 SISO WRFU 4 Sector 76
3.5 Add L2100 SISO WRFU 5 Sector 64
3.6 Add L2100 SISO WRFU 6 Sector 18
4.2 Add L2100 SISO WRFU 3 Sector (Existing L18 MIMO) 19
4.2a Add L2100 SISO WRFU 1 Sector (Existing L18 MIMO) 1
4.2b Add L2100 SISO WRFU 3 Sector (with UBBP) (Existing L18 MIMO) 2
4.2b.1 Add L2100 SISO WRFU 3 Sector (add dismantled BBP) (Existing L18 MIMO) 1
4.3 Add L2100 SISO RRU 3 Sector (Existing L18 MIMO) 6
4.4 Add L2100 SISO WRFU 4 Sector (Existing L18 MIMO) 47
4.4b Add L2100 SISO RRU 4 Sector (Existing L18 MIMO) 1
4.5 Add L2100 SISO WRFU 5 Sector (Existing L18 MIMO) 59
4.6 Add L2100 SISO WRFU 6 Sector (Existing L18 MIMO) 37
5.1 Add L2100 SIMO RRU License only 13
5.2 Add L2100 SIMO 3 Sector New RRU 20
5.3 Add L2100 SIMO 3 Sector Cascade WRFU 1
5.4 Add L2100 SIMO 5 Sector New RRU 1
6.1 Add L2100 SIMO RRU License only (Existing L18 MIMO) 54
6.2 Add L2100 SIMO cascade WRFU only 4 sector (Existing L18 MIMO) 2
7.1 Add L2100 MIMO 3 Sector Cascade WRFU 9
7.1a Add L2100 MIMO add new RRU 3 Sector 91
7.1b Add L2100 MIMO 3 Sector Cascade WRFU (add UBBP) 1
8.1 Add L1800 SIMO 3 Sector New RRU 267
8.1a Add L1800 SIMO 3 Sector use dismantled RRU 62
8.2 Add L1800 SIMO 3 sector on existing GRFU/MRFU 1
8.3 Add L1800 SIMO 2 Sector New RRU 1
9.1 Add L1800 MIMO 3 Sector add dismantled RRU 9
Scenario 1.1 Upgrade L1800 1T3S to 2T6S & Add New L2100 1T6S

RRU Dual Band


4-P Antenna
2-P Antenna 4T4R

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU Combiner TCU


SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RFU RFU
PDU PDU
FANc

UBBPe4

FANc
UPEUd

UBBPd4

UPEUd
UBBPd4
UBBPe4 UMPTb1 UBBPe4 UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D

Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)


GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

Install New 3 RF Antenna Swap Existing Antenna


Dismantle GRFU/MRFU/WRFU board, Packing and Deliver
to WH
BOTTOM OF RACK BOTTOM OF RACK
Install dummy panel in empty slot
Scenario 1.2 Upgrade L1800 2T3S to 2T6S & Add New L2100 1T6S
1st Condition:Existing RFU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU Combiner TCU


SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RFU RFU
PDU PDU
FANc

UBBPe4

FANc
UPEUd

UBBPe4

UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D

Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)


GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

Install New 3 RF Antenna Swap Existing Antenna(if any)


Dismantle GRFU/MRFU/WRFU board, Packing and Deliver
to WH
BOTTOM OF RACK BOTTOM OF RACK
Install dummy panel in empty slot
Scenario 1.2 Upgrade L1800 2T3S to 2T6S & Add New L2100 1T6S
2nd Condition:Existing RRU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R
RRU2100
BTS3900A Ver. B AC type BTS3900A Ver. B AC type
RRU1800
TCU Combiner TCU
SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RRU RRU
PDU PDU

UBBPe4
FANc

FANc
UPEUd

UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 1.4 Upgrade L1800 1T3S to 2T6S & Upgrade L2100 (SISO) 1T3S to 1T6S
1st Condition:Existing RFU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU Combiner TCU


SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RFU RFU
PDU PDU
FANc

UBBPe4

FANc
UPEUd

UBBPe4

UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D

Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)


GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

Install New 3 RF Antenna Swap Existing Antenna(if any)


Dismantle GRFU/MRFU/WRFU board, Packing and Deliver
to WH
BOTTOM OF RACK BOTTOM OF RACK
Install dummy panel in empty slot
Scenario 1.4 Upgrade L1800 1T3S to 2T6S & Upgrade L2100 (SISO) 1T3S to 1T6S
2nd Condition:Existing RRU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R
RRU2100
BTS3900A Ver. B AC type BTS3900A Ver. B AC type
RRU1800
TCU Combiner TCU
SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RRU RRU
PDU PDU

UBBPe4
FANc

FANc
UPEUd

UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 1.6 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SIMO to 1T6S
1st Condition:Existing RFU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU Combiner TCU


SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RFU RFU
PDU PDU
FANc

UBBPe4

FANc
UPEUd

UBBPe4

UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D

Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)


GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

Install New 3 RF Antenna Swap Existing Antenna(if any)


Dismantle GRFU/MRFU/WRFU board, Packing and Deliver
to WH
BOTTOM OF RACK BOTTOM OF RACK
Install dummy panel in empty slot
Scenario 1.6 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SIMO to 1T6S
2nd Condition:Existing RRU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R
RRU2100
BTS3900A Ver. B AC type BTS3900A Ver. B AC type
RRU1800
TCU Combiner TCU
SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RRU RRU
PDU PDU

UBBPe4
FANc

FANc
UPEUd

UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 1.7 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SISO to 1T6S
1st Condition:Existing RFU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU Combiner TCU


SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RFU RFU
PDU PDU
FANc

UBBPe4

FANc
UPEUd

UBBPe4

UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D

Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)


GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

Install New 3 RF Antenna Swap Existing Antenna(if any)


Dismantle GRFU/MRFU/WRFU board, Packing and Deliver
to WH
BOTTOM OF RACK BOTTOM OF RACK
Install dummy panel in empty slot
Scenario 1.7 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SISO to 1T6S
2nd Condition:Existing RRU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R
RRU2100
BTS3900A Ver. B AC type BTS3900A Ver. B AC type
RRU1800
TCU Combiner TCU
SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RRU RRU
PDU PDU

UBBPe4
FANc

FANc
UPEUd

UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 1.8 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 MIMO to 1T6S
1st Condition:Existing RFU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU Combiner TCU


SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RFU RFU
PDU PDU
FANc

UBBPe4

FANc
UPEUd

UBBPe4

UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D

Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)


GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

Install New 3 RF Antenna Swap Existing Antenna(if any)


Dismantle GRFU/MRFU/WRFU board, Packing and Deliver
to WH
BOTTOM OF RACK BOTTOM OF RACK
Install dummy panel in empty slot
Scenario 1.8 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 MIMO to 1T6S
2nd Condition:Existing RRU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R
RRU2100
BTS3900A Ver. B AC type BTS3900A Ver. B AC type
RRU1800
TCU Combiner TCU
SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RRU RRU
PDU PDU

UBBPe4
FANc

FANc
UPEUd

UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 2.4 Upgrade L1800 1T3S to 2T6S & Upgrade L2100 SISO to 2T6S

RRU Dual Band


4-P Antenna
2-P Antenna 4T4R

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU Combiner TCU


SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RFU RFU
PDU PDU
FANc

UBBPe4

FANc
UPEUd

UBBPe4

UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D

Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)


GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

Install New 3 RF Antenna Swap Existing Antenna(if any)


Dismantle GRFU/MRFU/WRFU board, Packing and Deliver
to WH
BOTTOM OF RACK BOTTOM OF RACK
Install dummy panel in empty slot
Scenario 2.5 Upgrade L1800 1T3S to 2T6S & Upgrade L2100 2T3S to 2T6S

RRU Dual Band


4-P Antenna
2-P Antenna 4T4R

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU Combiner TCU


SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
PDU
RFU RFU 630139
PDU
FANc

UBBPe4

FANc
UPEUd

UBBPe4

UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D

Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)


GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

Install New 3 RF Antenna Swap Existing Antenna(if any)


Dismantle GRFU/MRFU/WRFU board, Packing and Deliver
to WH
BOTTOM OF RACK BOTTOM OF RACK
Install dummy panel in empty slot
Scenario 2.6 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SIMO to 2T6S

RRU Dual Band


4-P Antenna
2-P Antenna 4T4R
RRU2100
BTS3900A Ver. B AC type BTS3900A Ver. B AC type
RRU1800
TCU Combiner TCU
SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RRU RRU
PDU PDU

UBBPe4
FANc

FANc
UPEUd

UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 2.7 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SISO to 2T6S
1st Condition:Existing RFU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU Combiner TCU


SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RFU RFU
PDU PDU
FANc

UBBPe4

FANc
UPEUd

UBBPe4

UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D

Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)


GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

Install New 3 RF Antenna Swap Existing Antenna(if any)


Dismantle GRFU/MRFU/WRFU board, Packing and Deliver
to WH
BOTTOM OF RACK BOTTOM OF RACK
Install dummy panel in empty slot
Scenario 2.7 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 SISO to 2T6S
2nd Condition:Existing RRU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R
RRU2100
BTS3900A Ver. B AC type BTS3900A Ver. B AC type
RRU1800
TCU Combiner TCU
SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RRU RRU
PDU PDU

UBBPe4
FANc

FANc
UPEUd

UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 2.8 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 2T3S to 2T6S
1st Condition:Existing RFU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU Combiner TCU


SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RFU RFU
PDU PDU
FANc

UBBPe4

FANc
UPEUd

UBBPe4

UPEUd
UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new DCDU16D ( Power Booster )
Add new 1 pcs UBBPe4 at slot 1 DCDU16D

Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)


GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

Install New 3 RF Antenna Swap Existing Antenna(if any)


Dismantle GRFU/MRFU/WRFU board, Packing and Deliver
to WH
BOTTOM OF RACK BOTTOM OF RACK
Install dummy panel in empty slot
Scenario 2.8 Upgrade L1800 2T3S to 2T6S & Upgrade L2100 2T3S to 2T6S
2nd Condition:Existing RRU
RRU Dual Band
4-P Antenna
2-P Antenna 4T4R
RRU2100
BTS3900A Ver. B AC type BTS3900A Ver. B AC type
RRU1800
TCU Combiner TCU
SLPU SLPU
PMU PSU PSU PSU 4T4R PMU PSU PSU PSU
1T2R 1T2R RRU Dual Band
RRU RRU
PDU PDU

UBBPe4
FANc

FANc
UPEUd

UPEUd
UBBPe4 UBBPe4
WBBP UMPTb1 WBBP UMPTb1
Install 1 new EPU ( Power Booster )
DCDU16D
Add new 1 pcs UBBPe4 at slot 1
Install New 3 pcs New RRU5502 connect to UBBPe4 (port 0,1,2)
Install New 3 RF Antenna Swap Existing Antenna(if any)
Dismantle RRU board, Packing and Deliver
BOTTOM OF RACK to WH BOTTOM OF RACK
Scenario 3.2 Add L2100 SISO WRFU 3 Sector

2-P Antenna 2-P Antenna

BTS3900A Ver. B AC type


BTS3900A Ver. B AC type
TCU
TCU Combiner
SLPU
Combiner
SLPU PMU PSU PSU PSU
PMU PSU PSU PSU
1T2R 1T2R 1T2R 1T2R PDU
RFU RFU RFU RFU
PDU
WBBP

FANc

UPEUd
WBBP
FANc

UPEUd

UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add 2 pcs WRFU 80W(if any)
Dismantle WRFU 40W board, Packing and Deliver

GL1800 MRFU

GL1800 MRFU

GL1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
to WH(if any)
GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

80W
80w
BOTTOM OF RACK
BOTTOM OF RACK
Scenario 3.2a Add L2100 SISO WRFU 3 Sector (with UBBP)

2-P Antenna 2-P Antenna

BTS3900A Ver. B AC type


BTS3900A Ver. B AC type
TCU
TCU Combiner
SLPU
Combiner
SLPU PMU PSU PSU PSU
PMU PSU PSU PSU
1T2R 1T2R 1T2R 1T2R PDU
RFU RFU RFU RFU
PDU
WBBP

FANc

UPEUd
WBBP UBBPe4
FANc

UPEUd

UBBPd UMPTb1
UBBPd UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)

GL1800 MRFU

GL1800 MRFU

GL1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
Move SFP cable to UBBPe4 (1800M to port 0,1,2,
GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

2100M to port 3,4,5) (if any)

BOTTOM OF RACK
BOTTOM OF RACK
Scenario 3.2a.1 Add L2100 SISO WRFU 3 Sector (add dismantled BBP)

2-P Antenna 2-P Antenna

BTS3900A Ver. B AC type


BTS3900A Ver. B AC type
TCU
TCU Combiner
SLPU
Combiner
SLPU PMU PSU PSU PSU
PMU PSU PSU PSU
1T2R 1T2R 1T2R 1T2R PDU
RFU RFU RFU RFU
PDU
WBBP

FANc

UPEUd
WBBP UBBP
FANc

UPEUd

UBBPd UMPTb1
UBBPd UMPTb1 Add new 1 pcs UBBP/LBBP at slot 2 or other idle slot(slot 0 to 3)
Move L2100 SFP cable to UBBP/LBBP (port 0,1,2)

GL1800 MRFU

GL1800 MRFU

GL1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

BOTTOM OF RACK
BOTTOM OF RACK
Scenario 3.4 Add L2100 SISO WRFU 4 Sector

2-P Antenna 2-P Antenna

BTS3900A Ver. B AC type


BTS3900A Ver. B AC type
TCU
TCU Combiner
SLPU
Combiner
SLPU PMU PSU PSU PSU
PMU PSU PSU PSU
1T2R 1T2R 1T2R 1T2R PDU
RFU RFU RFU RFU
PDU
WBBP

FANc

UPEUd
WBBP UBBPe4
FANc

UPEUd

UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)

GL1800 MRFU

GL1800 MRFU

GL1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

BOTTOM OF RACK
BOTTOM OF RACK
Scenario 3.5 Add L2100 SISO WRFU 5 Sector

2-P Antenna 2-P Antenna

BTS3900A Ver. B AC type


BTS3900A Ver. B AC type
TCU
TCU Combiner
SLPU
Combiner
SLPU PMU PSU PSU PSU
PMU PSU PSU PSU
1T2R 1T2R 1T2R 1T2R PDU
RFU RFU RFU RFU
PDU
WBBP

FANc

UPEUd
WBBP UBBPe4
FANc

UPEUd

UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)

GL1800 MRFU

GL1800 MRFU

GL1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

BOTTOM OF RACK
BOTTOM OF RACK
Scenario 3.6 Add L2100 SISO WRFU 6 Sector

2-P Antenna 2-P Antenna

BTS3900A Ver. B AC type


BTS3900A Ver. B AC type
TCU
TCU Combiner
SLPU
Combiner
SLPU PMU PSU PSU PSU
PMU PSU PSU PSU
1T2R 1T2R 1T2R 1T2R PDU
RFU RFU RFU RFU
PDU
WBBP

FANc

UPEUd
WBBP UBBPe4
FANc

UPEUd

UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)

GL1800 MRFU

GL1800 MRFU

GL1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

BOTTOM OF RACK
BOTTOM OF RACK
Scenario 4.2b Add L2100 SISO WRFU 3 Sector (with UBBP) (Existing L18 MIMO)

2-P Antenna 2-P Antenna

BTS3900A Ver. B AC type


BTS3900A Ver. B AC type
TCU
TCU Combiner
SLPU
Combiner
SLPU PMU PSU PSU PSU
PMU PSU PSU PSU
1T2R 1T2R 1T2R 1T2R PDU
RFU RFU RFU RFU
PDU
WBBP

FANc

UPEUd
WBBP UBBPe4
FANc

UPEUd

UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)

GL1800 MRFU

GL1800 MRFU

GL1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

BOTTOM OF RACK
BOTTOM OF RACK
Scenario 4.2b.1 Add L2100 SISO WRFU 3 Sector (add dismantled BBP) (Existing L18 MIMO)

2-P Antenna 2-P Antenna

BTS3900A Ver. B AC type


BTS3900A Ver. B AC type
TCU
TCU Combiner
SLPU
Combiner
SLPU PMU PSU PSU PSU
PMU PSU PSU PSU
1T2R 1T2R 1T2R 1T2R PDU
RFU RFU RFU RFU
PDU
WBBP

FANc

UPEUd
WBBP UBBPd4
FANc

UPEUd

UBBPd4 UMPTb1
UBBPd4 UMPTb1 Add new 1 pcs UBBPd4 at slot 2 or other idle slot(slot 0
to 3)

GL1800 MRFU

GL1800 MRFU

GL1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

BOTTOM OF RACK
BOTTOM OF RACK
Scenario 4.4 Add L2100 SISO WRFU 4 Sector (Existing L18 MIMO)

2-P Antenna 2-P Antenna

BTS3900A Ver. B AC type


BTS3900A Ver. B AC type
TCU
TCU Combiner
SLPU
Combiner
SLPU PMU PSU PSU PSU
PMU PSU PSU PSU
1T2R 1T2R 1T2R 1T2R PDU
RFU RFU RFU RFU
PDU
WBBP

FANc

UPEUd
WBBP UBBPe4
FANc

UPEUd

UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)

GL1800 MRFU

GL1800 MRFU

GL1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

BOTTOM OF RACK
BOTTOM OF RACK
Scenario 4.4b Add L2100 SISO RRU 4 Sector (Existing L18 MIMO)

2-P Antenna 2-P Antenna

BTS3900A Ver. B AC type


BTS3900A Ver. B AC type
TCU
TCU Combiner
SLPU
Combiner
SLPU PMU PSU PSU PSU
PMU PSU PSU PSU
2T2R 1T2R 2T2R 1T2R PDU
RRU RFU RFU RFU
PDU
WBBP

FANc

UPEUd
WBBP UBBPe4
FANc

UPEUd

UBBPe4 UMPTb1
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0
to 3)

BOTTOM OF RACK
BOTTOM OF RACK
Scenario 4.5 Add L2100 SISO WRFU 5 Sector (Existing L18 MIMO)

2-P Antenna 2-P Antenna

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU Combiner TCU


Combiner
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU
1T2R 1T2R 1T2R 1T2R
RFU RFU RFU RFU
PDU PDU

WBBP WBBP

FANc
FANc

UPEUd
UPEUd

UBBPe4
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0 UBBPe4 UMPTb1

to 3)

GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
GL1800 MRFU

GL1800 MRFU

GL1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
BOTTOM OF RACK BOTTOM OF RACK BOTTOM OF RACK
Scenario 4.6 Add L2100 SISO WRFU 6 Sector (Existing L18 MIMO)

2-P Antenna 2-P Antenna

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU Combiner TCU


Combiner
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU
1T2R 1T2R 1T2R 1T2R
RFU RFU RFU RFU
PDU PDU

WBBP WBBP

FANc
FANc

UPEUd
UPEUd

UBBPe4
UBBPe4 UMPTb1 Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0 UBBPe4 UMPTb1

to 3)

GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
GL1800 MRFU

GL1800 MRFU

GL1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
BOTTOM OF RACK BOTTOM OF RACK BOTTOM OF RACK
Scenario 5.2 Add L2100 SIMO 3 Sector New RRU

L2100 RRU3959a
BTS3900A
BTS3900A L1800 RRU3959a 2T2R
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

FANc
WBBP
Install new 3 pcs L2100 RRU3959 and
FANc

WBBP

UPEUd
UPEUd

connect to UBBPe4 (port 3,4,5) UBBPe4 UMPT


UBBPe4 UMPT

DCDU
DCDU
FMU
FMU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 34


Scenario 5.3 Add L2100 SIMO 3 Sector Cascade WRFU

BTS3900A BTS3900A
L1800 RRU3959a L1800 RRU3959a
TCU 2T2R TCU 2T2R
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU

PDU PDU

add new 4 pcs WRFU(80W),then Casecade RFU for each sector


FANc

FANc
UPEUd

UPEUd
UBBPe4 UBBPe4
WBBP UMPT WBBP UMPT

DCDU DCDU
FMU FMU
U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 35


Scenario 5.4 Add L2100 SIMO 5 Sector New RRU

BTS3900A
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R L2100 RRU3959a
SLPU
SLPU 2T2R
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

FANc
WBBP
Add new 1 pcs UBBPe4 at slot 2
FANc

WBBP

UPEUd
UBBPe4
UPEUd

Install new 5 pcs L2100 RRU3959 and UBBPe4 UMPT


UBBPe4 UMPT
connect to UBBPe4 (port 1,2,3,4,5)
DCDU
DCDU
FMU
FMU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 36


Scenario 6.2 Add L2100 SIMO cascade WRFU only 4 sector (Existing L18 MIMO)

BTS3900A BTS3900A
L1800 RRU3959a L1800 RRU3959a
TCU 2T2R TCU 2T2R
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU

PDU PDU

Add new RFC Cabinet


FANc

FANc
UBBPe4
UPEUd

UPEUd
UBBPe4 UBBPe4
Add new 1 pcs UBBPe4 at slot 2 or other idle slot(slot 0 to 3)
WBBP UMPT WBBP UMPT
add new 4 or 6 pcs WRFU(80W),then Casecade RFU for each sector
Dismantle WRFU board, Packing, and Deliver to WH
DCDU DCDU
FMU FMU
U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
BOTTOM OF RACK BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 37


Scenario:7.1 Add L2100 MIMO 3 Sector Cascade WRFU

BTS3900A
BTS3900A

TCU
TCU
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

FANc
Add new RFC Cabinet (if any)
FANc

UPEUd
UBBPe4
UPEUd

UBBPe4
Add new 3 or 4 or 6 pcs WRFU,then Casecade RFU for WBBP UMPT
WBBP UMPT
each sector
DCDU DCDU
DCDU
FMU
FMU

G1800 MRFU

G1800 MRFU

G1800 MRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 MRFU

G1800 MRFU

G1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

BOTTOM OF RACK BOTTOM OF RACK


BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 38


Scenario 7.1a Add L2100 MIMO add new RRU 3 Sector

L2100 RRU3959a
BTS3900A
BTS3900A 2T2R
TCU
TCU
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

FANc
Install new 3 pcs L2100 RRU3959 and
FANc

UPEUd
UBBPe4
UPEUd

UBBPe4
connect to UBBPe4 (port 3,4,5) WBBP UMPT
WBBP UMPT
Dismantle WRFU board, Packing, and Deliver to WH
DCDU
DCDU
FMU
FMU

G1800 MRFU

G1800 MRFU

G1800 MRFU
G1800 MRFU

G1800 MRFU

G1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 39


Scenario 7.1b Add L2100 MIMO 3 Sector Cascade WRFU (add UBBP)

BTS3900A
BTS3900A

TCU
TCU
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

FANc
UBBPe4
Add new RFC Cabinet
FANc

UPEUd
UBBPe4
UPEUd

UBBPe4
Add 1 pcs new UBBPe4 in slot 1 WBBP UMPT
WBBP UMPT
Add new 3 pcs WRFU,then Casecade RFU for each sector
DCDU DCDU
DCDU
FMU
FMU

G1800 MRFU

G1800 MRFU

G1800 MRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU
G1800 MRFU

G1800 MRFU

G1800 MRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

BOTTOM OF RACK BOTTOM OF RACK


BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 40


Scenario 8.1 Add L1800 SIMO 3 Sector New RRU

L1800 RRU3959a
BTS3900A
BTS3900A L2100 RRU3959a 2T2R
L2100 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

FANc
UBBPe4
Install new 3 pcs L1800 RRU3959 and
FANc

UPEUd
UBBPe4
UPEUd

UBBPe4
connect to UBBPe4 (port 0,1,2) WBBP UMPT
WBBP UMPT
Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3)
DCDU
DCDU
FMU
FMU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 41


Scenario 8.1a Add L1800 SIMO 3 Sector use dismantled RRU

L1800 RRU3959a
BTS3900A
BTS3900A L2100 RRU3959a 2T2R
L2100 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

FANc
UBBPe4
Install new 3 pcs L1800 RRU3959(from H3I) and
FANc

UPEUd
UBBPe4
UPEUd

UBBPe4
connect to UBBPe4 (port 0,1,2) WBBP UMPT
WBBP UMPT
Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3)
DCDU
DCDU
FMU
FMU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 42


Scenario 8.2 Add L1800 SIMO 3 sector on existing GRFU/MRFU

BTS3900A
BTS3900A L2100 RRU3959a
L2100 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

FANc
UBBPe4
Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3)
FANc

UPEUd
UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT

DCDU
DCDU
FMU
FMU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 43


Scenario 8.3 Add L1800 SIMO 2 Sector New RRU L2100 RRU3959a
2T2R

L1800 RRU3959a
BTS3900A
BTS3900A 2T2R
L2100 RRU3959a TCU
TCU 2T2R SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
UBBPe4 UBBPe4
UBBPe4

FANc
UBBPe4
Install new 2 pcs L1800 RRU3959(from H3I) and
FANc

UBBPe4

UPEUd
UBBPe4
UPEUd

UBBPe4
connect to UBBPe4 (port 0,1,2) UBBPe4 UMPT
UBBPe4 UMPT
Add UBBPe4 in slot 4
DCDU
DCDU
FMU
FMU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 44


Scenario 9.1 Add L1800 MIMO 3 Sector add dismantled RRU

L1800 RRU3959a
BTS3900A
BTS3900A L2100 RRU3959a 2T2R
L2100 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

FANc
UBBPe4
Install new 3 pcs L1800 RRU3959(from H3I) and
FANc

UPEUd
UBBPe4
UPEUd

UBBPe4
connect to UBBPe4 (port 0,1,2) WBBP UMPT
WBBP UMPT
Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3)
DCDU
DCDU
FMU
FMU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 45


Scenario 10.1 Upgrade L2100 SISO to MIMO cascade WRFU 2 Sector

BTS3900A
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

Install new 2 pcs WRFU,then Casecade

FANc
FANc

UPEUd
RFU for each sector UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT

DCDU DCDU
DCDU
FMU
FMU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU
U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK BOTTOM OF RACK


BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 46


Scenario 10.2 Upgrade L2100 SISO to MIMO cascade WRFU 3 Sector

BTS3900A
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

Install new 2 or 3 or 4 or 5 pcs WRFU,then Casecade

FANc
FANc

UPEUd
RFU for each sector UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT  Add new RFC Cabinet(if any)

DCDU DCDU
DCDU
FMU
FMU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK BOTTOM OF RACK


BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 47


Scenario 10.3 Upgrade L2100 SISO to MIMO add dismantled RRU2100 3 Sector

L2100 RRU3959a
BTS3900A
BTS3900A L1800 RRU3959a 2T2R
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

Install new 3 pcs L2100 RRU3959 and

FANc
FANc

UPEUd
connect to UBBPe4 (port 3,4,5) UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT Dismantle WRFU board, Packing, and Deliver to WH

DCDU
DCDU
FMU
FMU

G1800 GRFU

G1800 GRFU

G1800 GRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 48


Scenario 10.3a Upgrade L2100 SISO to MIMO add New RRU 3 Sector

L2100 RRU3959a
BTS3900A
BTS3900A L1800 RRU3959a 2T2R
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

Install new 3 pcs L2100 RRU3959(from H3I) and

FANc
FANc

UPEUd
connect to UBBPe4 (port 3,4,5) UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT Dismantle WRFU board, Packing, and Deliver to WH

DCDU
DCDU
FMU
FMU

G1800 GRFU

G1800 GRFU

G1800 GRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 49


Scenario 10.4a Upgrade L2100 SISO to MIMO add New RRU 4 Sector

L2100 RRU3959a
BTS3900A 2T2R
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

Install new 4 pcs L2100 RRU3959(from H3I) and

FANc
FANc

UPEUd
connect to UBBPe4 (port 2,3,4,5) UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT Dismantle WRFU board, Packing, and Deliver to WH

DCDU
DCDU
FMU
FMU

G1800 GRFU

G1800 GRFU

G1800 GRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 50


Scenario 10.5a Upgrade L2100 SISO to MIMO add New RRU 5 Sector

L2100 RRU3959a
BTS3900A 2T2R
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

Install new 5 pcs L2100 RRU3959(from H3I) and

FANc
UBBPe4
FANc

UPEUd
connect to UBBPe4 (port 2,3,4,5) UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT √ Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3)

Dismantle WRFU board, Packing, and Deliver to WH DCDU


DCDU
FMU
FMU

G1800 GRFU

G1800 GRFU

G1800 GRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 51


Scenario 10.6a Upgrade L2100 SISO to MIMO add New RRU 6 Sector

L2100 RRU3959a
BTS3900A 2T2R
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

Install new 6 pcs L2100 RRU3959(from H3I) and

FANc
UBBPe4
FANc

UPEUd
connect to UBBPe4 (port 2,3,4,5) UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT √ Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3)

Dismantle WRFU board, Packing, and Deliver to WH DCDU


DCDU
FMU
FMU

G1800 GRFU

G1800 GRFU

G1800 GRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 52


Scenario 11.1a Upgrade L2100 SIMO to MIMO use dismentled RRU 3 Sector

L2100 RRU3959a
BTS3900A
BTS3900A L1800 RRU3959a 2T2R
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

Install new 3 pcs L2100 RRU3959(from H3I) and

FANc
FANc

UPEUd
connect to UBBPe4 (port 3,4,5) UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT Dismantle WRFU board, Packing, and Deliver to WH

DCDU
DCDU
FMU
FMU
U2100 WRFU

U2100 WRFU

U2100 WRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 53


Scenario 12.1 Upgrade L1800 SIMO to MIMO cascade GRFU/MRFU 3 Sector

BTS3900A
BTS3900A

TCU
TCU 2-P Antenna 2-P Antenna SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
Combiner Combiner

FANc
FANc

UPEUd
UBBPe4
UPEUd

UBBPe4
1T2R 1T2R WBBP UMPT
WBBP UMPT 1T2R 1T2R 1T2R
RFU RFU RFU RFU RFU

DCDU DCDU
DCDU
FMU
FMU

U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

Install new 3 or 4 pcs GRFU/MRFU,then Casecade


RFU for each sector
 Add new RFC Cabinet(if any)
BOTTOM OF RACK BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 54


Scenario 12.1a Upgrade L1800 SIMO to MIMO use dismantled RRU1800 3 Sector

BTS3900A
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 1T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

Install new 3 pcs L1800 RRU3959 2T2R and

FANc
FANc

UPEUd
connect to UBBPe4 (port 0,1,2) UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT Dismantle L1800M 1T2R RRU, Packing, and Deliver to WH

DCDU
DCDU
FMU
FMU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 55


Scenario 12.3 Upgrade L1800 SIMO to MIMO cascade GRFU/MRFU 2 sector

BTS3900A
BTS3900A
TCU
TCU 2-P Antenna 2-P Antenna SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU
Combiner Combiner

FANc
FANc

UPEUd
UBBPe4
UPEUd

UBBPe4
1T2R 1T2R WBBP UMPT
WBBP UMPT 1T2R 1T2R 1T2R
RFU RFU RFU RFU RFU

DCDU DCDU
DCDU DCDU Install new 2 pcs GRFU/MRFU,then FMU
FMU
Casecade

U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU
G1800 GRFU

G1800 GRFU
G1800 GRFU

G1800 GRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

RFU for each sector


 Add new RFC Cabinet(if any)

BOTTOM OF RACK BOTTOM OF RACK


BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 56


Scenario 13.1 Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & New L21 SISO 3 sector

BTS3900A 2-P Antenna 2-P Antenna


BTS3900A

TCU TCU
SLPU SLPU

PMU PSU PSU PSU PMU PSU PSU PSU


Combiner Combiner
PDU PDU

1T2R 1T2R 1T2R 1T2R 1T2R

FANc
FANc

RFU RFU RFU RFU RFU

UPEUd
UBBPe4
UPEUd

UBBPe4
WBBP UMPT WBBP UMPT

DCDU DCDU DCDU


DCDU
FMU FMU
 Add new RFC Cabinet

U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

Install new 3 pcs GRFU/MRFU,then


Casecade RFU for each sector

BOTTOM OF RACK BOTTOM OF RACK


BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 57


Scenario 13.2 Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & New L21 SISO 4 sector

BTS3900A 2-P Antenna 2-P Antenna


BTS3900A

TCU TCU
SLPU SLPU

PMU PSU PSU PSU PMU PSU PSU PSU


Combiner Combiner
PDU PDU

1T2R 1T2R 1T2R 1T2R 1T2R

FANc
FANc

RFU RFU RFU RFU RFU

UPEUd
UBBPe4
UPEUd

UBBPe4
WBBP UMPT WBBP UMPT

DCDU DCDU DCDU


DCDU
FMU FMU
 Add new RFC Cabinet

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

Install new 2 or 3 pcs GRFU/MRFU,then


Casecade RFU for each sector

BOTTOM OF RACK BOTTOM OF RACK


BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 58


Scenario 13.3 Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & New L21 SISO 5 sector

BTS3900A 2-P Antenna 2-P Antenna


BTS3900A

TCU TCU
SLPU SLPU

PMU PSU PSU PSU PMU PSU PSU PSU


Combiner Combiner
PDU PDU

1T2R 1T2R 1T2R 1T2R 1T2R

FANc
UBBPe4
FANc

RFU RFU RFU RFU RFU

UPEUd
UBBPe4
UPEUd

UBBPe4
WBBP UMPT WBBP UMPT

DCDU DCDU DCDU


DCDU
FMU FMU
 Add UBBPe4 in slot 1 or

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

other idle slot(slot 0 to 3)


Install new 3 pcs GRFU/MRFU,then
Casecade RFU for each sector
BOTTOM OF RACK BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 59


Scenario 13.4 Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & New L21 SISO 6 sector

BTS3900A 2-P Antenna 2-P Antenna


BTS3900A

TCU TCU
SLPU SLPU

PMU PSU PSU PSU PMU PSU PSU PSU


Combiner Combiner
PDU PDU

1T2R 1T2R 1T2R 1T2R 1T2R

FANc
UBBPe4
FANc

RFU RFU RFU RFU RFU

UPEUd
UBBPe4
UPEUd

UBBPe4
WBBP UMPT WBBP UMPT

DCDU DCDU DCDU


DCDU
FMU FMU
 Add UBBPe4 in slot 1 or

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

other idle slot(slot 0 to 3)


Install new 3 pcs GRFU/MRFU,then
Casecade RFU for each sector
BOTTOM OF RACK BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 60


Scenario 14.1 Upgrade L18 SIMO to MIMO existing RRU & New L21 SIMO existing RRU 3 sector

BTS3900A 2-P Antenna BTS3900A


2-P Antenna

TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU
Combiner Combiner
PDU PDU

2T2R 1T2R 2T2R 1T2R


FANc

FANc
RRU RRU
UBBPe4
RRU RRU
UPEUd

UPEUd
UBBPe4 UBBPe4
WBBP UMPT WBBP UMPT

DCDU DCDU
FMU  Add UBBPe4 in slot 1 or other idle slot(slot 0 to 3) FMU

BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 61


Scenario 15.1 Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & L21 SISO to MIMO cascade WRFU 3 sector

BTS3900A 2-P Antenna 2-P Antenna


BTS3900A

TCU TCU
SLPU SLPU

PMU PSU PSU PSU PMU PSU PSU PSU


Combiner Combiner
PDU PDU

1T2R 1T2R 1T2R 1T2R 1T2R 1T2R

FANc
FANc

RFU RFU RFU RFU RFU RFU

UPEUd
UBBPe4
UPEUd

UBBPe4
WBBP UMPT WBBP UMPT
Add new RFC Cabinet(if any)

DCDU Move WRFU to new RFC Cabinet DCDU DCDU


FMU FMU
Install 3 pcs GRFU/MRFU,then

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

Casecade RFU for each sector


 Add new RFC Cabinet(if any)
Install 3 or 4(existing 2 Cabinet) or 5(existing 2 Cabinet)
pcs WRFU,then BOTTOM OF RACK BOTTOM OF RACK
BOTTOM OF RACK
Casecade RFU for each sector

HUAWEI TECHNOLOGIES CO., LTD. Page 62


Scenario 15.2 Upgrade L18 SIMO to MIMO new RRU & L21 SISO to MIMO cascade WRFU 3 sector

BTS3900A 2-P Antenna


BTS3900A
2-P Antenna L1800 RRU3959a
TCU 2T2R
TCU
SLPU SLPU

PMU PSU PSU PSU PMU PSU PSU PSU


Combiner
PDU
Combiner PDU

2T2R 1T2R 1T2R

FANc
FANc

1T2R 1T2R RRU RFU RFU

UPEUd
RFU RFU UBBPe4
UPEUd

UBBPe4
WBBP UMPT WBBP UMPT
√ Add 3 pcs L1800 new RRU
√ Dismantle GRFU/MRFU DCDU
DCDU
FMU √ Install Install 3 or 4 or 6 pcs WRFU,then FMU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100WRFU
Casecade RFU for each sector
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 63


Scenario 15.2a Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO cascade WRFU 3 sector

BTS3900A 2-P Antenna


BTS3900A
2-P Antenna L1800 RRU3959a
TCU 2T2R
TCU
SLPU SLPU

PMU PSU PSU PSU PMU PSU PSU PSU


Combiner
PDU
Combiner PDU

2T2R 1T2R 1T2R

FANc
FANc

1T2R 1T2R RRU RFU RFU

UPEUd
RFU RFU UBBPe4
UPEUd

UBBPe4
WBBP UMPT WBBP UMPT
√ Add 3 pcs L1800 RRU(from H3I)
√ Dismantle GRFU/MRFU DCDU
DCDU
FMU √ Install Install 3 or 4 or 5 or 6 pcs WRFU,then FMU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100WRFU
Casecade RFU for each sector
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 64


Scenario 15.2b Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO add dismantled RRU2100 3 sector

L1800 RRU3959a L2100 RRU3959a


BTS3900A 2T2R
BTS3900A 2-P Antenna 2-P Antenna 2T2R
TCU
TCU
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
Combiner Combiner
PDU
PDU

1T2R 1T2R 2T2R

FANc
2T2R
RFU
FANc

RFU RRU
RRU

UPEUd
UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT
√ Add 3 pcs L1800 and 3 pcs L2100 RRU(from H3I)
√ Dismantle GRFU/MRFU and WRFU DCDU
DCDU
FMU
FMU √ Connect L1800 RRU fiber to UBBPe4 (port 0,1,2),L2100 RRU
fiber to UBBPe4 (port 3,4,5)
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 65


Scenario 15.3a Upgrade L18 SIMO to MIMO existing RRU license only & L21 SISO to MIMO cascade WRFU 3 sector

BTS3900A
BTS3900A L1800 RRU3959a
L1800 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

Install new 3 pcs WRFU, then

FANc
FANc

UPEUd
Casecade RFU for each sector UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT

DCDU
DCDU
FMU
FMU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 66


Scenario 15.3b Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & L21 SISO to MIMO existing RRU license only 3 sector

BTS3900A
BTS3900A L2100 RRU3959a
L2100 RRU3959a
TCU 2T2R
TCU 2T2R
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

Install new 3 pcs GRFU/MRFU, then

FANc
FANc

UPEUd
Casecade RFU for each sector UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT

DCDU
DCDU
FMU
FMU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 67


Scenario 15.4 Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO add dismantled RRU2100 3 secto

L1800 RRU3959a L2100 RRU3959a


BTS3900A 2T2R
BTS3900A 2-P Antenna 2-P Antenna 2T2R
TCU
TCU
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
Combiner Combiner
PDU
PDU

1T2R 1T2R 2T2R

FANc
2T2R
RFU
FANc

RFU RRU
RRU

UPEUd
UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT
√ Add 3 pcs L1800 and 3 pcs L2100 RRU(from H3I)
√ Dismantle GRFU/MRFU and WRFU DCDU
DCDU
FMU
FMU √ Connect L1800 RRU fiber to UBBPe4 (port 0,1,2),L2100 RRU
fiber to UBBPe4 (port 3,4,5)
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 68


Scenario 15.5a Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO cascade WRFU 4 sector
2-P Antenna
2-P Antenna

BTS3900A BTS3900A
L1800 RRU3959a
TCU 2T2R
TCU Combiner
SLPU Combiner SLPU

PMU PSU PSU PSU PMU PSU PSU PSU


2T2R 1T2R 1T2R
1T2R 1T2R RRU RFU RFU PDU
PDU RFU RFU
√ Add 3 pcs L1800 RRU(from H3I)

FANc
FANc

√ Dismantle GRFU/MRFU

UPEUd
UBBPe4
UPEUd

UBBPe4
√ Install Install 4 pcs WRFU,then WBBP UMPT
WBBP UMPT
Casecade RFU for each sector
Dismantle GRFU/MRFU, Packing, and Deliver to WH DCDU DCDU
DCDU DCDU
FMU FMU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100WRFU
U2100 WRFU
U2100 WRFU

U2100 WRFU
U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK BOTTOM OF RACK BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 69


15.6a Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO cascade WRFU 5 sector
2-P Antenna
2-P Antenna

BTS3900A BTS3900A
L1800 RRU3959a
TCU 2T2R
TCU Combiner
SLPU Combiner SLPU

PMU PSU PSU PSU PMU PSU PSU PSU


2T2R 1T2R 1T2R
1T2R 1T2R RRU RFU RFU PDU
PDU RFU RFU
√ Add 3 pcs L1800 RRU(from H3I)

FANc
FANc

√ Dismantle GRFU/MRFU

UPEUd
UBBPe4
UPEUd

UBBPe4
√ Install Install 6 pcs WRFU,then WBBP UMPT
WBBP UMPT
Casecade RFU for each sector
Dismantle GRFU/MRFU, Packing, and Deliver to WH DCDU DCDU
DCDU DCDU
FMU FMU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU
U2100WRFU
U2100 WRFU
U2100 WRFU

U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK BOTTOM OF RACK BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 70


15.7a Upgrade L18 SIMO to MIMO add dismantled RRU1800 & L21 SISO to MIMO cascade WRFU 6 sector
2-P Antenna
2-P Antenna

BTS3900A BTS3900A
L1800 RRU3959a
TCU 2T2R
TCU Combiner
SLPU Combiner SLPU

PMU PSU PSU PSU PMU PSU PSU PSU


2T2R 1T2R 1T2R
1T2R 1T2R RRU RFU RFU PDU
PDU RFU RFU
√ Add 3 pcs L1800 RRU(from H3I)

FANc
FANc

√ Dismantle GRFU/MRFU

UPEUd
UBBPe4
UPEUd

UBBPe4
√ Install Install 6 pcs WRFU,then WBBP UMPT
WBBP UMPT
Casecade RFU for each sector
Dismantle GRFU/MRFU, Packing, and Deliver to WH DCDU DCDU
DCDU DCDU
FMU FMU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU
U2100WRFU
U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK BOTTOM OF RACK BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 71


Scenario 16.1a Upgrade L18 SIMO to MIMO existing RRU license only & L21 MIMO existing RRU license 3 sector

L1800 RRU3959a L2100 RRU3959a


L1800 RRU3959a BTS3900A 2T2R
BTS3900A 2T2R L2100 RRU3959a 2T2R
2T2R TCU
TCU
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

FANc
FANc

UPEUd
UBBPe4
UPEUd

UBBPe4 UMPT
UBBPe4 UMPT
√ Add 1 pcs UBBPe4 on slot 2
DCDU
DCDU
FMU
FMU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 72


16.1b Upgrade L18 SIMO to MIMO cascade GRFU/MRFU & L21 MIMO cascade WRFU 3 sector

BTS3900A 2-P Antenna 2-P Antenna


BTS3900A

TCU TCU
SLPU SLPU

PMU PSU PSU PSU PMU PSU PSU PSU


Combiner Combiner
PDU PDU

1T2R 1T2R 1T2R 1T2R 1T2R 1T2R

FANc
FANc

RFU RFU RFU RFU RFU RFU

UPEUd
UBBPe4
UPEUd

UBBPe4
WBBP UMPT WBBP UMPT
Add new RFC Cabinet

DCDU Move WRFU to new RFC Cabinet DCDU DCDU


FMU FMU
Install 3 pcs GRFU/MRFU,then

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU

G1800 GRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

Casecade RFU for each sector


Install 3 or 4 or 6 pcs GRFU/MRFU,then
Casecade RFU for each sector

BOTTOM OF RACK BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 73


16.2a Upgrade L18 SIMO to MIMO add new RRU & L21 MIMO new RRU 3 sector (3G reduce to 3 sector)

L1800 RRU3959a L2100 RRU3959a


BTS3900A 2T2R
BTS3900A 2-P Antenna 2-P Antenna 2T2R
TCU
TCU
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
Combiner Combiner
PDU
PDU

1T2R 1T2R 2T2R

FANc
2T2R
RFU
FANc

RFU RRU
RRU

UPEUd
UBBPe4
UPEUd

UBBPe4
WBBP UMPT
WBBP UMPT
√ Add 3 pcs L1800 and 3 pcs L2100 new RRU
√ Dismantle GRFU/MRFU and WRFU DCDU
DCDU
FMU
FMU √ Connect L1800 RRU fiber to UBBPe4 (port 0,1,2),L2100 RRU
fiber to UBBPe4 (port 3,4,5)
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 74


17.1 Upgrade L18 SIMO use dismantled RRU license only & L21 SIMO to MIMO existing RRU license 3 sector

L1800 RRU3959a L2100 RRU3959a


BTS3900A 2T2R
BTS3900A L2100 RRU3959a 2T2R
2T2R TCU
TCU
SLPU
SLPU
PMU PSU PSU PSU
PMU PSU PSU PSU
PDU
PDU

FANc
FANc

UPEUd
UBBPe4
UPEUd

UBBPe4 UMPT
UBBPe4 UMPT
√ Add 1 pcs UBBPe4 on slot 2
√ Add 3 pcs L1800 RRU(from H3I), Connect L1800 RRU DCDU
DCDU
FMU
FMU fiber to Slot 3 UBBPe4 (port 0,1,2)

BOTTOM OF RACK
BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Page 75