Professional Documents
Culture Documents
1+1 HSB-FD-SD
Commissioning
www.huawei.com
For RTN 620, the paired slots (slot5 and slot7) consist a 1+1 protection group; the
paired slots (slot6 and slot8) consist another 1+1 protection group.
Slot 5 and slot 6 is main slot respectively.
For 1+1 HSB and SD application, It is only necessary to configure main IF board
parameters.
For 1+1 FD application, It is necessary to configure main parameters and standby
parameters respectively.
While aligning antennas, the microwave link is not stable, will create these alarms.
In order to finish antennas aligning quickly, for 1+1 application, we suggest turn off
the standby IF ODU-PWR switch at first, after antenna aligning finishing, turn on
the standby IF ODU-PWR.
HSM Support × √ √ —
Turn on Standby
1+1 Switch State
IF ODU-PWR
and Test
Switch
To Next Page
① ③
① ③
④ Right Click
Turn on Standby
1+1 Switch State
IF ODU-PWR
and Test
Switch
④
⑤
⑥ ⑦
④
⑤
⑥ ⑦
Turn on Standby
Align Standby
IF ODU-PWR
Antenna
Switch