An error code will appear on the display automatically when a fault causes the inverter to trip. The following table lists the cause associated with the error. Causets) ay ‘Over-current event while at constant speed The inverter output was short-circuited, or the motor shaft is locked or has a heavy load. E02 ‘Over-current event during deceleration These conditions cause excessive current for the inverter, so the inverter output is turned 03 ‘Over-current event during acceleration OFF. The dual-voltage motor is wired incorrectly. Eo ‘Over-current event during other conditions E05 ‘Motor overload protection /When a motor overload is detected by the electronic thermal function, the inverter trips Jand turns OFF its output. Check that the thermal model is property set in Parameter b0 (2, b0 13, 69 10, b9 I! and b9 12. Check if the application can accept softer accel- ration rates to minimize peak currents FOO2/ /Feoz/A0s2/R2S2). Check if motor parameters are not correctly set (H020 to HO34 or HO0S), depending in motor [control method (ROY4/RE4), 06 Braking resistor overload protection When the BRD operation rate excoods the set ting of "8090", this protective function shuts off the inverter output and displays the error code. en ‘Over-voltage protection [When the DC bus voltage exceeds a threshold, [due to regenerative energy from the motor. E08 EEPROM error [When the builtin EEPROM memory has prob- lems due to noise or excessive temperature, {the inverter trips and turns OFF its output to the motor. Ero. Code Cause(s) E03 Under-vorlage error ‘A decrease of internal DC bus voltage below & threshold results in a control circuit fault. This condition can also generate excessive motor heat of cause low torque. The inverter trips and turns OFF its output. Eo ‘Current detection error Tan error occurs in the internal current deteo- tion system, the inverter will shut off its output and display’the error code. ‘GPU error ‘A malfunction in the builtin CPU has occurred, so the inverter trips and turns OFF its output to the motor. External tip ‘Asignal on an intelligent input terminal configured as EXT has occurred. The inverter trips and turns OFF the output to the motor. usr When the Unaltended Start Protection (USP) js enabled, an error occurred when power is applied while a Run signal is present. The inverter trips and does not go into Fun Mode until the error is cleared. En Ground fault The inverter is protected by the detection of ground faults between the inverter output and the motor upon during powerup tests. This feature protects the inverter, and does not pro- tect humans. Es Input over-voltage The inverter tests for input over-voltage after the inverter has been in Stop Mode for 100 sec- fonds. If an over-voltage condition exists, the inverter enters a fault state. After the fault is cleared, the inverter can enter Run Mode again. Ea7 Tnverter thermal tip When the inverter internal temperature is above the threshold, the thermal sensor in the inverter modiila datacts tha excessive tamnaratire of the power devices and trips, turing the inverter output OFF. Eee ‘CPU communication error ‘When communication between two CPU fails, Inverter trips and displays the error code. E25 Main circuit error (3) The inverter will tip if the power supply estab- lishment is not recognized because of a mal- function due to noise or damage to the main circuit element. E30 Driver error instantaneous overcurrent occurs the Inverter will shut off IGBT's output to protect the main circuit element. After ripping due this protective function the inverter cannot retry the operation. E35 Thermistor When a thermistor is connected to terminals [5] and [L] and the inverter has sensed the temper-| ature is too high, the inverter trips and turns OFF the output, E36 Braking error When “0 f has been specified for the Brake Control Selection (b120), the inverter will tr itcannot receive the braking confirmation signal, within the Brake Wait Time for Confirmation (b 124) after the output of the brake release sig- fal. Or when the output current doesn't reach. the brake release current (b 126) during the brake wait time for release (b 12 1) En Safe Stop Safe stop signal is given.” E38 Low-speed ‘overload protection overload occurs during the motor operation at a very low speed, the inverter will detect the overload and shut off the inverter output. Eso ‘Operator connection When the connection between inverter and operator keypad failed, inverter trips and displays the error code. Name Tause(s) EY Modbus communication | When “trip” is selected (C016=00) as a error behavior in case of communication error, inverter trips when timeout happens. [E13 | Drive Programming invalid | The program stored in inverter memory has instruction been destroyed, or the PRG terminal was. turned on without a program downloaded to the inverter. E41 [Drive Programming ‘Subroutines, i-statement, or fornext loop are nesting count error nested in more than eight layers ES | Drive Programming nvertet found the command which cannot be instruction error executed. [ES to | Drive Programming user | When user -defined tip happens, inverter trips Go trip (0 to 9) and displays the error code. [EGO to | Option errors (ervar in con- | These errors are reserved for the option board [E69 nected option board, the | Each option board can show the errors for adi meanings change upon | ferent meaning .. To check the specific mean- the connected option)._|ing, please refer to the corresponding option board user manual and documentation. [é80 | Encoder disconnection |i the encoder wiring is disconnected, an encoder connection error is detected, the fencoder fails, oran encoder that does not support line driver output is used, the inverter will shut off its output and display the error ‘ode shown on the right. EB1 [Excessive speed Tithe motor speed rises to “maximum frequency (8004) x overspeed error detection level (PO26)" oF more, the inverter will shutoff its output and isplay the error code shown on the right. [£83 | Positioning range error If current position exceeds the position range specification (PO12-P0723), the inverter will shut ff its output and display the error code.

You might also like