You are on page 1of 1

How to change the time setting of SK280

1. Take off the front panel of SK280.

2. Enter the parameter menu by pressing S2 on the powerboard:

Displayname Parameter default value max min

PR1 programtime 1 30 (seconds) 9992 5


PR2 programtime 2 60 (seconds) 9992 5
PR3 programtime 3 150 (seconds) 9992 5

With T3 or T1 in the keyboard you scroll up and down through the parameter list. To view the
value of a parameter press T2. To change the value use T1 or T3. To save the value press
T2. To leave the value without saving press the stop/up button. After saving or leaving a
parameter the board is in normal shaking mode. To change/view another parameter use S2
again.

Attention, changes to the default shaking times can influence the durability of the shaker.

FAST & FLUID Management Australia