1. De-Air pumps on the HA X80.
2. Colorant Conditioning parameters.
3. Valve Actuator.
4. Machine Movements
5. Turntable Slack measure.
6. Pump tube, Seal replacement
7. Third Party Software
8. Wiring Diagram.
9. Board Errors.
10.Information links.
2
De-airing pumps on the HA X80
3
Colorant Conditioning Parameters in the Settings
4
Valve Actuator
Valve Actuator
Valve motor
5
Valve alignment offset
6
Valve Hole selection
7
Machine Movements.
8
Movement indicator
9
Pump stepper at home, valve in a not at home position. Table is
not allowed to turn.
Valve is allowed to turn.
10
E99
11
Error E99
If you can not free the motion of the valve or the table
can't turn, it is necessary to remove the valve bracket.
Remove the four hexagonal screws (red circles).
Remove the complete bracket, bring if necessary the
pump stepper back on the home position, set the valve on
the home position. Turn the table to the "Reset" position
place the valve bracket and give the machine a reset.
12
Turntable Slack Measure.
13
Values for slack:
This part will updated a.s.a.p
To adjust the Slack you need to loose the upper two bolts only,
with the set bolt you can adjust the slack. After reach the
correct slack value secure the upper two bolts again.
14
Seal Piston rod replacing.
15
4. Turn the blue ring till it
is blocked by the valve
house. You must see
the blue tabs, that is the
end of the slide.
16
6. Push the piston rod out of the tube in
the direction of the arrow. Check the
inside of the tube for any contamination.
17
8. Place the O ring back on the
tube before placing. Do not
place the Oring in the valve
house before placing the tube
back.
18
9. Place the piston rod maximum
2mm back in the tube as shown on
the picture. This because you can
not push the rod down when placed
on the valve house back again.
19
Third Party Software
Using Largo you must set no hook in the Channels “Driver Handles Remove Can”
Set no hook at the Brush and no value by Nozzle cleaning.
In all third party software it is not allowed to set any Purge time or Purge amount.
All conditioning parameters are set on the HA X80 board,via the *.ide4 file.
20
21
22
Software Downloads: http://my.fast-fluid.com/