Thank you very much for purchasing the products of Golden Lion welding
machine.
◆ Please read this manual carefully and keep it properly before use for future
reference.
Second, the input power line specifications: three-phase four-wire transmission, U V W three fire
wire diameter ≥ 12mm2 copper wire, connected to the input wiring row of the control cabinet,
ground wire ≥ 6 mm2, access to the input wiring block of the control cabinet, (pay attention to
the position of the zero line N. As shown in Figure 1:
Third, access to compressed air: from the air compressor to lead the trachea inserted into the
compressed air input of the equipment, as shown in Figure 2, the air pressure is adjusted to 0.4-0
6MPa 。 (Pressure regulation method: pull the black knob on the upper end of the pressure
reducing filter with force, rotate clockwise to increase the pressure, counterclockwise reduce the
pressure, adjust it and then press it.) )
Fourth, the injection of hydraulic oil: open the lid of the tank mouth, add good quality anti-wear
hydraulic oil #46, so that the oil level reaches the full scale of the tank temperature gauge, as shown
in Figure 3 (full About 250 liters of hydraulic oil is required. The filling port is located in
Figure 4:
8、 Processing steps: in the automatic screen or in the manual screen to select the display of
"single" status: put the tube on the feeding rack, start the foot switch, start automatic feeding,
the tube falls to place, left and right The clamping cylinder begins to push inward, and after
the thrust is in place, the delay begins to punch,
and the punching ends. The middle
clamping cylinder action clamps the pipe
tightly, and after the punching is retracted into
place, the left and right clamping cylinders
begin to retreat, and after the middle cylinder is
released and the unloading begins, The
processing ends automatically after the
discharge is completed. For the next process, you also have to press the foot switch to start. If
you select the Continuous state, you can start the foot switch only once. As long as there is a
tube, it will work continuously and continuously. Until the power is cut off or the
"Emergency Stop" button is pressed. (The Single-Shot and Continuous states are selected
based on the actual situation.) It is recommended to select the Single-Time status when you
first start the operation).
Eight: common faults and solutions and maintenance instructions
1、 Pedal switchgear does not work:
A: Whether the emergency stop switch is locked, reset can be
B: The foot switch is not turned on, directly short connect the two wires to try, if it is
good, replace the foot pedal.
C: The cable plug of the control box and the equipment is not plugged in, and it can be
plugged in.
D: The retract limit probe on the left and right clamp cylinders and punching cylinders is not
in place, as long as any one is not in place or the probe is broken, the equipment does
not work. (Check the auto screen whether the input signal of the
X3/X5/X20/X21/X26/X27 probe turns green.)
2、 Hole punching:
A: The pressure of the oil pump is not enough, increase the pressure.
B: The time of setting the "punching time" parameter in the parameter setting screen is
short and the time is increased.
C: The punch is broken, replace.
3、 The punched hole has burrs: the punch is heavily worn or the die core is worn.
Replacement.
4、 In the normal processing process, after the tube falls, the left and right forward push
cylinders do not move forward, and the rest do not move:
Check whether there is a limit probe at the left and right loading and unloading
cylinders, whether the probe probe is probing to the tube (the distance of the probe
surface from the tube is not more than 4MM), or the probe is broken, adjust the
distance or replace. (Either one has a problem and does not act).
5、 In the continuous state, there are tubes, and the equipment does not work
continuously
Check whether the X6 continuous feed signal probe on the edge of the loading cylinder is lit
A: not bright, whether the probe distance is far, should be ≤ 4mm Adjust the distance
closer or the probe is broken or the line is broken.
B: The light is on, the automatic screen X6 light does not turn green, the PLC-X6 input
light is not on: the probe is broken, replace.
6、 If you want to finish this one in a continuous state, press the "single/continuous"
button again, become a single word, and the device will stop after flushing this one. If
you start the device again, you must press the foot switch to start it.
7、 Press the "Punch in", "Relief Valve", "Left and Right Clamping" keys in the manual
screen, and the cylinder does not respond and does not move.
A: The corresponding relay light in the control box is not lit, and the oil valve lamp is
not lit, which may be that the transformer fuse is burned. The location is shown in
Figure 11. Replace the fuse, if you replace it with a new one and burn it again, then
the oil valve coil is burned out, and check the oil valve coil one by one.
B: Whether the emergency stop switch is pressed and locked, reset can be.
8、 Press the "Motor On" button on the operation box, and the motor does not turn:
A: The contactor does not fit: use a multimeter to measure whether the motor open and
the electrical organ key switch are in poor contact, there is no connection, the motor
open button: connect to the normal opening point, the electrical organ button: the
normal closing point. Replace the key switch. Whether the normal closing point of the
heat measurement relay is on, it is not passed, the
thermal relay is protected, and the reset can be.
B: Contactor suction, no problem with the switch,
measure whether the three-phase electricity at the
front and rear ends of the contactor has a voltage
AC220V, the input has electricity, the output has no
electricity, the contactor is broken, replace. If there is
electricity on both ends of the contactor, test whether
the thermal relay burns out.
C: There is no problem, the motor power supply has three phases of electricity, the
motor does not rotate, and the motor is replaced badly.
9、 If only one end hole needs to be punched, the on-off valve shown in Figure 12 needs to
be closed.
10. Replacement of the punching rod method: As shown in Figure 13:
A: Remove the feeding and unloading racks first. The
cylinder retracts into place, removes the three screws
marked 1 on the figure, and uses a crowbar to move the
guide sleeve toward the bottom in the direction of the
arrow
B: Remove the 2 connecting rod from the cylinder shaft
with a hammer.
C: Exit the guide sleeve in the opposite direction, and
the punch rod can be taken out.
Replace the bar and
restore it in order.
2、 "Manual Screen" button: Press once to enter the "Manual Screen" page.
3、 "Parameter Settings" button: Press once to enter the "Parameter Settings" page.
B. Automatic screen: mainly shows the process of action, whether the limit probe is lit. As
shown in Figure 16,
1. "Start" button: You can press this button at
startup
2. "Stop Emergency Stop" button: You can
also press this button when the emergency
stops.
3. Parameter Parameter button: Press under
this page to enter the parameter settings page.
4 "ESC" button: Click to exit this screen.
5, the other is the display of the input
corresponding to the control signal light, the initial state is red, after the position should
become green, in place if not green, indicating that the probe distance is far or bad.