SKETCH
SHELL CONNECTION
Mark Size /Rating Qty Application
N1 40"/150# WNRF 1 LIQUID INLET w/Internal Pipe
N12
N2 30"/150# WNRF 1 LIQUID OUTLET w/internal pipe
N3-5 10"(TBD)/150# SORF 3 (TBD) ROOF DRAIN ( SHELL CONN.)
N6A-D 6"(TBD)/300# WNRF 4 (TBD) STEAM INLET c/w VALVE
CONDENSATE OUTLET c/w reducer 2"
N11 3"(TBD)/300# WNRF
N7A-D 4 (TBD) & valve
N8-10 4"(TBD)/150# SORF 3 (TBD) WATER DRAIN w/internal pipe & Sump
N11A-D 2"(TBD)/150# SORF 4 (TBD) TEMPERATURE INDICATOR
CO 36" X 48" 1 FLUSH CLEANOUT DOOR
M1A-D 24" API-650 4 SHELL MANHOLE
M3A-D 30"(VTA)/150# WNRF 4 (VTA) MIXER CONNECTION
ROOF CONNECTION
N12A-E 12" (VTA) 5 (VTA) AUTO BLEEDER VENT
GH1 12" (VTA) 2 (VTA) GAUGE POLE W/GAUGE HATCH
GH2 12" (VTA) VTA GUIDE POLE
T1 4"/150# SORF 1 TEMPERATURE TRANSMITTER
T2 2"/150# SORF 1 TEMP. INDICATOR
L1 8"/150# SORF 1 LEVEL TRANSMITTER
L2 3"/150# SORF 1 LEVEL SWITCH
M2A-D 24"API650 4 (VTA) ROOF MANHOLE
RV 6"(VTA) VTA RIM VENT
MC 20"(VTA) API 650 VTA COMPARTMENT MANHOLE
SD VTA VTA ROOF DRAIN SUMP