In-line Inspection Tool and

Standards
Presented by Suparerk Sirivedin
16 September 2020

Contact Information:
[Project Manager]
129/9, Soi Hatsadisewi, Sutthisan Winitchai Road
Huai Khwang, Bangkok, 10310, Thailand
Email: [Project Manager Email]
Definition of PIG
Standard Codes for Pigging

POF 2026
Pipeline Operators
Forum

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


Intelligent PIG

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18
Intelligent PIG components

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


Objectives of Intelligent PIG

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


Types of Intelligent PIG

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


Repair and Remediation

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


ASME 31.8S

7.2.1 Metal Loss Tools for Internal & External Corrosion

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


ASME 31.8S

7.2.2 Crack Detection Tools for Stress Corrosion Cracking (SCC)

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


ASME 31.8S

7.2.3 Metal Loss & Caliper Tools for 3rd Party & Mechanical Damages

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


Geometry Detection Tool

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


Gauging Pig Deformation

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


Gauge Plate Damage by Internal Concrete Liner

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


Caliper & Mapping Tool

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


Caliper Tool Components

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


Caliper Tool Components

ODOMETER

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


Example of Caliper Results

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


Example of Caliper Results

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


UT Tools

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


UT Tools

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


UT Signal Analysis

Normal pipeline External defect Internal defect

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


UT Data Analysis

Software “opens up” the pipeline B Scan Shows C Scan Shows


to display the data in an easy Wall Thickness Defect Location
to understand format. In Pipeline Circumference

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


A Scan Data

amplitude

time

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


UT Data Analysis Results

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


B Scan Data

The B-scan display produces a view of the test object that looks as if it
were cut through and turned on its side to show in cross section
whatever internal reflectors or opposite surface conditions exist.
SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18
C Scan Data

• The C-scan display uses a plan view.


• The received signals are converted to variations in color.
SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18
Actual UT Inspection Results

Weld #1

Heavy
Corrosion

Weld #2

Weld #3

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


Magnetic Flux Leakage (MFL)

Permanent Magnet and Steel Brushes


Pulling Body

Additional Battery, if any require

Odometer unit

Sensors Carrier

CPU, Data Acquisition, Built-in IMU and


Battery units

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


MFL Inspection Principle

A defect will generate a variation in magnetic signal, which is


related to size and depth of the defect.

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


MFL Inspection Result

SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18


SYN-GE-FRM-900 Rev 1, Presentation, 28-Dec-18
Thank You/Q&A ?