Proposal: 15 Kw On-Grid Solar Roof Top PV System

We as Shree Chandramangal Suncity Marketing Pvt. Ltd. Registered under


company Act 2013 and certified with ISO 9001 : 2015. We are glad to introduce our
firm symbolizes the best in optimized performance, a pioneering spirit innovative
approach through technological expertise in Solar. We are having a highly
motivational & professional satisfactory team with quality and reliability to solar
team, excellent infrastructure facilities, sales & service network together, synergies
in innovative goal of customer satisfaction, quality & reliability.

System Design
Place of
Installation
Module Facing True south
Space available More then 1500 Sq.Ft./KW (Approx)
Type of Roof RCC / Tin Shed / Ground
Solar Unit Generation per day (4.0 - Yearly average) 3 to 5.5 Unit/Per KW / Perday

Proposed Technology
The Proposed solar photovoltaic power plant shall be consisting of crystalline solar
module with fixed tilt Angle mounting systems and the Solar Inverter shall be grid tied.

Benefits of Proposed Technology


1. Accelerated Depreciation Benefit @ 100% (which helps offset your tax liability)
2. Convert unused roof space into a valuable energy resource.
3. Rooftop Solar Investment is returned in less than 5 years.
4. No interconnection problems, No wheeling charges and transmission losses.
5. Insulation from likely increase in energy cost.
6. Long Life (25years).
7. Low operation & Maintenance
8. Clean, Quiet and Visually Unobtrusive
9. Long term energy security
Bill of materials (BOM)
SR. Component/Item
Description Make/Capacity Quantity
No. Name

Poly Crystalline
1 Solar PV Module Modules (Nos 330W/24V Suncity Solar
confirming to relevant Module (25 Years 45
IEC standards) Performance Warranty )
Inverter with associated
control and protection
devices integrated to Luminous On grid Inverter
2 Solar Inverter 1 NOS
convert DC Power into with GPS 15 KW
3Phase AC voltages,
along with on grid
synchronizing facility.
Aluminum and GI (80
Module As per Design
Microns). All structures
3 Mounting Structure APOLLO
are designed for local
Structure 50mmX50mm and
wind (150Km/hr
40mmX40mm
maximum speeds) and
weather conditions.

AC/DC All Switchgear from ISI


4 Distribution Box Enclosure CRCA mark with Finolex/Polycab As per Design
wiring

MCCB/MCB

RYB Phase Indication


Power Circuit Wiring
Accessories (Sleeves,
Lugs, Nut/Bolts,
Enclosure Hanging
Bracket etc)
Double Compression
Metallic
Cable Gland for Incoming
&Outgoing
SR. Component/Ite
Description Make/Capacity Quantity
No. m Name
Resistance against UV,
5 DC Cable POLYCAB/HAWELLS As Per
Water ,Ozone , Fluids, Oil
Requirement
, Salt & general
Weathering.
Electron Beam Cross
Linked
, Halogen Free ,Flame
Retardant, Low Smoke
emission,
Fire Retardant to meet
IEC 607541-1/EN
50268-2
Ma. Temp. at Conductor:
100*C ((20000h)
Test Voltage : Resistance
Test : EN 50395
Rated Voltage : 600/1000
V

Short Circuit Temp :


6500V

Short Circuit Temp


:+280*c
IT Power Cable will be
11kV Armoured
,Single/multi-
6 AC Cable core,Stranded Al POLYCAB/HAWEL As Per
conductor as mentioned, LS Requirement
XLPE insulated with PVC
outer sheath made on PVC
compound , conformity to
IS:70998
Earthing Material : GI
and Cu As per IS 3043-
1987
7 Earthing IMV/ Sabo Chemical Reputed Make As Per
earthing Total 3 earthings Requirement
for inverter Module
Mounting structure, LA,
DCDB, LT panel etc
Component/Ite
SR. Description Make/Capacity Quantity
m Name
No.
Certified for applications
with modules according to
IEC 61730, Safety class II,
Directive 2002 /95/ EC on
the restriction of the use of
certain hazardous
8 MC4 Connector substances in electrical Reputed Make As Per
and electronic equipment Requirement
–with Mimimal power
loss, Minimal contact
resistance , High durability
contacts withstand up to 1
million mating cycles,
Operating temperatures up
to 350*c.
IS: 9537 Part 3, BS:EN
PVC Conduit 61386-21 for UPVC
9 Pipe PRECISION/Reputed
conduits, IS: 3419 and Make As Per
BS:4607 for UPVC
Requirement
fittings.
10 Cable Tie UV protective REPUTED As Per
MAKE Requirement
As per IEC 62305-3 &UL
11 Lighting Std. As Per
96,IS 2309
Arrester Requirement
Dated – 14-09-2021
Proposal confined to – MCD HP FILLING STATION
SOJAT CITY

Cost and Viability of Complete Roof Top Solar Power 15 KW Plant (Suncity)
Total Cost in Rs. INR 6,43,524/-
GST ( 5%) 32,176/-
Grand Total with GST 6,75,700/-

Contribution Towards Nation Building


Name of Physical 25 Years
S.No Quantities 1 KW Per Year 15 KW Per year App.

1 Electricity Saving 1600 Units Per Year 24,000 Unit Per year 6,00,000
CO² Emission
2 Reduce 1.825 Ton Per Year 27.375 ton Per Year 684.375 Ton

3 Trees Saving 7 Trees Save per Year 105 trees per year 2625 Trees

4 Coal Saving 800 KG per Year 12,000 KG Per year 3,00,000 KG


16 Lacs cubic feet per 2.4 Crore Cubic Ft. Per 60 Crore
5 Natural Gas Saving year Year Cubic Feet
1,52,625
6 Liquid Fuel Saving 407 Litres Per year 6105 Litres Per Year Litres

Promote Solar Energy & Build the Nation , Save Electricity

Looking for an everlasting association

Thanks & Regards

(Manoj Purohit)

General Manager
Terms & Conditions
1 Payment Terms 40% against release of order 60% before Dispatch of Material

PV Modules -25 years Warranty on power Output (90% of the rated power is
guaranteed over a period of 10 years and 80% of the rated power is guaranteed
2 Warranty over a period of 25 years ). (Degradation 0.5% to 1% per year)
Inverter --5 Year System warranty except natural calamities.

Deleivery & Installation 30-45 Days from the Date of Receipt of technically & Commercially clear order
3
Schedule and Advance Payment

4 Validity of Offer 15 Days from the date of offer. After this period a confirmation has to be taken.

A. Roof Top to be arranged and provided by the client.


B. Electricity & Water shall be provided by client during the construction of the
said project
C. Provide safe storage space for the material being used for Solar Power Plant.
D. Provide Electricity supply to synchronize the inverter on commissioning and
commissioning onward.
5 Client Scope
E. Provide connection space in the LT panel to connect the Inverter Output.
F.Internet Connection to be provided by the client for remote monitoring of the
system .
G. Cleaning of solar modules in your scope
H. One Person from client side for basic training of operation of solar PV
system.

A. Cost of Super Structure (High Rise ) as per customer choice (If any ) shall be
borne by customer.
6 Exclusion B. This offer is valid for normal side conditions.
C. Any extra length of cable (If more than 90 feet)
D. Transportation cost will be extra if more than 30 KM of Jodhpur city radius.
If at any stage during the period of contract the performance of any obligations
under the contract is prevented or delayed whollaly or partaly be reasons of war,
hostility,fire,floods,lightning,epidemics,sabotages, guarantee,restrictions or other
acts of God ,Government or Law (herin after referred to as eventuates ) then a
notice of the happening of any such eventuality will be given with in 7 days from
7 Force Majeure
the Date of occurence of any such eventuality in such case neither party nor shall
any claim to be made for damages against the order in respect of such non
performance or delay and the performance and deleveries of the contract will be
resumed as soon as practicable after such eventualityhas come to an end or
ceased to exit.