Physical Setup
As we have POE switch,
Plug the ethernet cable into the ethernet port of the AP and plug the other end into the LAN
As the access point turns on the indicator(the status LED) will turn into orange…… If the unit does not
require a firmware upgrade, the LED will turn either green (no clients associated) or blue (clients
associated) within thirty seconds.
[Note: If the unit requires an upgrade, the LED will begin blinking orange until the upgrade is complete
automatically, at which point the LED will turn solid green or blue. You should allow at least a few
minutes for the firmware upgrade to complete, depending on the speed of your internet connection. ]
then, we can get access to the AP through the wifi connection of our end devices.
Factory Reset Button
If the button is pressed and held for at least five seconds and then released, the AP will reboot and be
restored to its original factory settings by deleting all configuration information stored on the unit.
Physical Specifications
MR36
Interfaces 1x 10/100/1000 BASE-T Ethernet (RJ45)
1x DC power connector (5.5 mm x 2.5 mm, center positive)
Power Power over Ethernet: 37 - 57 V (802.3af compatible)
Alternative: 12 V DC input
Power consumption: 15W max (802.3af). Note: actual power consumption may vary
depending on the AP usage.